Important Safety Instructions
Notice
The RS232 connection should be handled by authorized persons only
WARNING: There are no user serviceable parts inside. Refer all servicing
to qualified service personnel.
WARNING: To reduce the risk of fire or electric shock, do not expose the
unit to moisture or water. Do not expose the unit to dripping or splashing. Do
not place objects filled with liquids, such as vases, on the unit. Do not
allow foreign objects to get into the enclosure. If the unit is exposed to
moisture, or a foreign object gets into the enclosure, immediately disconnect
the power cord from the wall. Take the unit to a qualified service person for
inspection and necessary repairs.
Read these instructions.
Keep these instructions.
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with dry cloth.
Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
Do not install near any heat sources such as radiators, heat registers,
stoves, or other apparatus (including amplifiers) that produce heat.
Do not defeat the safety purpose of the polarized or grounding-type plug. A
polarized plug has two blades with one wider than the other.
A grounding type plug has two blades and a third grounding prong.
The wide blade or the third prong are provided for your safety. If the
provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
Protect the power cord from being walked on or pinched particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
Only use attachments/accessories specified by the manufacturer.
Use only with the cart, stand, tripod, bracket, or table specified by the
manufacturer, or sold with the apparatus. When a cart is used, use with
caution when moving the cart/apparatus combination to avoid injury from tip-
over.
Unplug this apparatus during lightning storms or when unused for long periods
of time.
Refer all servicing to qualified service personnel. Servicing is required when
the apparatus has been damaged in any way, such as powersupply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus,
the apparatus has been exposed to rain or moisture, does not operate normally,
or has been dropped.
The apparatus should be used in non tropical climate.
The ventilation should not be impeded by covering the ventilation openings
with items, such as newspapers, table-cloths, curtains, etc.
No naked flame sources, such as lighted candles, should be placed on the
apparatus.
Touching uninsulated terminals or wiring may result in an unpleasant
sensation.
You must allow a minimum 10 cm or 4 inches of unobstructed clearance around
the unit.
WARNING: The rear panel power cord connector is the mains power disconnect device. The device must be located in an open area that allows access to the cord connector.
The unit must be connected to a power supply only of the type and voltage
specified on the rear panel. (USA: 120 V/60Hz, EC: 230V/50Hz) Connect the
component to the power outlet only with the supplied
power supply cable or an exact equivalent. Do not modify the supplied cable.
Do not use extension cords.
The mains plug is the disconnect of the unit. In order to completely
disconnect the unit from the supply mains, remove the main plug from the unit
and the AC power outlet. This is the only way to completely remove mains power
from the unit.
Use Class 2 wiring for speaker connections to ensure proper installation and
minimize the risk of electrical shock.
The batteries in the remote control should not be exposed to excessive
temperature such as sunshine, fire or other heat sources. Batteries should be
recycled or disposed as per state and local guidelines.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following to conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
RISK OF ELECTRIC SHOCK DO NOT OPEN
WARNING : SHOCK HAZARD-DO NOT OPEN
APPLICABLE FOR USA, CANADA OR WHERE APPROVED FOR THE USAGE
CAUTION: TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE
SLOT. INSERT FULLY.
ATTENTION: POUR EVITER LES CHOCS ELECTRIQUES, INTRODUIRE LA LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRESPONDANTE DE LA PRISE ET POUSSER JUSQU AU FOND.
This symbol is to alert the user to the presence of uninsulated dangerous
voltages inside the product’s enclosure that may constitute a risk of electric
shock.
This symbol is to alert the user to important operating and maintenance
(service) instructions in this manual and literature accompanying the product.
Rotel products are designed to comply with international directives on the Restriction of Hazardous Substances (RoHS) in electrical and electronic equipment and the disposal of Waste Electrical and Electronic Equipment (WEEE). The crossed wheelie bin symbol indicates compliance and that the products must be appropriately recycled or processed in accordance with these directives.
This symbol means that this unit is double insulated.
An earth connection is not required.
Figure 1: Controls and Connections
Figure 2: Remote Control RR-AX1400
Figure 3: Preamp Input and Speaker Output Connections
Figure 4: Digital Input Connections
Figure 5: 12V Trigger Connections
Important Notes
When making connections be sure to:
-
Turn off all the components in the system before hooking up any components, including loudspeakers.
-
Turn off all components in the system before changing any of the connections to the system.
It is also recommended that you: -
Turn the volume control of the amplifier all the way down before the amplifier is turned on or off.
About Rotel
Our story began over 60 years ago. Over the decades, we have received hundreds
of awards for our products and satisfied hundreds of thousands of people who
take their entertainment seriously – like you.
Rotel was founded by a family whose passionate interest in music led them to
manufacture high-fidelity components of uncompromising quality.
Through the years, that passion has remained undiminished and the family goal
of providing exceptional value for audiophiles and music lovers, regardless of
their budget, is shared by all Rotel employees.
