S2 Smart Start On/Off Switch
S2 SmartStart On/Off Switch Manual
Federal Communications Commission (FCC) Statement FCC Caution: Any changes or
modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate this equipment. This device
complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that
may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures: Reorient or relocate
the receiving antenna. Increase the separation between the equipment and
receiver. Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected. Consult the dealer or an experienced
radio/TV technician for help. This equipment should be installed and operated
with a minimum distance of 20cm between the radiator and your body.
IC Caution:
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
DECLARATION DE CONFORMITE D’INDUSTRIE CANADA
WARRANTY
Evalogik Products warrants this product to be free from manufacturing defects
for a period of two years from the original date of consumer purchase. This
warranty is limited to the repair or replacement of this product only and does
not extend to consequential or incidental damage to other products that may be
used with this product.
This warranty is in lieu of all other warranties, expressed or implied. Some
states do not allow limitations on how long an implied warranty lasts or
permit the exclusion or limitation of incidental or consequential damage, so
the above limitations may not apply to you.
This warranty gives you specific rights, and you may also have other rights
which vary from state to state. if the unit should prove defective within the
warranty period.
SPECIFICATIONS
Model: ZW30S
Power: 120 VAC, 60 Hz.
Signal (Frequency): 908.42 MHZ.Maximum load for outlet 15A, 960W
Resistive
Maximum load for the Z-Wave™ controlled outlet: 600W Incandescent, ½ HP
Motor or 600W Resistive
Range: Up to 100 feet line of sight between the Wireless Contr and the
closest Z-Wave™ receiver module.
Operating Temperature Range: 32-104° F (0-40° C)
Specifications subject to change without notice due to continuing product
improvement
Website: www.nie-tech.com
WARNING
RISK OF FIRE RISK OF ELECTRICAL SHOCK RISK OF BURNS
CONTROLLING APPLIANCES: EXERCISE EXTREME CAUTION WHEN USING Z-Wave™
DEVICES TO CONTROL APPLIANCES. OPERATION OF THE Z-Wave™ DEVICE MAY BE IN A
DIFFERENT
roller ROOM THAN THE CONTROLLED APPLIANCE, ALSO NUNINTENTIONAL ACTIVATION MAY
OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave™ DEVICES MAY
AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING. DEPENDING UPON
THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL OPERATIONS COULD POSSIBLY
RESULT IN A HAZARDOUS CONDITION. FOR THESE
REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE
THE FOLLOWING:
DO NOT USE Z-Wave™ DEVICES TO CONTROL ELECTRIC
HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT
A HAZARDOUS CONDITION DUE TO UNATTENDED OR UNINTENTIONAL OR AUTOMATIC POWER-ON
CONTROL.
Introduction:
This product can be operated in any Z-Wave network with other Z-Wave Plus™
certified devices from other manufacturers. All non-battery-operated nodes
within the network will act as repeaters regardless of vendor to increase the
reliability of the network. Each module is designed to act as a repeater,
which will re-transmit a radio frequency (RF) signal by routing the signal
around obstacles and radio dead spots to ensure that the signal is received at
its intended destination. ZW30S is a security-enabled Z-Wave Plus™ device.
Security Enabled Z-Wave Plus™ Controller must be used in order to fully
utilize the product. The Device Type of the ZW30S is an on/off power switch.
The Role Type of the ZW30S is Always On Slave Role Type
Key Features:
—Remote ON/OFF control via the Z-Wave™ controller
—Manual ON/OFF control with the front panel push button
—Support Association Group and Auto Report switch status
—Support firmware upgrades via Over-the-air (need Gateways support)
—Support Scenes
Product Overview:
A. Up Push button
B. Down Push button
C. Load1 (Black)
D. Lin (Black) – Line in
E. Nin (White) – Neutral in
F. 3-way (RED)
ZW30S Installation Wiring Diagram
A. LINE (Hot) — Black (connected to power)
B. NEUTRAL — White C. LOAD— Black (connected to lighting)
D. GROUND — Green/Bare E. TRAVELER — Red/Other (only in 3-way installations)
Key function description
Function 1: Press the up or down button to turn the output ON or OFF
Function 2: quickly press 3x upper paddle: inclusion (only if the switch
is not included in network)quickly press 3x lower paddle: exclusion
Function 3: quickly press upper paddle 6x to change Status LED
Configuration
Function 4: Press and hold lower paddle for 10 seconds, then LED starts
blinking, release paddle and within 2 seconds, click lower paddle 5 times
(Node: Please use this procedure only when the network primary controller
is missing or otherwise inoperable.)
Function 5: Tap A(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.
Function 6: Tap B(1x/2x/3x/4x/5x/Hold/Release) Activate the scene.
Adding Your Device To A Hub
The device support two methods of inclusion, When using a Z-Wave Plus™
certified controller choose Network Wide Inclusion or SmartStart, Network
Wide Inclusion To A Z-Wave™ Network
- Refer to your primary controller instructions to process the inclusion/exclusion setup procedure.
- When prompted by your primary controller, click the Up or Down button three times in one second.
The device is compatible with SmartStart
SmartStart enabled products can be added into a Z-Wave™ network by scanning the Z-Wave QR Code found on the top of the outlet or the back of the box with a controller providing SmartStart inclusion.No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on and in the network vicinity.
