maxell MXHM-1000 llexam01 Hand Massager User Manual
- June 6, 2024
- Maxell
Table of Contents
maxell MXHM-1000 llexam01 Hand Massager User Manual
Content of The Package
Introduction
About the user manual
- Contents of this user manual might be changed in the future without prior notice.
- For product improvement, change of appearance or specification might not be announced in advance.
- Except for personal use, any unauthorized copying of part or all parts of this manual is prohibited. Unauthorized republication is strictly prohibited.
Disclaimer
- Maxell shall not be responsible for any damage caused by fires, earthquakes, action of a third party, any accidents, intended or unintended misuse or other usage under abnormal conditions.
- All explicit and implicit contents not stated in the warranty card are not covered.
- Maxell shall not be responsible for failure due to any damage caused by usage other than described in the instruction manual.
- This product is not intended for use with equipment and devices related to human life such as medical equipment and devices, nuclear equipment and devices, aerospace equipment and devices, transportation equipment, and equipment and devices which require a high standard of reliability. We assume no responsibility if this product is used for the control systems of these types of equipment and devices and if any injury or fire occurs due to failure of the product.
Safety caution
Please be sure to observe it for safe use.
Danger: Danger refers to misuse which might lead to death or serious injury *1 to a high degree.
Warning: Warning refers to misuse which might lead to death or serious injury*1
Caution: Caution refers to misuse which might lead to injury *2* and
may cause property damage 3 .
1: Severe injury is indicated by those that have after effects such as
blindness, injury, burns (high temperature burns/ low temperature burns,
chemical burns), electric shock, fracture, poisoning, etc. and those requiring
hospitalization or longterm regular hospital visits or treatment.
2:** Injury refers to burnt, electric shock which do not result in
hospitalization or long-term follow-up consultation
*3: Damages refers broad damages to houses or properties and domestic
animals/pets.
Example of symbols
Prohibited actions when handling the product. Graphic symbols representing specific instructions are shown in black color in the shape of .
Caution to fire, electric shock, high temperature when handling the product. Graphic symbols representing specific instructions are shown in black color in the shape of .
Instruction which must be followed. Graphic symbols representing specific instructions are shown in white color in the shape of.
Danger
Only use the dedicated power adapter
When using or charging this device, use the dedicated power adapter.
This may cause overheat, fire, accident, electric shock or injury.
Do not touch leaked liquid
Do not touch any liquid leaking from the inside of this product. If it gets into your eyes, wash your eyes with clean water without rubbing and see a doctor immediately. It may cause blindness.
Warning
Do not use the device if you have any of the following conditions.
Those who are recommended not to have massages by a doctor Example: People with thrombosis (embolism), severe aneurysm, acute varicose veins, various dermatitis, skin infections (including inflammation of subcutaneous tissue), etc.
This may cause accident or discomfort.
Do not use if you are incapable of indicating your feeling of pains or if you are physically disabled This may cause accident or injury.
Do not allow infants or small children use or play with it This may cause accident or injury.
Do not disassemble or remodel
This may cause overheating, electric shock or injury
Do not disassemble for purposes other than disposal
This may cause fire, electric shock or injury.
Do not use the power adapter with a voltage other than the specified power
supply voltage.
It may cause electric shock or fire. The input voltage of the power adapter of
this product is AC100–240V.
People with any of the following conditions should consult a doctor.
- People who use implantable medical electrical equipment such as pacemakers that are susceptible to electromagnetic interference
- People with malignant tumors.
- People with heart problems
- People with loss of temperature sensation
- People in the unstable period of early pregnancy or immediately after childbirth
- People with sensory impairment due to severe peripheral circulatory disorders such as diabetes
- People with wounds on the skin
- People who need rest
- People with a body temperature of 38°C or higher (fever): People with severe acute inflammatory symptoms (malaise, chills, blood pressure fluctuations, etc.), people who are debilitated
- People with osteoporosis, people with acute (painful) diseases such as spinal fractures, sprains, and pulled muscle
- Or others who are being treated at a medical institution
- People with tendonitis
This may cause accident or discomfort.
