Qubino GOAEZMNHWD1 Flush RGBW Dimmer User Manual

June 6, 2024
QUBINO

Qubino logo

Qubino GOAEZMNHWD1 Flush RGBW Dimmer -figure

Qubino
Flush RGBW Dimmer
SKU: GOAEZMNHWD1

Quickstart

This is a Light Dimmer for Europe. To run this device please connect it to your mains power supply Include the R G B.W. color LED Dimmer into the 2- Wave network. press service Dutton 3 times in 2 seconds. If the device is properly included the green light will remain on.

Important safety information

Please read this manual carefully Failure to follow the recommendations in this manual may be dangerous or may violate the law of The manufacturer. importer. distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures reliable communication by reconfirming every message (two-way communication) and
every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is
not in direct wireless range of the transm _Mr__

This device and every other certified 2-Wave device can be used together with any other certified 2- Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it wins communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise, it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology. devices. white papers etc please refer to www.z-wave.info.

Qubino GOAEZMNHWD1 Flush RGBW Dimmer -figure 1

Product Description

Rubino Flush RGBW module is used to control RGELRGEIW strips and LED strips or bulbs to create countless color options and has 5 special scene effects. It can also control halogen lights and fans Its extremely small size allows for easy installation behind wan sockets and switches. Controlled devices may be powered by 12 or 24 VDC. All IN and OUT terminals may be user configured for LED control or 100 kf) signal readouts.

Prepare for Installation / Reset

Please read the user manual before installing the product_

In order to include (add) a 2-Wave device to a network, it must be in the factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows being reset without any involvement of a 2-Wave controller. This procedure should only be used when the emery controller is inoperable.

Please note that re-including the product will reset the data to the default values. Use this procedure only in tile event that the network primary controller is missing or others-use inoperable.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guickNineshorms may do works with mains power. Prior to the assembly of the product. the voltage network has to be switched off and ensured against re-switching.

Installation

– Before the installation disconnect the power supply (12-24VDC)
– Connect the module according to the electrical diagram.

Electrical DiagramQubino GOAEZMNHWD1 Flush RGBW Dimmer -figure
2

Notes for diagram:

12/24VDC – Power supply IN4 – Potential free / 100KCI
GND – Power supply ground R – Output assigned to IN1
IN1 – Potential free / 100K0 G – Output assigned to IN2
IN2 – Potential free / 100K0 B – Output assigned to IN3
IN3 – Potential free / 100K0 W – Output assigned to IN4

– Pull the antenna out of the holder
– Locate the antenna far from metal elements (as far as possible).
– Do not shorten the antenna.

Warning!

  1. The RGBW Controller is suggested to operate in low voltage circuits of 12VDC or 24VDC. Connecting a higher voltage load may result in RGBW Controller damage. Please refer to the following table.
    The current of RGBW Strip| Stranded Wire
    ---|---
    High current| 18 AWG
    Low current| 22 AWG
  2. The RGBW Controller must be powered by the same voltage as the connected light source. I.e. if controlling the 12V LED strip, the module must be connected to a 12V power supply. Similarly, if controlling the 24V RGBW strip, the RGBW Controller must be powered by a 24V voltage supply.
  3. The RGBW Controller has 100KΩ input. There is no 100KΩ output. Output is controlled by PWM at 488Hz.
  4. The RGBW Controller must be powered by 12VDC or 24 VDC stabilized power supply with outputs load capacity matched to loads voltage.
  5. In the case of connecting long RGBW/RGB/LED strips voltage drops may occur, resulting in lower light brightness further from R/G/B/W outputs. To eliminate this effect it”s recommended to connect a few shorter strips in parallel connection instead of one long strip connected serially. The Maximum recommended wire length, used to connect R/G/B/W outputs with an RGBW/RGB/LED strip is 10 m. Observe connected loads manufacturer recommendations towards connection wire diameter.
  6. For the connection of IN1~IN4, it is suggested that you connect the 4 inputs individually to the same type of device. The devices can be as follows: the rotary switch, the toggle switch, or the push switch.
  7. When the Controller is damaged or lost, and you have already transferred the control function to an external control switch before, the product can be normally operated. In another case, please purchase a new Controller, press the Include/Exclude Button three times to exclude the device, and then include the device with the original installation steps, the device can be restored to normal operation. Please note that reincluding the product will reset the data to the default values. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.

Inclusion/Exclusion

On factory default, the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the
devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion are then performed doing a special manual action right on the device.
Inclusion
Include the R.G.B.W. color LED Dimmer into the Z-Wave network, press the service button 3 times in 2 seconds. If the device is properly included the green light will remain on.
Exclusion
Exclude the Flush RGBW Dimmer into the Z-Wave network, press 3 times in 2 seconds. If the device is properly excluded, the green light will blink and data will be reset to the factory default values.
Auto-Inclusion
Besides the standard inclusion, these devices support the so-called auto inclusion. Right after powering up the device remains in an inclusion state and can be included by (any) gateway without further actions on the device itself. The auto inclusion mode will time out after some time.

Product Usage

Qubino GOAEZMNHWD1 Flush RGBW Dimmer -figure 3

  1. Connect the R.G.B.W. Color LED Dimmer according to the wiring diagram.
    – First, connect RGBW strip, outputs (R,G,B,W) RGB/RGBW/LED diodes, halogen lights, or inputs (IN1~IN4).
    – Second, connect the power supply.
    If the device is properly connected, the RGBW strip will blink once. Note that the device must be powered by a dedicated stabilized power adapter.

