PHOTONTEK X465W Pro Full Spectrum LED Lighting Owner’s Manual
- June 6, 2024
- PHOTONTEK
Table of Contents
X 4][65W PRO
PHONTONTEK FULL – SPECTRUM LED
Manual
INTRODUCTION
Thank you for purchasing the PhotonTek X 465W Pro linear multi-light bar LED fixture. This manual describes how to install and use the PhotonTek fixture; please read this manual thoroughly before attempting to install or operate any PhotonTek X Series system
PRODUCT DESCRIPTION
The PhotonTek X 465W Pro LED is an electronic horticultural LED fixture using a linear array design with five LED light bars. The PhotonTek X 465W Pro is a highly efficient high-intensity full-cycle grow lighting solution for commercial horticulture cultivation. The PhotonTek X 465W Pro has the power and flexibility to scale from vegetative growth to higher light intensities in bloom. In this manual, the Photontek X 465W Pro LED will be referred to as: “the LED fixture”.
PRODUCT INFORMATION AND SPECIFICATIONS
3.1 General Product Information
PRODUCT NAME | Photontek X 465W Pro LED |
---|---|
MANUFACTURER | PhotonTek Horticultural Lighting |
PRODUCT CODE | PTEKLED019 |
EAN | 5.06E+12 |
PLUG TYPE | NEMA 5-15P – 120V mains supply |
Fig1. Fixture dimensions
3.3 Specta
3.4 Light distribution curve
Fig3. Light distribution plot.
3.5 Environment
The LED fixture is intended to be used in climate-controlled grow rooms and
indoor farms. The product may be used in damp environments but may not be used
in wet environments or outdoors. The product will operate in ambient
temperatures from -20°C to 40°C but will function at an optimal level between
20°C to 30°C. The product will operate in 20% — 90% humidity, non-condensing.
3.6 Legal
This product is FCC, IC, CSA & CE certified compliant with LVD and EMC
directive test standards..
SAFETY RECOMMENDATIONS AND WARNINGS
WARNING! Carefully read the warnings below before using or working with the product!
- Always adhere to the local rules and regulations when installing or using the LED fixture.
- Do not open or disassemble the LED fixture as it contains no serviceable parts inside. Opening or modifying the LED fixture can be dangerous and will void the warranty.
- Do not use the LED fixture when either the LED fixture or its power cord is damaged. Replace the power cord with the correctly rated cord only.
- Modifications to the cabling can lead to unwanted electromagnetic effects which may make the product not comply with legal requirements.
- Do not expose the LED fixture to Condensing humidity, heavy mist, or direct spray; Ambient temperatures outside the specified range; Dust and contamination; Direct sunlight during use or HID light that may heat up the driver.
- Always disconnect the LED fixture from the mains before performing any maintenance.
- Always allow for a cool-down period of at least 20-30 minutes before touching the LED light bars. Touching the LED bars when the fixture is lit or immediately after may result in burns!
- Natural convection removes heat away from the heatsink. In order for the system to properly cool itself, at least 5cm of space is required between the fixture and the roof of your grow area.
- Do not use abrasive materials or aggressive cleaning agents to clean the LED fixture as this may damage the secondary optics. Instead, use a clean dry fabric/cloth.
- Do not use the LED fixture near flammable, explosive, or reactive substances. The LED fixture can reach temperatures of 40°C.
- Do not use sulfur vaporizers or water misters.
- The installation and use of the LED fixture are the responsibility of the end-user. Incorrect use or installation can lead to failure and damage to the LED fixture. Damage to the LED fixture and electronic circuitry as a result of incorrect installation and use revokes the warranty.
CONTENTS
1X DIMMING CONTROLLER 0 -10V
Connects to SIGNAL IN connector on Frame B
Fig4. Fixture Componnents
6 1X DRIVER 0/P CABLE
7 1X DIMMING CABLE
- 1 X 120V POWER SUPPLY CORD
- 2 X METAL CABLE HANGERS
- 1X MANUAL
INSTALLATION
WARNING Mounting and installing the LED fixture must be in accordance
with the applicable local laws and regulations.
WARNING The installer is responsible for correct and safe installation.
WARNING Ensure the local cabling can support the voltage and current
requirements of the LED fixture.
WARNING Avoid coiled cords and keep mains leads separated to help prevent
electromagnetic interference.
WARNING Do not connect or disconnect the LED fixture under load.
6.1 Fixture assembly & installation
Note the direction when installing; the driver fixing bracket is on top when the fixture is hung. Press the button on the frame push-click connector to connect and ensure the button pops up in the hole socket to lock.