Before use, make sure that the main unit is not deformed, cracked, or damaged, and that the protective cover is not damaged. It may cause an accident or injury. If any abnormality is found, stop using it immediately and contact your dealer or the manufacturer.
If the device has not been used for a while, read the instruction manual
carefully and make sure that the operation buttons and timer of this device
operate normally before use
It may cause an accident or injury.
If you feel any abnormality in your body during use, or if it does not show
any effect after using it for a while, stop using it immediately and consult a
doctor
It may cause an accident or discomfort.
If symptoms such as rash, redness or itch appear after using this device,
discontinue use and consult a doctor.
It may cause an accident or discomfort.
Since the heater of this device gets hot, people who are not sensitive to heat
should use it with great care.
It may cause low temperature burns.
Do not use for purposes other than those described in the instruction manual
This may cause accident or injury.
Do not use except for hands
This may cause accident or injury.
Do cover the device with foreign objects such as towels or cushions
It becomes hot and may cause smoke or re.
Do not use in highly humid locations such as bathroom
This may cause electric shock, malfunction, mold.
Do not use with wet hands
This may cause overheat, electric shock , malfunction.
Do not splash or soak in water
This may cause electric shock or malfunction.
Do not put into a fire
This may cause smoke, fire, rupture.
Do not step on, drop or apply strong shock to the device
This may cause injury or malfunction.
Do not use the power adapter with a loose outlet
Do not use the outlet that is loose when the power adapter is plugged in. It
may cause fire or electric shock
Do not cover the power adapter with a cloth or cover
The heat builds up and the case may be deformed, which may cause a fire or
electric shock.
Plug the power plug to USB cable outlet firmly
Partially plugged AC adaptor may cause to fire or electric shock.
If it does not operate or if there is an abnormality with it, immediately stop
the operation or charging, unplug the power plug from the outlet, and turn off
the power of the main unit.
This may cause electric shock , fire, overheat.
When unplugging the power plug, be sure to hold the power plug not the USB
cable
It may cause electric shock, short circuit or fire.
Be sure to unplug the power
adapter from the outlet when it is not used for a long time
It may cause electric shock or electric leakage fire due to insulation
deterioration.
Do not damage, forcibly bend, twist, put heavy objects on, pinch, bundle, or
modify the power cable and USB Cable
This may cause electric shock or fire.
Do not place in cooking equipment such as microwave oven or high pressure
vessel.
This may cause smoke or fire.
Do not store in the refrigerator
This may cause injury or malfunction.
Do not use and store in locations of high temperature
Do not place it in a location where it will be hot such as near fire, stove,
direct sunlight, in the car under the scorching sun. It may cause accident,
malfunction, smoke or fire.
When cleaning, be sure to turn off the power and unplug the power plug from the outlet . This may cause electric shock or injury.
Caution
Make sure that no foreign matter is caught inside the main unit before use
This may cause accident or injury.
When using for the first time, use with intensity level 1
This may cause accidents or physical deterioration.
Place the main unit on a horizontal surface and use it
This may cause malfunction or injury.
The usage time should within 10 minutes each part.
Continuous usage may result in muscular or neuropathic pain.
Do not use with accessories such as rings, bracelets, and decorative nails
This may cause accident or injury.
Do not use if you have long nails.
This may cause injury..
Do not use immediately after eating or after consuming alcohol
This may cause physical deterioration, accidents or injury.
Does not sleep during use
Unconsciousness use may cause you to feel unwell or injured.
Do not use at the same time with other treatment devices
This may cause physical deterioration, accidents.
Do not use with multiple people at the same time
This may cause malfunction or accidents.
Do not use with both hands.
This device is for one hand only.
Do not use for pets
This may cause injury.
Do not use chemicals for cleaning
Do not wipe with chemicals such as benzine, thinner or alcohol. In addition to
deteriorating the exterior, it may cause the parts to melt.
Clean the power plug regularly to prevent dust accumulating to it
This may cause electric shock, short or fire.
Charge once every 6 months
The battery is completely discharged and cannot be used.
