THERMASOL TT7-SVSQ Therma Touch 7 Control Instruction Manual

June 10, 2024
THERMASOL

THERMASOL logo ThermaTouch Control
TT7X-XX
Installation ManualTHERMASOL TT7-SVSQ Therma Touch 7 Control
-

For Tutorials and Troubleshooting visit www.thermasol.com/solutions

Important Information before You Install

The ThermaTouch Control must be installed inside the shower. The ThermaTouch control will only function on the current TFX, SSA and PRO Series generators.
The control should be installed 60″ from the floor of the shower and away from the steamhead.
The steamhead should be installed 24″ from the floor and 6″ from any wall. Locate as far as possible from the bathing seating area or location of the users and not below any fixtures.
IMPORTANT: When locating and installing the ThermaTouch, it is required to not place the control under any water-outlets, shower heads or in the direct path of flowing water.
SEE DIAGRAM FOR LOCATION EXAMPLE.THERMASOL TT7-SVSQ Therma Touch 7
Control - before You Install

PLEASE REVIEW WARNINGS BELOW AND LEAVE THIS MANUAL WITH HOMEOWNER
DO NOT USE THIS PRODUCT UNLESS YOU HAVE CONSULTED WITH YOUR DOCTOR AND RECEIVED WRITTEN PERMISSION TO DO SO.
USE OF THIS PRODUCT MAY BE HAZARDOUS TO YOUR HEALTH.
PLEASE CONSULT YOUR PHYSICIAN BEFORE USING. IF YOU ARE PREGNANT, ELDERLY, HAVE HIGH BLOOD PRESSURE, DIABETES, SUFFERING FROM HEART DISEASE, ARE INTOXICATED, OR NOT IN GOOD HEALTH, DO NOT USE THIS STEAM BATH.
STEAM IS HOT! DO NOT TOUCH OR GO NEAR THE STEAMHEAD FROM THE TIME THE UNIT IS “ON,” UP TO ONE HOUR AFTER IT HAS SHUT OFF. SEVERE BURNS WILL OCCUR IF YOU COME IN CONTACT WITH THE STEAMHEAD OR STEAM EMITTING FROM THE STEAMHEAD.
NEVER ATTEMPT TO FILL AROMA RESERVOIR ON THE STEAMHEAD WHEN UNIT IS IN THE “ON” POSITION. SEVERE BURNS WILL OCCUR.
DO NOT USE THERMASOL AROMATHERAPY OILS, SKIN CARE PRODUCTS OR ANY PRODUCT ASSOCIATED WITH YOUR THERMASOL UNIT WITHOUT CONSULTING WITH YOUR ALLERGIST OR DOCTOR BEFORE USE. THESE PRODUCTS MAY BE HAZARDOUS TO YOUR HEALTH.
DO NOT USE STEAM ROOM WHILE UNDER THE INFLUENCE OF ALCOHOL OR DRUGS, AS THIS CAN BE HAZARDOUS TO YOUR HEALTH.
YOUR SHOWER MAY BE A SLIP-AND-FALL HAZARD. CHECK WITH YOUR CONTRACTOR OR FLOORING MANUFACTURER REGARDING THE SAFE USE OF YOUR FLOORING IN A STEAM APPLICATION. SLIPPING AND FALLING INTO THE STEAMHEAD ITSELF OR INTO THE STREAM OF STEAM EMITTING FROM THE STEAMHEAD WILL CAUSE SERIOUS BURNS OR PHYSICAL INJURY.
IF YOU ARE FEELING UNCOMFORTABLE, DIZZY, FAINT, OR STARTING TO FALL ASLEEP, IMMEDIATELY EXIT THE STEAM ROOM.
DO NOT USE STEAM ROOM IF YOU ARE UNDER THE AGE OF 16 UNLESS SUPERVISED BY AN ADULT.
THERMASOL STEAM BATH GENERATORS ARE NOT DESIGNED TO BE USED FOR SPACE HEATING PURPOSES.
THERMASOL STEAM BATH GENERATORS ARE FOR INDOOR USE ONLY. THEY SHOULD NEVER BE LOCATED OUTSIDE THE HOME.
All products must be installed in accordance with installation instructions provided. Failure to do so may invalidate warranty at manufacturer’s discretion. ©2019 ThermaSol.

