Evaloigk S2 Samrt Switch Scenes ZW35 Manual

June 8, 2024
EVALOIGK

Evaloigk

S2 Samrt Switch Scenes

SKU: ZW35

Quickstart

This is a
secure
Binary Switch
for
.

To run this device please connect it to your mains power supply.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

In-Wall Smart Switch design features a housing depth that is up to 20 percent smaller than the previous Z-Wave models. This reduced size coupled with the elimination of heat taps provides a better fit in older style boxes and multi- gang configurations. SimpleWire technology allows line and load to automatically be configured with auto-sensing line-load terminals. All of this is coupled with Z-Wave S2 and SmartStart allows for effortless installation while being safer than ever!

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1 1 Z-Wave Lifeline
2 5 sendon/off control
3 5 send SWITCH MULTILEVEL
4 5 send on/off contro
5 5 send SWITCH MULTILEVEL
6 5 send on/off contro
7 5 send SWITCH MULTILEVEL
8 5 send on/off contro
9 5 send SWITCH MULTILEVEL
10 5 send on/off contro
11 5 send SWITCH MULTILEVEL

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: LED Indicator mode for relay/button A

Parameter No: 1(0x01) Size:1 Byte(default=0) Value: 00LED on when relay off, LED off when relay on Value: 01LED on when relay on, LED off when relay off Value: 02LED always off Value: 03LED always on
Size: 1 Byte, Default Value: 0

SettingDescription

0 LED on when relay off, LED off when relay on
1 LED on when relay on, LED off when relay off
2 LED always off
3 LED Always ON

Parameter 10: LED Indicator color for Button E

Parameter No: 10(0x0A) Size:1 Byte(default=0) Value: 00white Value: 01blue Value: 02green Value: 03red
Size: 1 Byte, Default Value: 0

SettingDescription

0 White
1 Blue
2 Green
3 Red

Parameter 11: LED Indicator brightness for relay/button A

Parameter No: 11(0x0B) Size:1 Byte(default=1) Value: 00 bright (100%) Value: 01 medium (60%) Value: 02 low (30%)
Size: 1 Byte, Default Value: 1

SettingDescription

0 Bright (100%)
1 Medium (60%)
2 Low (30%)

Parameter 12: LED Indicator brightness for Button 1

LED Indicator brightness for Button 1
Size: 1 Byte, Default Value: 1

SettingDescription

0 Bright (100%)
1 Medium (60%)
2 Low (30%)

Parameter 13: LED Indicator brightness for Button 2

LED Indicator brightness for Button 2
Size: 1 Byte, Default Value: 1

SettingDescription

0 Bright (100%)
1 Medium (60%)
2 Low (30%)

Parameter 14: LED Indicator brightness for Button D

Parameter No: 14(0x0E) Size:1 Byte(default=1) Value: 00 bright (100%) Value: 01 medium (60%) Value: 02 low (30%)
Size: 1 Byte, Default Value: 1

SettingDescription

0 Bright (100%)
1 Medium (60%)
2 Low (30%)

Parameter 15: LED Indicator brightness for Button E

Parameter No: 15(0x0F) Size:1 Byte(default=1) Value: 00 bright (100%) Value: 01 medium (60%) Value: 02 low (30%)
Size: 1 Byte, Default Value: 1

SettingDescription

0 Bright (100%)
1 Medium (60%)
2 Low (30%)

Parameter 16: Auto Turn-Off Timer for Relay

Parameter No: 16(0x10) Size:4 Byte(default=0) Value: 0-65535(minutes)
Size: 4 Byte, Default Value: 0

SettingDescription

0 – 65535 Auto Turn-Off Timer for Relay

Parameter 17: Auto Turn-ON Timer for Relay

Parameter No: 17(0x11) Size:4 Byte(default=0) Value: 0-65535(minutes)
Size: 4 Byte, Default Value: 0

SettingDescription

0 – 65535 Auto Turn-ON Timer for Relay

Parameter 18: Restores state after power failure

Parameter No: 18(0x12) Size:1 Byte(default=0) Value: 00 Relay and buttons remember and restore last state Value: 01 Relay and buttons forced to off after power failure Value: 02 Relay and buttons forced to on after power failure
Size: 1 Byte, Default Value: 0

SettingDescription

0 Relay and buttons remember and restore last state
1 Relay and buttons forced to off after power failure
2 Relay and buttons forced to on after power failure

Parameter 19: Disable / Enable Control on the Relay

Parameter No: 19(0x13) Size:1 Byte(default=1) Value: 00 Disable local / physical control (from the button), enable Z-Wave control
Size: 1 Byte, Default Value: 1