Product Features
This is a controlled medical device that massage the hand by pressurizing the airbag. Wrap the entire hand from the fingertips to the wrist and massage. Equipped with a heating and vibration function, you can relax with comfortable vibration while gently warming your hands
Intensive care for hands with 3 functions
Pressurization
Massage with a 10-layer airbag.
Heating 42°C※
Gently warm a wide area from your fingertips to the palm of your hand.
※Heating 42°C is a reference temperature.
Vibration
Further relaxation with vibration function
Massage the entire hand from fingertips to wrists
Designed for female hand structure
Provide a position guide and massage at the position where it fits.
Relax with 4 patterns of LED illumination
3 intensity level
Short treatment of 10 minutes at a time
USB rechargeable + portable
Use antibacterial cloth
Purpose of Use / Effect
A substitute for massage For general household use.
- Recovery from fatigue
- Promotion of blood circulation
- Relieve muscle fatigue
- Relieve muscle stiffness
- Relieves neuralgia and muscle pain
Name of Each Part
[Operation unit]
Power Adapter
USB Cable
Before Using
Make sure that the main unit is not damaged, or the cloth is torn before using it. Make sure that the operation buttons and timer of this device operate normally before use. If any abnormality is found, stop using it immediately and contact your dealer or the manufacturer
Charging
This device has a built-in lithium-ion battery. Please charge it before use.
-
Connect the included USB cable to the power adapter
-
Connect the USB cable to the main unit and connect the power plug to the power outlet.
-
The power button on the main unit blinks slowly and charging starts.
-
Charging is complete when the power button lights up. (Charging time: approx. 3 hours)
Caution
- The device can be used with the power adapter and USB cable connected
- The main unit cannot be charged while being used with the power adapter and USB cable connected.
- When storing, please charge once every 6 months. The battery may be completely discharged and cannot use.
- It can be used approximately 7 times when fully charged. (using all functions with intensity level 3)
- The usage time varies depending on the usage environment and load.
Usage
When using it, it is recommended to wear vinyl gloves to prevent the device from getting dirty.
When hand cream is applied on hands, please use vinyl gloves. The provided vinyl gloves are disposable, so please do not reuse them even after washing. Please purchase and use the ordinary vinyl gloves.
-
Place your hand in
Follow the position guide and place your hand in. Palm is facing down -
Turn on the power
Press and hold the power button for about 2 seconds.
When the power is turned on, all functions (pressurization function, heating function, vibration function) are turned on.
The intensity is Level 1.
The relax light is a gradient mode.
The operation will stop automatically after approximately 10 minutes.
-
Intensity Selection Button
You can switch the air pressure intensity with a short press of the power button.
If you are using for the first time, please use from intensity level 1.
-
Select the Heating Function
You can switch the function ON / OFF with a short press of the Hot button. When the LED of the Hot button is not lit, the function is OFF, and when it is lit, the function is ON
-
Vibration Function
You can switch the function ON / OFF with a short press of the vibration button. When the LED of the vibration button is not lit, the function is OFF, and when it is lit, the function is ON.
-
Select a Color for the Relax Light
You can change the color of the relax light by short-pressing the LED button.
At the beginning of the operation, it lights up with gradation, and the color changes each time the switch is pressed.
-
Power Off
To stop using it during operation, press and hold the power button for about 2 seconds.
Caution
- If you feel any pain during use, stop using the device immediately.
- Please use the device for less than 10 minutes per body part per day.
- Even if the function and strength are changed during use, the operation will stop 10 minutes after the power is turned ON.
- The pressurization function cannot be turned OFF.
Maintenance
Wipe off any dirt with a soft, dry cloth. If it is extremely dirty, soak a soft cloth in water, squeeze it well, and then wipe it gently.
Caution
Troubleshooting
(If failure is suspected, check the following)
Phenomenon | Cause | Solution |
---|---|---|
Cannot be charged | The connected cable and terminal not match | Use the |
included USB cable
Using a power adapter other
than the dedicated power adapter
| Use a dedicated power adapter
Stored for a long time, the battery has completely discharged| Cannot be used.
