Beijing Ultrasonic BJA500 Ultrasonic Mist Maker Humidifier 12PCs LED User Manual
- June 6, 2024
- Beijing Ultrasonic
Table of Contents
BJA500 USER MANUAL
(500ML/L ULTRASONIC ATOMIZER)
Specification
Type | BJA500 |
---|---|
Atomizing Quantity | >550ML |
Size | 46mm diameter 25mm height |
Working Frequency | 1700±50(KHZ) |
Diameter of piezoceramics | 20mm |
Working Temperature | 5~45℃ |
Water Level | 40mm-60mm |
Working Voltage | 24V AC/DC 700MA |
Power: | 24W |
Material | Plastics |
LED | Not |
Water Level Sensor | Height 12mm |
Cable | Black 3.8mm PVC Length 1400±20mm |
Plug for the atomizer | 5.5*2.5mm socket |
Pictures Showing:
Product Advantage:
- Copper shell.Plating nickel chrome.Good heat dissipation.
- Atomized particles are small.
- Humidification efficiency: a large quantity of humidification, humidification significantly faster results.
- Overheating protection and Lack of water protection.
- Easy to replace the disc piezoceramics and clean the piezoceramics.
Brief Introduction
ultrasonic negative ionizing mist maker is a technological product, which its
integration of aroma diffuser and air refresher, help to freshen the air, and
the mist will add air humidity and clear static electricity, all the things
are well for the human body. If adding one or two drops of disinfectant or
aroma liquid, not only it can disinfect and sterilize the air, but also make
the room full of fragrant air.
Make sure to put the mist maker in water, it can easily be misting. Its wide
usage is in different craft articles, rockery garden fountain decoration and
beautification range, also in the hotel place, even the appliance installation
of industry humidification.
Operating Instructions
-
When taking out the mist maker from the package(please don’t crash the water level sensor).put it in the deep 40mm-80mm water.
the best working effect is keeping 30mm to 50mm of water above ceramic disc, If water is too deep, it can not spray mist, but if water is too shallow, it will stop to spray mist automatically, also when the water –level sensor switch is out of water. It will also stop working.
Pls, notice that there are no obstacles within the scope of more than 100mm space of the sprayer ceramic water level. -
The Spray indicator light will be bright after connecting the mist maker with the power supply, then the ultrasonic atomizer will work.
If the spray lights flash and the atomizer doesn’t work, this means that there was not enough water. -
As the mist maker normally working, the water in the container will constantly evaporate, when the water is below the water level sensor, it will automatically be protected and stop misting, at this time the spray lights will flash. After adding the water above the water level sensor, it continues misting.
-
At the beginning of the work, the atomization quantity may be small, it will be stable misting and become large after working sometime. When the winter is coming, the weather will affect the misting rate, you can put some hot water to speed its stable misting rate.
-
When you don’t use the mist maker for a long time, please make sure to pull the transformer/adapter input lead wires out, which can avoid the accident/ unfortunate happening.
Matters Needing Attention, Services, and Maintenance
- Pls, operate them according to our instructions. Check the input voltage of the transformer(generator) if it’s suitable for your local voltage standard before using it.
- When the mist maker normally works, inevitable meeting produces certain heat caused by temperature rise, at this time, we need to pour enough water in the container to heat eliminate.
- Please don’t be covered by sundries above the mist maker, and hold more than 100mm space of the sprayer, also can’t put the atomizer in the sealed container.
- Please don’t let the mist maker work under the high-temperature water when the temperature exceeds 50℃, the hyperthermia/ superheating protection can play an important part, the misting will be stopped, only the indication light shines, when the water temperature is below 40℃, it will normally continue working. It is not allowed to work in a freezing environment.
- Please don’t put it beside the TV or other electric equipment, avoid damaging them when the mist maker produces misting
- Suited Transformer/Adapter/Generator should keep away from the sprayer, and the sprayer water can spill out and make it wet directly, due to the plug which is connected to the sprayer can’t be put into the water or wet.
- In order to ensure the mist maker/sprayer/atomizer normally working in a nice environment, please change the water every week, and use the clean soft cloth or rag to clean the ceramic and water level sensor, but don’t use the chemical agent to clean, even also can’t use hard or edge tool.
- When the mist maker works, don’t put your hand above the sprayer, or else it will make you a smart feeling.
- Although the adapter(transformer) for the mist maker is used outdoor, it can’t allow be put into the water.
Replace Method of Disc Piezoelectric Ceramic
after the mist maker is used for a long time, its misting rate will be
reduced, you can replace the ceramic disc to make it normally work at this
time.
Methods as follows:
- Use the ceramic disc key to wring out the copper ring in an anticlockwise direction, and take it out, please see clearly the ceramic disc face and bottom side.
- Put the new ceramic disc in the original place(Please take attention to the installation direction accorded with the same as the original one.)
- Put the copper ring, and use the ceramic disc key to screw down in the clockwise direction.
- Please put the mist maker in the water container again, it can normally work as before.
How to replace the piezoceramics.
-
With screwdriver through the two holes. Reverse open the top black part as the picture.
-
take down the pressure ring, and take out the old piezoceramics.
change the new piezoceramics. turn the black part clockwise to tighten the bit
as the picture.
Read User Manual Online (PDF format)