SettingDescription

0 Disable local / physical control (from the button), enable Z-Wave control
1 Enable local / physical control (from the button), enable Z-Wave control
2 Disable local / physical control (from the button), disable Z-Wave control

Parameter 2: LED Indicator mode for Button B

Parameter No: 2(0x02) Size:1 Byte(default=0) Value: 00LED on when relay off, LED off when relay on Value: 01LED on when relay on, LED off when relay off Value: 02LED always off Value: 03LED always on
Size: 1 Byte, Default Value: 0

SettingDescription

0 lLED on when relay off, LED off when relay on
1 LED on when relay on, LED off when relay off
2 LED Always OFF
3 LED Always ON

Parameter 20: Disable / Enable Control on the Relay

Parameter No: 20(0x14) Size:1 Byte(default=1) Value: 00 report on/off status when button is pressed and change LED indicator status if Parameter 19 is set to value 0 or 2 Value: 01 DONT report on/off status when button is pressed and DONT change LED indicator status if Parameter 19 isset to value 0 or 2 but the relay will always send central scene command)
Size: 1 Byte, Default Value: 1

SettingDescription

0| report on/off status when button is pressed and change LED indicator status if Parameter 19 is set to value 0 or 2
---|---
1| DONT report on/off status when button is pressed and DONT change LED indicator status if Parameter 19 is set to value 0 or 2 but the relay will always send central scene command)

Parameter 3: LED Indicator mode for Button C

Parameter No: 3(0x03) Size:1 Byte(default=0) Value: 00LED on when relay off, LED off when relay on Value: 01LED on when relay on, LED off when relay off Value: 02LED always off Value: 03LED always on
Size: 1 Byte, Default Value: 0

SettingDescription

0 LED on when relay off, LED off when relay on
1 LED on when relay on, LED off when relay off
2 LED Always OFF
3 LED Always ON

Parameter 4: LED Indicator mode for Button D

Parameter No: 4(0x04) Size:1 Byte(default=0) Value: 00LED on when relay off, LED off when relay on Value: 01LED on when relay on, LED off when relay off Value: 02LED always off Value: 03LED always on
Size: 1 Byte, Default Value: 0

SettingDescription

0 LED on when relay off, LED off when relay on
1 LED on when relay on, LED off when relay off
2 LED Always OFF
3 LED Always OFF

Parameter 5: LED Indicator mode for Button E

Parameter No: 5(0x05) Size:1 Byte(default=0) Value: 00LED on when relay off, LED off when relay on Value: 01LED on when relay on, LED off when relay off Value: 02LED always off Value: 03LED always on
Size: 1 Byte, Default Value: 0

SettingDescription

0 LED on when relay off, LED off when relay on
1 LED on when relay on, LED off when relay off
2 LED Always OFF
3 LED Always ON

Parameter 6: LED Indicator color for relay/button A

Parameter No: 6(0x06) Size:1 Byte(default=0) Value: 00white Value: 01blue Value: 02green Value: 03red
Size: 1 Byte, Default Value: 0

SettingDescription

0 White
1 Blue
2 Green
3 Red

Parameter 7: LED Indicator color for Button B

Parameter No: 7(0x07) Size:1 Byte(default=0) Value: 00white Value: 01blue Value: 02green Value: 03red
Size: 1 Byte, Default Value: 0

SettingDescription

0 White
1 Blue
2 Green
3 Red

Parameter 8: LED Indicator color for Button C

Parameter No: 8(0x08) Size:1 Byte(default=0) Value: 00white Value: 01blue Value: 02green Value: 03red
Size: 1 Byte, Default Value: 0

SettingDescription

0 White
1 Blue
2 Green
3 Red

Parameter 9: LED Indicator color for Button D

Parameter No: 9(0x09) Size:1 Byte(default=0) Value: 00white Value: 01blue Value: 02green Value: 03red
Size: 1 Byte, Default Value: 0

SettingDescription

0 White
1 Blue
2 Green
3 Red

Technical Data

Hardware Platform ZGM130
Device Type Binary Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 7.13.6
Certification ID ZC12-21020176
Z-Wave Product Id 0x0312.0xBB00.0xBB08
Firmware Updatable Updatable by Consumer by RF
Color White
Z-Wave Scene Type Scene & Central Scene
Switch Type Push Button Illuminated
Security V2 S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info V3
  • Association V3
  • Basic V2
  • Central Scene V3
  • Configuration V4
  • Device Reset Locally
  • Firmware Update Md V5
  • Indicator V3
  • Manufacturer Specific V2
  • Multi Channel Association V4
  • Powerlevel
  • Security 2
  • Supervision
  • Switch Binary V2
  • Transport Service V2
  • Version V3
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

EVALOIGK User Manuals

Related Manuals