Rotel’s engineers work as a close team, listening to, and fine tuning, each
new product until it reaches their exacting musical standards. They are free
to choose components from around the world in order to make that product the
best they can. You are likely to find capacitors from the United Kingdom and
Germany, semiconductors from Japan or the United States, while toroidal power
transformers are manufactured in Rotel’s own factory.
We all have concerns about our environment. And, as more and more electronics
are produced it is especially important for a manufacturer to do all it can to
engineer products that have a minimum impact on the environment.
At Rotel, we are proud to do our part. We have reduced the lead content in our
products by using special lead-free ROHS solder and components.
Our engineers continually strive to improve power supply efficiency without
compromise to quality. When in standby mode Rotel products use minimal power
to meet global Standby Power Consumption requirements.
The Rotel factory is also doing their part to help the environment through
constant improvements to product assembly methods for a cleaner and greener
manufacturing processes.
All of us at Rotel thank you for buying this product. We are sure it will
bring you many years of enjoyment.
Getting Started
Thank you for purchasing the Rotel A14MKII Stereo Integrated Amplifier.
When used in a high-quality music audio system, Rotel products will provide
years of musical enjoyment.
This amplifier is a full featured, high performance component. All aspects of
the design have been optimized to retain the full dynamic range and subtle
nuances of your music. The unit has a highly regulated power supply
incorporating a Rotel custom-designed toroidal power transformer. This low
impedance power supply has ample power reserves, which enables the amplifier
to easily reproduce the most demanding audio signals. This type of design is
more expensive to manufacture, but it is better for the music.
The printed circuit boards (PCB) are designed with Symmetrical Circuit Traces.
This ensures that the precise timing of the music is maintained and faithfully
recreated. The circuitry uses metal film resistors and polystyrene or
polypropylene capacitors in important signal paths. All aspects of this design
have been examined to ensure the most faithful music reproduction.
The main functions of the A14MKII are easy to install and use. If you have
experience with other stereo systems, you shouldn’t find anything perplexing.
Simply plug in the associated components and enjoy.
A Few Precautions
WARNING: To avoid potential damage to your system, turn off ALL the components in the system when connecting or disconnecting the loudspeakers or any associated components. Do not turn the system components back on until you are sure all the connections are correct and secure. Pay particular attention to the speaker wires. There must be no loose strands that could contact the other speaker wires, or the chassis of the amplifier.
Please read this manual carefully. It provides information on how to
incorporate the unit into your system as well as information that will help
you get optimum sound performance. Please contact your authorized Rotel dealer
for answers to any questions you might have. In addition, all of us at Rotel
welcome your questions and comments.
Save the shipping carton and all enclosed packing material for future use.
Shipping or moving the amplifier in anything other than the original packing
material may result in severe damage to your amplifier.
If included in the box please complete the owner’s registration card or
register on line. Also be sure to keep the original sales receipt. It is your
best record of the date of purchase, which you will need in the event warranty
service is ever required.
Placement
Like all audio components that handle low level signals, this amplifier can be
affected by its environment. Avoid placing the unit on top of other
components. Also avoid routing audio signal cables near power cords. This will
minimize the chance it will pick up hum or interference.
The unit generates heat as part of its normal operation. The heat sinks and
ventilation openings in the amplifier are designed to dissipate this heat. The
ventilation slots in the top cover must be open. There should be 10 cm (4
inches) of clearance around the chassis, and reasonable airflow through the
installation location, to prevent the amplifier from overheating.
Remember the weight of the amplifier when you select an installation location.
Make sure that the shelf or cabinet can support it. We recommend installing
the unit in furniture designed to house audio components. Such furniture is
designed to reduce or suppress vibration which can adversely affect sound
quality. Ask your authorized Rotel dealer for advice about component furniture
and proper installation of audio components.
Cables
Be sure to keep the power cords, digital signal cables and analog audio signal
cables in your installation away from each other. This will minimize the
chance of the analog audio signal cables picking up noise or interference from
the power cords or digital cables. Using only high quality, shielded cables
will also help to prevent noise or interference from degrading the sound
quality of your system. If you have any questions see your authorized Rotel
dealer for advice about the best cable to use with your system.
The RR-AX1400 Remote Control
Some functions can be done with either the front panel controls, or the
supplied RR-AX1400 remote control. When these operations are described, the
square call out numbers refer to the main unit, while the encircled letters
refer to the remote control.
Remote Control Batteries
Two AAA size batteries (supplied) must be installed before the remote control
can be used. To install the batteries, remove the cover on the back of the RR-
AX1400. Install the batteries as shown in the illustration in the battery
well. Test the control for proper operation, then replace the cover. When the
batteries become weak the remote control won’t operate the A14MKII
consistently. Installing fresh batteries should eliminate the problem.