6.1.1 Assemble the frame
Note the direction when installing; the driver tray is on top when the fixture is hung.
6.1.2 Connect the driver
Using PhotonTek 5m LED driver extension cords (sold separately), the driver can be positioned remotely for greater flexibility.
6.1.3 Connect the LED light bars
6.2 Replacing and changing light bars
Individual 93W lightbars are available to purchase as replacements or with
different spectral ratios to adjust fixture spectral output.
The X 465W Pro fixture’s modular design has an intelligent LED driver which
can autosensing and decrease or increase power to match the amount of 93W
light bars installed on the fixture.
WARNING At least one light bar must be installed in the fixture before
switching on.
6.3 Installing the fixture
WARNING Mount the system to something that can hold the weight of the
LED fixture.
Ensure all light bars are installed correctly and are secure. Carefully turn
the fixture over and attach the metal cable hangers to the mounting hooks.
Hang the fixture in the required position and height. For optimal performance;
position fixture 30 – 50cm above the plant canopy. Ensure the fixture is hung
horizontally.
6.4 Connecting the Manual Dimmer Control
The dimmer control is connected to the Dimming IN connector on the fixture.
This enables light intensity (PPF level) to be adjusted according to
requirements. The LED fixture light intensity can be adjusted without changing
spectral power distribution or losing efficiency.
6.5 Connecting Fixtures in series for External Control
For detailed instructions please refer to the PhotonTek Digital Lighting
Controller manual.
The X 465W Pro uses a 0-10y signal protocol for control. Position and hang
each fixture appropriately.
- Connect controller output signal wire to fixture 1 SIGNAL in the connector. Connect a signal wire from fixture 1 SIGNAL OUT connector to fixture 2 SIGNAL IN connector.
- Continue to connect fixtures in series for up to 100 fixtures per controller, see figure below.
6.6 Connecting the LED fixture to the mains
WARNING Make sure mains power is switched off.
WARNING Ensure the power supply cord is not coiled and does not touch any
hot surfaces.
WARNING Connect the cabling according to local rules, safety regulations,
and electrical code.
WARNING Ensure external switching gear can cope with the inrush current
of the LED fixture. Always use a double pole contactor suitable for switching
a capacitive load. Never use household timers to switch the LED fixture!
WARNING Ensure power cord rating matches mains supply voltage.
- The LED fixture is supplied with a 120V power cord for a 120V power supply. 240V and 277V power cords are not included and must be purchased separately.
- Select the correctly rated cord for your mains power supply and connect the driver power input socket to the switching gear/power supply.
- Switch on mains power. do not connect or disconnect the LED fixture under load.
PRECAUTIONS WHEN USING THE LED FIXTURE
WARNING Always ensure at least one light bar is connected to the fixture
before switching on. The X 465W Pro has an intelligent LED driver which will
increase or decrease power to match the number of light bars connected to the
system.
Always wait 20 — 30 minutes for the LED light bars to cool down.
INSPECTION, MAINTENANCE, AND REPAIR
WARNING Disconnect the LED fixture from the mains before performing any
maintenance or repairs.
WARNING Do not connect or disconnect the LED fixture under load
WARNING Do not open or disassemble the LED fixture, it contains no
serviceable parts inside. Opening the LED fixture can be dangerous and will
void the warranty. or Always wait 20 — 30 minutes for the LED light bars to
cool down.
WARNING Do not clean the LED fixture with detergents, abrasives, or other
aggressive substances.
Regularly check the LED fixture for dust or dirt build-up. Clean if necessary.
Contamination may cause overheating and decreased performance.
• Clean the outside of the LED fixture using a dry or damp cloth.
• Regularly check the cords of the LED fixture to ensure it is undamaged.
STORAGE AND DISPOSAL
Store the LED fixture in a dry and clean environment, with an ambient
temperature of -25°C to 55°C. The product must not be discarded as unsorted
municipal waste but must be collected separately for the purpose of treatment,
recovery, and environmentally sound disposal.
WARRANTY
PhotonTek warrants the mechanical and electronic components of their product
to be free of defects in material and workmanship if used under normal
operating conditions for a period of five (5) years from the original date of
purchase. If the product shows any defects within this period and that defect
is not due to user error or improper use PhotonTek shall, at its discretion,
either replace or repair the product using suitable new or reconditioned
products or parts. In case PhotonTek decides to replace the entire product,
this limited warranty shall apply to the replacement product for the remaining
initial warranty period, i.e. five (5) years from the date of purchase of the
original product. For service; return the product to your shop with the
original sales receipt.