1a Important Installation step – continued
YOUR THERMATOUCH SMART TOUCHSCREEN CONTROL COMES WITH A PREINSTALLED EARTH GROUNDING WIRE ON THE BACK OF THE CONTROLLER. PRIOR TO INSTALLTION OF YOUR THERMATOUCH LOCATE THE CLOSEST EARTH GROUND (COPPER WATER PIPE) AND ATTACHED THE WIRE AS SHOWN BELOW.
IF YOU HAVE ANY QUESITONS ABOUT THIS PROCESS PLEASE CONTACT US AT SUPPORT@THERMASOL.COM OR BY PHONE AT 800.776.0711

THERMASOL TT7-SVSQ Therma Touch 7 Control - continued

Tools and Materials

THERMASOL TT7-SVSQ Therma Touch 7 Control - Tools and
Materials

Materials needed:
– ThermaTouch control
– M12 cable
– Silicone
– Power Distribution Module (PDM)
– Mud Ring
– Ethernet Cable with RJ-45 Connector (not supplied)
– Other materials as required

Back of Control

THERMASOL TT7-SVSQ Therma Touch 7 Control - Back of
Contro

REMINDER
in order to receive software updates the unit must be plugged into the internet using an Ethernet Cable connected to a Router (Router and Ethernet Cable not supplied).

Mud Ring Application

THERMASOL TT7-SVSQ Therma Touch 7 Control - Mud Ring
Application

Control Installation and Data Cable Connection

THERMASOL TT7-SVSQ Therma Touch 7 Control - Cable
Connection

Route the M12 cable through the finished wall to the back side of the control. (The other end of the cable runs to the PDM location.)
NOTE: It is recommended to run the cable through electrical conduit. DO NOT STAPLE the cable!
Run the M12 cable so the 90-degree end connection will connect to the ThermaTouch control. Then connect the M12 Cable to
ThermaTouch control. Do not over tighten.
If the Serenity Light, Sound, Rain Head option is not used then amplified speakers are required for sound.

THERMASOL TT7-SVSQ Therma Touch 7 Control - Turn Counter
Clockwise

  • Do not staple, strain or damage data cable
  • Align pins to receptacle visually before tightening
  • Do not force plug
  • Hand tighten only

DO NOT pinch, nail, staple, wedge, or bind the data cable.
DO NOT wrap the data cable around steam line or route it in a manner so that the hot steam line could melt the cable.
Any damage to the control cable will result in the control not working properly.
Carefully connect the data cable to the PDM and control BEFORE turning power on to the generator or PDM.

THERMASOL TT7-SVSQ Therma Touch 7 Control - Carefully
connect

Connect the data cable to Power Distribution Module (PDM).
(The other end of the cable runs to the back of the control in the shower location.)

Sealing Control

THESE STEPS MUST BE TAKEN FOR CORRECT INSTALLATION OF THE CONTROL. REMOVE MUD RING FROM WALL CUTOUT BEFORE MAKING FINAL CABLE CONNECTIONS TO THE THERMATOUCH CONTROL.
TEST THAT ALL CONNECTIONS ARE WORKING BEFORE SEALING THE CONTROL TO THE WALL.
(Power on the control and see that it lights up).

A Coat the entire groove on the control back with supplied waterproof silicone to fully seal the control to the wall.
Completely seal the control to the wall so moisture does not collect behind it.
Place the control on the wall pressing firmly.
(You may need to tape the control into place until the silicone dries.)
Be careful not to harm the wall or control with the tape. Let dry for 24 hours before using steam bath.

THERMASOL TT7-SVSQ Therma Touch 7 Control - Side View of
Surface

6a Connecting ThermaTouch to Generator

THERMASOL TT7-SVSQ Therma Touch 7 Control - Touch to
Generator

6b Connecting ThermaTouch to Serenity Light, Sound, Rainhead

THERMASOL TT7-SVSQ Therma Touch 7 Control - Serenity
Light

6c Connecting ThermaTouch to Digital Shower

THERMASOL TT7-SVSQ Therma Touch 7 Control - Digital
Shower

6b Connecting Total Wellness Package

THERMASOL TT7-SVSQ Therma Touch 7 Control - Wellness
Package

Steam Line and Steamhead

Now you will need to decide on the steamhead placement in the shower so you can run the steam line from the generator to the steamhead. There are a couple of things you need to know about the placement of the steamhead and steam line itself.