AC Power and Control
AC Power Input
Your unit is configured at the factory for the proper AC line voltage in the
country where you purchased it (either 120 volts AC or 230 volts AC with a
line frequency of either 50 Hz or 60 Hz). The AC line configuration is noted
on a decal on the back panel.
NOTE: Should you move your amplifier to another country, it is possible to reconfigure it for use on a different line voltage. Do not attempt to perform this conversion yourself. Opening the enclosure of the unit exposes you to dangerous voltages. Consult a qualified service person or the Rotel factory service department for information.
NOTE: Some products are intended for sale in more than one country and as such are supplied with more than one AC cord. Please only use the one appropriate for your country/region.
The unit does not draw high levels of current from the power outlet. However,
it should be plugged directly into a polarized wall outlet using the supplied
cable or other compatible cable as recommended by your authorized Rotel
dealer. Do not use an extension cord. A heavy duty multi-tap power outlet
strip may be used if it (and the wall outlet) can handle the current demanded
by the amplifier and all the other components connected to it.
If you are going to be away from home for an extended period of time such as a
month-long vacation, it is a sensible precaution to unplug your amplifier (as
well as other audio and video components) while you are away.
Power Switch 1A and Power Indicator 2
Press the front panel Power Switch button 1, to turn the unit on. The Power
Indicator light 2 is illuminated when the unit is on. Press Power Switch
button again to turn the unit off.
When the power switch is in the ON position, the remote control ON and OFF buttons may be used to activate the A14MKII. In Standby mode the power LED is red, but the display is turned OFF.
12V Trigger Connection 19
See Figure 5
Some audio components can be turned on automatically when they receive a 12V
turn on signal. The two 12V Trigger Outputs of the A14MKII unit provide the
required signal. Connect compatible components to the amplifier with a
conventional 3.5mm mini plug cable. When the unit is in standby mode or turned
off, the trigger signal is interrupted, and the components controlled by it
are turned off.
Protection Indicator 2
The amplifier has both thermal and over-current protection circuitry that
protects the amplifier against damage in the event of extreme or faulty
operating conditions. The protection circuits are independent of the audio
signal and have no impact on sonic performance. Instead, the protection
circuits monitor the temperature of the output devices and shut down the
amplifier if temperatures exceed safe limits.
Most likely, you will never see this protection circuitry in action. However,
should a faulty condition arise, the amplifier will stop playing and will
display “AMP PROTECTION“ on the front panel. The power indicator 2 on the
front panel will turn red.
If this happens, turn the amplifier off. Let it cool down for several minutes,
and attempt to identify and correct the problem that caused the protection
circuitry to engage. When you turn the amplifier back on, the protection
circuit will automatically reset and the power indicator 2 should turn blue.
In most cases, the protection circuitry activates because of a fault condition
such as shorted speaker wires, or inadequate ventilation leading to an
overheating condition. In very rare cases, highly reactive or extremely low
impedance speaker loads could cause the protection circuit to engage.
If the protection circuitry triggers repeatedly and you are unable to isolate
and correct the faulty condition, contact your authorized Rotel dealer for
assistance in troubleshooting.
Input Signal Connections
NOTE: To prevent loud noises that neither you nor your speakers will appreciate, make sure the system is turned off when you make any signal connections.
Phono Input – and Ground Connection (GND) 0
See Figure 3
Plug the cable from the turntable into the appropriate left and right phono
inputs. If the turntable has a “ground” wire, connect it to the screw terminal
to the left of the Phono inputs. It will help prevent hum and noise.
Line Level Inputs =qw
See Figure 3
The CD, Tuner, and Aux inputs of the amplifier are “line level” inputs. These
are for connecting components such as CD players or other audio playback
devices with an analog audio output.
The Left and Right channels are labeled and should be connected to the corresponding channels of the source component. The Left connectors are white, the Right connectors are red. Use high quality RCA cables for connecting input source components to the unit. Ask your authorized Rotel dealer for advice about cables.
Digital Signal Inputs 24
See Figure 4
There are two sets of digital inputs labeled 1 and 2 for COAXIAL and OPTICAL
respectively. Connect the COAXIAL or OPTICAL outputs of your source component
into these sockets. The digital signals will be decoded and played by the
amplifier. The unit is capable of decoding PCM signals up to 24 bit, 192kHz.
Preamp Output 23
The amplifier has a set of preamp outputs labeled PRE OUT. The currently selected source input is available from this output. Typically the PRE OUT output is used to provide a signal to another integrated amplifier or power amplifier, which is used to drive remote speakers.
NOTE: Changes to the settings of the Volume, Balance or Tone controls affect the signal from the Preamp Output.
Speaker Outputs
See Figure 3
Speaker Selector Switch 5
The amplifier has two sets of speaker outputs, labeled “SPEAKER A” \ and
“SPEAKER B” a. The speaker outputs are controlled by the A-B speaker selector
buttons 5 on the front panel or J on the remote control.
