Introduction…………………………………………………………………………………………….. 2 Important Safety
Information …………………………………………………………………… 3 Before Using Your Monitor
………………………………………………………………………. 5
1. Know Your Monitor……………………………………………………………………………………………5 2. Insert and
Replace the Batteries…………………………………………………………………………6 3. Pair Your Monitor with
Your Smart Device ……………………………………………………………7 4. Set the Measurement Unit, Date
and Time ……………………………………………………………….. 8 5. Set-up Your Personal Data
………………………………………………………………………………..9
Operating Instructions …………………………………………………………………………… 10
6. How to Take a Measurement Accurately…………………………………………………………….10 6.1 Correct
posture during the measurement ……………………………………………………..10 6.2 Proper storage for
“0 lb correction” ……………………………………………………………… 11 6.3 How to implement the “0 lb
correction” ………………………………………………………… 11
7. Taking a Measurement……………………………………………………………………………………. 11 8. View Your
Measurement Results on Your Smart Device ………………………………………13 9. Select Your User
ID and Take a Measurement ……………………………………………………14 10. Guest Mode (Unrecorded
Mode) ………………………………………………………………………15 11. Measure Weight Only
……………………………………………………………………………………..16 12. Change or Delete Your Personal
Data……………………………………………………………….17 13. Delete the Communication
Setting…………………………………………………………………………… 18
Care and Maintenance …………………………………………………………………………… 18
14. Maintenance and Storage ……………………………………………………………………………………18 15.
Troubleshooting …………………………………………………………………………………………………… 19 16.
Specifications…………………………………………………………………………………………………22 17. FCC Statement
………………………………………………………………………………………………24 18. Limited Warranty
…………………………………………………………………………………………….25 19. Guidance and Manufacturer’s
Declaration………………………………………………………….26
Information on Body Composition …………………………………………………………. 27
20. Information on Body Composition……………………………………………………………………..27 21.
Measurement Results Interpretation Diagrams ………………………………………………….29
1
Introduction
Introduction
Thank you for purchasing the OMRON Body Composition Monitor and Scale with Bluetooth®. This monitor is intended for measuring and displaying the following body composition parameters.
– Body Weight
– Body Fat (in %)
– Visceral Fat (up to 30 levels)
– Skeletal Muscle (in %)
– Resting Metabolism (in kcal)
– BMI (Body Mass Index)
This monitor is intended to be operated by adults who can understand this instruction manual. It is not for professional use in hospitals or other medical facilities, it is intended for home use only.
Safety Instructions
This instruction manual provides you with important information about the
OMRON BCM-500. To ensure the safe and proper use of this monitor, READ and
UNDERSTAND all of these instructions. If you do not understand these
instructions or have any questions, contact
1-800-634-4350 before attempting to use
this monitor. For specific information about your own body composition related
conditions, consult with your physician.
Intended Use
The OMRON BCM-500 is intended to be used to calculate and display the estimated value of body fat
percentage, skeletal muscle percentage, resting metabolism, BMI and visceral fat levels using the BI
(Bioelectrical Impedance) Method and indicates the BMI (Body Mass Index).
The BCM-500 is intended to be used by healthy individuals in the age range of 18 to 80 years for
the skeletal muscle percentage, resting metabolism and visceral fat level. The age range for body fat
percentage is intended to be used by healthy individuals between the age of 10 to 80 years.
EN
Receiving and Inspection
Remove this monitor and other components from the packaging and inspect for
damage. If this monitor or any other components are damaged, DO NOT USE and
contact 1-800-634-4350.
Symbols Glossary
For symbol information, visit: OmronHealthcare.com/symbols-glossary
Contraindications
· DO NOT use this device if you have a cardiac pacemaker, implanted
defibrillator or other implanted metallic or electronic device. Such use could
cause these devices to malfunction causing serious health risks or death to
users.
2
Important Safety Information
Important Safety Information
Read the Important Safety Information in this instruction manual before using
this monitor. Follow this instruction manual thoroughly for your safety. Keep
for future reference. For specific information about your own body composition
conditions, CONSULT WITH YOUR PHYSICIAN.
Warning
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
· Keep this monitor out of the reach of infants, toddlers and children. ·
Pregnant women should not use this device. · DO NOT use this monitor on
slippery surfaces, such as a wet floor. · Consult with your physician or
healthcare provider before beginning a weight reduction or exercise
program. · DO NOT jump or bounce on this monitor. Doing so may cause you to
fall or slip, resulting in serious
injury. · DO NOT step on the edges or display area of this monitor because you
may lose your balance and
fall, resulting in serious injury. · ALWAYS stand on this monitor bare-footed.
Standing on this monitor wearing socks may cause you
to slip and injure yourself. · DO NOT use this monitor when your body and / or
feet are wet, such as after taking a bath or
shower. · Persons with disabilities or persons who are physically frail should
be assisted by another person
when using this monitor or use a handrail, a walker, or other support device
to prevent falling when stepping on and off the monitor. · DO NOT use this
monitor with a cardiac pacemaker or other implanted medical device.
Battery Usage
· Should battery fluid leak and contact your eyes, skin or clothing,
immediately rinse with plenty of clean water. Immediately contact your
physician in case of eye or skin contact.
Data Transmission
· This product emits radio frequencies (RF) in the 2.4 GHz band. Do not use
this product in locations where RF is restricted, such as on an aircraft or in
hospitals.
Note: For further information on potential restrictions refer to documentation
on the Bluetooth usage by the FCC.
