THERMASOL PROIII Series Ultimate Steam Generator Owner’s Manual
- June 6, 2024
- THERMASOL
Table of Contents
- Important Information Before You Install
- Tools and Materials
- Sizing or Double Checking the Unit Specified
- Electrical Wiring
- Placing the Generator
- Water Supply and Drain Pan
- Control Cable
- Steam Line and Steamhead
- Steamhead Location
- Final Pre-Check Before Operation
- Notes:
- ThermaSol Product Registration
- GENERATOR WARRANTY
- GENERATORS
- “IN-HOME” LIMITED WARRANTY
- LIFETIME – FACTORY LIMITED
- EXCLUSIONS
- LIMITATIONS
- GENERATOR WARRANTY REGISTRATION CARD
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
OVER 60 YEARS OF STEAM SHOWER INNOVATION
PROIII Series Generator
Installation Operation Manual
thermasol.com/solutions
PROIII-84, PROIII-140, PROIII-240, PROIII-395
PROIII-575, PROIII-750, PROIII-1200
Important Information Before You Install
Make sure the walls, ceiling, and floor materials are suitable for use with
steam. If using acrylic walls, they must be steam rated by their manufacturer.
ThermaSol only recommends specific generators for acrylic modules. Ensure
electrical power is turned off for the duration of the installation.
PLEASE REVIEW THE WARNINGS BELOW AND LEAVE THIS MANUAL WITH THE HOMEOWNER
DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED WITH YOUR DOCTOR AND
RECEIVED WRITTEN PERMISSION TO DO SO. USE OF THIS PRODUCT MAY BE HAZARDOUS TO
YOUR HEALTH.
PLEASE CONSULT YOUR PHYSICIAN BEFORE USING. IF YOU ARE PREGNANT, ELDERLY, HAVE
HIGH BLOOD PRESSURE, DIABETES, SUFFER FROM
HEART DISEASE, AND INTOXICATED, OR NOT IN GOOD HEALTH, DO NOT USE THIS STEAM
BATH.
STEAM IS HOT! DO NOT TOUCH OR GO NEAR THE STEMHEAD FROM THE TIME THE UNIT IS
“ON”, UP TO ONE HOUR AFTER IT HAS SHUT OFF.
SEVERE BURNS WILL OCCUR IF YOU COME IN CONTACT WITH THE STEAM HEAD OR STEAM
EMITTING FROM THE STEAM HEAD.
NEVER ATTEMPT TO FILL AROMA RESERVOIR ON THE STEAM HEAD WHEN THE UNIT IS IN
THE ON POSITION. SEVERE BURNS WILL OCCUR.
DO NOT USE THERMAL AROMATHERAPY OILS OR SKINCARE PRODUCTS OR ANY PRODUCT
ASSOCIATED WITH YOUR THERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR
DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.
DO NOT USE STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS, AS THIS
CAN BE HAZARDOUS TO YOUR HEALTH.
YOUR SHOWER MAY BE A SLIP-AND-FALL HAZARD. CHECK WITH YOUR CONTRACTOR OR
FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM
APPLICATION. SLIPPING AND FALLING INTO THE STEAM HEAD ITSELF OR INTO THE
STREAM EMITTING FROM THE STEAM HEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL
INJURY.
IF YOU ARE FEELING UNCOMFORTABLE, DIZZY, FAINT, OR STARTING TO FALL ASLEEP
IMMEDIATELY EXIT THE STEAM ROOM.
DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN
ADULT.
THERMASOL STEAM BATH GENERATORS ARE NOT DESIGNED TO BE USED FOR SPACE HEATING
PURPOSES.
THERMASOL STEAM BATH GENERATORS ARE FOR INDOOR USE ONLY. THEY SHOULD NEVER BE
LOCATED OUTSIDE THE HOME.
