BOGEN WV100 Wall Mount Power Vector Amplifiers User Manual
- June 6, 2024
- BOGEN
Table of Contents
BOGEN WV100 Wall Mount Power Vector Amplifiers User Manual
Notice
Every effort was made to ensure that the information in this guide was
complete and accurate at the time of printing. However, information is subject
to change.
Important Safety Information
WARNING: To Reduce The Risk of Fire Or Electric Shock, Do Not Expose This
Apparatus To Rain Or Moisture.
Always follow these basic safety precautions when installing and using the
unit:
-
Read these instructions.
-
Keep these instructions.
-
Heed all warnings.
-
Follow all instructions.
-
Do not use this apparatus near water.
-
Clean only with dry cloth.
-
DO NOT block any ventilation openings. Install in accor-
dance with the manufacturer’s instructions. -
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
-
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade, or the third prong, are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
-
Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
-
Only use attachments/accessories specified by the manufacturer.
-
Unplug this apparatus during lightning storms or when unused for long periods of time.
-
Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
IMPORTANT
CAUTION: TO PREVENT THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR
BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED
PERSONNEL.
The lightning flash with arrowhead symbol, within an equilateral triangle, is
intended to alert the user to the presence of uninsulated “dangerous voltage”
within the product’s enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Panel Descriptions
Wall-Mount Power Vector Front Panel
-
Input Volume Control
Each of the 8 module bays are controlled by an independent volume control. -
Signal / Clip Indicator
A single two-color LED located above each channel’s volume control indicates the audio activity of that channel’s input. Green indicates signal active at the input; red indicates clipping of the input signal. -
Panel Input Connector
A combination XLR female and 1/4″ stereo phone jack connector provides a panel-mounted input. Parts included, but comes uninstalled. -
Output Limiter Control with Indicator
Control determines maximum amp output level before limiting takes place. Indicator illuminates when limiting takes place. -
Average / Peak Switch
This switch determines whether the LED Output Meter registers the average or peak level of the amplifier’s output. -
LED Output Level Meter
An 11-segment LED output level meter monitors the output level of the power amplifier. -
Tape Out
RCA unbalanced signal level output post bass, treble, and master controls. -
Bass Control
Controls the amount of cut or boost of bass frequencies below 100 Hz. -
Treble Control
Controls the amount of cut or boost of treble frequencies above 10 kHz. -
Master Volume
Control Controls overall level of mixed input signals. -
Power Switch Controls AC power to the amplifier. Illuminates when ON.
Wall-Mount Power Vector Module Bay (Rear)
-
Module Bays
The amplifier has eight module bays, all of which can accommodate input modules, with two bays (bays 7
and 8) that can accommodate either input or output modules. -
Lo-Cut Switch
Slide switch (located in module bay 6) allows roll off of frequencies below 125 Hz. -
Tone Control Bypass Switch
Slide switch (located in module bay 6) allows the effects of the Bass and Treble controls to be bypassed.
Wall-Mount Power Vector Connector Board (Rear)
-
Trans Output / Direct Out Selector
Allows selection of either “TRANS” for transformer-coupled outputs (70V, 25V, and 8-ohm), or “DIR” for direct low-impedance (4-ohm minimum) output. -
Speaker Output Barrier Strip
A terminal barrier strip, with clamping washers, provides connections for speaker loads. -
Mute Control Terminals
Provides access to mute buses for external control and system expansion. -
Bridging Mix Bus
An RCA connector that allows the bridging of Power Vectors together for system expansion. -
Remote Volume Control Terminals
Provides for connection of an RVCP remote volume control panel to control the amplifier’s motorized Master Volume Control.
Installation
Package Contents
- Amplifier
- 2 Cables
- Instruction Manual
- Combined XLR receptacle and phone jack
- 2 Screws (M 3 x 8)
- 6 Screws (M 4 x 8)
Mounting
A surface-mount (model BBS) or flush-mount (model BBF shown below) back box as
well as a WMAD door is required for installation. Refer to the instructions
provided with these items for proper installation. (See Components on Back
Cover.)
WARNING:
To prevent injury, this apparatus must be securely attached to the wall in
accordance with the installation instructions.
Front Panel Input Connector
If desired, a front panel mounted combination female XLR and 1/4″ stereo phone
jack can be installed. A white screened area is provided on the front of the
amplifier, below the connector, to identify the connector’s purpose and
associated input number. Remove the filler cap in the upper left-hand corner
of the front panel and install the combination jack as shown in the figures
below. Either or both of the connector styles on the jack can be wired to any
user-supplied module with included cables. The labeling below the two cable
connectors on the PCB identifies corresponding connectors on the combo jack.
Module Installation
Eight module bays are available to accept Bogen’s new advanced plug-in
input modules. Module bays 7 & 8 can also accommodate Bogen’s new advanced
plug-in output modules, thereby allowing users to customize the amplifier to
suit the needs of the installation.
(Note: The bays will not accept Bogen’s older style D-Series plug-in modules.)
Before installing a module, read the instructions included with the module and
make the desired jumper setting changes.
The modules are installed by simply sliding them along the card guides inside
the module bays until the faceplate firmly sits against the chassis, then use
the two screws supplied with the module to secure it to the chassis.
CAUTION
DO NOT FORCE MODULES
- Modules should slide in easily.
- Output modules can only be installed in bays 7 & 8. (Output modules will not fit in bays 1-6.)
- Output modules have 8 contacts on each side of the connector.
- Input modules have 6 contacts on each side of the connector.
- Older style Bogen (D-Series) input modules (4-1/2″ in length) are not usable in any Power Vector amp
Output Modules
Functionality
The Wall-Mount Power Vector series of amplifiers accepts Bogen plug-in output
modules, which offer a cost effective and convenient way to add specific
signal processing capability into a system. When an output module is
installed, the mix bus signal is automatically rerouted through the output
module, whose capabilities further process the signal before it enters the
power amplifier section.
Up to 2 output modules can be installed in a Power Vector amplifier using
module bays 7 & 8 (or these bays can accept input modules). When two output
modules are installed, their signal processing effects are cascaded. The mix
bus signal will first pass through the output module in module bay 7 and then
through the output module in bay 8. In some instances, the order in which the
signal processing is applied is important and can be achieved by the module
installation order.
Output modules automatically insert themselves into the signal path between
the mix bus and power amp stage, so no further connections are required beyond
simply inserting the modules. Most Bogen output modules include an unbalanced,
Hi-Z input. This input feeds directly to the amplifier’s mix bus through the
front level control for the particular module bay and is not processed by the
output module directly. The input is included so that the additional input
function of the module bay is not forfeited when an output module is
installed.
Input Modules
Functionality
The Wall-Mount Power Vector series of amplifiers accepts Bogen’s new advanced plug-in input modules, which provide a wide range of input types allowing the amplifier inputs to be custom configured in both type and number for a particular application. Input modules can be installed in any of the 8 module bays and do not have to be installed in any particular bay order. The front panel volume control for that number bay will control the mix level of that input module. In addition to a host of module specific features, each input module has a priority jumper section for creating a priority hierarchy between different inputs installed in the amplifier.
Priorities
The Wall-Mount Power Vector series of amplifiers allows inputs to be
prioritized at four different levels. The Bogen input modules contain
circuitry that can cause their outputs to be muted in response to higher
priority control signals from other input modules. Each input module also
contains circuitry that sends a mute control signal out to other modules when
it becomes active (all input modules become “active” when they receive an
audio input). Active modules may be prevented from sending their audio onto
the mix bus by a higher priority module that is also active.
Input priorities are set through a simple jumper field on the module. It is
also possible not to assign a priority level to an input module. By doing so,
that module will never be muted by another input module in the amplifier. The
unassigned inputs will, however, be muted by the amplifier’s Master Mute
input.