Caution
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user orpatient or damage to the equipment or other property.
· DO NOT attempt to disassemble, modify or repair this monitor. Changes or
modifications not approved by Omron Healthcare will void the user warranty.
· DO NOT step on the edges or display area of the measurement platform because
the display unit may be damaged.
· DO NOT submerge this monitor or any of the components in water.
· Avoid excessive impact, vibration and strong shock to this monitor.
3
· DO NOT place this monitor on a cushioned floor surface such as a carpet or
mat. A correct measurement may not be possible.
· DO NOT use this monitor for any purposes other than described in this
manual. · When this monitor will be used by several people, wipe the monitor
with a damp cloth moistened
with mild detergent after using it. Then, wipe it dry. · Ensure that this
monitor has acclimated to room temperature before taking a measurement. Taking
a measurement after an extreme temperature change could lead to an inaccurate
reading. OMRON recommends waiting for approximately 2 hours for the monitor to
warm up or cool down when the monitor is used in an environment within the
temperature specified as operating conditions after it is stored either at the
maximum or at the minimum storage temperature. For additional information of
operating and storage/transport temperature, refer to Section 16.
Battery Usage
· ONLY use AAA alkaline batteries specified for use with this monitor. DO NOT
use other types of batteries. DO NOT use new and used batteries together.
Replace all four batteries at the same time.
· DO NOT use different types of batteries together. · Dispose of the device,
batteries, components and optional accessories according to applicable local
regulations. Unlawful disposal may cause environmental pollution. · DO NOT
expose the batteries to flames or fire. · Remove the batteries if this monitor
will not be used for three months or more. · DO NOT insert the batteries with
the polarities in the wrong direction.
Data Transmission
· During measurement, make sure that no mobile phone or any other electrical devices that emit
electromagnetic fields is within 12 inches (30 cm) of this monitor. This may result in incorrect
operation of the monitor and/or cause an inaccurate reading.
· Do not replace the battery while your measurement result is being transferred to your smart device.
This may result in the incorrect operation of your monitor and failure to transfer your measurement
result.
· Do not place integrated circuit cards, magnets, metal objects, or other devices that emit
EN
electromagnetic fields near this monitor while your measurement result is being transferred to your
smart device. This may result in the incorrect operation of your unit and failure to transfer your
measurement result.
Note
Incorrect Measurement Incorrect measurement might occur to the following
users: Elderly people (over 81 years old) / People with a fever / Body
builders or highly trained athletes / Patients undergoing dialysis / Patients
with osteoporosis who have very low bone density / People with swelling. ·
Because the body composition such as body water might greatly deviate from the
average value.
4
Before using your monitor
1. Know Your Monitor
Contents
· Body Composition Monitor and Scale with Bluetooth® · 4 AAA alkaline
batteries (LR03) · Instruction Manual
Monitor
Display
231
32
· Quick Start Guide
Foot Electrodes
Foot Electrodes
43
14
SET Button · Press this button to set or confirm the data.
Advance Button · Press this button to advance. · Press and hold this button to
advance rapidly during setting the date, time
and height.
Bluetooth Button · Press this button to transfer the data manually. · Press
this button (2 seconds or longer) to pair your monitor with your smart
device. This button is also usable when the power is off. ON/OFF Button ·
Press this button to turn on the power. · Press this button (2 seconds or
longer) to turn off the power.
Display
User ID Symbol Lights when user ID is displayed.
Weight Symbol Lights when only measuring the body weight.
Battery Symbol (low/depleted)
Date, Birth Date Symbol Gender, Height Symbol
Time Symbol
Body Fat Percentage, Visceral Fat Level, Skeletal Muscle Percentage, BMI
Classification Indicator
5
SYNC Symbol Bluetooth Symbol
Before using your monitor
2. Insert and Replace the Batteries
1. Open the battery cover on the back of your monitor.
A hard object like a pen can be used.
1
2
2. Install the batteries in correct polarity as marked inside the
battery compartment.
2
1
3. Close the battery cover.
Battery Life and Replacement
Approximately 6 months (When AAA alkaline batteries are used for four measurements, four
data transfers and four persons a day at a room temperature of 73.4 °F (23 °C)).
· The supplied batteries are for trial use only, they may have a shorter life.
When the depleted battery symbol four batteries with new ones.
Depleted Battery
appears on the display, replace all
symbol
· Replace all four batteries with new ones (same type) at the same time.
· When the low battery symbol blinks, it is recommended to replace the
batteries with new ones.
EN
Replace the batteries after turning off the power. · Personal data stored in this monitor are retained even if the batteries are removed. · Disposal of used batteries should be carried out in accordance with the local regulations for the disposal of batteries.
When the batteries are replaced, you will need to reset the measurement unit,
date and time. (Refer to Section 4.)
· If you have already paired with the compatible OMRON app, press the button
to communicate with this app, then the date and time will be set
automatically.
About the Power OFF Function Press the button (2 seconds or longer) to turn off the power.
The power automatically turns off in the following conditions. · 10 seconds after “Err” is displayed. · This monitor is not used for 1 minute when “0.0 lb” is displayed. · This monitor is not used for 3 minutes.
6
Before using your monitor
3. Pair Your Monitor with Your Smart Device
1. Turn on the Bluetooth on your smart device. 2. Scan the code below with
your smart phone camera or visit
OmronHealthcare.com/app to find the OMRON compatible app for this product.
3. Download and then open the app on your smart device and follow the
instructions. NOTES · Each account set-up in the app manages data for one
unique user. · Only compatible OMRON app(s) should be used with this OMRON
body composition monitor and scale to help ensure correct data transfer.