QR CODE
the QR code is stuck to the side of the case, DSK is included in the QR code.
DSK
The DSK code can be found on the DSK label which is attached to the
packaging box.
Z-Wave™ protocol Command Class Node Info
COMMAND_CLASS_ZWAVEPLUS_INFO_V2,
COMMAND_CLASS_SWITCH_BINARY_V2,
COMMAND_CLASS_CONFIGURATION_V4,
COMMAND_CLASS_CENTRAL_SCENE_V3,
COMMAND_CLASS_ASSOCIATION_V3,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3,
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3,
COMMAND_CLASS_TRANSPORT_SERVICE_V2,
COMMAND_CLASS_VERSION_V3,
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1,
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1,
COMMAND_CLASS_INDICATOR_V3,
COMMAND_CLASS_POWERLEVEL_V1,
COMMAND_CLASS_SECURITY_2,
COMMAND_CLASS_SUPERVISION_V1,
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
The Below listed Command Class are all supported the Security S2
COMMAND_CLASS_VERSION_V2,
COMMAND_CLASS_SWITCH_BINARY_V2,
COMMAND_CLASS_CONFIGURATION_V4,
COMMAND_CLASS_CENTRAL_SCENE_V3,
COMMAND_CLASS_ASSOCIATION_V3,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3,
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3,
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1,
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1,
COMMAND_CLASS_INDICATOR_V3,
COMMAND_CLASS_POWERLEVEL_V1,
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
Z-Wave™ Configuration Parameters
You may use the below configuration parameters to change the settings of the corresponding functionality.
-
Locally Button function
Parameter No: 1(0x01)
Size: 1 Byte
Value: 00(default)
Value: 01
Value: 02
Up Button ON, Down Button OFF
Up Button OFF, Down Button ON
Up button ON/OFF, Down Button ON/OFF -
Status LED Configuration
Parameter No: 2(0x02)
Size: 1 Byte
Value: 00(default)
Value: 01
Value: 02 Value: 03
Output and the LED are in different states.
Output and the LED are in the same state.
LED Always OFF
LED Always ON -
Auto Turn-Off Timer
** Parameter No: 3(0x03)
Size=4 ,
Values: 0 (minutes) default;
Values:** 1 – 65535 (minutes); -
Auto Turn-Off Timer
Parameter No: 5(0x05),
Size= 4,
Values: 0 (minutes) default;
Values: 1 – 65535 (minutes); -
Restores state after power failure parameter
No: 11(0x0B)
Size=1,
Default = 1
Value= 0
Value= 1
Value= 2
disable local button and External Switch control, enable Z-Wave™ control
enable local button and External Switchcontrol, enable Z-Wave™ control
disable local button and External Switch control -
external switch type
Parameter No: 12(0x0C)
Size: 1 ,
Default = 0
Value: 0
Value: 01
Value: 02
toggle switch(device changes status when switching changes status) momentary switch electronic add-on switch -
Behavior when Output control disabled
Parameter No: 13(0x0D)
Size: 1 , Default = 0
Value: 0
Report on/off status and change LED indicator when upper or lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled).
Value: 01
DON’t report on/off status or change LED indicator when the upper or lower paddle is pressed and Parameter 11 is set to value 0 or 2 (output control disabled). -
LED Indicator Color
Paramter No: 14(0x0E)
Size: 1 ,
Default =1
Value: 0 White
Value: 01 Blue
Value: 02 Green
Value: 03 Red -
LED Indicator Brightness
Paramter No: 15(0x0F)
Size: 1 ,
Default = 1
Value: 00 Bright (100%)
Value: 01 Medium (60%)
Value: 02 Low (30%) -
Association reports
Paramter No: 16(0x10)
Size: 1 ,
Default = 1
Value: 00 Z-Wave™ control: Binary switch report, Manual control: Basic set report
Value: 01 Z-Wave™ control: Basic set report control: Binary switch report, Manual control: Binary switch report
Support for Association Groups
ZW30S supports 3 association groups. Group 1 supports 1 node ID, Group 2 and
Group 3 Supports a maximum of 5 node ID’s Association group_1:Z-Wave™ Plus
Lifeline
Association group_1 is defaulted to associate with the primary controller
(Gateway/Hub/Controller) for ZW30S Status change report,
- ZW30S will trigger the AUTO report function if the Switch status had been changed. (ex. Switch Binary Report/Basic Report/Central Scene Notification/ Device Reset Locally Notification)
Association group_2:basic set command
When the output of the ZW30S is changed, On (0xFF) or Off (0x00). The ZW30S
will automatically send out a related basic set command. On (0xFF) or Off
(0x00) to its associated group.
Association group_3:basic set command
When the output of the ZW30S is changed, On (0xFF) or Off (0x00). The ZW30S
will automatically send out a related basic set command. On (0xFF) or Off
(0x00) to its associated group.
Restoring Factory Defaults
ZW30S is removed from the network and will be restored to the factory setting
All Configuration Parameters values and Association information will be
restored to factory default settings and excluded from the network. Manual
Reset: Press and hold lower paddle for 10 seconds, then LED starts blinking,
release paddle and within 2 seconds, click lower paddle 5 times Remark: All
the settings and data will be permanently deleted. Please use this procedure
only when the network primary controller is missing or otherwise inoperable.
Read User Manual Online (PDF format)