Connections
Speakers
Transformer-Coupled Speaker Connections
Transformer-coupled, constant voltage speaker loads are connected to their
respective load type (i.e., 70V speakers to the 70V terminal, 25V speaker
systems to the 25V terminals) and the COM terminal. Make sure the selector
switch is in the TRANS position. A separate 8-ohm terminal is provided to
drive 8-ohm (low-impedance) speakers through an output transformer tap.
The speaker terminals can accept up to a #10 spade lug and have integral
clamping plates that make wiring easier.
4-Ohm Low-Impedance Speaker Connections
A low-impedance (4Ω) speaker load can be driven directly (without transformer
coupling) by connecting the load to the 4Ω terminal and the GND terminal. Make
sure the selector switch is in the DIR position. Bypassing the output
transformer and driving the speaker load directly provides the advantage of
better bass response. To maximize the power delivered to the speakers, their
combined load impedance should be 4 ohms. Connecting higher load impedances is
electrically acceptable, but the mismatch in load impedance will cause the
speaker load to only receive a portion of the power that the amplifier is
capable of delivering. It is not acceptable to connect low-impedance speakers
to the 70V and 25V outputs.
Typical connections to a 70V transformer-coupled speaker
Typical connections to a low-impedance (non-transformer-coupled) speaker
load
COM and GND Terminals
A shorting jumper typically connects the COM and GND terminals of the
amplifier together. The COM terminal is a common lead from the output
transformer. For the transformer-coupled speaker output to work, one of the
speaker load leads must be connected to this terminal. The GND terminal is a
connection to the system’s electrical ground and used when driving loads in
the Direct Out mode.
Connecting the GND to the COM terminal when using the transformer-coupled
outputs references the transformer output to ground. Disconnecting the GND
terminal from COM allows the transformer output to float electrically. This is
sometimes useful under certain conditions where a ground connection is
undesirable. It is generally a good idea, however, to short the GND to the COM
terminal regardless of output type (Trans or Direct).
Remote Volume Control
These terminals are provided for remote control of the Master Volume control.
This control is motorized, allowing full control over the setting of the
master volume. The Bogen Remote Volume Control Panel (model RVCP) provides a
simple and elegant means of remote control. Shorting the UP terminal with the
C terminal will rotate the Master Volume control in a clockwise direction,
increasing the volume level. Shorting the DN terminal to the C terminal will
cause the Master Volume control to rotate in a counterclockwise direction and
decrease the level of the Master Volume control. The impedance of the shorting
connections must be less than 100 ohms in order to operate the control.
Mute Control
Each priority bus (High, Medium, and Low) can be externally activated. This
allows priority buses of two or more Wall-Mount Power Vector units to be
linked together for system expansion purposes. A particular mute priority can
be externally forced by shorting that priority’s bus terminal to the C
terminal of the Mute Control (the C terminal is the system ground). Forcing
the H priority bus this way will mute all modules except for modules set for
priority level 1 (highest priority). Forcing the M priority bus will mute
modules set for priority levels 3 or 4, but not levels 1 or 2, and forcing the
L priority bus will only mute modules set at priority level 4. See System
Expansion of Power Vector Amplifiers section and illustration.
Bridging Mix Bus
This connector makes the Wall-Mount Power Vector’s mix bus available
externally and allows the connecting of Power Vector units for system
expansion and simple room combining.
This function is bi-directional. Any signal received will be amplified and any
signal sent can be used by another Power Vector amp. The signal levels at the
bridging jack will drop by one-half with two Power Vectors tied together and
by two-thirds with three units tied together. Because of the attenuation of
the bridging signal, due to the signal loading of other Power Vectors, it is
not recommended that more than three units be connected together. See Mute
Control section and the illustration on the next page for additional
information.
System Expansion of Power Vector Amplifiers
Using the bridging RCA connector, it is possible to connect two or more Power
Vector amplifiers. It is not recommended that more than three amplifiers be
bridged together due to bridging loss. When connecting mute control functions,
make certain that the wiring is consistent (H to H, M to M, and so forth). See
illustration below.
