TOBI MANUALE SUCTION ASPIRATOR it ’s a manual device to be used for the emergency field to be used for the aspiration of the body liquids (mucus or catarrh or blood). Easily movable and designed for manual use. Thanks to these characteristics and to the rating that it has produced is particularly suitable for emergency use, on tracheostomized patients, minor surgical applications and post-operative therapy at home. Made of highly heat resistant, in conformity with the latest European safety standard, the product is supplied with a polycarbonate 0.4-liter autoclavable jar with an overflow valve.
GENERAL WARNING
Read the instruction manual carefully before use.
Only highly qualified staff use reserved the instrument must not disassemble.
For technical service always contact Gima S.p.A.
IMPORTANT SAFETY RULES
-
Check the condition of the unit before each use.
-
Respect the safety regulations indicated for electrical appliances and particularly:
– Use original components and accessories provided by the manufacturer to guarantee the highest efficiency and safety of the device;
-The device can be used only with the bacteriological filter;
– Place the instrument on stable and flat surfaces;
– Don’t touch the device with wet hands and always prevent the appliance from coming into contact with liquids;
– Keep off the reach of children or not capable people without supervision;
– Preserve and use the medical device in environments protected from atmospheric factors and at distance from heat sources;
– Don’t use the device for thoracic drainage. -
For repairs, exclusively contact technical service and request the use of original spare parts. Failure to comply with the above can jeopardise the safety of the device.
-
Use only for the purpose intended. Don’t use for anything other than the user defined by the manufacturer.
The manufacturer will not be responsible for damage due to improper use. -
Instrument and accessory discharging must be done according to current regulations in the country of use.
-
None of the mechanical parts has been designed to be repaired by customers or end-users. Don’t open the device, do not mishandle the mechanical parts. Always contact technical assistance.
-
Using the device in environmental conditions different than those indicated in this manual may harm seriously the safety and the technical characteristics of the same.
|
The manufactured cannot be held liable for accidental or indirect damages
should the device be modified, repaired without authorization or should any of
its components be damaged due to accident or misuse.
Any minimal modification/repair on the device voids the warranty and does not
guarantee compliance with the technical requirements provided by the MDD
93/42/EEC (and subsequent changes) and it’s normative.
---|---
TECHNICAL CHARACTERISTICS
Model | TOBI MANUALE SUCTION ASPIRATOR |
---|---|
TIPOLOGY (MDD 93/42/EEC) | Medical Device Class Ila |
Classification UNI EN ISO 10079-2 | MEDIUM VACUUM / 22Vmin |
Maximum suction aspiration (without jar) | -40kPa (- 0.40 bar) |
Weight | 1.150 Kg |
Dimension | 225 x 185 (h) x 85 mm |
Working condition | Room temperature: 5 ÷ 35°C |
Room humidity percentage: 30 ÷ 75% RH Altitude: 0 +2000m s.l.m
Conservation condition| Room temperature: – 40 ÷ 70°C
Room humidity percentage: 10 ÷ 100% RH
The technical specifications may change without notice Shelf life: maximum 5 years from the date of manufacture
ACCESSORIES SUPPLIES
- Complete aspiration jar 4000ml
- Conical fitting
- Transparent tubes set 6 mm x 10mm
- Hydrophobic and antibacterial filter
The filter is made of hydrophobic material and blocks the passage of liquids
that come into contact with it.
Replace it whenever you suspect that it may be contaminated and/or it becomes
wet or discolored.
Replace the filter every time it is used if the suction pump is used on
patients in unknown pathological situations and where an assessment of
indirect contamination is not
possible.
If, however, the patient’s pathology is known and/or there is no risk of
indirect contamination, the filter should be replaced after every work shift
or once a month even if the
the device is not used.
WARNING: Suction tubes for insertion in the human body purchased
separately from the machine should comply with ISO 10993-1 standard on
material biocompatibility.
WARNING: The medical device is provided without a specific suction probe.
If this device must be used with a specific suction probe, the end-user is
responsible for making sure it complies with the EN 10079-2 regulation.
CLEANING OF ACCESSORIES
To clean the plastic housing of the device wear disposable latex gloves and
clean with denatured alcohol or hypochlorite solutions.
Washing and/or cleaning the autoclavable jar as to be carried out as follows:
-
Wear protective gloves and apron (glasses and face mask if necessary) to avoid contact with contaminating
substances; -
Disconnect the jar from the device
-
Disconnect all tubes from the jar and the protection filter
-
Empty and dispose of the Jar according to the laws in force in your country;
-
Separate all parts of the cover (overflow valve, o-ring);
After disposing of disposable parts and disassembling the jar wash in running
cold water and rinse thoroughly.
Then soak in warm water (temperature shall not exceed 60°C). Wash thoroughly
and if necessary use a non-abrasive brush to remove incrustations.
Rinse in running warm water and dry all parts with a soft cloth (non-
abrasive).
The jar and the cover can be autoclaved by placing the parts into the
autoclave and running one sterilization stem cycle at 121°C (1 bar relative
pressure) making sure that
the jar is positioned upsidedown.
After sterilization and cooling at an environmental temperature of the parts
make sure that these are not damaged.
Assemble the jar as follows:
- Place the overflow valve into its seat in the cover (under VACUUM connector)
- Insert floating valve keeping the o-ring towards the opening of the cage
- Place the o-ring into its seat around the cover
- After completing assembling operations always make sure that the cover seals perfectly to avoid vacuum leakages or liquid exit
The aspiration tubes can be sterilized on autoclave using a sterilization cycle at 120°C. The conical connector can be sterilized on autoclave using a sterilization cycle at 121°C.
| DO NOT WASH, STERILIZE OR PUT IN AUTOCLAVE THE ANTIBACTERIAL FILTER
---|---
Aspiration jar : the mechanical resistance of the component is guaranteed
up to 30 cycles of cleaning and sterilization. Beyond this limit, the
physical-chemical characteristics of the plastic material may show signs of
decay. Therefore, we recommend that you change it.