Tools and Materials
Materials needed:
-
Brass ball valve 3/8″ NPT or a brass shut-off valve (for water supply shut-off)
Pipe compound -
Copper or brass fittings & nipples (sizes and quantities per instructions)
-
Wire (see page 3)
-
Copper tube or pipe
-
Wire cap nuts
-
Flex conduit (for units 11kW and above)
-
Brass or copper tee connection and plug
-
Silicone
-
Other materials as required
Materials recommended:
- In-line water filter (recommended)
- PRO III-750 and PRO III-1200: (2) 1/2″ – 3/4” drop elbow/adapters Tools needed:
- Pipe wrench
- Tubing cutter
- Wire cutters or wire strippers
- Adjustable wrench
- Screwdriver (Phillips and regular)
- Solder and flux
- 1-1/16″ inch masonry drill bit
- 1-1/8″ inch hole saw for ThermaSol SteamVection steam head rough-in
- Drill motor
- Propane torch
- Other tools as required
Sizing or Double Checking the Unit Specified
If you are installing the unit or thinking of adding one to your next project,
you will need to make sure the unit is sized properly.
Calculate the shower area
(Length x Width x Height = Cubic Feet)
The set of numbers in the generator model number represents the maximum
capacity.
Example: Generator model PROIII-240 will be sufficient up to 240 cubic
feet (with a ceiling not exceeding 8 feet in height). Up-size 1 Unit size
for every foot over 8 feet to a maximum of 10 feet.
The model number can be found on the box or generator.
ThermaSol’s generators can be placed up to 50 feet from the shower; in an
attic, closet or below a sink are ideal locations.
Make sure the walls, ceiling, and floor materials are suitable for use with
steam.
Electrical Wiring
The size of the shower will determine the size of the generator. The size of the generator will determine electrical requirements.
- All the electrical wiring must be done per National/Local Electrical Codes.
- Run 240V Power source to the generator.
- Use copper wire only.
- Wire sizes are recommended by NEC (2002 Version). Minimum wire temperature rating 90°C. Type THHN.
- Each generator should be wired to their own separate breaker
- Turn off all electricity to the working area at the main breaker panel!
- Leave power OFF during the installation process.
MODEL| INPUT VOLTAGE| KW RATING| AMPS| PHASE|
ELECTRICAL| MAX. ROOM SIZE
---|---|---|---|---|---|---
PROIII-84| 208-240VAC| 6.0| 28| 1| NEMA 6-30P| 84 CU.FT.
PROIII-140| 208-240VAC| 8.0| 37| 1| NEMA 6-50P| 140 CU.FT.
PROIII-240| 208-240VAC| 10| 46| 1| NEMA 6-50P| 240 CU.FT.
PROIII-395| 208-240VAC| 11| 48| 1| Hardwire| 395 CU.FT.
PROIII-575| 208-240VAC| 15| 69| 1| Hardwire| 575 CU.FT.
PROIII-750| 208-240VAC| 20| 92| 1| Hardwire| 750 CU.FT.
PROIII-1200| 208-240VAC| 24| 110| 1| Hardwire| 1200 CU.FT.
ThermaSol requires that a licensed electrician perform all electrical work.
Read warnings on page 2. For illustrative purposes only. Consult with
qualified professionals for steam room construction details.
THERMASOL.COM I 800.776.0711
Placing the Generator
Select a location as near as practical to the steam shower.
Typical locations include closet, vanity cabinet, climate-controlled attic, or
basement.
Be sure to install the unit in a location that offers easy accessibility
for servicing the generator. (Power Flush maintenance is recommended every
1000 minutes of use.)
DO NOT install generator inside the steam room.
DO NOT install generator or plumbing lines in the unheated attic or any
locations where water could freeze.
DO NOT install generator outdoors or wherever environmental conditions
may affect the safety and/or performance of the generator.
The generator may be installed up to 50 feet away from the steam shower and
must be in a dry, non-combustible, well-ventilated space with 6″ clearance
around the generator.
When constructing the ceiling add a slope of 1″/foot. The control cable
provided with the generator is 50 feet in length (Item 03-6152-050).