Operation
Front Panel Controls & Indicators
Input Volume Controls
Each input module may be individually controlled by its corresponding volume
control knob.
Signal / Clip Indicator
A single LED located above each channel’s volume control indicates the audio
activity of that channel’s input. Green indicates signal is being applied to
the mix bus. Red indicates that the input signal coming from the input module
into the amp is clipping and distorted. This is caused by either an input
signal that is too high or an input module volume control (gain) that is set
too high.
Bass and Treble Controls
The treble control has a cut/boost range of +/- 10 dB at frequencies above 10
kHz and provides a roll off after 20 kHz to reduce gain above the audio range.
The bass control has a cut/boost range of +/- 10 dB at frequencies below 100
Hz.When driving speakers using the direct-coupled output terminals, the bass
filter’s response is constant to 20 Hz. When driving speakers using the
transformer-coupled output terminals, the amplifier automatically changes the
bass filter’s response to a bandpass shape to reduce the level of bass
frequencies below 40 Hz. This filter shape helps to avoid overdriving the
speaker’s coupling transformer with low frequency signals that may cause
noticeable distortion due to magnetic saturation of the transformer’s core.
Master Volume Control
The overall volume level of the amplifier is set by a Master Volume control.
The Master Volume control is motorized and can be controlled by manually
adjusting the knob or by a remotely-mounted control station. Connections and
requirements for the remote control station (optional accessory) are described
in the Connections section, under Remote Volume Control.
Average / Peak Switch & LED Output Meter
The LED Output Meter is an 11-segment meter that registers either the average
or the peak level of the amplifier’s output signal. A red indicator is
provided at the +3 dB level to indicate amplifier clipping. Amber indicators
at the 0 dB and -3 dB levels indicate high amplifier output levels. The
remaining 8 indicators (green) provide an indication of the output signal’s
dynamics. The meter can be set to read either the average output signal level
or the peak output signal levels by using the Average / Peak Switch to the
left of the meter. In is average; out is peak.
Power Switch / Power Indicator
The AC power to the amplifier is controlled by the Power rocker switch, which
illuminates when power is applied.
Output Limiter
The Output Limiter control sets the threshold at which the unit hard limits
the output signal. Once the Limiter’s threshold is exceeded, the output signal
is prevented from increasing any further. With the control set to the Min
position (fully counterclockwise), the Limiter will provide almost no limiting
and is essentially turned off. It will only engage when very large output
levels are produced. As the control is turned clockwise, more limiter function
will be allowed and the output level necessary to engage the Limiter
decreases.
Typically, the Limiter is set to prevent clipping caused by overdriving the
amplifier beyond its maximum output level. This setting is established by
using both the Output Level Meter and the Limiter LED.
First, adjust the amplifier’s output level until the Output Level Meter
registers in the amber region. Then, adjust the Output Limiter control until
the Limiter LED illuminates intermittently. The LED associated with the
Limiter illuminates when the Limiter is engaged. If the output level of the
amplifier exceeds this point, then the Limiter will engage, thereby keeping
the Output Level Meter in the amber region. The Limiter can also be set to
restrict the amplifier’s output level to a desired level below the amplifier’s
maximum level to provide a means of limiting the system’s volume level. In
this case, the amplifier is driven to the desired output level and then the
Limiter control is adjusted so that it begins to engage. In general, input and
master controls should be set so that the Limiter engages as little as
possible.
Rear Panel Controls
Trans Output / Direct Out Selector Switch
A large slide switch next to the amplifier’s output barrier strip determines
transformer-coupled or direct output operation. The setting of
this switch controls which amplifier output terminals are active and
what type of filter shape will be used for the bass control. See the
Connections section for more information about the load selector
switch.
Other Controls (Located In Module Bay 6)
Tone Control Bypass Switch
A slide switch that can bypass the effects of the Bass and Treble controls is
located on the back plane of module bay 6. It is sometimes desirable to bypass
the tone controls when other forms of system equalization are used. A
screwdriver can be used to set the switch. The switch must be set before a
module is installed in this bay.