Silicone tubes: the number of cycles of sterilization and/or cleaning is
strictly linked to the employment of the said tube. Therefore, after each
cleaning cycle, it is up to the final user to verify whether the tube is
suitable for reuse. The component must be replaced if there are visible signs
of decay of the material constituting the said component.
Conical fitting: the number of cycles of sterilization and the number of
cleaning cycles is strictly linked to the employment of the said component.
Therefore, after each cleaning cycle, it is up to the final user to verify
whether the fitting is suitable for reuse. The component must be replaced if
there are visible signs of decay in the material constituting the said
component.
PERIODICAL MAINTENANCE CHECKS
The TOBI MANUALE SUCTION ASPIRATOR does not need maintenance or lubrication.
It is necessary to check the functioning and instrument before every use.
Unpack the instrument and always check the integrity of plastic parts, they
might have been damaged during previous use. Close the aspirator outlet with
your finger.
Press the foot and check the vacuum functionally.
Type of fault | Cause | Remedy |
---|---|---|
1. No aspiration | Jar Cap badly screwed down | Unscrewed the cap, then re- |
screw it correctly
2. No aspiration| Lid seal is not in its seat| Unscrew the cap and insert the
seal prop- early in its seat
3. The float doesn’t close| The float it’s covered by dirty material|
Unscrewed the cap, leave the and put in on autoclave
4. The float doesn’t close| If the cap has been washed, ensure that the float
is not partially detached| Fit the float into its place
5. Low suction| Foam inside the jar| Fill the jar to 1/3 full of ordinary
water
6. No aspiration due to flow leakage of mucus| Filter blocked| Replace filter
7. The Vacuum power on the patient side is
either very low or absent|
- Protection filter blocked or dam-aged
- Connection tubes blocked, kinked or disconnected
- Shut-off valve blocked or dam-aged
- Pump motor damaged
|
- Replace the filter
- Replace or reconnect the tubes, check the jar connections
- Empty the jar, or disconnect the tube from the jar and unblock the shut-off valve. The unit will only work in the up-right position
- Refer to authorized service personnel
Faults 1 – 2 – 3 – 4 – 5 – 6 – 7| None of the remedies has achieved the desired results| Contact the seller or GIMA After-sales Assistance Service
If the overfill security system is activated, don’t proceed with the liquid
aspiration. If the overfill security system doesn’t work there are two cases:
1st case – If the overfill security system doesn’t work the aspiration will be
stopped by the bacteriological filter who avoiding the liquid penetration
inside the device.
2nd case – If both the security system and the bacteriological filter do not
work, there is the possibility that liquid has leaked inside the device, in
this case, return the device to GIMA technical service.
| BEFORE EVERY CHECKING OPERATION, IN CASE OF ANOMALIES OR BAD FUNCTIONING,
PLEASE CONTACT GIMA TECHNICAL SERVICE. GIMA DOES NOT GIVE A GUARANTEE IF THE
INSTRUMENT, AFTER THE TECHNICAL SERVICE CHECKING, APPEARS TO TAMPER.
---|---
INSTRUCTION FOR USE
Connect the short silicon tube, with an antibacterial filter, to the suction
connector. The other tube, with one end connected to the filter, must be
connected with the other end o the jar’s lid connector where has been fixed
the red float. When 90% of the volume of the jar is reached there is the
activation of the security float (the float closes the aspiration connector on
the jar) to avoid liquid penetration inside the device.
The device must be used on a plan of horizontal operation.
Filter assembling
Make sure the filter is assembled with the arrows on the side of the
patient.
WARNING: The inside of the medical device must be regularly checked for the
presence of liquids or other visible contamination (secretions). In the
presence of liquids or other visible contamination, immediately replace
the medical device due to the risk of an insufficient vacuum flow rate.
These products have been designed, tested, and manufactured exclusively for
single patient use and for a period no longer than 24 hours.
- Connect the long silicon tube to the other jar’s lid connector
- Connect the other end of the long silicon tube to the probe plastic connector then connect the suction probe to it.
- Unscrew the jar’s lid and fill the jar 1/3 full of ordinary water (this for easy cleaning operations and a rapid reaching of the functionality vacuum) the re-screw the lid on the jar correctly.
- Push foot to start the suction.
- To extract the accessories and start with cleaning as written in the clean chapter
|
NEVER USE THE DEVICE WITHOUT A JAR AND / OR PROTECTION FILTER MAKE SURE THAT CHILDREN AND/OR MENTALLY ILL PEOPLE DO NOT USE THE DEVICE WITHOUT ADULT SURVEILLANCE
---|---
SYMBOLS
| Caution: read instructions (warnings) carefully| | Consult instructions for
use
---|---|---|---
| Keep in a cool, dry place| | Keep away from sunlight
| Manufacturer| | Date of manufacture
| Product code| | Lot number
| Medical Device complies with Directive 93/42/EEC| | Serial number
| Temperature limit| | Humidity limit
GIMA WARRANTY TERMS
The Gima 12-month standard B2B warranty applies.
| 28220
---|---
| Gima S.p.A.
Via Marconi, 1 – 20060 Gessate (MI) Italy
gima@gimaitaly.com –
export@gimaitaly.com
www.gimaitaly.com
Made in Italy
M28220-M-Rev.7-02.21
Documents / Resources
| GIMA
TOBI Manuale Suction
Aspirator
[pdf] User Manual
GIMA, TOBI, Manuale, Suction, Aspirator
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>