T D TR-7NW Series Thermo Recorder User Manual
- June 6, 2024
- T D
Table of Contents
T D TR-7NW Series Thermo Recorder User Manual
In this document, TR-71nw, TR-72nw, TR-72nw-S and TR-75nw are collectively referred to as the “TR-7nw Series” or simply as the “device” or “logger”.
T&D Web Storage Service
T&D WebStorage Service is a free cloud-based storage service provided by T&D Corporation, which enables you to access the uploaded recorded data from a web browser and check the current readings, remaining battery life of the device, and alert status. You can also receive warning notifications by email. In order to use the T&D WebStorage Service, user registration (free) and device registration are required.
Important Notes
- Before registering as a user, please read [Service Details / License Agreement] for information on service contents and specifications, including the data storage period in the T&D WebStorage Service.
- The registration code of the device can be found on the supplied Registration Code Label. If you lose the code label, install the software TR7 for Windows and connect your logger via USB to the computer. The registration code and device information will be displayed at the lower-left area of the screen.
- When the storage period in T&D WebStorage Service is exceeded, old data will be deleted.
User and Device Registration Procedures
- Access T&D WebStorage Service from the web browser. www.webstorage-service.com
- Click [Create Account] to go to the registration page, and follow the directions to complete the registration.
- Login by entering the registered User ID and Password.
- Click [Devices] in the left menu to open the Device Settings window.
- Clicking the [+Device] button will take you to the Add a Device page.
- Enter the serial number and registration code for the device, then click [Add].
Common Operations
Recording Interval Setting
Install the batteries and sensor(s) in the logger, and make sure the LCD is displaying measurements. The factory default setting for the recording interval is 10 minutes for TR-75nw and 1 minute for TR-71nw/TR-72nw. Follow the procedure below to change this setting.
- Skip this setting if you don’t need to change the recording interval.
- Upon the start of recording, all previously recorded data in the logger will be deleted.
- Note: When is ON (recording in progress), the logger cannot be turned off , nor can the recording interval be changed.
-
When is ON, press-and-hold the <REC/STOP> button until turns OFF (recording stops).
-
Press the
button. -
While is displayed, press-and-hold the
button until the interval time flashes. -
Press
again to select the interval time. Each press changes the interval as follows:
Recording Intervals ( ) 1, 2, 5, 10, 15, 20, 30 SEC / 1, 2, 5, 10, 15, 20, 30, 60 MIN -
When you stop pressing the button, the display will return to the normal measurement mode, confi rming that it is set.
-
Start recording by pressing and holding the <REC/STOP> button until the mark appears in the display.
In order to stop a recording session, press and hold the <REC/STOP> button
until the
mark disappears from the display.
Details about the LCD Display
Other than the measurement display, the following is displayed on the LCD monitor.
Messages on LCD Screen
Thermocouple Sensor Type (TR-75nw only)
By pressing and holding the
Operations via Cloud
Auto-upload settings enable this product to automatically upload data to T&D WebStorage Service. Please read the T&D WebStorage Service License Agreement carefully before making settings.
- Making Auto-upload Settings indicates your acceptance of this Agreement.
STEP 1: Making Auto-Upload Settings
By making settings for auto-upload, it is possible to automatically upload recorded data to the online “T&D Web Storage Service”.
In the auto-upload, the maximum number of readings which can be stored in “T&D WebStorage Service” is 80,000. When this limit is exceeded, the oldest data will be overwritten and deleted.
-
Connect a LAN cable to the Ethernet port.
If you wish to use a static IP address instead of DHCP, change the network settings on our software “TR7 for Windows” by connecting the device to a PC via USB. For details about operations please see the “Help” menu in the software. -
Click the
button twice to display the current upload interval. -
Press the
button until the display flashes. -
With each pressing of the
button the upload interval time will change. When the desired interval appears, stop pressing the button.
If you wish NOT to use the auto-upload feature, select “OFF”. Within a few seconds, the display will return to measurement mode to indicate the upload interval is set.