DO NOT install any valve in the steam line. Flow of steam must be unobstructed.
DO NOT plumb any traps in the steam line.
A The steam outlet on the generator requires a 1/2″ brass union for easy installation (not included).
B Use 1/2” brass pipe or copper tubing from unit to steamhead rough-in fitting as permitted by code.

The steam line can run up and then down, once; or horizontal; but never run down and then up. If it does, a steam trap will be produced at the low point blocking the flow of steam.
Insulate the steam outlet piping if the piping run exceeds 10 feet or is exposed to cold areas. Use steam rated insulation.
Pitch/angle steam lines back towards generator before any up or down turns; pitch/angle towards steam room after any up or down and avoid perfectly level plumbed lines.THERMASOL TT7-SVSQ Therma Touch 7 Control - Line and
Steamhead

Steamhead Location
DO NOT install the steamhead near the seating area or the user.
DO NOT forget to install the steamhead rough-in fitting!

C Install the steamhead 24″ from the floor or bathtub rim and 6″ from any corner.
Steamhead is to be mounted as far as possible from typical bathing position (seated or standing) and installed as far from the in-shower controller as possible.
For retrofit to existing finish wall: Drill a 1-1/8″ diameter hole in the shower wall or wall above bathtub rim for the steam outlet rough-in fitting and install to be flush with the finished wall. this housing must be sealed to the wall to not allow vapor or water behind it.
(plumbing must be done from backside of finshed space)
For new framing: Mount and install rough-in fitting to be flush with finished wall.
Connect a 1/2″ NPT brass pipe or copper tubing to the steam outlet union (not included) on the generator running the pipe to the steam head location in the wall to connect with the steamhead rough-in fitting. It is very important that the pipe is firmly secured to the wall, so that when the steamhead is installed it doesn’t push the rough-in fitting back into the wall. Install a 1/2” dropear elbow on the end of the 1/2” pipe or tubing for the rough-in fitting.
Use the installation tool to tighten the housing in place with a 1″ socket and driver. Then insert the protective cap into the housing.
For all the connections, use solder for copper joints and Teflon tape for pipe fittings and do not over tighten fittings.
DO NOT USE PVC CEMENT.

THERMASOL TT7-SVSQ Therma Touch 7 Control - floor or
bathtub

D Once the shower wall is complete and the housing is sealed to the wall, remove the protective cap and insert the steamhead into housing. Use the supplied silicone to adherethe steamhead to the wall sealing out any water from getting behind the head.
Use supplied o-ring lubricant to assist in steam head installation. A very small amount is all that is need directly on the o-rings.THERMASOL TT7-SVSQ
Therma Touch 7 Control - complete and the housing

Upon final installation mount steamhead with facing up to allow aromatherapy well to dispense steam.
For detailed installation instructions of the steamhead please see Installation section in thermasol.com/customer-support

Final Pre-Check Before Operation

Turn ON the water supply to the generator. Check all the connections for leaks.
Plug in generator (unless hardwired model).
Turn ON the power source or breaker.
Verify control panel lights up and test operation. Note: Initial power-on phase takes several minutes for generator to heat up steam.
Please direct the home owner to visit www.thermasol.com/solution and click on the “I’m the home owner” button to learn about set-up and programing (in order to set up the clock and any other options if applicable).

Trouble Shooting, Tutorials and Error Codes

Visit www.thermasol.com/solutions. Click on Troubleshoot then click on ThermaTouch Control Error Codes.

THERMASOL logo1958 STEAM WAY ROUND ROCK, TX 78665
PHONE: 800.776.0711 | FAX: 800.556.5257 | WWW.THERMASOL.COMTHERMASOL TT7-SVSQ Therma Touch
7 Control - icon 2Read warnings on page 2. For illustrative purposes only. Consult with qualified professional for steam room construction details.
THERMASOL.COM I 800.776.0711

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals