PHOTONTEK XT 1000W CO2 Pro Linear Multi-Light Bar LED Fixture User Manual
- June 12, 2024
- PHOTONTEK
Table of Contents
- INTRODUCTION
- PRODUCT DESCRIPTION
- PRODUCT INFORMATION AND SPECIFICATIONS
- SAFETY RECOMMENDATIONS AND WARNINGS
- CONTENTS
- INSTALLATION
- PRECAUTIONS WHEN USING THE LED FIXTURE
- INSPECTION, MAINTENANCE AND REPAIR
- STORAGE AND DISPOSAL
- WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
XT 1000W CO2 Pro
Linear Multi-Light Bar LED Fixture
User Manual
INTRODUCTION
Thank you for purchasing the XT 1000W CO2 Pro linear multi-light bar LED fixture. This manual describes how to install and use the XT 1000W fixture; please read this manual thoroughly before attempting to install or operate any XT Series LED system.
PRODUCT DESCRIPTION
The XT 1000W CO2 Pro LED is an electronic horticultural LED fixture using a
linear array design with ten 100W LED light bars. The XT 1000W CO2 Pro is a
highly efficient ultra-high intensity full-cycle grow lighting solution for
commercial horticulture cultivation.
The XT 1000W CO2 Pro has the power and flexibility to scale from vegetative
growth to higher light intensities in bloom.
Designed for use in a CO² enriched environment, the XT 1000W CO² Pro LED can
be positioned closer to the plant canopy for very high PPFD levels which
require supplemental carbon dioxide (CO²) for crops to fully utilise for
photosynthesis.
The XT 1000W CO2 Pro LED can be used without supplemental CO² but should be
positioned at a greater hanging height from plant canopy, increasing the light
footprint but reducing the PPFD level.
In this manual the XT 1000W CO2 Pro LED will be referred to as: “the LED
fixture
PRODUCT INFORMATION AND SPECIFICATIONS
3.1 General Product Information
PRODUCT NAME | Photontek XT 1000W CO2 Pro LED |
---|---|
MANUFACTURER | PhotonTek Horticultural Lighting |
PRODUCT CODE | PTEKLED020 |
EAN | 5060560030997 |
PLUG TYPE | NEMA 5-15P – 120V mains supply |
3.2 Technical Specifications
PARAMETER | VALUE | PARAMETER | VALUE |
---|---|---|---|
INPUT VOLTAGE | 120 – 277V, 50/60Hz AC | Waterproof/Dustproof | IP65 – Fixture |
IP67 – Driver
INPUT POWER (100%)| 1025W| Dimensions| 46.5” x 42.95” x 4.16”
INPUT CURRENT
@ 120V, 100% O/P| 8.4A max| Weight| 39.68lbs
@ 277V, 100%| 3.6A max| |
POWER FACTOR| >0.97| Life Span| >50000H
PPF| 2925 µmol/s| Working Temperature
LED Driver Attached| -20º — +40ºC
Working Temperature
LED Driver Remote 5m ext| 0º — 40ºC
EFFICACY| 2.9 µmol/J| Working Humidity| 20% – 90%
SPECTRUM| Full Spectrum| Manual dim/External lighting controller| 0-10V
Analog Protocol
LIGHT SOURCE| LUMILEDS & Osram diodes| Beam angle| 120º
3.3
Spectra 3.4 Light
distribution curve 3.5 Environment
The LED fixture is intended to be used in climate-controlled grow rooms and
indoor farms. The product may be used in damp environments but may not be used
in wet environments or outdoors.
The product will operate in ambient temperatures from -20ºC to 40ºC but will
function at optimal level between 20ºC to 30ºC.
The product will operate in 20% – 90% humidity, non-condensing.
3.6 Legal
This product is FCC, IC, CSA & CE certified compliant with LVD and EMC
directive test standards.
SAFETY RECOMMENDATIONS AND WARNINGS
WARNING!
Carefully read the warnings below before using or working with the product!
-
Always adhere to the local rules and regulations when installing or using the LED fixture.
-
Do not open or disassemble the LED fixture as it contains no serviceable parts inside. Opening or modifying the LED fixture can be dangerous and will void the warranty.
-
Do not use the LED fixture when either the LED fixture or its power cord are damaged. Replace the power cord with correctly rated cord only.