Speaker Selection
If only one set of speakers will be used at any given time, the speakers may
have an impedance as low as 4 ohms. If there are times when both the A and B
speakers will be used, all the speakers should have an impedance of 8 ohms or
more. Speaker impedance ratings are less than precise. In practice, very few
loudspeakers will present any problems for the unit. See your authorized Rotel
dealer if you have any questions.
Speaker Wire Selection
Use insulated two-conductor stranded wire to connect the unit to the speakers.
The size and quality of the wire can have an audible effect on the performance
of the system. Standard speaker wire will work, but can result in lower output
or diminished bass response, particularly over longer distances. In general,
heavier wire will improve the sound. For best performance, you may want to
consider special high-quality speaker cables. Your authorized Rotel dealer can
help in the selection of cables for your system.
Polarity and Phasing
The polarity – the positive/negative orientation of the connections – for
every speaker and amplifier connection must be consistent so all the speakers
will be in phase. If the polarity of one connection is reversed, bass output
will be very weak and stereo imaging degraded. All wire is marked so you can
identify the two conductors. There may be ribs or a stripe on the insulation
of one conductor. The wire may have clear insulation with different color
conductors (copper and silver). There may be polarity indications printed on
the insulation. Identify the positive and negative conductors and be
consistent with every speaker and amplifier connection.
Speaker Connection
Turn off all the components in the system before connecting the speakers.
The amplifier has color-coded binding post type speaker connectors on the back
panel. These connectors accept bare wire, connector lugs, or dual banana type
connectors. (Except in European Community countries where their use is not
permitted.)
Route the wire from the amplifier to the speakers. Give yourself enough slack
so you can move the components to allow access to the speaker connectors.
If you are using dual banana plugs, connect them to the wires and then plug
into the backs of the binding posts. The thumbscrews of the binding posts
should be screwed in all the way (clockwise).
If you are using terminal lugs, connect them to the wires. If you are attaching bare wires directly to the binding posts, separate the wire conductors and strip the insulation from the end of each conductor. Be careful not to cut into the wire strands. Unscrew (turn counterclockwise) the binding post thumbscrews. Place the connector lug or wire around the binding post shaft. Turn the thumbscrews clockwise to clamp the connector lug or wire firmly in place.
NOTE: Be sure there are no loose wire strands that could touch adjacent wires or connectors.
Headphone Output
The headphone output allows you to connect headphones for private listening.
This output accepts a standard 3.5mm (1/8”) mini stereo headphone connector.
Plugging in a set of headphones does not cut off the signal to the speakers.
Use the front panel 5 or remote control J A-B speaker selector buttons to turn
off the speakers.
NOTE: Because the sensitivity of speakers and headphones can vary widely, always reduce the volume level before connecting or disconnecting headphones.
Display 6
The front panel display shows the source selected, volume level and tone settings. The display provides access to the setup and configuration menu options of the amplifier.
Front USB Input 3
The front USB input can be connected to an iPhone, iPad or iPod device
providing music playback to the amplifier. To enable audio playback using one
of these devices simply plug the device into the front USB and select USB as
the desired source. The iPhone, iPad and iPod device will remain active
allowing search and play functions.
APTX Bluetooth Connection 15
The Bluetooth Antenna e on the A14MKII’s back panel is for wireless
streaming via Bluetooth, from your device (i.e. mobile phones, tablets or
computers). From your device, look for “Rotel Bluetooth” and connect to it.
Connection is normally automatic, but if prompted for a password, please
enter “0000” on your device. The A14MKII’s supports traditional Bluetooth,
AAC and APTX Bluetooth audio streaming.
Rear USB Power Port zz
The rear USB port provides 5V/0.5A for charging or powering USB devices
including streaming music players. This port does not allow playback of audio.
The port can be configured to remain powered even when the A14MKII is in
standby mode through the front panel setup menu (See USB POWER option on page
14).
This configuration option allows the attached streaming source to remain
powered for use with the Signal Sense function for automatic power on/ off
control of the amplifier.
NOTE: When configured to provide continuous power to the rear panel USB
port the A14MKII will consume additional power even when in standby mode.
Audio Controls
Volume Control 7E
Turn the control clockwise to increase the volume, or counter clockwise to
decrease the volume. From the remote control press the volume + or – button to
turn the volume up or down. Press the MUTE F button to completely mute the
volume.
Balance Control 9B
The Balance Control adjusts the left-to-right balance of the sound output. The
factory default is the center position or “0”. To change the balance from the
front panel, press the MENU 9 button to toggle the front display to BALANCE
setting mode. Then press the – or + buttons on the front panel to change the
value to LEFT or RIGHT. The value can change from L15 to R15.
NOTE: This setting is saved permanently including after powering off the
A14MKII.
To make temporary changes not saved after power off, from the remote,
press the BAL B button to access the BALANCE SETTING menu, then press
the up/down/left/right C arrow buttons to adjust.
Tone Control Bypass 9B
Bass and Treble Control (Tone Control) circuits are bypassed at factory
default to ensure the purest possible sound. The front display will show TONE
BYPASS. To turn on the tone control from the front panel, press the MENU 9
button to toggle to the Bypass control then press the – or + buttons to turn
bypass on or off.
NOTE: This setting is saved permanently including after powering off
the A14MKII.
To temporarily changes the Tone Control Bypass, press the BYPASS B button on
the remote control to toggle the Bypass mode enabled and disabled.
Bass and Treble Controls 9B
Set the Bass or Treble controls from the front panel by pressing the MENU
9 button to the Bass and Treble Setting menu in sequence. Press the – or +
buttons to adjust the value. The Bass and Treble values range from -10 to +10.
NOTE: These settings are saved permanently including after powering off
the A14MKII.
To temporarily change the Bass and Treble settings from the remote control,
press the BASS or TREB B button, then press the up/down/left/right C arrow
buttons on the remote to adjust the value.
NOTE: Bass and Treble changes are only available when Tone Bypass is
disabled (see Tone Control Bypass section)
A properly setup high-performance audio system produces the most natural sound
with little or no adjustment of the tone controls. Use these controls
sparingly. Be particularly careful when turning the controls up. This
increases
the power output in the bass or treble range, increasing the load on the
amplifier and speakers.
NOTE: Setting the Bass and Treble controls do not automatically turn
on the tone control. To turn on tone control, refer to previous section
Tone Control Bypass.
Source Input Selector 8I
Press the corresponding input button on the front panel 8 or remote control
I to select the desired listening source.
Push the front panel source buttons to toggle between Optical 1 – 2 ,
Coaxial
1- 2 and Aux 1 – 2 or use the dedicated source button on the remote
control.
Dimmer Control
Display Dimmer 9D
To change the brightness of the front display, press the MENU 9 button to
toggle to the DIMMER Settings. Then press the – or + buttons on the front
panel to change the display brightness.
NOTE: This setting is saved permanently including after powering off the A14MKII.
To temporarily change the display brightness, press the DIM D button on the remote.
LED Dimmer 9
To change the brightness of the Power LED and the two Speaker Selector LEDs on
the front panel, press the MENU 9 button to toggle to the LED DIMMER Settings.
Then press the – or + buttons on the front panel to change the LEDs
brightness.
NOTE: This setting is saved permanently including after powering off the A14MKII.
PC-USB Input 15
See Figure 4
Connect this input using the supplied USB cable to the PC-USB socket of your
computer.
The A14MKII supports both USB Audio Class 1.0 and USB Audio Class 2.0 modes.
Windows computers do not require installation of a driver for USB Audio Class
1.0 and support playback of audio up to 96kHz sampling rates. The Factory
Default setting is USB Audio Class 1.0.
To take advantage of USB Audio Class 2.0 audio playback supporting up to
384kHz sampling rates you will need to install the Windows driver supplied on
the CD included with the A14MKII. You will also need to switch the A14MKII to
USB Audio Class 2.0 playback mode with the following:
- Press MENU on the front panel until “PC-USB CLASS” appears on the display.
- Select “2.0” using the “+” button.
- Power cycle the A14MKII and reboot your PC after changing the USB
Audio mode to ensure both units are properly configured.
Many audio playback applications do not support 384kHz sampling rate.
Please confirm your audio player supports 384kHz audio and you have 384kHz
audio files to properly playback this sample rate. Also, you may need to
configure the audio driver in your PC to output 384kHz or your computer may
“down sample” to a lower audio sample rate. For more information please refer
to your audio player or operating system information.
The A14MKII has been certified as Roon Tested and compatible with Roon
software via PC-USB.
Being Roon Tested means that Rotel and Roon have collaborated to ensure you
have the best experience using Roon software and the A14MKII together, so you
can just enjoy the music.
For the best user experience it is suggested to use USB Audio Class 2.0 when
using Roon.
NOTE: USB Audio Class 2.0 requires installation of the Windows PC driver
on the CD ROM included with the A14MKII.
NOTE: MAC computers do not require a driver to support PC-USB Audio Class
1.0 or 2.0.
NOTE: Upon successful installation of the driver, you may need to select
the ROTEL audio driver from the audio/speaker setup of your computer.
NOTE: Support for MQA and MQA Studio requires USB Audio Class 2.0. Please
select USB Audio 2.0 to support MQA.
Rotel Link 17
Rotel Link is not used for A14MKII.
EXT REM IN Jack 18
This 3.5mm mini-jack receives command codes from industry-standard infrared
receivers via hard-wired connections. This feature could prove useful when the
unit is installed in a cabinet and the front-panel sensor is blocked. Consult
your authorized Rotel dealer for information on these external repeaters and
the proper wiring of a jack to fit the mini-jack receptacle.
