Vader LCPRO Profile High Power LED Moving Head User Manual
- June 9, 2024
- Vader
Table of Contents
Vader LCPRO Profile High Power LED Moving Head
Unpacking
Thank you for choosing Vader Profile.For your own safety,please read this mannual before installing the device.This manual covers the important information on installation and applications.Please operate the fixture with following instructions. Meanwhile,please keep this manual well for future needs. The Vader Profile is made of new type of high-temperature strength of engineer plastics and cast aluminum casing with nice outlook.The fixture is designed and manufactured strictly following CE standards,complying with international standard DMX 512 PROTOCOL.It`s available independently controlled and linkable with each other for cooperation.And it is applicable for large-scalable live-performance, theaters,studio, nightclubs and disco. Vader Profile adopts powerful 580W LED which features high brightness and stability.Please carefully unpack it when you receive the fixture and check whether it is damaged during the transportation.And please check whether the following items are including inside the box:
- Moving head light ————-One
- Omega—————————Two
- Power Cable——————–One
- User Manual——————–One
Safety instructions
CAUTION
Be careful with your operations.With a dangerous voltage you can suffer a
dangerous electric shock whentouching wires
This device has left the factory in perfect condition. In order to maintain this condition to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual. If the device has been exposed to temperature change due to environmental changes,do not switch it on immediately. The arising condensation could damage the device.Leave the device switched off until has reached room temperature.
Operate on instruction
- The moving head is for beam spot wash effect for onsite decoration purpose.
- Don’t turn on the fixture if it’s been through severe temperature difference like after transportation,because it might damage the light due to the environment changes.
- So make sure to operate the fixture until it is normal temperature.
- This light should be keep away from strong shaking during any transportation or movement.
- Don’t pull up the light by only the head, or it might cause damages to the mechanical parts.
- Don’t expose the fixture in overheat, moisture or environment with too much dust when installing it.
- And don’t lay any power cables on floor. Or it might cause electrionic shock to the people.
- Make sure the installation place is in good safety condition before installing the fixture.
- Make sure to put the safety chain and check whether the screws are screwed properly when installing the fixture.
- Make sure the lens are in good condition. It’s recommended to replace the units if there are any damages or severe scratch.
- Make sure the fixture is operated by qualified person who knows the fixture before using.
- Keep the original packages if any second shipment is needed.
- Don’t try to change the fixtures without any instruction by the manufacturer or the appointe drepairing agencies.
- It is no in warranty range if there are malfunctions from not following the user manual to operate or any illegal operation, like shock short circuit, electronic shock, lamp broke, etc.
Mounting and Installation
Cautions
For added protection mount the fixture in areas outside walking paths,seating areas,or in area were the fixture might be reached by unauthorized personnel. Before mounting the fixture to any surface,make sure that the installation area can hold a minimum point load of 10 times the device’s weight. Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable. Never stand directly below the device when mounting,removing,or serving the fixture from a ceiling,or set on a flat level surface(see illustration below).Be sure his fixture is kept at least 0.5m(1.5ft)away from any flammable materials (decoration etc.) Always use and install the supplied safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp fails. Mounting points: Overhead mounting requires extensive experience, including amongst others calculating working load limits,a fine knowledge of the installation material being used,and periodic safety inspection of all installation material and the fixture. If you lack these qualifications,do not attempt the installation yourself.Improper installation can result in bodily injury. Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet Clamp mounting: The Vader Profile provides a unique mounting bracket assembly that integrates the bottom of the base,the included OMEGE BRACKET,and the safety cable rigging point in one unit(See the illustration below).When mounting this fixture to truss be sure to secure an appropriately rated clamp clamp to the included omega bracelet using a M10 screw fitted through thecenter hole of the OMEGE BRACKET.
- OMEGA-HOLDERS
- CLAMP
- SAFETY-ROPE
- QUICK LOCK FASTENC
DMX 512 Control connection
Connect the provice XLR cable to the female 3 pin XLR Output of your control and the other side to the male 3-pin XLR input of the moving head,You can chain multiple Movng head together through serial linking.The cable needed should be two core, screened canle with XLR input and output connectors.Please refre to the diagram below.DMX-512 Connection with DMX terminator.