-
Modifications to the cabling can lead to unwanted electromagnetic effects which may make the product not comply with legal requirements.
-
Do not expose the LED fixture to:
Condensing humidity, heavy mist or direct spray;
Ambient temperatures outside the specified range;
Dust and contamination;
Direct sunlight during use or HID light that may heat up the driver. -
Always disconnect the LED fixture from mains before performing any maintenance.
-
Always allow for a cool down period of at least 20-30 minutes before touching the LED light bars. Touching the LED bars when the fixture is lit or immediately after may result in burns!
-
Natural convection removes heat away from the heatsink. In order for the system too properly cool itself, at least 5cm of space is required between the fixture and the roof of your grow area.
-
Do not use abrasive materials or aggressive cleaning agents to clean the LED fixture as this may damage the secondary optics. Instead use a clean dry fabric/cloth.
-
Do not use the LED fixture near flammable, explosive or reactive substances. The LED fixture can reach tempera tures of 40ºC.
-
Do not use sulphur vaporizers or water misters.
-
The installation and use of the LED fixture is the responsibility of the end user. Incorrect use or installation can lead to failure and damage to the LED fixture. Damage to the LED fixture and electronic circuitry as a result of incorrect installation and use revokes the warranty.
CONTENTS
INSTALLATION
WARNING!| Mounting and installing the LED fixture must be in accordance
with the applicable local laws and regulations.
---|---
WARNING!| The installer is responsible for correct and safe
installation.
WARNING!| Ensure the local cabling can support the voltage and current
requirements of the LED fixture.
WARNING!| Avoid coiled cords and keep mains leads separated to help
prevent electromagnetic interference.
WARNING!| Do not connect or disconnect the LED fixture under load.
6.1 Fixture assembly & installation
Please take care when assembling fixture and ensure all connections are true
and secure
6.1.1 Assemble the frame
Connect Frame A and B to the support frame by pressing button on frame
connector and inserting into support frame socket and lock. Ensure button
clicks into hole socket to lock. Connect Frame B to support frame end near LED
driver power output & dimming female connectors.
Note the direction when installing; the LED driver mounting bracket is on top
when the fixture is hung.
6.1.2 Connect & disconnect the driver
The LED driver is fixed to the mounting bracket with four retention screws
through bracket into driver base plate. For greater flexibility the driver can
be disconnected from the fixture and used remotely using Photontek 5m LED
driver extension cables (sold separately).To connect driver output and dimming to
fixture; ensure the power and dimming self-locking male connectors are
correctly aligned with corresponding female connectors on driver and push
together until click-locked.
To disconnect; turn male connector anti-clockwise to unlock and pull apart
from female.
6.1.3 Connect the LED light bars
WARNING!
The light bars are shipped with protective plastic covers over the diodes.
Please ensure these protective covers are removed before use!
6.2 Changing and replacing light bars and modular use
Individual 100W light bars are available to purchase as replacements or with
different spectral ratios to adjust fixture spectral output.
The LED fixture’s modular design uses an intelligent LED driver which can
decrease or increase power to match the amount of 100W light bars installed on
the fixture automatically. If not all light bars are required, the driver will
only draw power required for the amount of light bars connected eg if six
light bars are connected the driver will only draw 600W at 100% to power them.
WARNING!
At least one light bar must be installed in the fixture before switching on.
6.3 Installing the fixture
WARNING!
Mount the system to something that can hold the weight of the LED fixture.
Ensure all light bars are installed correctly and are secure. Carefully turn
the fixture over and attach the metal cable hangers to the mounting hooks.
Hang the fixture in required position and height. Ensure the fixture is hung
horizontally.
For shorter hanging heights (50cm) from plant canopy and a 5 x 5ft footprint;
supplemental carbon dioxide (CO²) is recommended so that the plants can
photosynthesize the very high level PPFD produced at this height.
For PPFD over 1000µmol/s/m² up to max 1500µmol/s/m² supplemental CO² at a 1:1
ratio is recommended. i.e. at 1500µmol/s/m² PPFD supplemental CO² at 1500ppm
is advised.
Warning! Exposing crops to ultra high PPFD without supplemental CO² can
be detrimental to plant growth.
