apuro GL346-A Water Boiler Instruction Manual
- June 6, 2024
- apuro
Table of Contents
- Safety Tips
- Product Description
- Introduction
- Pack Contents
- Operation
- Thermal Cut-Out Reset
- Serving
- Cleaning, Care & Maintenance
- Troubleshooting
- Technical Specifications
- Electrical Wiring
- Compliance
- DECLARATION OF CONFORMITY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
**apuro GL346-A Water Boiler Instruction Manual
**
Safety Tips
- Position on a flat, stable surface.
- A service agent/qualified technician should carry out installation and any repairs if required. Do not remove any components on this product.
- Consult Local and National Standards to comply with the following:
- Health and Safety at Work Legislation
- Fire Precautions
- Wiring Regulations
- Building Regulations
- Ensure the location for the appliance can support its weight when full.
- DO NOT fill the appliance above the ‘MAX’ level.
- DO NOT move the appliance when full.
- DO NOT immerse the appliance in water.
- DO NOT leave the machine unattended during operation.
- DO NOT operate this appliance when less than one third full.
- DO NOT touch the outer surfaces of the appliance. They become hot during use.
- Suitable for indoor use only.
- Always switch off and disconnect the power supply to the appliance when not in use.
- Keep all packaging away from children. Dispose of the packaging in accordance to the regulations of local authorities.
- If the power cord is damaged, it must be replaced by an Apuro agentor a recommended qualified technician in order to avoid a hazard.
- Please ensure that the tap is screwed fully on before use.
- Apuro recommend that this appliance should be periodically tested (at least annually) by a Competent Person. Testing should include, but not be limited to: Visual Inspection, Polarity Test, Earth Continuity, Insulation Continuity and Functional Testing
Product Description
- GL346-A – 10.5 litre Stainless Steel Water Boiler
- GL347-A – 20 litre Stainless Steel Water Boiler
- GL348-A – 30 litre Stainless Steel Water Boiler
- GL349-A – 40 litre Stainless Steel Water Boiler
Introduction
Please take a few moments to carefully read through this manual. Correct maintenance and operation of this machine will provide the best possible performance from your Apuro product.
Pack Contents
The following is included:
- Apuro Water Boiler
- Tap adapter
- Instruction manual
Apuro prides itself on quality and service, ensuring that at the time
ofpackaging the contents are supplied fully functional and free of damage.
Should you find any damage as a result of transit, please contact your Apuro
dealer immediately.
Operation
-
Remove the appliance from the packaging. Make sure that all protective plastic film and plastic coatings are thoroughly removed from all surfaces.
Note: Before using for the first time, clean the interior of the appliance and all parts in warm soapy water, then rinse thoroughly. -
. Ensure the Temperature Control knob is set to ‘OFF’.
-
Remove the lid and fill the appliance to at least half of its capacity.
-
Replace the lid.
-
Connect to the mains power supply.
-
Set the Temperature Control knob to the required temperature setting. The ‘BOIL’ indicator light illuminates and the appliance begins to heat water.
WARNING: Reduce the set temperature if the water begins to boil. DO NOT allow the water to boil constantly. -
When the water has reached the set temperature the ‘BOIL’ Indicator light turns off and the ‘KEEP WARM’ indicator light illuminates.
Note: Once the water temperature drops 5-10ºC then the appliance will reheat the water.
WARNING: If the Temperature Control Knob is set to or close to ‘HIGH’ then the appliance will constantly heat the water until knob is turned to ‘OFF” or the temperature is reduced.
Thermal Cut-Out Reset
This appliance is fitted with a Thermal Cut-Out safety feature. Should the
temperature exceed safe levels the appliance will automatically cut power.
The Safety Cut-out switch is located on the underside of the appliance. To
reset the appliance:
-
Empty the appliance and allow to cool.
-
Press the reset button until it clicks.
WARNING: Ensure the appliance has cooled down and is empty before resetting the switch, as it may need to be tipped slightly to gain access to the switch. -
The appliance is now reset and can be used as normal.