  2. In the status of the factory default (Not Paired), the red light and green light will blink by turns, eg. red, green, red, green, etc..

  3. Include the R.G.B.W. Color LED Dimmer into the Z-wave network, press the service button 3 times in 2 seconds. If the device is properly included, the green light will remain on.

  4. Exclude the Flush RGBW Dimmer into the ZWave network, press 3 times in 2 seconds. If the device is properly excluded, the green light will blink and the data will be reset to the factory default values.

  5. Please pull out the antenna and keep it at 90 degrees to enhance the RF signals.

  6. Support auto inclusion: Install the device, connect with the power, and the auto inclusion function will work in about 2 minutes.

  7. Support remote exclusion: Through configuration setting. Please refer to the following table.

IL) Size Value
240 1 byte 1

LED indication

Status| LED Signal

Solid Red

| Remark
---|---|---
Not Paired
Paired up| Solid Green|
Inclusion| Blinking Green (Interval: 1| Touch three times (Must release in 2 sec.)
Exclusion| Blinking Green (Interval: 1| Touch three times (Must release in 2 sec.)
Auto inclusion| Blinking Green (Interval: 1sec.)| Connect/disconnect power to connect with Z-wave network
Hardware button| | 1.   Add device
2.   Delete device
3.   Restore to the default value
4.   Set association
Input (11-14)| | Control RGBW channel(I1:R -I4:W)
Input type| Remark
---|---
Momentary| Monostable or push-button switch
Toggle| Bistable switch
Toggle w/Memory| ON: Active for closing terminals
OFF: Active for opening terminals
Input operating mode| Remark
---|---
Normal| Each given switch key assigned to one output channel
Brightness| All channels are controlled together
Rainbow| transition through all colors .pectrum (Operates on RGB channels only)

Quick troubleshooting

Here are a few hints for network installation if things don’t work as expected.

  1. Make sure a device is in a factory reset state before including. In doubt exclude before include.
  2.  If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise, you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Don’t poll FLIRS devices.
  6. Make sure to have enough mains powered devices to benefit from the meshing

Association – one device controls another device
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, …). In case the event happens all devices stored in the respective association group will receive the same wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however, the certain configurations can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 … 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In the case of a two- byte value, the same logic applies: Values greater than 32768 may be needed to be given as negative values too.
Parameter 1: Input switch type
NOTE: Please power cycle the device when the parameter is changed.
Size: 1 Byte, Default Value: 1

Setting Description
1 bi-stable switch type
2 monostable (push button) switch type

Parameter 2: Switch mode
NOTE: Using this parameter, it is possible to select various modes of RGBW Dimmer operation.
Size: 1 Byte, Default Value: 1

Setting Description
1 Normal Mode
2 Brightness Mode
3 Rainbow Mode

Parameter 3: Auto scene mode set
NOTE: Activation of the programmed scene changing color shades.
Size: 1 Byte, Default Value: 0

Setting Description
1 Ocean
2 Lightning
3 Rainbow
4 Snow
5 Sun

Parameter 4: Auto scene duration
NOTE: Using this parameter, it is possible to change Auto scene mode duration.
Size: 1 Byte, Default Value: 3

Setting Description
1 – 127 delay duration is from 1s to 127s
-127 delay duration is from 1min. to 127min.

Parameter 240: Remote exclusion
Support remote exclusion: Through configuration setting.
Size: 1 Byte, Default Value: 0

Setting Description
1 Remote exclusion

Technical Data

Dimensions 41x32x15 mm
Weight 14 gr
Hardware Platform ZM5101
EAN 3.83E+12
IP Class IP 20
Voltage 12 / 24V DC
Load At 12V- 156W combined; At 24V- 312W combined
Device Type Light Dimmer Switch
Generic Device Class Multilevel Switch
Specific Device Class Routing Multilevel Switch
Network Operation Always On Slave
Firmware Version 2.07
Z-Wave Version 4.18
Certification ID ZC10-17015398
Z-Wave Product Id 0159.0001.0054
Frequency Europe – 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

  • Basic
  • Switch Binary
  • Switch Multilevel
  • Switch Color
  • Association Grp Info
  • Device Reset Locally
  • Zwaveplus Info
  • Configuration
  • Manufacturer Specific
  • Powerlevel
  • Firmware Update Md
  • Association
  • Version

Explanation of Z-Wave specific terms

Controller — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways, Remote Controls, or battery-operated wall controllers.
Slave — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators, and even remote controls.
Primary Controller — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.
Inclusion — is the process of adding new Z-Wave devices into a network.
Exclusion — is the process of removing Z-Wave devices from the network.
Association — is a control relationship between a controlling device and a controlled device.
Wakeup Notification — is a special wireless message issued by a Z-Wave device to announce that is able to communicate.
manual.zwave.eu/backend/make.php?lang=en&sku=GOAEZMNHWD1
Node Information Frame — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.

(c) 2020 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal,
Germany, All rights reserved, www.zwave.eu. The template is maintained by Z-Wave
Europe GmbH. The product content is maintained by Z-Wave Europe
GmbH, Support team, support@zwave.eu. Last update of the product data: 2017-12-27
14:35:13
manual.zwave.eu/backend/make.php?lang=en&sku=GOAEZMNHWD1
26-10-2020

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals