Evaloigk Z-Wave Mutil-relay ZW12 Manual
- June 8, 2024
- EVALOIGK
Table of Contents
- Evaloigk
- Z-Wave Mutil-relay
- SKU: ZW12
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Restore state after power failure
- Parameter 10: Input 1 trigerring
- Parameter 11: Input 2 trigerring
- Parameter 12: EP1 Manual Control
- Parameter 13: EP2 Manual Control
- Parameter 15: EP1 Auto Turn-Off Timer Unit
- Parameter 16: EP1 Auto Turn-ON Timer Unit
- Parameter 17: EP2 Auto Turn-Off Timer Unit
- Parameter 18: EP2 Auto Turn-ON Timer Unit
- Parameter 2: Select switch one’s type
- Parameter 24: Sw1,Sw2 setting
- Parameter 3: Select switch two’s type
- Parameter 5: LED indicator
- Parameter 6: EP1 Auto Turn-off Timer
- Parameter 7: EP1 Auto Turn-on Timer
- Parameter 8: EP2 Auto Turn-off Timer
- Parameter 9: EP2 Auto Turn-on Timer
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Evaloigk
Z-Wave Mutil-relay
SKU: ZW12
Quickstart
This is a
secure
Binary Switch
for
.
To run this device please connect it to your mains power supply.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
This product is a multi-channel Z-Wave breaker with built-in S2 security .Built-in high-power relay, multi-type external switch selection.Very convenient.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 1 | Z-Wave Lifeline |
---|---|---|
2 | 5 | Send on/off control |
3 | 5 | Send on/off control |
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Restore state after power failure
Restore state after power failure: always off, always on or follow the
status before power failure
Size: 1 Byte, Default Value: 1
SettingDescription
0 | All relays automatically turn OFF once power is restored |
---|---|
1 | All relays remember the status prior to power outage and turns back to it |
2 | All relays turned on after power failure |
3 | R1 recovered, R2 ON |
4 | R2 recovered, R1ON |
Parameter 10: Input 1 trigerring
Connect input and output or separate the output from the input for switch 1
Size: 1 Byte, Default Value: 1
SettingDescription
0 | trigger disable (only notification to hub according to set par 2) |
---|---|
1 | trigger unable (default); trigger the relay and hub notification |
Parameter 11: Input 2 trigerring
Connect input and output or separate the output from the input for switch 2
Size: 1 Byte, Default Value: 1
SettingDescription
0 | trigger disable (only notification to hub according to set par 2) |
---|---|
1 | trigger unable (default); trigger the relay and hub notification |
Parameter 12: EP1 Manual Control
User can set it to disable the output for switch one
Size: 1 Byte, Default Value: 1
SettingDescription
0 | manual control disabled (no reports to the hub) |
---|---|
1 | manual control enabled |
2 | manual control disabled (sends on/off reports to the hub) |
Parameter 13: EP2 Manual Control
User can set it to disable the output for switch two
Size: 1 Byte, Default Value: 1
SettingDescription
0 | manual control disabled (no reports to the hub) |
---|---|
1 | manual control enabled |
2 | manual control disabled (sends on/off reports to the hub) |
Parameter 15: EP1 Auto Turn-Off Timer Unit
Setting auto off timer unit(minutes, seconds or hours) for relay one
Size: 1 Byte, Default Value: 0
SettingDescription
0 | minutes |
---|---|
1 | seconds |
2 | hours |
Parameter 16: EP1 Auto Turn-ON Timer Unit
Setting auto on timer unit(minutes, seconds or hours) for relay one
Size: 1 Byte, Default Value: 0
SettingDescription
0 | minutes |
---|---|
1 | seconds |
2 | hours |
Parameter 17: EP2 Auto Turn-Off Timer Unit
Setting auto off timer unit(minutes, seconds or hours) for relay two
Size: 1 Byte, Default Value: 0
SettingDescription
0 | minutes |
---|---|
1 | seconds |
2 | hours |