Please charge at least once every 6 months to avoid completely discharge
The power does not turn on| The time to press and hold the power
button is short| Press and hold down the Multi Button for approx. 2 seconds
The battery is exhausted| Charge the main unit
Does not vibrate| The vibration function is turned off| Check if the
vibration button is lit.
If it is not lit, press the vibration button to turn on the function
Does not warm up| The heating function is turned off| Check if the Hot button is lit.
If it is not lit, press the Hot button to turn on the function
The intensity of the massage is strong| The setting is high| Lower
the strength setting
The intensity of the massage is weak| The setting is low| Raise the
strength setting
It stopped operating| The power was turned off
because 10 minutes had passed since the start
| This device will automatically stop in approx. 10 minutes
The battery is exhausted| Charge the main unit
Device Disposal
This product is equipped with a lithium-ion battery. Be sure to remove the lithium-ion battery when disposing of it. Do not disassemble except when disposing of the product
Danger
Do not charge or do the following with the removed lithium-ion battery. (Causes of heat generation, ignition, and explosion)
- Do not put in fire or overheat.
- Do not pierce with nails, impact, disassemble or modify.
- Do not let positive terminal and negative terminal contact with metal.
- Do not carry or store with metals such as necklaces and hairpins.
- Do not use under high temperature such as near a fire or under the scorching sun
Warning
Keep the removed lithium-ion battery out of the reach of infants and children
If you think you have swallowed it, consult a doctor immediately.
If the liquid of the lithium-ion battery leaks, perform the following treatment without touching it with bare hands.
- Should this get in your eyes, immediately wash your eyes with clean water without rubbing your eyes and consult a doctor.
- If the liquid gets on your body or clothes, rinse it thoroughly with clean water and consult a doctor.
How to remove the lithium-ion battery
If you do this, you will not be able to use this product.
Caution
Before disassembling, use the device until the main unit is completely stops operating , and make sure that the power does not turn on. It may cause the battery to short-circuit.
-
Turn the body over and remove the rubber parts and screws (5 places). Be careful not to get injured when removing the rubber parts.
-
With the main unit facing up, slide the upper case and remove the two screws.
-
Turn it over again and remove the rubber feet and screws. (4 places)
-
Remove the lower case and disconnect the battery cords one by one.
Note: If you cut them in a bundle, it may cause the battery to short- circuit. Be sure to cut the cords one by one.
-
Apply tape to the tip of each cord.
Caution
- Be careful not to get injured during disposal.
- When removing the lithium battery, do not touch the leads (red and black). It may cause a short circuit and burns.
- Do not bend the battery, apply strong force, or damage it.
After use, do not throw it away as household waste, but take it to a recycling partner store. Used rechargeable batteries are a valuable resource. Since it will be reused, cover the input / output terminals with tape, etc., and bring it to the nearest rechargeable battery recycling partner store. Alternatively, put it into the “rechargeable battery recycling box”.
Specification
Classification | Mechanical equipment 77 vibrator |
---|---|
Product Name | Household electric massager |
Medical Device Classification | Controlled medical device |
Brand name | Hand massager Ilexam01 |
Input Voltage / Current | DC5V/Max 2A |
Power Consumption | 20W (HeatersW) |
Rated Usage Time | 10mins |
Dimensions | 170x245x109mm |
Weight | Approx. 1150g |
Air Pressure | Approx. below 108 kPa |
Vibration | Below 4290 times/mins |
Maximum Heater Temperature | Approx. 45°C |
Operating Temperature | 10-40°C |
Charging Time | Approx. 3hrs |
Manufacturer | Xiaman Emoka Health Science &Technology Co.,Ltd. China |
Manufacturer and Distributor | QUIX, Ltd. 401 YSK Building 1-2-5 Uchihonmachi, |
Chuo-ku, Osaka-shi Tel : 06-7176-0565
Power Adapter| Input| AC100-240V 50/60Hz
---|---|---
Output| DC5V/Max 2A
USB Cable| Length| Approx. 1m
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>