7
Before using your monitor
4. Set the Measurement Unit, Date and Time
Setting the measurement unit, date and time is necessary before taking a
measurement for the first time or after replacing the batteries.
· The date and time will be automatically set when paired with your smart
device. To set manually, follow the instructions below.
1. Press the button to turn on the power.
“inchlb” blinks on the display.
2. Set the measurement unit.
Press the button to adjust and press the button to confirm. · The default
measurement unit is “lb & inch”. · You can set the measurement unit to “st-lb
& inch” or “kg & cm”.
3. Set the date and time on your monitor.
Press the button to adjust and press the button to confirm.
· Setting range of year: 2019 to 2045. · Time is a 12-hour clock.
· While setting the year, date, hour and minute, hold down the advance rapidly in increments of 10.
button to
Year
Month
EN
Day
After all the settings for the measurement unit, year, month, day, hour and
minute are displayed in that sequence, the power automatically turns off.
NOTES · If any mistake is made during the setting, press the button (2 seconds
or
longer) to turn off the power and start from “Step 1” again. · If, when
setting-up the measurement unit, date and time, this monitor is not used for 3
minutes, the
power will automatically turn off. If this happens, the information entered
during set-up will not have been saved. Please proceed again to set-up
measurement unit, date and time again. · To modify the measurement unit, date
or time, remove the batteries and wait for at least 20 seconds. Then insert
the batteries and reset again.
8
Before using your monitor
5. Set-up Your Personal Data
For body composition measurement, it is necessary to set-up your personal data
(birth date, gender, height). The monitor can store this personal data for up
to 4 persons. · The personal data can be obtained from the app once the app is
paired with your monitor.
1. Press the button to turn on the power.
The power turns on. User ID “1” blinks. Birth date ( ) is displayed.
2. Select and confirm your user ID.
Press the button to select your user ID and press the
button to confirm.
3. Set your birth date.
Press the confirm.
button to set your birth date and press the
button to
· Setting range of year:1900 to 2045.
· While setting the year and date, hold down the rapidly in increments of 10.
button to advance
Year
Month
4. Set your gender.
Day
Press the button to set your gender (MALE) or (FEMALE) and press the button to confirm.
5. Set your height.
Press the button to adjust your height and press the to confirm.
button
· Press continuously to rapidly advance in increments of 1 inch (or 10 cm).
· After all the settings are displayed for your confirmation, “0.0 lb” appears
on the display.
9
6. Step onto your monitor to take a measurement when “0.0 lb” is displayed.
The data of body weight and body composition are recorded in your monitor to
support automatic recognition. After a while, the measurement results are
indicated as follows.
7. Step off your monitor after the measurement results are displayed.
Your measurement is now complete.
8. Press the button (2 seconds or longer) to turn off the power.
To add a new user, start from the “Step 1”.
Operating instructions
6. How to Take a Measurement Accurately
6.1 Correct posture during the measurement
Step onto your monitor with your bare feet. Place the arches of your feet onto
the center of the monitor.
EN
Do not bend your knees during measurement.
Note
· Stepping onto your monitor with socks or footwear on will result in an
inaccurate measurement.
Take a measurement on a hard, level floor.
Caution
· DO NOT place the monitor on a cushioned floor surface such as a carpet or
mat. A correct measurement may not be possible.
10
6.2 Proper storage for “0 lb correction”
This monitor regularly recalibrates automatically when it is not in use. · If
your monitor is placed as shown below and the recalibration function does not
work, implement the
“0 lb correction” before taking measurement. (Refer to Section 6.3.)
Your monitor is leaning against the wall or other objects
Your monitor is placed Your monitor is placed An object is placed
upside down
on an object
on your monitor
6.3 How to implement the “0 lb correction” 1. Place your monitor on a hard, level floor.
2. Press the button to turn on the power.
3. Select your user ID or ” “.
Press the button and then press the
button to confirm.
4. When the “0.0 lb” is displayed, press the
off the power.
button (2 seconds or longer) to turn
This completes the “0 lb correction”. Wait for 5 seconds, and then take a measurement.
Operating instructions
7. Taking a Measurement
When you step onto your monitor, it will be powered on to recognize your user ID automatically and start the measurement.
Wrong user ID may be displayed in the following cases.
· Users of similar body type and body weight are measured.
· Your body weight has changed since last measurement.
A 137.2 lb
B 138.2 lb
C 136.6 lb
C 147.6 lb
1
2
30
16
no 1
no 1
no 3
30 days later
· The measurement results of another user has been set-up. If inaccurate recognition continues, manually select your user ID to take a measurement. (Refer to Section 9.)
11
1. Take a measurement when your monitor is off.
When you step onto your monitor, your monitor automatically turns on.
2. When user ID and measurement results are displayed, the measurement is
complete. Step off your monitor.
3. Confirm your user ID.
If your user ID is correct…
Press the button to confirm your user ID. disappears.
Even if you turn the power off with
blinking,
the results are recorded on the monitor as the
measurement value linked to the displayed user ID.
If your user ID is incorrect…
Before the power turns off, select your user ID
EN
manually with the button, and then press the
button to confirm.
If you confirmed your user ID incorrectly…
Before the power turns off, press the button so that you can select your user ID again.
If “no 1” to “no 4” blinks on the display, or
GUEST is displayed, your personal data has
not been set-up in your monitor.
or
Set-up your personal data.
You can use Guest Mode as well.
12
4. Check the measurement results.
Your results will automatically rotate in the order shown below. Once you
confirm your user ID, you can switch it to a measurement result you want to
view with the button.
Note · The classification indicator can be used as a guide to help understand
your measurement results
for Body Fat Percentage, Visceral Fat Level, Skeletal Muscle Percentage and
BMI. · To better understand your measurement results, refer to the information
and diagrams in Section
20 and 21.
WEIGHT
BMI
BMI Classification
BODY FAT PERCENTAGE
Body Fat Percentage Classification
RESTING METABOLISM
SKELETAL
MUSCLE PERCENTAGE
VISCERAL FAT LEVEL
Visceral Fat Level Classification
Skeletal Muscle Percentage Classification
5. Press the button (2 seconds or longer) to turn off the power.
The power turns off if your monitor is not used for 3 minutes.
Operating instructions
8. View Your Measurement Results on Your Smart Device
Follow the instructions from the compatible OMRON app to view your measurement
results. Then you can confirm the variation of your weight and body
composition parameters on your smart device.
Note · The app must be installed on your smart device. (Refer to Section 3.)
13
Operating instructions
9. Select Your User ID and Take a Measurement
If your user ID is not recognized automatically, you can select your user ID
manually and take the measurement as follows.
1. Press the button to turn on the power.
The power turns on. User ID “1” blinks.
2. Select your user ID.
Select your user ID with the
button.
When the birth date ( ) is displayed, your personal data has not been set-up
in your user ID.
Set-up your personal data. (Refer to Section 5.)
3. Press the button to confirm your user ID.
“0.0 lb” is displayed.
4. Take a measurement when “0.0 lb” is displayed.
Step onto your monitor.
EN
5. Check your measurement results.
Your results will automatically rotate on the display.
6. Press the button (2 seconds or longer) to turn off the power.
The power turns off if your monitor is not used for 3 minutes.
14
Operating instructions
10. Guest Mode (Unrecorded Mode)
When this mode is used, your measurement results will not be recorded.
1. Press the button to turn on the power.
The power turns on. User ID “1” blinks.
2. Select and confirm ”
Select “GUEST” with the
“. button, and then press the
button to confirm.
3. Enter personal data.
3.1 Set your birth date
Press the confirm.
button to set your birth date and press the
button to
· Setting range of year: 1900 to 2045.
· While setting the year and date, hold down the rapidly in increments of 10.
button to advance
Year Month
Day
3.2 Set your gender Press the button to set your gender (MALE) or (FEMALE) and
press the button to confirm.
3.3 Set your height Press the button to set your height and press the button
to confirm. · Press continuously to rapidly advance in increments of 1 inch
(10 cm).
After all the settings are displayed for your confirmation, “0.0 lb” appears
on the display. The power turns off if your monitor is not used for 1 minute
after “0.0 lb” is displayed.
15
4. Start Measurement when “0.0 lb” is displayed.
Step onto your monitor.
5. Check your measurement results.
Your results will automatically rotate on the display.
6. Press the button (2 seconds or longer) to turn off the power.
The power turns off if your monitor is not used for 3 minutes.
Operating instructions
11. Measure Weight Only
When this mode is used, your measurement result will not be recorded.
1. Press the button to turn on the power.
The power turns on. User ID “1” blinks.
EN 2. Select and confirm ” “.
Select ” ” with the button, and then press the button to confirm.
3. When the “0.0 lb” is displayed, step onto your monitor.
4. Check your measurement result.
Your weight is displayed and blinks to indicate that measurement is complete.
5. Press the button (2 seconds or longer) to turn off the power.
The power turns off if your monitor is not used for 3 minutes. 16
Operating instructions
12. Change or Delete Your Personal Data
1. Press the button to turn on the power.
The power turns on. User ID “1” blinks.
2. Select your user ID.
Press the button to select the user ID.
When the birth date ( ) is displayed,
Your personal data is not set-up in your user ID. Set-up your personal data.
(Refer to Section 5.)
3. Press the button to confirm your user ID.
“0.0 lb” is displayed.
4. Press the button.
“CHANGE” and “DEL” blink.
5. Select “CHANGE” or “DELETE” the personal data.
· Even if the personal data is changed, the measurement results will not be
changed or deleted. When using the user ID which has been used by another
person, delete their personal data and then set-up the personal data again.
Change your personal data
(The measurement results won’t be deleted)
1. Press the button to select
“CHANGE”
Delete your personal data
Note:these steps will only delete your data from the monitor. To delete your
data from the app, follow instructions provided in the “support” section of
the app. (The measurement results will also be deleted)
1. Press the button to select “DEL”
2. Press the button
The year blinks.
2. Press the
blinks.
button
3. Change “birth date”, “gender” and
“height” with reference to Step 3 Step 5 of Section 5.
3. Press the
· To stop any change, press the button (2 seconds or longer) to turn off the
power.
· The untransferred measurement results will not be changed.
17
button again
Operating instructions
13. Delete the Communication Setting
If you want to stop the use of the app or delete the communication settings
from your smart device, please operate as follows. All the communication
settings recorded in your monitor will be deleted.
1. Press and hold the button more than 2 seconds.
” ” and the Bluetooth symbol blink.
2. Press and hold the
” ” and “CLr” blink.
button more than 2 seconds again.
3. Press the button to confirm.
The power turns off if your monitor is not used for 10 seconds after “CLr” is
displayed.