Parameter 18: EP2 Auto Turn-ON Timer Unit
Setting auto on timer unit(minutes, seconds or hours) for relay two
Size: 1 Byte, Default Value: 0
SettingDescription
0 | minutes |
---|---|
1 | seconds |
2 | hours |
Parameter 2: Select switch one’s type
Select switch one’s type: switch or sensor
Size: 1 Byte, Default Value: 2
SettingDescription
0 | momentary switch |
---|---|
1 | toggle switch (contact closed -ON, contact opened – OFF) |
2 | toggle switch (device changes status when switch changes status) |
3 | garage door mode(toggle switch type for external switch (like in value 1) + |
built-in 2 second auto-off timer for Z-Wave control (so if user turns the
relay on from the Z-Wave hub, it will automatically turn off after 2 seconds)
4| water alarm
5| heat alarm
6| Smoke alarm
7| Door alarm
8| CO alarm
9| CO2 alarm
Parameter 24: Sw1,Sw2 setting
DC motor mode: sync R1 and R2 together to prevent them from being activated
at the same time
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Normal |
---|---|
1 | Union (only switch type1 < 4 && switch type2 < 4) IF both switches OFF – |
only one of them may be turned ON. – turning sw1 ON : delayed 0.5 s, sw2 and R2 turned off first (immediately) – turning sw2 ON – delayed 0.5s , sw1and R1 turned off first ( immediately ) The situation for DC motor control(SW1 controlright, SW2 control-left. -main switch can turn ON and OFF only sw1
Parameter 3: Select switch two’s type
Select switch two’s type: switch or sensor
Size: 1 Byte, Default Value: 2
SettingDescription
0 | momentary switch |
---|---|
1 | toggle switch (contact closed -ON, contact opened – OFF) |
2 | toggle switch (device changes status when switch changes status) |
3 | garage door mode(toggle switch type for external switch (like in value 1) + |
built-in 2 second auto-off timer for Z-Wave control (so if user turns the
relay on from the Z-Wave hub, it will automatically turn off after 2 seconds)
4| water alarm
5| heat alarm
6| Smoke alarm
7| Door alarm
8| CO alarm
9| CO2 alarm
Parameter 5: LED indicator
Indicator inverse, follow, always on or always off
Size: 1 Byte, Default Value: 0
SettingDescription
0 | LED on when relay off, LED off when relay on |
---|---|
1 | LED on when relay on, LED off when relay off |
2 | LED Always OFF |
3 | LED Always ON |
Parameter 6: EP1 Auto Turn-off Timer
Setting auto off timer value for relay one
Size: 4 Byte, Default Value: 0
SettingDescription
0 – 65535 | EP1 Auto Turn-off Timer |
---|
Parameter 7: EP1 Auto Turn-on Timer
Setting auto on timer value for relay one
Size: 4 Byte, Default Value: 0
SettingDescription
0 – 65535 | EP1 Auto Turn-on Timer |
---|
Parameter 8: EP2 Auto Turn-off Timer
Setting auto off timer value for relay two
Size: 4 Byte, Default Value: 0
SettingDescription
0 – 65535 | EP2 Auto Turn-off Timer |
---|
Parameter 9: EP2 Auto Turn-on Timer
Setting auto on timer value for relay two
Size: 4 Byte, Default Value: 0
SettingDescription
0 – 65535 | EP2 Auto Turn-on Timer |
---|
Technical Data
Hardware Platform | ZGM130 |
---|---|
Device Type | Binary Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 7.13.6 |
Certification ID | ZC12-21020174 |
Z-Wave Product Id | 0x0312.0xBB00.0xBB0A |
Firmware Updatable | Updatable by Consumer by RF |
Switch Type | Push Button |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info V3
- Association V3
- Basic V2
- Configuration V4
- Device Reset Locally
- Firmware Update Md V5
- Indicator V3
- Manufacturer Specific V2
- Multi Channel Association V4
- Multi Channel V4
- Notification V8
- Powerlevel
- Security 2
- Sensor Binary V2
- Supervision
- Switch Binary V2
- Transport Service V2
- Version V3
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)