Lo-Cut Switch
The Power Vector Amplifier provides a lo-cut filter that rolls off frequencies
below 125 Hz. The slide switch for this function is located on the back plane
of module bay 6. A screwdriver can be used to set the switch. The switch must
be set before a module is installed in this bay
Block Diagram
Specifications
-
Power Output (RMS): WV100: 100W (140W Typical, @1 kHz/0.1%/4Ω) WV150: 150W (200W Typical, @1 kHz/0.1%/4Ω)
WV250: 250W (340W Typical, @1 kHz/0.1%/4Ω) -
Frequency Response
Transformer: 45 Hz to 20 kHz; 0/-2 dB @ FRP
Direct: 20 Hz to 20 kHz; 0/-1 dB @ FRP -
Distortion
Transformer: 0.5% THD+N, Maximum, Full-rated bandwidth @ FRP
Direct: 0.1% THD+N, Maximum, Full-rated bandwidth @ FRP -
Signal-to-Noise
Fundamental: -94 dB
With Aux Module: -70 dB
With Mic Module: -60 dB
With Tel Module: -70 dB -
Tone Controls
Bass Frequency: 100 Hz (+/- 10 dB minimum)
Treble Frequency: 10 kHz (+/- 10 dB minimum)
Low Cut Frequency: 125 Hz @ -6 dB/octave
Sensitivity: 0.4V (at backplane connector)
Output Regulation: 2 dB or better no load to full load -
Output Impedance
Transformer-Coupled: 70V, 25V, 8 ohms; balanced or unbalanced
Direct Coupled: 4 ohms unbalanced -
Thermal Emissions: WV100: 495.2 BTU/hr.
WV150: 696.7 BTU/hr.
WV250: 911.9 BTU/hr. -
Tape Out
Output Level: 4 VRMS @ FRP
Output Impedance: 50 ohms maximum
Protection: Thermal, short-circuit, and overload (auto reset)
Line Fusing: Resettable circuit breaker
Cooling: Thermally controlled 3-speed fan
Power Consumption: WV100: 2.0A @ 120V AC, 60 Hz
WV150: 3.5A @ 120V AC, 60 Hz
WV250: 5.5A @ 120V AC, 60 Hz
Approvals: Listed to UL Standard 60065 for U.S. and Canada
Dimensions: WV (all models): 14-1/8″ W x 21″ H
BBF: 14-1/2″ W x 24-3/4″ H x 3-7/8″ D
BBS: 16-1/4″ W x 26-3/4″ H x 3-7/8″ D
WMAD: 16-1/4″ W x 26-3/4″ H x 1″ D
Product Wei g ht: WV100: 27 lb.
WV150: 29 lb.
WV250: 28 lb.
BBF: 12 lb.
BBS: 16 lb.
WMAD: 9 lb.
Troubleshooting
PROBLEM | CONDMON | CAUSE |
---|---|---|
NO SOUND | Power Indicator LED is off. |
- Amplifier not plugged in
- AC outlet dead.
- Power switch off
- Circuit breaker tripped.
Power Indicator LED is red.
Input Signal I Chp LEO is off|
- No signal from source.
- Module not installed correctly.
Power Indicator LED is red. Input Signal / Clip LED is green LED Output Meter
nff.
o|
- Master or input channel volume control turned down.
- Rear panel master mute terminal shorted.
Power Indicator LED is red. Input Signal /Clip LED is green LED Output Meter Is operating|
- Speaker connections on amplifier are incorrect.
- Trans I Direct Out selector not set correctly.
- Poor I broken speaker wiring.
- Defective speakers.
DISTORTED SOUND| Power Indicator LED is red.
Input Signal / Clip LED is green. Volume Controls are turned up and shows
little activity.
Unit is extremely hot.|
- Partial short on the output.
Power Indicator LED a red. Input Signal / Clip LED is green. LED Output Meter is not in red|
- &gnat from source is already distorted.