Care and maintenance
14. Maintenance and Storage
EN
How to Clean your Monitor
· Before use, wipe your monitor with a soft dry cloth. If necessary, use a
cloth moistened with water or detergent and squeeze it well before wiping your
monitor, then wipe off with a dry cloth.
· Do not use benzene or thinner, or other volatile solvents to clean your
monitor. · Do not wash your monitor with water.
Care and Storage
· Do not store your monitor in the following conditions: – Humidity, where
moisture or water may get into your monitor – High temperatures, direct
sunlight or dusty places – Places with the risk of sudden shocks or vibrations
– In places where chemicals are stored or where corrosive gas is present
· Do not carry out repairs of any kind by yourself. This product is calibrated
at the time of manufacture. If at any time you question the accuracy of
measurements, please contact OMRON customer service.
18
Care and maintenance
15. Troubleshooting
If any of the below problems occur during the measurement, first check that no other electrical device is within 12 inches (30 cm). If the problem persists, refer to the table below.
Error Display
Cause
Correction
You stepped off the monitor during a
measurement of body
composition.
Do not step off the monitor until the measurement of body composition is completed. (Refer to Section 6.)
The soles of your feet are
not in firm contact with the electrodes.
Make sure that you are standing on the monitor correctly by placing the soles
of your feet firmly onto the electrodes when taking a measurement. (Refer to
Section 6.)
The posture for measurement is incorrect, the soles of your feet are not in firm contact with the electrodes or the soles of your feet were dry.
Stand with your knees and back straight. Keep your feet firmly placed on the electrodes and do not move your feet when taking a measurement. (Refer to Section 6.) Slightly moisten the soles of your feet with a wet towel and try again.
After setting the date and time, the monitor was touched or used before the display automatically turned OFF.
Remove and then re-insert the battery. Restart the monitor starting from “Pair
your monitor with Your Smart Device”. (Refer to Section 3.) · When the date
and time are displayed, please leave
the monitor unattended until the power turns off automatically.
Device error.
Remove and then re-insert the battery. Once this is complete, please restart the monitor. If this error continues to display, contact customer service.
Communication failure.
Turn off the power and try to communicate again. If this error is displayed again, contact customer service.
You moved during a measurement.
Stand still during a measurement.
Your body weight was out of the measurable range.
Communication failure.
Confirm the display of your smart device, and follow the instructions in the
app. Refer to the “Help” section in the
app.
Batteries are low. Batteries are depleted.
Recommend to replace the batteries with new ones ahead of time. (Refer to
Section 2.)
Replace the batteries. (Refer to Section 2.)
19
Problem
Cause
Correction
24-29 sets of measurements Transfer the measurement results to the
results have been stored.
app, then the symbol will disappear.
blinks
30 sets of measurements results have been stored.
You pressed and held the button more than 2 seconds.
If the number exceeds 30, the oldest results are deleted.Transfer the
measurement results to the app, then the symbol will disappear.
This is displayed when you pair your monitor with your smart device. Follow
the instructions on the app. Press the
button (2 seconds or longer) to stop the pairing.
Even if you turn on the power, nothing is displayed. Even if you step onto the
monitor, nothing is displayed.
After replacing the batteries, nothing is displayed when stepping onto the
monitor.
”
” is displayed
for some results.
You pressed the button.
You pressed and held the button more than 2 seconds when ” ” and the Bluetooth
symbol were blinking.
No batteries are inserted. The batteries are inserted in the wrong direction.
This is displayed when the data is transferred to your smart device. Follow
the instructions on the app. Press the
button (2 seconds or longer) to stop the transmission.
This is displayed when you delete the communication setting. (Refer to Section
13.)
Press the button (2 seconds or longer) to stop the operation.
Insert the batteries.
Insert the batteries in the correct
EN
direction.
The batteries are worn out. Replace all four batteries with new ones.
You didn’t set the measurement unit, date and time after replacing the batteries.
Set the measurement unit, date and time. (Refer to Section 4.)
Your body weight is too low to
automatically turn on the unit. (Less than 26.4lb.)
Select user ID before taking a measurement.
The set-up data or body composition values were out of the measurable range.
Check whether the settings of birth date,
gender, and height are correct. Even if
these settings are correct, ”
”
is displayed if they are out of the
displayable or supported age range.
20
Problem
Cause
Correction
Your posture is wrong during Take a measurement with a correct
a measurement.
posture.
You take a measurement on
a carpet or cushioned floor
surface, or an uneven floor.
Your measurement
Your body and the soles of
result is higher or lower your feet are cold, impairing
than the actual value. blood circulation.
Your result varies widely
for each measurement. The foot electrodes are very
cold.
Ensure the monitor is correctly placed on a hard, level floor.
Warm your body to get blood circulation back to normal before taking a
measurement.
Leave the monitor in a warm room for a while before taking a measurement.
The soles of your feet are dry.
Slightly moisten soles of your feet with a wet towel before taking a measurement.
The “0 lb correction” was not Implement the “0 lb correction”.
implemented correctly.
(Refer to Section 6.3.)
The incorrect user ID is displayed when you step onto the monitor.
Your body weight has changed notably since your last measurement.
Your body type is similar to another set-up person.
Select user ID before taking a measurement. (Refer to Section 9.)
The measurement results of another user has been set-up.
You want to measure the body composition, but only the body weight is
User ID or GUEST is not selected. (User ID or GUEST
displayed.
is not displayed.)
Select user ID or GUEST before taking a measurement.
You pressed a button when you stood on the monitor.
Step off the monitor, and then press a button.
A button does not respond.
The button is wet.
