Fieldpiece DR82 Infrared (IR) Refrigerant Leak Detector User Manual

June 6, 2024
Fieldpiece

Fieldpiece DR82 Infrared (IR) Refrigerant Leak Detector User Manual
Fieldpiece DR82 Infrared \(IR\) Refrigerant Leak
Detector

Description

Compact and rugged, the DR82 Infrared Refrigerant Leak Detector helps you find leaks fast in the field. The 10 year infrared (IR) sensor detects all HFC, HCFC, CFC, HFO, and blends.

Multiple indicators and sensitivity 20x higher than soap bubbles make it easy to track down even the smallest leaks in various environments. A red LED flashes at the tip so you can keep your eyes on the target. The large bars on the backlit LCD are easy to see in bright sunlight or low light, and the numerical value provides an extra digit of resolution.

Unlike conventional leak detectors, you have full control with both an automatic (AZERO) and manual (MZERO) zero mode.

The large Li-ion rechargable battery provides over 10 hours of continuous operation and is convenient to charge via USB-C. Replaceable tips filter out water and dust while getting into tight spots. All wrapped up in a ruggedized IP54 housing, it’s built for the field.

WARNINGS

Inhalation of high concentrations of refrigerant vapor can block oxygen to the brain causing injury or death. Do not use this device in a combustible gas atmosphere or with A3 refrigerants such as R-290, propane or R-600, isobutane. Do not block exhaust port or device or will not function properly.

Quick Start

  1. Move to a refrigerant-free environment and hold until your DR82 powers on.
  2. Allow warm-up (calibration) to complete.
  3. Begin searching for the leak source. Move the tip slowly (~3 inches/sec) and as closely as possible to the suspected refrigerant line.
  4. Search until refrigerant gas is detected. Red light flashes, audible alarm triggers, and the display indicates the relative gas concentration.
  5. Confirm leak source. Move tip away from alarm location for a few seconds to clear the sensor. Return tip back to suspected leak, looking for the highest value.

Maintenance

CLEANING: Clean the exterior with a damp cloth. Do not use detergents or solvents.
BATTERY CHARGING: Recharge the internal battery as needed using the USB-C cable. In addition to the AC plug, most generic USB ports supply enough power to charge. The long life Li-ion rechargable battery is permanently installed. To maximize battery life, minimize time spent at 100% full or 0% full.
FILTER REPLACEMENT: The hydrophobic filter is built into the replaceable tip and should be replaced periodically to maximize sensor life and performance. Five filtered tips (RFT6) are included. Unscrew the tip to remove.
FILTER REPLACEMENT

Functionality Test

Use a refrigerant tank and a cap to check if your DR82 is detecting refrigerant properly.

  1. Tightly cap a refrigerant tank port to seal it.
    Functionality Test

  2. Open valve to coat the inside of the cap, then close the valve.
    Functionality Test Functionality
Test

  3. With DR82 set to high sensitivity (H), remove the cap and wave the tip over the cap. You should see a very large leak size of approximately “99” and a full bar graph. If not, the filtered tip may need to be replaced.
    Functionality Test

Operation

Power
Press >1 second to toggle power

Backlight
Press to toggle the blue backlight.

Zero Modes (AZERO/MZERO)
DR82 starts up in automatic zero mode (AZERO) which sets a new zero point every 4-5 seconds, indicated by a double beep.
Moving closer to the leak source will show the relative increase in concentration, triggering the alarm. Conversely, stopping at or moving away from the leak source will not trigger a response.
Press MANUAL/AUTO >1 second to toggle manual zero mode (MZERO). DR82 does not zero automatically while MZERO is displayed and will continue to alarm and display the relative leak size.

Zero Set
In manual zero mode (MZERO), press ZERO to initiate a 10 second calibration, during which “Zeroing” is displayed. For best performance, remain stationary until calibration finishes.

Operation Instructions

Numerical Leak Size Indicator with Bar Graph
The number is the relative concentration of refrigerant gas (0-99 units). The bar graph shows the same measurement in steps of 10 units for easy monitoring. The higher the number, the higher the concentration of gas being measured and the closer you are to the exact leak location.

Maximum Mode
Press MAX ON/OFF >1 second to toggle max mode. When max mode is on, the highest leak size detected is continually recorded.
The recorded max is cleared when the sensitivity is changed or if manually zeroed.

Sensitivity (H/M/L/T)
DR82 starts up in high sensitivity (H) which is recommended for most situations. When leaks are difficult to pinpoint due to excess triggering or sensor saturation, press SENSITIVITY to cycle to another sensitivity (Medium/Low/Turbo). Turbo is extremely sensitive, and may false trigger from abrupt motion or small changes in gas content.

Mute ( )
Press ZERO and SENSITIVITY simultaneously to toggle the speaker.

Red Leak Indicator LED
In most situations, the red LED at the tip is easier to monitor than the display. Because the blink rate increases as the relative concentration increases, many leaks can be found without ever viewing the display.

LEAK SOURCE
LEAK SOURCE

More HVACR Products from Fieldpiece

  • Vacuum Pumps
    Products Fieldpiece

  • Digital Manifolds
    Products Fieldpiece

  • Job Link® System Clamp Meters
    Products Fieldpiece

  • Job Link® System Probes
    Products Fieldpiece

  • Refrigerant Recovery Machines
    Products Fieldpiece

Specifications

Sensor Type: Infrared (IR)
Sensor Life: 10 years typical
Sensitivity Levels: High, medium, low, turbo (selectable)
Maximum Sensitivity: 0.03 oz/yr (1g/a), stationary; 0.1 oz/yr (3g/a), in motion
Detection Feedback: Red tip LED, LCD bar graph, LCD digits, beeper
Refrigerants: HFC, HCFC, CFC, HFOs, and blends
Response Time: <1 seconds typical
Recovery Time: <5 seconds typical
Battery Type: 3.7 VDC (nominal) 2600mAh, non-replaceable
Charge Time: 6 hours typical with included charger.
Battery Life: 10 hours typical, backlight off
Auto Power Off: 10 minutes without detection or button press
Operating Environment: 32°F to 104°F (0°C to 40°C); < 75% RH (non- condensing)
Storage Temperature: -4°F to 140°F (-20°C to 60°C); < 80% RH Weight: 14 oz (400g)
Water Resistance: Designed to IP54
US Patent: www.fieldpiece.com/patents

What’s Included

DR82 Infrared Refrigerant Leak Detector
Blow Molded Carrying Case (ABM2)
AC Charger and USB-C Cable (RCA3)
5 x Filter Tips and Gaskets (RFT6)
Operator’s Manual
1 Year Limited Warranty

Limited Warranty

This leak detector is warranted against defects in material and workmanship for one year from date of purchase from an authorized Fieldpiece dealer. Fieldpiece will replace or repair the defective unit, at its option, subject to verification of the defect.

This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument.

Any implied warranties arising from the sale of a Fieldpiece product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. Fieldpiece shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim of such damage, expenses, or economic loss.

State laws vary. The above limitations or exclusions may not apply to you.

Obtaining Service
For international customers, warranty for products purchased outside of the U.S. should be handled through local distributors. Visit our website to find your local distributor.

© Fieldpiece Instruments, Inc 2021; v01

Certifications and Compliance

EN 14624

Regulatory Compliance Mark

Restriction of Hazardous Substances Compliant

Waste Electrical and Electronic Equipment

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Fieldpiece User Manuals

Related Manuals