Braeburn 3020 Non-Programmable Thermostats Instructions
- June 6, 2024
- Braeburn
Table of Contents
Detailed User Manual
PREMIER SERIES
Non-Programmable Thermostats
3020 For Systems Up to 2 Heat / 1 Cool
3220 Up to 3 Heat / 2 Cool Heat Pump
Up to 2 Heat / 2 Cool Conventional
Read all instructions before proceeding.
User Manual
Congratulations! You are in control of one of the easiest-to-use thermostats on the market today. This thermostat has been designed to provide you with years of reliable performance and comfort control.
Features
- SpeedBar®Multi-Function Button simplifies programming and setting changes.
- The large 4 sq. in. bright blue backlit display is easy to read.
- Extra-large display characters make viewing settings even easier.
- User-selectable service monitors remind you of required system maintenance.
- Precise temperature accuracy keeps you in control of your comfort.
- Optional indoor or outdoor remote sensing
- Convenient circulating fan mode
About Your Thermostat
1. Room Temperature | Displays the current room temperature |
---|---|
2. Set Temperature | Displays the current setpoint temperature |
3. Reset Button | .Resets current time, program, and user settings |
4. SYSTEM Button | Selects the system you want to control |
5. BACK Button | Moves back in installer/user setup modes |
6. NEXT Button | Moves back in installer/user setup modes |
7. RETURN Button | Returns to normal mode from installer/user setup modes |
8. Service Indicators | Displays various service/maintenance information |
9. FAN Button | Selects the system fan mode |
10. Quick Reference Instructions | Stored in the slot located at top of the |
thermostat
11. Low Battery Indicator| Indicates when the batteries need to be replaced
12. Fan Indicator| Indicates when the system fan is running
13. System Status Indicator| Displays information about the status of the
system
14. Lock Mode Indicator| Indicates if the thermostat is locked
15. SpeedBar®| Increases or decreases settings (time, temperature, etc.)
16. Outdoor Temperature Indicator
Battery Compartment| .Displays along with the outdoor temperature reading (see
note below
Located in the back of thermostat
NOTE : If a Braeburn® outdoor sensor was connected you can view the outdoor temperature by pressing th e BACK and NEXT buttons at the same time.
Setting User Options
Advanced User Options
User options allow you to customize some of your thermostat’s features. Most
users will not need to make any changes to the settings in this section.
To enter the User Options menu, press and hold the RETURN button for
approximately 3 seconds until the screen changes and displays the first User
Option.
Press the SpeedBar ®up or down to change the setting for the displayed User
Option. After you have changed your desired setting, press NEXT to advance to
the next User Option. You may also press BACK to move backward through the
User Options.
When your changes are complete, press RETURN to exit.
Table of User Options
NOTE: A detailed description of each User Option follows this table.
No.| User Options| Factory Default| Setting Options|
Comments| Pg.
---|---|---|---|---|---
1| Filter Service Monitor| OFF| OFF| Disables filter service monitor feature.|
8
30, 60, 90,
120.180. 365
| Selects a number of days that must pass before the thermostat will flash a
Service Filter reminder in the display screen.
2| UV Light Service Monitor| OFF| OFF| Disables UV service monitor feature.| 8
180, 365| Selects a number of days before the thermostat will flash a Service
UV reminder in the display screen.
3| Humidifier Pad Service Monitor| OFF| OFF| Disables pad service monitor
feature.| 8
180, 365| Selects a number of days before the thermostat will flash a Service
Humid reminder in the display screen.
4| SetPoint Adjustment Limit*| 0 ROJ| 0,1, 2, or 3 ROLJ 0| Selects a
temperature adjustment limit of 0 (disabled), 1°, 2°, or 3°.| 8
5| Thermostat Lock Code| 000| 0-9| Select a 3 digit lock code of 0-9 for each
digit.| 9
- For this option to be available, the thermostat must be set to security level 1 (See Installer Manual).
Service Monitors
(Filter, UV and Humidifier Pad)
User Options 1, 2 and 3
There are three user-selectable service monitors that will display reminders
for a required air filter, UV bulb, or humidifier pad replacement. The SERVICE
segment flashes in the display long with FILTER, UV or HUMID. When the service
interval has been reached and the required cleaning or replacement has been
performed, press the RETURN button to reset the timer. Select OFF or a set
number of days before the reminder will appear.
Set Point Adjustment Limit
User Option 4
The Set Point Adjustment Limit will limit how much the temperature can be
adjusted from the current setpoint when the thermostat is locked with security
level 1(See Installer Manual). This setting will not allow the user to
override the temperature past the selected limit amount of 1, 2 or 3 degrees
from the current set point. When the user reaches the adjustment limit the
screen will flash ADJ. A setting of 0 disables the adjustment limit.
Thermostat Lock Code
User Option 5
The Thermostat Lock Code sets a 3-digit code that you may use at any time to
lock or unlock the thermostat.
Setting the code in the user options mode does not activate the lock feature
(See Locking/Unlocking Thermostat, page 15). You may choose a 3-digit code
with each digit being 0-9.
Operating Your Thermostat
Setting the SYSTEM Control Mode
The System Control has 5 modes of operation – AUTO, COOL, OFF, HEAT, and EMER.
The mode can be selected by pressing the SYSTEM button to scroll through the
different modes.
NOTE: Depending on how your thermostat was configured, some system modes
may not be available.
AUTO The system will cycle between heating and cooling automatically
based on your program setpoints.
AUTO will be displayed with either HEAT or COOL.
COOL, Only your cooling system will operate.
OFF Heating and cooling systems are off.
HEAT Only your heating system will operate
EMER Operates a backup heat source (Emergency Heat)for heat pump systems
only.
Setting the FAN Control Mode
The Fan Control has 3 modes of operation – AUTO, ON, and CIRC. The mode can be
selected by pressing the FAN button to scroll through the different modes.
NOTE: Depending on how your thermostat was configured, some fan modes may
not be available.
AUTO The system fan will run only when your heating or cooling system is
running.
ON The system fan stays on.
CIRC The system fan will run from time to time to help circulate air and
provide more even temperatures when the heating or cooling system is not
active.
Setting the Temperature
Temperature Adjustment – Press the SpeedBar® up or down to adjust the current set temperature.
Status Indicators
Status indicators appear in the display to let you know if
your system is heating, cooling or off.
HEAT ON Indicates that your heating system is running.
COOL ON Indicates that your cooling system is running.
AUX Indicates that the auxiliary stage of heating is running (multi-stage
heat pump systems only).
EMER Indicates that the emergency heating system is running (heat pump
systems only).
CHECK Indicates that there is a potential problem with your system.
Contact a local service technician.
(Model 3220 only)
SERVICE Indicates a user-selectable service reminder for changing a
filter, UV air purifier bulb, or humidifier pad (See Service Monitors, page
8).
|
---|---
Resetting the Thermostat
This thermostat provides you with a reset button that will erase all of your
user settings. The reset feature does not affect the Installer Settings.
To reset the thermostat, use a small object such as a toothpick or paperclip
and gently press the button located inside the small hole on the front of the
thermostat housing labeled “reset”.
NOTE: You cannot reset the thermostat if it is locked.
Additional Operation Features
Auto Changeover Mode
Auto Changeover mode is a feature enabled/disabled in the Installer Settings
(see Installer Manual). If enabled, it is selected by pressing the SYSTEM
button until AUTO HEAT or AUTO COOL appears in the display.
When Auto Changeover mode is enabled and selected, the system automatically
switches between heating and cooling when the room temperature meets the
programmed heating or cooling setpoints. To operate properly, the thermostat
requires a “dead band” setting to eliminate program conflicts. The dead band
is set in the Installer Settings (See Installer Manual). The default setting
is 3° F. Therefore, you will not be able to set your heat or cool temperature
within 3° F of each other. If a setting is made in either heating or cooling
which violates the dead band, the opposite mode will adjust up or down
automatically to maintain the programmed dead-band spacing.
Compressor Protection
Compressor protection is enabled/disabled in the Installer Settings (See
Installer Manual). If enabled, this feature is automatically present in
cooling and/or heating (heat pump only) modes.
This thermostat includes an automatic compressor protection delay to avoid
potential damage to your system from short cycling. This feature activates a
short delay after turning off the system compressor.
Additionally, for multi-stage heat pump systems, this thermostat provides cold
weather compressor protection by locking out the compressor stage(s) of
heating for a period of time after a power outage greater than 60 minutes.
This cold weather compressor protection can be manually overridden at any time
by changing the system mode to OFF momentarily, then back to HEAT.
Locking and Unlocking the Thermostat
Your 3-digit Lock Code is set in the “User Options” portion of this manual
(See “Setting User Options”, pages 7 and 9).
Once the code is set, the thermostat can be locked or unlocked at any time by
entering that code.
To lock or unlock the thermostat, press and hold the NEXT and R ETURN
buttons together for 5 seconds (Figure 1).
The screen will change, displaying 000 and LOCK will be flashing (Figure 2).
Press the SpeedBar® up or down to enter the first digit of your lock code and
then press NEXT to advance to the next digit. Repeat this process to enter the
second and third digits of your lock code. After entering the third digit,
press RETURN.
|
---|---
AC Power Monitor
The AC Power Monitor feature is enabled in the Installer Settings (See
Installer Manual). If enabled, this feature will automatically be present.
If your thermostat was hardwired (power provided from the system with
batteries as a backup) then the AC Power Monitor feature will indicate when a
loss of power to the thermostat has occurred by displaying NO POWR.
Indoor Remote Sensing
Indoor remote sensing is achieved by installing a Braeburn®remote indoor
sensor and is configured in the Installer Settings (See Installer Manual).
If a Braeburn indoor remote sensor was installed and properly configured in
the Installer Settings, the thermostat will sense temperature at a remote
location or at a combination of a remote location and the thermostat location.
Outdoor Remote Sensing
Outdoor remote sensing is enabled by installing an aBraeburn®remote outdoor
sensor. No additional configuration is required.
If a Braeburn outdoor remote sensor was installed you may press the BACK and
NEXT buttons at the same time to view the outdoor temperature.
|
---|---
Thermostat Maintenance
Thermostat Cleaning
Never spray any liquid directly on the thermostat. Using a soft damp cloth
wipe the outer body of the thermostat.
Never use any abrasive cleaners to clean your thermostat.
Changing the Batteries
This thermostat requires two (2) properly installed “AA” alkaline batteries to
provide power for the thermostat if 24 volt AC power is not connected. (See
Installer Manual).
If batteries become low, a battery indicator will appear in the display. You
should change your batteries immediately when you see the low battery signal
by following these instructions.
- Remove thermostat body by gently pulling it from the base.
- Remove old batteries and replace them with new batteries.
- Make sure to correctly position the (+) and (-) symbols.
- Gently push the thermostat body back onto the base.
NOTE: We recommend replacing the thermostat batteries annually or if the thermostat will be unattended for an extended period of time.
Limited Warranty
When installed by a professional contractor, this product is backed by a 5-year limited warranty. Limitations apply. For limitations, terms, and conditions, you may obtain a full copy of this warranty:
- Visit us online: www.braeburnonline.com/warranty
- Phone us: 866.268.5599
- Write us: Braeburn Systems LLC
2215 Cornell Avenue
Montgomery, IL 60538
Store this manual for future reference
Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S.)
630-844-1968 (Outside the U.S.)
©2020 Braeburn Systems LLC • All Rights Reserved.
3020W-110-03
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>