When locating the control unit, place it as far as possible away from the
steam head and as close as is practical to where the user will be sitting.
The generator must be upright, accessible and on a level surface with all
connections on top. Access panel must be unobstructed and allow for easy
access.
Read warnings on page 2. For illustrative purposes only. Consult with
qualified professionals for steam room construction details.
THERMASOL.COM I 800.776.0711
Water Supply and Drain Pan
Use copper or brass fittings only!
DO NOT use galvanized fittings.
DO NOT use PEX or PVC tubing.
DO NOT plumb the pressure relief valve into the steam line.
Plumbing the pressure relief valve into the steam line can be hazardous,
should the steam outlet be capped off or obstructed.
Recommend installing unions on all rigid pipelines for ease of removal and
serviceability (if required).
A Use 3/8″ NPT line to connect to supplied 3/8″ braided hose.
B The drain pan is required for installation.
C Plumb the 3/4″ drain connection on the pan to an approved drain.
Drain Pan must be installed on all generator installations.
All plumbing shall be performed by a qualified licensed plumber and in
accordance with applicable national and local codes.
Once you select the generator location, you will need to run water to the
unit.
Connect a tee to the existing cold water line.
D Install copper pipe from the tee to create an inlet line for a unit.
E Install a brass shut-off valve on the water inlet line in an accessible
area in front of the brass union (and recommended in-line water filter). A
stainless steel water supply flex connector may be used.
F Pre-Installed water line debris screen (included) in the water inlet on
the generator.
Before making the water connection, flush the water line into a five-gallon
pail to remove any silt or other materials that may be in the water inlet
line.
Make a final connection but DO NOT turn the water or power on
yet.
Control Cable
NOTE: It is recommended to run the cable through an electrical conduit.
Route the data cable (included with generator) through the finished wall to
the back side of the control.
The other end of the cable runs to the steam generator location or if present
the PDM.
Connect the data cable to the steam generator connector.
DO NOT pinch, nail, staple, wedge, or bind the data cable.
DO NOT wrap the data cable around the steam line or route it in a manner
so that the hot steam line could melt the cable.
Any damage to the control cable will result in the control not working
properly.
Carefully connect the data cable to the generator and control BEFORE turning
the power on to the generator.
Connect the data cable to the steam generator connector.
(The other end of the cable runs to the back of the control in the shower
location or to the PDM if present.
Steam Line and Steamhead
Now you will need to decide on the steam head placement in the shower so you can run the steam line from the generator to the steam head. There are a couple of things you need to know about the placement of the steam head and steam line itself.
DO NOT install any valve in the steam line. The flow of steam must be
unobstructed.
DO NOT plumb any traps in the steam line.
A. The steam outlet on the generator requires a 1/2″ brass union for easy
installation (included).
B. Use 1/2″ brass pipe or copper tubing from unit to steam head rough-in
fitting as permitted by codes.
For PROIII-750 through PROIII-1200 Models, use 3/4″ brass pipe or copper
tubing for the steam line.
The steam line can run up and then down, once; or horizontal; but never run
down and then up. If it does, a steam trap will be produced at the low point
blocking the flow of steam.
Insulate the steam outlet piping if the piping run exceeds 10 feet or is
exposed to cold areas. Use steam-rated insulation.
Pitch/angle steam lines back towards generator before any up or downturns;
pitch/angle towards steam room after any up or down and avoid perfectly level
plumbed lines. This prevents condensation from pooling at low points in the
streamline.
Read warnings on page 2. For illustrative purposes only. Consult with
qualified professionals for steam room construction details.
THERMASOL.COM I 800.776.0711
Steamhead Location
DO NOT install the steam head near the seating area or the user.
DO NOT forget to install the steam head rough-in fitting!
C. Install the steam head 24″ from the floor or bathtub rim and 6″ from any
corner.
Steamhead is to be mounted as far as possible from the typical bathing
position (seated or standing) and installed as far from the in-shower
controller as possible.