- Poor speaker connections.
- Trans-Out load on wrong tap.
- alss control boosted too much.
Power Indicator LED is red.
Input Signal / Clip LED is red
not in red. LED Output Meter is|
- Input signal level to module too high (should cause red clip LED).
- Input module gain too high (rf available).
- Input module being overdriven by a high input signal.
Power Indicator LED is red. Input Signal / Clip LED is green LED Output Meter in red|
- Input volume controls set too high.
- Input master volume control set too high.
POOR LOW FREQ. RESPONSE (NO SASS)| Power Indicator LED is red. Input / Signal Clip LED is green. LED Output Meter not in red.|
- Lo-cut switch is set to ON.
- Speakers wired out of phase.
- Check module bass control setting (if available).
- Check bass control setting
- Note. Transformer-coupled speakers have less bass response.
NOISE/NUM| Power Indicator LED is red. Volume controls are in normal. operational position.|
- Poor electrical connections at input.
- Input cable routed near AC cables, power transformer. or other EMI radiating devices.
- Electrically noisy devices operating on the same AC circuit.
- Poor equipment grounding.
- Ensure that OliACsofety grounds ore connected
- Make sure that aV components in God° chain ore tied to the some ground.
Limited Warranty; Exclusion of Certain Damages
The Bogen Power Vector Amplifiers are warranted to be free from defects in
material and workmanship for three (3) years from the date of sale to the
original purchaser. Any part of the product covered by this warranty that,
with normal installation and use, becomes defective (as confirmed by Bogen
upon inspection) during the applicable warranty period, will be repaired or
replaced by Bogen, at Bogen’s option, provided the product is shipped insured
and prepaid to: Bogen Factory Service Department, 50 Spring Street, Ramsey, NJ
07446, USA. Repaired or replacement product will be returned to you freight
prepaid. This warranty does not extend to any of our products that have been
subjected to abuse, misuse, improper storage, neglect, accident, improper
installation or have been modified or repaired or altered in any manner
whatsoever, or where the serial number or date code has been removed or
defaced.
THE FOREGOING LIMITED WARRANTY IS BOGEN’S SOLE AND EXCLUSIVE WARRANTY AND THE
PURCHASER’S SOLE AND EXCLUSIVE REMEDY. BOGEN MAKES NO OTHER WARRANTIES OF ANY
KIND, EITHER EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE
MAXIMUM EXTENT ALLOWABLE BY LAW. Bogen’s liability arising out of the
manufacture, sale or supplying of products or their use or disposition,
whether based upon warranty, contract, tort or otherwise, shall be limited to
the price of the product.
IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL
DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS, LOSS OF DATA OR LOSS
OF USE DAMAGES) ARISING OUT OF THE MANUFACTURE, SALE OR SUPPLYING OF PRODUCTS,
EVEN IF BOGEN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES.
Some States do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to
you. This warranty gives you specific legal rights, and you may also have
other rights which vary from State to State.
Products that are out of warranty will also be repaired by the Bogen Factory
Service Department – same address as above or call
201-934-8500.
The parts and labor involved in these repairs are warranted for 90 days when
repaired by the Bogen Factory Service Department. All shipping charges in
addition to parts and labor charges will be at the owner’s expense.
All returns require a Return Authorization number. For most efficient warranty
or repair service, please include a description of the failure.
Accessories/Components
Mounting Components
-
One of the following two back boxes are required for assembly.
BBF – Flush-Mount Back Box
-
Mounting kit for installing amplifier flush to a wall
BBS – Surface-Mount Back Box -
Mounting kit for installing amplifier to the surface of a wall
-
-
The WMAD is required for assembly.
WMAD – Front Cover / Door- Prevents tampering with system settings
- Simple installation
Accessories
The following item is an optional accessory
RVCP – Remote Volume Control Panel
- Push-button operation of motorized master volume control
- Fits in standard single gang electrical box
- Decora style cover plate
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>