RS232 Connector 20
The A14MKII can be controlled via RS232 for integration with automation
systems. The RS232 input accepts a standard straight DB-9 Male-to-Female
cable.
For additional information on the connections, software, and operating codes
for RS232 control of the A14MKII, contact your authorized Rotel dealer.
Network Connection 21
The A14MKII can be attached to a network using the rear panel NETWORK socket
o. The NETWORK configurations allow both STATIC and DHCP IP addressing. See
the Network section of this manual under Setting Menu for IP address
configuration information.
The NETWORK connection allows software updates to be downloaded from the
Internet. The NETWORK connection also allows IP control for integration with
automation systems.
For additional information on the IP control please contact your authorized
Rotel dealer.
Settings Menu
You can access the SETUP menu from the front panel by pressing the MENU
9 button or the K button on the remote. You can change the value of
the selected option by pressing the – or + buttons on the front panel or the
up/down/left/right C arrow buttons on the remote. Step through the
sub-menus by pressing the MENU 9 button on the front panel or the K
button on the remote.
-
TONE BYPASS: TONE BYPASS on/off (For more information refer to Tone Control Bypass section).
NOTE: This setting is stored permanently even after the A14MKII is powered off. -
BASS: BASS level can be changed to desired settings. (For more information refer to Bass and Treble Control section.)
NOTE: This setting is stored permanently even after the A14MKII is powered off. -
TREBLE: TREBLE level can be changed to desired settings. (For more information refer to Bass and Treble Control section.)
NOTE: This setting is stored permanently even after the A14MKII is
powered off. -
BALANCE: Change left/right balance. (For more information refer to Balance Control section.)
NOTE: This settings is stored permanently even after the A14MKII is powered off. -
DIMMER: Dims the front display.
NOTE: This setting is stored permanently even after the A14MKII is powered off. -
LED DIMMER: Dims the Power LED and the LEDs above the Speaker Selector buttons on the front panel.
NOTE: This setting is stored permanently even after the A14MKII is powered off. -
POWER ON MAX VOL: This sets the maximum volume level when the unit is turned on. “45” is the factory default.
NOTE: Power On Max Volume settings do not apply to sources
configured with Fixed Gain.
-
POWER MODE: Enables the A14MKII to be controlled via the network port when attached to an automation system. The power consumption is higher in Quick Power mode. If network control is not required select the Normal Power mode. “Normal” is the factory default.
Valid settings include: Quick, Normal.
NOTE: When the POWER MODE is configured to Quick, the A14MKII will consume additional power in standby mode.
NOTE: Due to local power consumption regulations the POWER MODE function is not available in all markets. -
USB POWER: This option allows the rear panel USB connector to provide power, even when the A14MKII is in standby mode.
To enable the continuous power mode select the ALWAYS option. To provide power
only when the A14MKII is powered on, select the NORMAL option.
The default for USB POWER is set to NORMAL.
NOTE: The front panel power button must be in the ON position to supply
power to the rear panel USB connector.
NOTE: When the USB POWER is configured to ALWAYS the A14MKII will consume
additional power in standby mode to supply USB power.
NOTE: Due to local power consumption regulations the USB POWER function
is not available in all markets.
- OFF TIMER: The A14MKII can be configured to automatically power off if unused for a specified period. If no changes are made to the unit within the specified “Off Timer” period, the unit will automatically go to STANDBY mode. The auto power off timer will be restarted if changes are made to the volume, source or playback. The default for Off Timer is set to 20 MINS. Valid settings include: 20MINS (Default) DISABLE, 1 HOUR, 2 HOURS, 5 HOURS, 12 HOURS.
- SIGNAL SENSE: Check if an audio signal is present on the configured Signal Sense input. The A14MKII monitors the data stream to determine if there is audio. If there is no audio detected for 10 minutes, the A14MKII
will enter Signal Sense Power Mode. When in Signal Sense Power Mode and the A14MKII detects audio on Signal Sense input, the unit will automatically power on. To disable this function, select the OFF option
which is the factory default setting.
NOTE: When the SIGNAL SENSE function is activated the A14MKII will
consume additional power in signal sense standby mode.
NOTE: Due to local power consumption regulations the SIGNAL SENSE
function is not available in all markets.
- FIXED GAIN: Configures a Fixed Volume level for a specified input. To enable this feature, select the desired fixed volume level for AUX1, AUX2, USB, PC-USB, Optical 1, Optical 2, Coax 1, Coax 2, or Bluetooth. When enabled and the input with a Fixed Volume is selected, the Volume level will immediately be set to the specified level.
Valid settings include: VARIABLE, FIXED MIN, FIXED 01-95, FIXED MAX.
- AUX1 VOL: VARIABLE (disabled) is factory default.
- AUX2 VOL: VARIABLE (disabled) is factory default.
- USB VOL: VARIABLE (disabled) is factory default.
- PC-USB VOL: VARIABLE (disabled) is factory default.