The LED fixture can be used without supplemental CO² at greater hanging
heights (1m+) as this will decrease PPFD and will increase light footprint to
6 x 6ft.
6.4 Connecting
the manual dimmer or external lighting controller
The dimmer control or lighting controller is connected to the Signal IN
connector on the fixture. This enables light intensity (PPF level) to be
adjusted according to requirement. The LED fixture light intensity can be
adjusted without changing spectral power distribution or losing
efficiency. 6.5 Connecting Fixtures in series for External Control
For detailed instructions please refer to the PhotonTek Digital Lighting
Controller manual.
The LED Fixture uses 0-10V signal protocol for control.
Position and hang each fixture appropriately.
- Connect controller output signal wire to fixture 1 SIGNAL in connector. Connect signal wire from fixture 1 SIGNAL OUT connector to fixture 2 SIGNAL IN connector.
- Continue to connect fixtures in series for up to 100 fixtures per controller, see figure below..
6.6 Connecting the LED fixture to the mains
WARNING!
Make sure mains power is switched off.
WARNING!
Ensure the power supply cord is not coiled and does not touch any hot
surfaces.
WARNING!
Connect the cabling according to local rules, safety regulations and
electrical code.
WARNING!
If not using an external lighting controller ensure external switching gear
can cope with the inrush current of the LED fixture. Always use a timer
contactor suitable for switching a capacitive load. Never use household timers
to switch the LED fixture!
WARNING!
Ensure power cord rating matches mains supply voltage.
- The LED fixture is supplied with a 120V power cord for 120V power supply. 240V and 277V power cords are not included and must be purchased separately.
- Select the correctly rated cord for your mains power supply and connect driver power input socket to switching gear/power supply.
- Ensure the LED driver power supply cord self-locking female connector is correctly aligned to the corresponding male connector on driver and push together until click-locked. To disconnect; turn female connector anti-clockwise to unlock and pull apart from driver
- Connect mains power plug to switching gear/power supply.
- Switch on mains power.
WARNING!
Do not connect or disconnect the LED fixture under load.
PRECAUTIONS WHEN USING THE LED FIXTURE
WARNING!
Always ensure at least one light bar is connected to the fixture before
switching on. LED Fixture has an intelligent LED driver which will increase or
decrease power to match the amount of light bars connected to the system.
WARNING!
Always wait 20 – 30 minutes for the LED light bars to cool down.
INSPECTION, MAINTENANCE AND REPAIR
WARNING! Disconnect the LED fixture from mains before performing any
maintenance or repairs.
WARNING! Do not connect or disconnect the LED fixture under load
WARNING! Do not open or disassemble the LED fixture, it contains no
serviceable parts inside.
Opening the LED fixture can be dangerous and will void the warranty.
WARNING! Always wait 20 – 30 minutes for the LED light bars to cool down.
CAUTION! Do not clean the LED fixture with detergents, abrasives or other
aggressive substances.
- Regularly check the LED fixture for dust or dirt build up. Clean if necessary. Contamination may cause overheating and decreased performance.
- Clean the outside of the LED fixture using a dry or damp cloth.
- Regularly check the cords of the LED fixture to ensure it is undamaged.
STORAGE AND DISPOSAL
Store the LED fixture in a dry and clean environment, with an ambient
temperature of -25ºC to 55ºC.
The product must not be discarded as unsorted municipal waste but must be
collected separately for the purpose of treatment, recovery and
environmentally sound disposal.
WARRANTY
PhotonTek warrants the mechanical and electronic components of their product to be free of defects in material and workman-ship if used under normal operating conditions for a period of five (5) years from the original date of purchase. If the product shows any defects within this period and that defect is not due to user error or improper use PhotonTek shall, at its discretion, either replace or repair the product using suitable new or reconditioned products or parts. In case PhotonTek decides to replace the entire product, this limited warranty shall apply to the replacement product for the remaining initial warranty period, i.e. five (5) years from the date of purchase of the original product. For service; return the product to your shop with the original sales receipt.
FOLLOW US ON OUR
SOCIAL MEDIA CHANNELS info@photontek-lighting.com
www.photontek-lighting.com
References
- Sustainable LED lighting solutions | Philips lighting
- PHOTONTEK Lighting | LED lighting | LED grow lights | LED Fixtures