Serving
- Place a suitable vessel beneath the tap.
- Pull the tap towards you or push tap away from you to begin pouring.
- Raise the tap handle to close the tap.
Serving (using the hands free tap adapter)
Emptying the Appliance
Drain the appliance by using the tap to empty.
Cleaning, Care & Maintenance
- Always turn off and disconnect the appliance from the power supply before cleaning.
- Use soapy water and a damp cloth to clean the exterior of the appliance.
- Dry thoroughly after cleaning.
De-scaling
In hard water areas limescale can build up within the appliance after
prolonged use. For best taste and
extended appliance life, de-scale it regularly. Installation of a water
filtration system is also recommended.
To de-scale the appliance:
- Pour a solution of de-scaler and water into the appliance.
- Brush the interior gently with a soft bristled brush.
- Discard the solution collected in the jug.
- Fill the appliance with clean water and turn back On to flush out the system. Flush out the system thoroughly to remove any de-scaler residue.
- The appliance is now ready for use.
Note: Use a suitable de-scaler and always follow the instructions on the
container.
Apuro recommend that this appliance is de-scaled every 3 months or more
frequently in hard water areas.
IMPORTANT: Failure to de-scale or maintain will invalidate your
guarantee.
Troubleshooting
Fault
| Probable Cause| Solution
---|---|---
The unit is not working| The unit is not switched on|
Check the unit is plugged in correctly and switched on
Plug or lead is damaged
| Call Apuro agent or qualified Technician
Power supply|
Check power supply
Thermal fuse has activated
|
Reset Thermal fuse (see page 4)
Power light comes on but water does not reach temperature
| Thermostat fault|
Call Apuro agent or qualified technician
The tap is leaking| The tap has become loose| Tighten the tap handle
Technical Specifications
Model
| ****
Voltage
| ****
Power
| ****
Current
| Capacity (litres)| Weight (full)
(kg)
| Approx. Heating Time (Max.
Temp. when full)
| Dimensions h x w x d mm
---|---|---|---|---|---|---|---
GL346-A| 230V 50Hz| 2200W| 9.6A| 10| 16.8| 25
minutes|
470 x 313 x 326
GL347-A|
230V 50Hz
| 2200W| 9.6A| 20| 29.2| 50 minutes| 535 x 369 x
380
GL348-A| 230V 50Hz| 2200W| 9.6A| 30| 40.4| 70
minutes|
519 x 433 x 440
GL349-A
| 230V 50Hz| 2200W| 9.6A| 40| 48.2| 100 minutes| 630 x 433 x 440
Electrical Wiring
The plug is to be connected to a suitable mains socket.
This appliance is wired as follows:
- Live wire (coloured brown) to terminal marked L
- Neutral wire (coloured blue) to terminal marked N
- Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the
event of any emergency disconnection being required they must be readily
accessible.
Compliance
The product must not be disposed of as household waste. To help prevent
possible harm to human health and/or the environment, the product must be
disposed of in an approved and environmentally safe recycling process. For
further information on how to dispose of this product correctly, contact the
product supplier, or the local authority responsible for waste disposal in
your area.
APURO parts have undergone strict product testing in order to comply with
regulatory standards and specifications set by international, independent, and
federal authorities.
APURO products have been approved to carry the following symbol:
All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of APURO. Every effort is made to ensure all details are correct at the time of going to press, however, APURO reserve the right to change specifications without notice.
DECLARATION OF CONFORMITY
UK:
This product is UKCA marked to demonstrate compliance with the applicable
requirements of the conformity assessment procedure(s).
A Declaration of conformity may be found at {URL & QR code} or by scanning the
QR code below.
ANZ:
This product is RCM marked to demonstrate compliance with the applicable
requirements of the conformity assessment procedure(s).
A Declaration of conformity may be found at {URL & QR code} or by scanning the
QR code below.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>