- OPT1 VOL: VARIABLE (disabled) is factory default.
- OPT2 VOL: VARIABLE (disabled) is factory default.
- COAX1 VOL: VARIABLE (disabled) is factory default.
- COAX2 VOL: VARIABLE (disabled) is factory default.
- BTOOTH VOL: VARIABLE (disabled) is factory default.
NOTE: The Volume knob on the front panel and Volume +/- buttons on the IR remote are disabled when the volume is Fixed. To disable this feature set the Fixed Volume level to “Variable”.
- PC-USB CLASS: Change supported PC-USB Audio Class of the attached device.
NOTE: Some computers attached to the PC-USB do not support USB Audio Class 2.0 and do not support 32/384 audio playback. If needed the PC-USB can be configured for USB Audio Class 1.0. Please refer to your computer operating system for details.
- PC-USB AUDIO MODE: Change PC-USB Audio mode to support MQA and PCM Audio up to 24bits or PCM Audio Only up to 32bits. When PCM 32B is selected MQA audio is not supported. To playback MQA the MQA/24B option must be selected.
Valid settings include: MQA/24B (Default), PCM 32B.
-
VIEW NETWORK: Shows the network connection status and to view
the network settings. To view the network settings, press the + button on
the front panel or the ENT button on the remote control. If the network is properly configured and attached, “Connected” will be displayed. To view additional network configuration details, including IP Address information, press the MENU button to toggle through the settings. -
CONFIGURE NETWORK: Allows configuration of the network IP settings.
To enter the Network Configuration menu option press the + button on the front panel or the ENT button on the remote control.
NOTE: Configuration of the network requires the use of the remot control
to enter the IP address details. This setup cannot be completed using the
front panel controls. Please ensure you have access to the remote control
before proceeding with Network Configuration.
To begin configuration of the network, press the ENT button on the remote
control and follow as below:
The A14MKII supports both DHCP and STATIC IP addressing. Select the desired IP
address method with the left/right arrow buttons on the remote control and
press ENT to confirm.
If DHCP is selected, the A14MKII will refresh the IP address after pressing the ENT button on the remote control to confirm. The refresh process could take up to 10 seconds. The display will indicate if the DHCP refresh was successful. If the refresh process failed, check the network connections and try again by pressing the ENT button on the remote control. To exit the DHCP refresh process, press the MENU button.
If STATIC IP address mode is selected, you must configure all settings for the network, including IP Address, Subnet Mask, Gateway and DNS Server. Use the up/down arrow buttons on the remote control to adjust the values and press the left/right buttons on the remote control to move to the next section. When the proper IP information is configured press ENT to confirm.
NOTE: For more information regarding network connection please contact
your authorized Rotel dealer.
NOTE: A network connection is not required for the A14MKII to operate.
- S/W VERSION: This shows the current software version loaded into the A14MKII. The software can be updated if the A14MKII is properly connected to the Internet.
- Press the “+” button on the front panel to check if a new software version is available.
- If a new software version is available, press the “+” button on the
- front panel, to begin the software update process.
- The new software will be downloaded from the Internet. The A14MKII will power cycle when the software update is complete.
NOTE: Do NOT power off the A14MKII during the software update
process.
NOTE: It is recommended to Reset Factory Defaults after the software
update is complete.
- PC-USB VERSION: This shows current loaded software version for PC USB processor.
FACTORY DEFAULT: This sets the unit back to the original state as when it left the factory. Press the “+” button on the front panel or the ENT button on the remote control to enter factory reset setting. And then press the “+” button or ENT again to begin reset, or press the MENU button to cancel.
NOTE: All previously configured options will be erased and reset to the factory default settings.
Troubleshooting
Most difficulties in audio systems are the result of incorrect connections, or improper control settings. If you encounter problems, isolate the area of the difficulty, check the control settings, determine the cause of the fault and make the necessary changes. If you are unable to get sound from the unit, refer to the suggestions for the following conditions:
Power Indicator Is Not Illuminated
The Power Indicator and the basic items in the Display window should be
illuminated whenever the unit is plugged into the wall power outlet and the
Power button is pushed in. If it does not illuminate, test the power outlet
with another electrical device, such as a lamp. Be sure the power outlet being
used is not controlled by a switch that has been turned off.
Fuse Replacement
If another electrical device works when plugged into the power outlet, but the
Power Indicator still will not illuminate when the unit is plugged into the
wall outlet, it indicates that the internal power fuse may have blown.
If you believe this has happened, contact your authorized Rotel dealer to get
the fuse replaced.
No Sound
Check the signal source to see if it is functioning properly. Make sure the
cables from the signal source to the amplifier inputs are connected properly.
Be sure the Input Source is set to the proper input. Check the wiring between
the amplifier and the speakers.