Wipe off the water or stain before taking a measurement.
You pressed two or more buttons simultaneously.
Press one button at a time.
Even if you do nothing,
the power turns off.
Refer to “About the Power OFF Function”. (Refer to Section 2.)
Failure to send data.
Refer to the “Help” section in the app.
If the above corrections are not effective, contact us at 1-800-634-4350.
21
Care and maintenance
16. Specifications
Product Name
OMRON Body Composition Monitor and Scale with Bluetooth®
Model #
BCM-500 REF HBF-222T-Z
Display*
Body Weight:
4.4 to 330.0 lb with an increment of 0.2 lb (0 st 4.4 lb to 23 st 8.0 lb with an increment of 0.2 lb) (2.0 to 150.0 kg with an increment of 0.1 kg)
Body Fat percentage:
5.0 to 60.0% with an increment of 0.1%
Skeletal Muscle percentage:
5.0 to 50.0% with an increment of 0.1%
BMI:
7.0 to 90.0 with an increment of 0.1
Resting Metabolism: 385 to 3999 kcal with an increment of 1 kcal
Visceral Fat Level: 30 levels with an increment of 1 level
Body fat percentage, Skeletal muscle percentage and BMI classification: (Low) / 0 (Normal) / + (High) / ++ (Very High) 4 levels
Visceral fat level classification: 0 (Normal) / + (High) / ++ (Very High) 3 levels
- The age range for the Body Fat percentage and Body fat percentage
classification is 10 to 80 years old. * The age range for the Skeletal Muscle percentage, Skeletal Muscle
percentage classification, Visceral Fat level, Visceral Fat level classification and Resting Metabolism is 18 to 80 years old.
Transmission Protocol Bluetooth® low energy technology
Wireless
Frequency range:
2.4 GHz (2400 – 2483.5 MHz)
communication
Modulation:
GFSK
Effective radiated power:
<20 dBm
EN
Setting Items*
The following information can be stored for up to 4 persons.
Measurement unit lb&inch / st-lb&inch / kg&cm
Birth date
January 1st, 1900 to December 31st, 2045
Gender
Male / Female
Height
3′ 4″ to 6′ 6 1/2″ with an increment of 1/4″ (100.0 to 199.5 cm with an increment of 0.5 cm)
Weight Accuracy
Accuracy (S.E.E.) Durable Period
- When the height of a person is less than 3′ 4″ or more than 6′ 6 1/2″: BMI and body composition measurement results are for reference.
4.4 lb to 88.2 lb: ± 0.88 lb (4.4 lb to 6 st 4.2 lb: ± 0.88 lb) (2.0 kg to 40.0 kg: ± 0.4 kg)
88.2 lb to 330.0 lb: ± 1% (6 st 4.2 lb to 23 st 8.0 lb: ± 1%) (40.0 kg to 150.0 kg: ± 1%)
Body Fat percentage:
3.5%
Skeletal Muscle percentage: 3.5%
Visceral Fat Level:
3 levels
5 years
22
IP Classification
IP21*
- IP classification is degrees of protection provided by enclosures in accordance with IEC 60529. This device is protected against solid foreign
objects of 12.5 mm diameter and greater such as a finger. This device is protected against vertically falling water drops which may cause issues
during a normal operation.
Power Supply
4 AAA alkaline batteries (LR03)
Battery Life
Approximately 6 months (When AAA alkaline batteries are used in four measurements, four data transfers and four persons a day at a room temperature of 73.4 °F (23 °C))
Operating Temperature/ +41°F to +104°F (+5°C to +40°C), 30 to 85% RH (no- condensing), Humidity/Air Pressure 860 – 1060 hPa
Storage and Transport 4°F to +140°F (20°C to +60°C), 10 to 95% RH (no- condensing),
Temperature/
860 – 1060 hPa
Humidity/Air Pressure
Weight
Approximately 3 5/9 lb (including batteries)
External Dimensions Approximately 11.2″(W)×1.1″(H)×11″(D)
Contents
Body Composition Monitor and Scale with Bluetooth®,
4 AAA alkaline batteries (LR03),
Quick Start Guide, Instruction Manual
- S.E.E: standard error of estimation
Note · Subject to technical modification without prior notice.
This Product operates in the unlicensed ISM band at 2.4GHz. In the event this
Product is used near other wireless devices including microwave and wireless
LAN, which operate same frequency band of this Product, there is a possibility
that interference occurs between this Product and such other devices. If such
interference occurs, please stop the operation of other devices or relocate
this Product before using this Product or do not use this Product around the
other wireless devices.
The Bluetooth® word mark and logos are registered trademarks owned by
Bluetooth SIG, Inc. and any use of such marks by OMRON HEALTHCARE Co., Ltd. is
under license. Other trademarks and trade names are those of their respective
owners.
23
Care and maintenance
17. FCC Statement
FCC CAUTION Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note · This equipment has been tested and found to comply with the limits for
a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
EN · Reorient or relocate the receiving antenna. · Increase the separation
between the equipment and receiver. · Connect the equipment into an outlet on
a circuit different from that to which
the receiver is connected. · Consult the dealer or an experienced radio/TV
technician for help.
This transmitter must not be co-located or operated in conjunction with any
other antenna or transmitter.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment and meets the FCC radio frequency (RF) Exposure
Guidelines. This equipment has very low levels of RF energy that are deemed to
comply without testing of specific absorption ratio (SAR).
