KLARK TEKNIK 2-Channel Active DI Box DN200 User Guide

June 6, 2024
Klark Teknik

KLARK TEKNIK 2-Channel Active DI Box DN200

Controls


  1. STEREO INPUT – Connect a line-level audio source via stereo 1/8″ TRS cable. Ensure that the L/R INPUTS and LINK THRU jacks are disconnected when using the STEREO INPUT jack.

  2. PAD – Press to reduce the input signal by 20 dB for use with hot signals.

  3. EARTH – Press to separate the input and output grounds, potentially eliminating earth/ground loops between equipment on different mains supplies.

  4. L/R INPUT – Connect either balanced or unbalanced XLR or 1/4″ cables. Ensure that the 1/8″ STEREO INPUT jack is disconnected when using these inputs.

  5. 48 V LED – Lights when the unit receives sufficient phantom power. Note that the DN200 must be powered to operate correctly.
    Important: Although the DN200 will function as a mono device when only one channel is connected, both channels should be powered to use stereo, split, or sum modes.

  6. SUM – When engaged, the left and right inputs are summed and fed to the left and right outputs. Note that phantom power must be delivered to both output connections for dual-output operation.

  7. SPLIT – When engaged, the left input is fed to the left and right outputs. Note that phantom power must be delivered to both output connections for dual-output operation.

  8. L/R OUTPUT – Send the signals to a mixer or recording interface via balanced XLR cables. Note that the connected device must be able to provide +48 V phantom power to these connectors.

  9. LINK THRU – Send the signals to an alternate source via balanced or unbalanced 1/4″ cables. Ensure that the 1/8″ STEREO INPUT jack is disconnected when using these outputs.

Specifications

System

Connectors| 2 x combo XLR, 2x¼” TRS link jacks,1/s” stereo TRS jack
Impedance| 1 MO {combo &link jacksbalanced), 20kO {combo XLR only), 500 kO (1/s” stereo TRS jack unbalanced)
Max input level| 28 dBu combo XLR and TRS link jacks {pad enabled), 21 dBu1/s” TRS jack(pad enabled)
Attenuator| 20 dB pad
System
Connectors| 2 x 3-pinXLR
Impedance| 500
Max output level| 13 dBu with10kO load,10 dBu with600 0 load
Min load| 6000
System
Noise| -103 dBu, 22 Hz to 22kHz unweighted, with input terminatedby 10kO resistor
Frequency response| 20Hz to 20kHz, +1dB,10 kΩ load
Distortion (THD + N)| Typically <0.005%@ 1 kHz,+ 10 dBu
Crosstalk| <100 dB@ 1 kHz, inputs terminated
Power Requirement|
Voltage| + 48V phantom
Current consumption| <10mA per channel
Physical
Dimensions| 118 x 63 x 142 mm (4.7 x 2.5 x 5.6″)
Weight| 0.65 kg (1.43 lbs)

LEGAL DISCLAIMER

Music Tribe accepts no liability for any loss which may be suffered by any person who relies either wholly or in part upon any description, photograph, or statement contained herein. Technical specifications, appearances and other information are subject to change without notice. All trademarks are the property of their respective owners. Midas, Klark Teknik, Lab Gruppen, Lake, Tannoy, Turbosound, TC Electronic, TC Helicon, Behringer, Bugera, Oberheim, Auratone, Aston Microphones, and Coolaudio are trademarks or registered trademarks of Music Tribe Global Brands Ltd. © Music Tribe Global Brands Ltd. 2021 All rights reserved.

LIMITED WARRANTY

For the applicable warranty terms and conditions and additional information regarding Music Tribe’s Limited Warranty, please see complete details online at www.musictribe.com/warranty

FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE INFORMATION

Klark Teknik

DN200


Responsible Party Name: Music Tribe Commercial NV Inc.
Address: 5270 Procyon Street, Las Vegas NV 89118, United States
Phone Number: +1 702 800 8290

DN200

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.

Important information:
Changes or modifications to the equipment not expressly approved by Music Tribe can void the user’s authority to use the equipment.

Hereby, Music Tribe declares that this product is in compliance with
Directive 2014/30/EU, Directive 2011/65/EU and Amendment 2015/863/
EU, Directive 2012/19/EU, Regulation 519/2012 REACH SVHC and Directive 1907/2006/EC.

Full text of EU DoC is available at https://community.musictribe.com/
EU Representative: Music Tribe Brands DK A/S
Address: Ib Spang Olsens Gade 17, DK – 8200 Aarhus N, Denmark

www.musictribe.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Klark Teknik User Manuals

Related Manuals