Cannot Connect via Bluetooth
If you cannot pair your Bluetooth enabled device to the A14MKII, delete the
memory of the previous connection on your device. On your device this is often
listed as “Forget this Device”. Then try to make the connection again.
Playable Audio Formats
USB Apple (iPhone, iPod, iPad)
Format | Notes |
---|
Any supported file loaded to Apple device.
| Any supported file loaded to Apple device. Phone may resample depending on stored format. May exclude Apps designed to play formats not originally supported by the sending device.
APTX and AAC Bluetooth
Format | Notes |
---|---|
Any format supported by the sending device. | May exclude Apps designed to play |
formats not originally supported by the sending device.
PC-USB
Format | Notes |
---|---|
Any supported format by the PC software | |
Format determined | PCM Audio: |
by the Media Player/ | 44.1k, 48k, 88.2k, 96k, 176.4k, 192k, 384k |
Server software that | (16 bit, 24 bit and 32 bit) |
you use. | MQA, MQA Studio (24 bit / 384k) |
Roon Tested
Coax/Optical
Format | Notes |
---|
SPDIF LPCM
| 44.1k, 48k, 88.2k, 96k, 176.4k, 192k
16 bit, 24 bit
Specifications
-
Maximum Power Output 150 watts/ch, 4 ohms
-
Continuous Power Output 80 watts/ch, 8 ohms
-
TotalHarmonicDistortion < 0.018%
-
Intermodulation Distortion (60 Hz : 7k Hz, 4:1) < 0.03%
-
Frequency Response
-
Phono Input 20 Hz – 20k Hz, ± 0.5 dB
-
Line Level Inputs 10 Hz – 100k Hz, ± 0.5 dB
-
Damping Factor (20 – 20,000 Hz, 8 ohms 220
-
Input Sensitivity / Impedance
-
Phono Input 3.4 mV / 47k Ohms
-
Line Level Inputs 230 mV / 24k Ohm
-
Input Overload
-
Phone Input 50 mV
-
Line Level Inputs 4 V
-
Preamp Output / Impedance 1.2 V / 470 Ohms
-
Tone Controls – Bass / Treble ± 10 dB at 100 Hz / 10k Hz
-
Signal to Noise Ratio (A weighting)
-
Phono Input 90 dB
-
Line Level Inputs 100 dB
-
Digital Section
-
Frequency Response 10Hz – 90k Hz (± 2dB,MAX)
-
Signal to Noise Ratio (A weighting) 103 dB
-
Input Sensitivity/Impedance 0 dBfs/75 ohms
-
Preamplifier Output Level 1.4 V (at – 20dB)
-
Digital Inputs SPDIF LPCM (up to 192k Hz 24 bit)
-
PC-USB
- (up to 192k Hz 24 bit)
- PC-USB USB Audio Class 1.0
- (up to 96kHz 24bit)
- USB Audio Class 2.0
- (up to 384kHz 32bit)*
- *Driver installation required
- MQA and MQA Studio
- (up to 384kHz 24bit)
- Roon Tested
-
General
Power Requirements -
USA 120V, 60 Hz
-
EC 230V, 50 Hz
-
Standby Power Consumption
-
Normal < 0.5 watts
-
Network wakeup < 2 watts
-
Power Consumption 280 Watts
-
BTU (4 ohms, 1/8th power) 632 BTU/h
-
Dimensions (W, H, D) 430 x 93 x 345 mm
-
17” x 3 5/8” x 13 1/2”
-
Panel Height 80 mm / 3 1/8”.
-
Weight (net) 8.94 kg, 19.7 lbs.
All specifications are accurate at the time of printing. Rotel reserves the
right to make improvements without notice.
Rotel and the Rotel HiFi logo are registered trademarks of The Rotel Co., Ltd.
Tokyo, Japan.
The Rotel Co. Ltd.
Tachikawa Bldg. 1F.,
2-11-4, Nakane, Meguro-ku,
Tokyo, 152-0031
Japan
Rotel USA
Sumiko
11763 95th Avenue North
Maple Grove, MN 55369
USA
Phone: 510-843-4500 (option 2)
E-mail: Rotelsupport@sumikoaudio.net
Rotel Canada
Kevro International
902 McKay Rd. Suite 4
Pickering, ON L1W 3X8
Canada
Tel: +1 905-428-2800
Rotel Europe
Dale Road
Worthing, West Sussex BN11 2BH
England
Phone: + 44 (0)1903 221 710
Fax: +44 (0)1903 221 525
“Made for iPod,” and “Made for iPhone,” means that an electronic accessory has
been designed to connect specifically to iPod or iPhone, respectively, and has
been certified by the developer to meet Apple performance standards. Apple is
not responsible for the operation of this device or its compliance with safety
and regulatory standards. Please note that the use of this accessory with
iPod, or iPhone may affect wireless performance.
iPhone, iPod, iPod classic, iPod nano, and iPod touch are trademarks of
Apple Inc., registered in the U.S. and other countries.