24
Care and maintenance
18. Limited Warranty
Your BCM-500 Body Composition Monitor and Scale with Bluetooth®, excluding the batteries, is warranted to be free from defects in materials and workmanship appearing within 1 year from the date of purchase, when used in accordance with the instructions provided with the monitor. The above warranty extends only to the original retail purchaser, and only to products purchased from an Omron authorized seller who is subject to and follows Omron’s quality control standards, unless otherwise prohibited by law.
We will, at our option, replace without charge any monitor covered by the
above warranty. Replacement is our only responsibility and your only remedy
under the above warranty. To obtain warranty service contact Customer Service
by calling 1-800-634-4350 for the
address of the inspection center and the return shipping and handling fee.
Enclose the original printed receipt. Include a letter, with your name,
address, phone number, and description of the specific problem. Pack the
product carefully to prevent damage in transit. Because of possible loss in
transit, we recommend insuring the product with return receipt requested.
THE FOREGOING IS THE SOLE WARRANTY PROVIDED BY OMRON IN CONNECTION WITH THIS
PRODUCT, AND OMRON HEREBY DISCLAIMS ANY OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE. IMPLIED WARRANTIES AND OTHER TERMS THAT MAY BE IMPOSED BY LAW, IF
ANY, ARE LIMITED IN DURATION TO THE PERIOD OF THE ABOVE EXPRESS WARRANTY.
OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER SPECIAL, INCIDENTAL,
CONSEQUENTIAL OR INDIRECT COSTS, EXPENSES OR DAMAGES.
This warranty provides you with specific legal rights, and you may have other
rights that vary by jurisdiction. Because of special local requirements, some
of the above limitations and exclusions may not apply to you.
Visit our web site at: Call toll free:
FOR CUSTOMER SERVICE OmronHealthcare.com 1-800-634-4350
25
Care and maintenance
19. Guidance and Manufacturer’s Declaration
OMRON Battery-operated Body Composition Monitor and Scale with Bluetooth®
Information for Accompanying Documents in the Scope of IEC60601-1-2:2014
Important information regarding Electro Magnetic Compatibility (EMC)
BCM-500 manufactured by OMRON HEALTHCARE Co., Ltd. conforms to
IEC60601-1-2:2014 Electro Magnetic Compatibility (EMC) standard. Further
documentation in accordance with this EMC standard is available at
OmronHealthcare.com/emc. Refer to the EMC information for BCM-500 on the
website.
EN
26
Information on body composition
20. Information on Body Composition
Principle of body composition calculation
Body fat has low electric conductivity
The BCM-500 measures the body fat percentage by the Bioelectrical Impedance
(BI) method. Muscles, blood vessels and bones are body tissues with a high
water content that conducts electricity easily. Body fat is tissue that has
little electric conductivity. The BCM-500 sends an extremely weak electrical
current of 50 kHz and less than 500 µA through your body to determine the
amount of fat tissue. This weak electrical current is not felt while operating
the BCM-500. In order for the scale to determine your body composition, it
uses the electrical impedance, along with your height, weight, age and gender
information to generate results based on OMRON’s data of body composition.
Recommended measurement times
Understanding the normal changes in your body fat percentage can help you in
preventing or reducing obesity. Being aware of the times when the body fat
percentages shift within your own daily schedule will assist you in obtaining
an accurate trending of your body fat. It is recommended to use this monitor
in the same environment and daily circumstances. (See chart)
Daily activities Waking up
Recommended time Breakfast 2 hours
Recommended time
Lunch 2 hours
Recommended time
Taking a bath or eating dinner 2 hours
Recommended time Going to bed
After waking up
Before lunch and about 2 hours or more after breakfast
In the afternoon about 2 hours or more after lunch and before taking a bath or
eating dinner
Avoid measurement immediately after eating or bathing. Before going to bed and
about 2 hours or more after dinner or bath
Avoid taking measurements under the following conditions: – Immediately after
vigorous exercise, after a bath or sauna. – After drinking alcohol or a large
amount of water, after a meal (about 2 hours). If a measurement is taken under
these physical conditions, the calculated body composition may differ
significantly from the actual one because the water content in the body is
changing.
What is BMI (Body Mass Index)?
BMI uses the following simple formula to indicate the ratio between weight and
height of a person.
BMI = weight (lb) / height (inches) / height (inches) × 703
The OMRON BCM-500 uses the height information stored in your user ID or when
entering information in the Guest Mode to calculate your BMI classification.
If the fat level revealed by BMI is higher than the international standard,
there is an increased likelihood of common diseases. However, not all types of
fat can be revealed by BMI.
27
What is Body Fat Percentage?
Body fat percentage refers to the amount of body fat mass in regards to the
total body weight expressed as a percentage.
Body fat percentage (%) = {Body fat mass (lb) / Body weight (lb)} × 100
The BCM-500 uses the BI method to estimate your body fat percentage. Depending
on where the fat is distributed in the body, it is classified as visceral fat
or subcutaneous fat.
What is Visceral Fat Level?
Visceral fat = fat surrounding internal organs
Too much visceral fat is thought to be closely linked to increased levels of
fat in the bloodstream, which can lead to common diseases such as
hyperlipidemia and diabetes, which impairs the ability of insulin to transfer
energy from the bloodstream and using it in cells. In order to prevent or
improve conditions of common diseases, it is important to try and reduce
visceral fat levels to an acceptable level. People with high visceral fat
levels tend to have large stomachs. However, this is not always the case and
high visceral fat levels can lead to metabolic obesity. Metabolic obesity
(visceral obesity with normal weight) represents fat levels that are higher
than average, even if a person’s weight is at or below the standard for their
height.