For retrofit to existing finish wall:
Drill a 1-1/8″ diameter hole in the shower wall or wall above the bathtub rim
for the steam outlet rough-in fitting and install to be flush with the
finished wall. this housing must be sealed to the wall to not allow vapor or
water behind it. (plumbing must be done from backside of finished space)
For new framing: Mount and install rough-in fitting to be flush with the
finished wall.
Connect a 1/2″ NPT brass pipe or copper tubing to the steam outlet union (not
included) on the generator running the pipe to the steam head location in the
wall to connect with the steam head rough-in fitting.
It is very important that the pipe is firmly secured to the wall so that when
the steam is installed it doesn’t push the rough-in fitting back into the
wall. Install a 1/2” drop ear elbow on the end of the 1/2” pipe or tubing for
the rough-in fitting.
Use the installation tool to tighten the housing in place with a 1″ socket and
driver. Then insert the protective cap into the housing.
For all the connections, use solder for copper joints and Teflon tape for pipe
fittings and do not overtighten fittings.
DO NOT USE PVC CEMENT.
D. Once the shower wall is complete and the housing is sealed to the
wall, remove the protective cap and insert the steam head into the housing.
Use the supplied silicone to adhere the steam head to the wall sealing out any
water from getting behind the head.
Use supplied o-ring lubricant to assist in steam head installation. A very
small amount is all that is needed directly on the o-rings.
thermasol.com /customer-support
Final Pre-Check Before Operation
Turn ON the water supply to the generator. Check all the connections for
leaks.
Plugin generator (unless hardwired model).
Turn ON the power source or breaker.
Verify control panel lights up and test operation. Note: Initial power-on
phase takes several minutes for the generator to heat up steam.
Please direct the homeowner to visit
www.thermasol.com/solution and click on
the “I’m the homeowner” button to learn about set-up and programing (in order
to set up the clock and any other options if applicable).
Registration information on page 12.
Notes:
ThermaSol Product Registration
Dear ThermaSol End User:
Please register your product at
www.thermasol.com/warranty so we can
assist you much quicker if you ever need to contact our Technical Support
Department.
In addition, we’ll keep you informed about your product and from time to time
we’ll update you about new products and other company announcements.
Thank you from all of us at ThermaSol and we wish you many relaxing and steamy
days ahead.
We will not sell, rent or share your personal information.
You may also fill out the form on the backside of this page and mail it to:
GENERATOR WARRANTY
All warranties provided by ThermaSol after September 1, 2014, shall extend
only to the original retail purchaser or end-user of the product and are
contingent on the proper use of the product in accordance with the
instructions and specifications published by ThermaSol and shall not apply to
any product that has been repaired or modified by persons other than approved
by ThermaSol. Proof of purchase from an Authorized Reseller will be required
to start any warranty process except where prohibited by law. These warranties
are not valid for any product that is sold with defaced or altered serial
number, or for any product that was purchased used, refurbished, “as is”, or
in unknown condition.
All warranty claims must go through ThermaSol directly.
GENERATORS
PROI, PROII, or PROIII Series Generators manufactured from April 1, 2021 – current No warranty of any kind, expressed or implied is provided for PROI, PROII, or ROIII Series Generators installed or used in any non-residential setting.
“IN-HOME” LIMITED WARRANTY
ThermaSol extends to the original purchaser a 2-year limited “In-Home” warranty to repair or replace (at its discretion) PROI,II, or III Series generators parts found to have manufacturing defects and to provide the necessary labor. After the “In-Home” Limited Warranty expires, the Lifetime – Factory Limited Warranty applies.
LIFETIME – FACTORY LIMITED
Warranty ThermaSol will replace any defective parts for the life of the product and will cover the labor at the factory. The customer is responsible for the removal/installation and shipping and handling to and from our factory in Round Rock, TX. ThermaSol guarantees all parts to be free from manufacturing defects in material and workmanship under normal use when installed in a residence only.