For installations where the DMX cable has to run a long distance or is in an electrically noisy enviromentsuch as in a disco,it is recommended to use a DMX terminator. This helps in preventing corruption of the digital control singal by electrical noisy. The DMX terminator is simply an XLR plug with a 120 resistor connected between pins 2and 3,which is then plugged into the output XLR Socket of the last fixture in the chain. Please see illustrations
The control Display
Top menu,present the current opertion
Press the
Menu for Control Display
Note
- Above all projects to the actual lighting shall prevail, no notice if there is further modification;
- The programming function provides only a very limited operation, in the case of no control units to use. Generally do not recommend the use of manual programming;
- In the absence of the DMX512 signal, only need to set up first items, namely the address code can be used lamps.
29/40 Control Channels
Specification
OPTICS
- Light Source :580W White LED Module
- Lumen: 20,500
- Lifetime: 50000 Hours
- Color temperature:7000K
- CRI: at least 90, CT 6500K
MOVEMENT
- Pan movement:540°(16 bit)
- Tilt movement :270°(16 bit)
- Automatic reset function
COLORS
- Linear CMY+CTO
- Colors wheel:1+6colors
GOBOS
- Gobos wheel:1pcs rotation Gobo wheel +1pcs fixed Gobo wheel 6 changeable Gobos,be installed glass pattern and a metal piece The bidirectional variable rotation,index functions,Bi-direction changeable speed shake effect,changeable speed and flow effect
- Animation wheel(interchangeable with fixed gobo wheel)
FEATURE
- Prism:2 pcs rotating prism(4 facet and 4 facet linear)
- Iris: Linear adjustable with macro
- Soft lighting: 1pcs independent scrim
- Focus: DMX 512 linear focus
- Dimmer: 0-100% linear dimmer
- Strobe: Electronic strobe,0.3-20Times/SEC
- Zoom: Smooth and fast speed
- Angle:6.5°-42°linear adjustment
- Prism angel can option
- Control mode: DMX512,Protocols RDM, Wireless and Art-Net
- Standard mode 35 channels, Sound control mode, Stand-alone, Self-inspection mode
FRAMING SYSTEM
- Motorized framing system with 4 focal planes
- 4 Blades that move separately
- Smooth, flexible blade movements at variable speed
- Framing system indexable 180 degrees
OTHER FUNCTION
- DMX Software update
- Show software version number
- Intelligent control of wind speed
- Display lamps and lanterns use time
- 100% brightness without stroboscopic problem
- Manual programming function
- Manual fine calibration function
- DMX and RDM data in/out,artnet,wireless
POWER
- Input voltage:220V~240V AC 50/60Hz
- Rate power:800W@220V
HOUSING
- Intellectual property rights of appearance and structure design
- Environmentally friendly flame retardant materials
- High temperature resistant engineering plastics
IP GRADE
- IP:20
DIMENSION AND WEIGHT
- Carton size:770470540MM
- Flight case size(2in1):940X470X870
Maintenance Cleaning
The following points have to be considered during the inspection
- All screw for installing the devices or parts of the device have to be tightly connnected and must be corroded.
- There must not any deformations on the housing,color lenses,fixations and installation spots(Ceiling, suspension,trussing)
- Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances.
- The electric power supply cables must not show any damage,material fatigue or sediments
Futher instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed.
CAUTION
Disconnct from mains before starting maintenance operation.
In order to male the lights in good condition and extend the life time, we suggest a regular clearning to the lights.
- Clean the inside and outside lens each week to avoid the weakness of the lights due to accumulation of dust.
- Clean the fan each week.
- A detail electric check by approved electrical engineer each three month, make sure the circuit contacts are good condition, prevent the poor contact of circuit from overheating.
We recommend a frequent cleaning of the device.Please use a mosit,lint-free cloth.Never use alcohol or solvents. There are no seviceable parts inside the device.Please refer to the instructions under Installation instructions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>