Important Information before You Install
The ThermaTouch Control must be installed inside the shower. The ThermaTouch
control will only function on the current TFX, SSA and PRO Series generators.
The control should be installed 60″ from the floor of the shower and away from
the steamhead.
The steamhead should be installed 24″ from the floor and 6″ from any wall.
Locate as far as possible from the bathing seating area or location of the
users and not below any fixtures.
IMPORTANT: When locating and installing the ThermaTouch, it is required
to not place the control under any water-outlets, shower heads or in the
direct path of flowing water.
SEE DIAGRAM FOR LOCATION EXAMPLE.
PLEASE REVIEW WARNINGS BELOW AND LEAVE THIS MANUAL WITH HOMEOWNER
DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED WITH YOUR DOCTOR AND
RECEIVED WRITTEN PERMISSION TO DO SO.
USE OF THIS PRODUCT MAY BE HAZARDOUS TO YOUR HEALTH.
PLEASE CONSULT YOUR PHYSICIAN BEFORE USING. IF YOU ARE PREGNANT, ELDERLY, HAVE
HIGH BLOOD PRESSURE, DIABETES, SUFFERING FROM HEART DISEASE, ARE INTOXICATED,
OR NOT IN GOOD HEALTH, DO NOT USE THIS STEAM BATH.
STEAM IS HOT! DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE TIME THE UNIT IS
“ON,” UP TO ONE HOUR AFTER IT HAS SHUT OFF. SEVERE BURNS WILL OCCUR IF YOU
COME IN CONTACT WITH THE STEAMHEAD OR STEAM EMITTING FROM THE STEAMHEAD.
NEVER ATTEMPT TO FILL AROMA RESERVOIR ON THE STEAMHEAD WHEN UNIT IS IN THE
“ON” POSITION. SEVERE BURNS WILL OCCUR.
DO NOT USE THERMASOL AROMATHERAPY OILS, SKIN CARE PRODUCTS OR ANY PRODUCT
ASSOCIATED WITH YOUR THERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR
DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.
DO NOT USE STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS, AS THIS
CAN BE HAZARDOUS TO YOUR HEALTH.
YOUR SHOWER MAY BE A SLIP-AND-FALL HAZARD. CHECK WITH YOUR CONTRACTOR OR
FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM
APPLICATION. SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM
OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL
INJURY.
IF YOU ARE FEELING UNCOMFORTABLE, DIZZY, FAINT, OR STARTING TO FALL ASLEEP,
IMMEDIATELY EXIT THE STEAM ROOM.
DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN
ADULT.
THERMASOL STEAM BATH GENERATORS ARE NOT DESIGNED TO BE USED FOR SPACE HEATING
PURPOSES.
THERMASOL STEAM BATH GENERATORS ARE FOR INDOOR USE ONLY. THEY SHOULD NEVER BE
LOCATED OUTSIDE THE HOME.
All products must be installed in accordance with installation instructions
provided. Failure to do so may invalidate warranty at manufacturer’s
discretion. ©2019 ThermaSol.
1a Important Installation step – continued
YOUR THERMATOUCH SMART TOUCHSCREEN CONTROL COMES WITH A PREINSTALLED EARTH
GROUNDING WIRE ON THE BACK OF THE CONTROLLER. PRIOR TO INSTALLTION OF YOUR
THERMATOUCH LOCATE THE CLOSEST EARTH GROUND (COPPER WATER PIPE) AND ATTACHED
THE WIRE AS SHOWN BELOW.
IF YOU HAVE ANY QUESITONS ABOUT THIS PROCESS PLEASE CONTACT US AT
SUPPORT@THERMASOL.COM OR BY PHONE AT
800.776.0711
Tools and Materials
Materials needed:
– ThermaTouch control
– M12 cable
– Silicone
– Power Distribution Module (PDM)
– Mud Ring
– Ethernet Cable with RJ-45 Connector (not supplied)
– Other materials as required
Back of Control
REMINDER
in order to receive software updates the unit must be plugged into the
internet using an Ethernet Cable connected to a Router (Router and Ethernet
Cable not supplied).
Mud Ring Application
Control Installation and Data Cable Connection
Route the M12 cable through the finished wall to the back side of the control.
(The other end of the cable runs to the PDM location.)
NOTE: It is recommended to run the cable through electrical conduit. DO
NOT STAPLE the cable!
Run the M12 cable so the 90-degree end connection will connect to the
ThermaTouch control. Then connect the M12 Cable to
ThermaTouch control. Do not over tighten.
If the Serenity Light, Sound, Rain Head option is not used then amplified
speakers are required for sound.
- Do not staple, strain or damage data cable
- Align pins to receptacle visually before tightening
- Do not force plug
- Hand tighten only
DO NOT pinch, nail, staple, wedge, or bind the data cable.
DO NOT wrap the data cable around steam line or route it in a manner so that
the hot steam line could melt the cable.
Any damage to the control cable will result in the control not working
properly.
Carefully connect the data cable to the PDM and control BEFORE turning power
on to the generator or PDM.
Connect the data cable to Power Distribution Module (PDM).
(The other end of the cable runs to the back of the control in the shower
location.)
Sealing Control
THESE STEPS MUST BE TAKEN FOR CORRECT INSTALLATION OF THE CONTROL. REMOVE MUD
RING FROM WALL CUTOUT BEFORE MAKING FINAL CABLE CONNECTIONS TO THE THERMATOUCH
CONTROL.
TEST THAT ALL CONNECTIONS ARE WORKING BEFORE SEALING THE CONTROL TO THE WALL.
(Power on the control and see that it lights up).
A Coat the entire groove on the control back with supplied waterproof silicone
to fully seal the control to the wall.
Completely seal the control to the wall so moisture does not collect behind
it.
Place the control on the wall pressing firmly.
(You may need to tape the control into place until the silicone dries.)
Be careful not to harm the wall or control with the tape. Let dry for 24 hours
before using steam bath.
6a Connecting ThermaTouch to Generator
6b Connecting ThermaTouch to Serenity Light, Sound, Rainhead
6c Connecting ThermaTouch to Digital Shower
6b Connecting Total Wellness Package
Steam Line and Steamhead
Now you will need to decide on the steamhead placement in the shower so you can run the steam line from the generator to the steamhead. There are a couple of things you need to know about the placement of the steamhead and steam line itself.
DO NOT install any valve in the steam line. Flow of steam must be
unobstructed.
DO NOT plumb any traps in the steam line.
A The steam outlet on the generator requires a 1/2″ brass union for easy
installation (not included).
B Use 1/2” brass pipe or copper tubing from unit to steamhead rough-in fitting
as permitted by code.
The steam line can run up and then down, once; or horizontal; but never run
down and then up. If it does, a steam trap will be produced at the low point
blocking the flow of steam.
Insulate the steam outlet piping if the piping run exceeds 10 feet or is
exposed to cold areas. Use steam rated insulation.
Pitch/angle steam lines back towards generator before any up or down turns;
pitch/angle towards steam room after any up or down and avoid perfectly level
plumbed lines.
Steamhead Location
DO NOT install the steamhead near the seating area or the user.
DO NOT forget to install the steamhead rough-in fitting!
C Install the steamhead 24″ from the floor or bathtub rim and 6″ from any
corner.
Steamhead is to be mounted as far as possible from typical bathing position
(seated or standing) and installed as far from the in-shower controller as
possible.
For retrofit to existing finish wall: Drill a 1-1/8″ diameter hole in the
shower wall or wall above bathtub rim for the steam outlet rough-in fitting
and install to be flush with the finished wall. this housing must be sealed to
the wall to not allow vapor or water behind it.
(plumbing must be done from backside of finshed space)
For new framing: Mount and install rough-in fitting to be flush with finished
wall.
Connect a 1/2″ NPT brass pipe or copper tubing to the steam outlet union (not
included) on the generator running the pipe to the steam head location in the
wall to connect with the steamhead rough-in fitting. It is very important that
the pipe is firmly secured to the wall, so that when the steamhead is
installed it doesn’t push the rough-in fitting back into the wall. Install a
1/2” dropear elbow on the end of the 1/2” pipe or tubing for the rough-in
fitting.
Use the installation tool to tighten the housing in place with a 1″ socket and
driver. Then insert the protective cap into the housing.
For all the connections, use solder for copper joints and Teflon tape for pipe
fittings and do not over tighten fittings.
DO NOT USE PVC CEMENT.
D Once the shower wall is complete and the housing is sealed to the wall,
remove the protective cap and insert the steamhead into housing. Use the
supplied silicone to adherethe steamhead to the wall sealing out any water
from getting behind the head.
Use supplied o-ring lubricant to assist in steam head installation. A very
small amount is all that is need directly on the o-rings.
Upon final installation mount steamhead with facing up to allow aromatherapy
well to dispense steam.
For detailed installation instructions of the steamhead please see
Installation section in thermasol.com/customer-support
Final Pre-Check Before Operation
Turn ON the water supply to the generator. Check all the connections for
leaks.
Plug in generator (unless hardwired model).
Turn ON the power source or breaker.
Verify control panel lights up and test operation. Note: Initial power-on
phase takes several minutes for generator to heat up steam.
Please direct the home owner to visit
www.thermasol.com/solution and click on
the “I’m the home owner” button to learn about set-up and programing (in order
to set up the clock and any other options if applicable).
Trouble Shooting, Tutorials and Error Codes
Visit www.thermasol.com/solutions. Click on Troubleshoot then click on ThermaTouch Control Error Codes.
1958 STEAM WAY ROUND ROCK, TX 78665
PHONE: 800.776.0711 | FAX: 800.556.5257 |
WWW.THERMASOL.COMRead warnings on page 2. For
illustrative purposes only. Consult with qualified professional for steam room
construction details.
THERMASOL.COM I 800.776.0711
References
- Luxury Smart Steam Showers - ThermaSol Digital Showers
- Customer Support | Warranty & FAQ | ThermaSol Steam Bath
- Luxury Smart Steam Showers - ThermaSol Digital Showers