EXCLUSIONS
These warranties will be terminated by ThermaSol for the following reasons:
- Improper installation, such as installation that fails to observe National/Local Plumbing and/or electrical codes.
- Use of a residential unit in a non-residential or commercial application, including a hotel.
- Service to equipment by unauthorized personnel.
- Installation that does not permit proper access for service.
- Non-payment of repairs not covered under warranty.
- Modification to any part of the unit.
- Use of non-ThermaSol repair parts.
- Alteration or removal of product serial number.
- ThermaSol does not guarantee that a local service person will be available for in-home services. Unit may have to be removed and reinstalled at owner’s expense. It is the responsibility of the buyer to file a claim with the carrier/carriers for any product that has shipping damage to or from ThermaSol. An EVA (Evaluation Number) must be obtained from the factory and used on any correspondence or packages sent to the factory.
- THESE WARRANTIES ARE NON-TRANSFERABLE TO ANY OTHER PURCHASER OR PARTY OTHER THAN THE ORIGINAL PURCHASER FROM AN AUTHORIZED DEALER. THESE WARRANTIES ARE NOT VALID FOR ANY PRODUCTS SOLD USED, REFURBISHED, “AS IS”, OR IN UNKNOWN CONDITION. NO OTHER AGENT OR PARTY CAN GIVE ANY OTHER WARRANTY OR PROMISE. THESE ARE THE SOLE WARRANTIES FOR YOUR THERMASOL PRODUCT, EXCEPT AS PROVIDED BY LAW.
LIMITATIONS
- ThermaSol will not be liable in any way for any indirect, special, incidental, exemplary, or consequential damages resulting from the sale, delivery, installation or use of its products. Users are responsible for the suitability of the products for their applications. Damage resulting from improper specification or application or other operating conditions beyond ThermaSol’s control is not under warranty.
- ThermaSol will not exercise reasonable efforts in rendering service under these warranties, but shall not be liable for any damage arising out of delays; these warranties only cover the repair and/or replacement of ThermaSol product as specified by the warranty.
- ThermaSol does not guarantee that a local service person will be available for in-home services. The unit may have to be removed and reinstalled at the owner’s expense. It is the responsibility of the buyer to file a claim with the carrier/carriers for any product that has shipping damage to or from ThermaSol. An EVA (Evaluation Number) must be obtained from the factory and used on any correspondence or packages sent to the factory.
- THESE WARRANTIES ARE NON-TRANSFERABLE TO ANY OTHER PURCHASER OR PARTY OTHER THAN THE ORIGINAL PURCHASER FROM AN AUTHORIZED DEALER. THESE WARRANTIES ARE NOT VALID FOR ANY PRODUCTS SOLD USED, REFURBISHED, “AS IS”, OR IN UNKNOWN CONDITION. NO OTHER AGENT OR PARTY CAN GIVE ANY OTHER WARRANTY OR PROMISE. THESE ARE THE SOLE WARRANTIES FOR YOUR THERMASOL PRODUCT, EXCEPT AS PROVIDED BY LAW.
These warranties give you specific legal rights and you may also have other rights, which may vary, from state to state. Determination of rights under these warranties is in accordance with the laws of Texas. Any dispute under these warranties must be submitted and resolved by arbitration in Texas.
GENERATOR WARRANTY REGISTRATION CARD
HOMEOWNER’S NAME: PHONE: (__ )__
ADDRESS: CITY:
STATE: ZIP:____
EMAIL:____
SERIAL NO. DATE CODE: MODEL NO:
DATE OF PURCHASE:____
DEALER/OUTLET:__
INSTALLER NAME:__
INSTALLER PHONE: ( )____
INSTALLER ADDRESS: CITY:__
STATE: ZIP:__
SIGNATURE:____
DATE INSTALLED:___
Steam & Showering Systems
1958 STEAM WAY ROUND ROCK, TX 78665
PHONE: 800.776.0711 | FAX: 800.556.5257 |
WWW.THERMASOL.COM