Visceral Fat Subcutaneous Fat
Spine Sample Visceral Fat (MRI image)
What is Subcutaneous Fat? Subcutaneous fat = fat below the skin
Visceral Fat Subcutaneous Fat
Subcutaneous fat not only accumulates around the stomach but also around the
upper arms, hips and thighs, and can cause a distortion of the body’s
proportions. Although not directly linked to increased risk of disease, it is
thought to increase pressure on the heart and other complications.
Subcutaneous fat is not displayed in this monitor, but is included in the body
fat percentage.
What is Skeletal Muscle?
EN
Spine Sample Subcutaneous Fat (MRI image)
Muscle is divided into two types, muscle in internal organs, such as the heart, and skeletal muscle attached to bones that is used to move the body. Skeletal muscle can be increased through exercise and other activity. Increasing the ratio of skeletal muscle means that body can burn energy more easily, which means that it is less likely to turn to fat, and makes it easier to lead an energetic lifestyle.
What is Resting Metabolism?
Regardless of your activity level, a minimum level of caloric intake is
required to sustain the body’s everyday functions. Known as the resting
metabolism, this indicates how many calories you need to ingest in order to
provide enough energy for your body to function.
28
Information on body composition
21. Measurement Results Interpretation Diagrams
Interpreting the Body Fat Percentage Result
Female Male
Age 10 11 12 13 14 15 16 17 18 – 39 40 – 59 60 – 80 10 11 12 13 14 15 16 17 18 – 39 40 – 59 60 – 80
-(Low) < 16.1% < 16.3% < 16.4% < 16.4% < 16.3% < 16.1% < 15.8% < 15.4% < 21.0% < 23.0% < 24.0% < 12.8% < 12.6% < 12.3% < 11.6% < 11.1% < 10.8% < 10.4% < 10.1% < 8.0% < 11.0% < 13.0%
0(Normal) 16.1 – 32.2% 16.3 – 33.1% 16.4 – 33.5% 16.4 – 33.8% 16.3 – 34.0% 16.1 – 34.2% 15.8 – 34.5% 15.4 – 34.7% 21.0 – 32.9% 23.0 – 33.9% 24.0 – 35.9% 12.8 – 27.9% 12.6 – 28.5% 12.3 – 28.2% 11.6 – 27.5% 11.1 – 26.4% 10.8 – 25.4% 10.4 – 24.7% 10.1 – 24.2% 8.0 – 19.9% 11.0 – 21.9% 13.0 – 24.9%
+(High) 32.3 – 35.2% 33.2 – 36.0% 33.6 – 36.3% 33.9 – 36.5% 34.1 – 36.7% 34.3 – 36.9% 34.6 – 37.1% 34.8 – 37.3% 33.0 – 38.9% 34.0 – 39.9% 36.0 – 41.9% 28.0 – 31.8% 28.6 – 32.6% 28.3 – 32.4% 27.6 – 31.3% 26.5 – 30.0% 25.5 – 28.7% 24.8 – 27.7% 24.3 – 26.8% 20.0 – 24.9% 22.0 – 27.9% 25.0 – 29.9%
Classified by OMRON HEALTHCARE Co., ltd. based on the papers below. · HD McCarthy et al, in the International Journal of Obesity, Vol. 30, 2006. · Gallagher et al., American Journal of Clinical Nutrition, Vol. 72, Sept. 2000
++(Very High)
35.3% 36.1% 36.4% 36.6% 36.8% 37.0% 37.2% 37.4% 39.0% 40.0% 42.0% 31.9% 32.7%
32.5% 31.4% 30.1% 28.8% 27.8% 26.9% 25.0% 28.0% 30.0%
Interpreting the Visceral Fat Level Result
Visceral Fat Level 1 – 9
10 – 14 15 – 30
Level Classification 0 (Normal) + (High)
++ (Very High)
Classified based on OMRON HEALTHCARE Co., Ltd. study data.
29
Interpreting the Skeletal Muscle Percentage Result
Female Male
Age 18 – 39 40 – 59 60 – 80 18 – 39 40 – 59 60 – 80
-(Low) < 24.3% < 24.1% < 23.9% < 33.3% < 33.1% < 32.9%
0(Normal) 24.3 – 30.3% 24.1 – 30.1% 23.9 – 29.9% 33.3 – 39.3% 33.1 – 39.1% 32.9 – 38.9%
Classified based on OMRON HEALTHCARE Co., Ltd. study data.
+(High) 30.4 – 35.3% 30.2 – 35.1% 30.0 – 34.9% 39.4 – 44.0% 39.2 – 43.8% 39.0 – 43.6%
++(Very High)
35.4% 35.2% 35.0% 44.1% 43.9% 43.7%
Interpreting the BMI Result
BMI < 18.5 18.5 – 24.9 25 – 29.9 30
BMI (Designation by the WHO) – (Underweight) 0 (Normal) + (Overweight) ++ (Obese)
Source: Values for obesity judgment proposed by WHO, the World Health Organization.
EN
30
OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, Kyoto, 617-0002
JAPAN
Distributed by: OMRON HEALTHCARE, INC. 1925 West Field Court, Lake Forest, IL
60045 U.S.A.
OmronHealthcare.com © 2021 OMRON HEALTHCARE, INC.
Made in China
References
- OMRON Blood Pressure Monitors | Health & Wellness Products
- OMRON Apps for Connected Products & Bluetooth Devices
- Symbols Glossary | OMRON Healthcare
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>