Below are some examples of upload intervals and the corresponding estimated
battery life.
In general, the shorter the upload interval, the shorter the battery life.
- All estimates are based on operations carried out with a new battery and are in no way a guarantee of actual battery life.
- The auto-upload interval can also be changed during a recording session.
STEP 2: Installing the Device
Install the device to the actual place it will be used.
STEP 3: Checking Recorded Data
- Access “T&D Web Storage Service” from the web browser on your PC or mobile device. www.webstorage-service.com
- Click [Create Account] to go to the registration page, and follow the directions to complete the registration. If you already have your User ID, go to the next step.
- Login by entering the registered User ID and Password.
- In the [Device Settings] window click [+Device].
- In the Add a Device page, enter necessary information* and click [Add].
- After data is sent to “T&D WebStorage Service” either by auto-upload or by pressing the <REC/STOP> button on the logger, the added device and its measurements will appear in the [Data View] window.
- The registration code can be found on the supplied Registration Code Label.
If measurements are not displayed:
-
Check the device screen to make sure is ON. Recorded data will not be uploaded
when recording is not in progress. -
Try sending data to “T&D WebStorage Service” again by pressing the <REC/STOP>
button on the device. -
See “Checking Connection Status” in step 2, and check if the device has a LAN connection.
If the display of measurements is not refreshed:
We recommend making the recording interval shorter than the auto-upload
interval. If the recording interval is set to longer than the upload interval,
the same measurement is displayed until the next recording occurs and the new
data is uploaded.
If you cannot find the registration code:
See [T&D WebStorage Service] – [important Notes] on the left side of this
paper.
Viewing Data from other than a Web Browser
Recorded data sent to “T&D Web Storage Service” can be accessed, viewed and downloaded directly from “T&D Thermo” and “T&D Graph” as well as from a web browser.
-
Here explains how to view data from “T&D Graph”. For information about “T&D Thermo”,
see [Operations via Mobile APP] on the back of this manual.- Download and install the software T&D Graph from T&D Website. tandd.com/software/td-graph.html
- From the [File] Menu, select [Web Storage Service].
- Enter the User ID and Password registered with T&D WebStorage Service, and click [Login]. Upon successful login, the recorded data of the devices registered with your account will be displayed.
- Double click on the recorded data you wish to view in a graph. The data will be downloaded and displayed in a graph.
STEP 4: Changing the Settings
By using the “T&D WebStorage Service”, it is possible to change the following settings.
Device Information:
Device Name, Group Name, Recording Interval, Recording Mode, Auto-upload
Interval, Channel Name, Time Settings, Temperature Unit
Warning Settings:
Lower Limit, Upper Limit, Sensor Warning, Judgement Time
The changes in settings will be applied when the device communicates with the “T&D WebStorage Service”. To apply the changes immediately, press the <REC/STOP> button on the device after settings are completed.
Operations via Mobile APP
STEP 1: ”T &D Thermo” App Settings
- Install “T&D Thermo” to your smartphone or tablet.
- “T&D Thermo” is available on the Apple Store for iOS devices and the Google Play Store for Android devices. 2. Search for “T&D Thermo” on the Apple Store for iOS devices and the Google Play Store for Android devices. 3. Open “T&D Thermo”. 4. Tap the menu icon in the upper left corner of the screen, and tap [App Settings]. 5. Tap [Account Management] for T&D WebStorage Service. 6. Enter the User ID and Password for your account, and tap [Apply].
- If you added more than one account, select the account you want to access. 7. Tap to return to the top screen.
STEP 2: Graph Display and Device Settings
- .From the list on the top screen, tap the device registered with T&D WebStorage Service to open the Device Info screen.
- Tap [WebStorage] at the bottom of the screen.
This will access the logger via T&D WebStorage Service and open the Graph/Device Settings screen.
Graph Operations
Device Settings
You can view or make changes to the settings such as Rec Settings, Name
Settings, Warning Settings and Auto-upload Interval.
Changed settings will be applied the next time the device connects to the T&D WebStorage Service.
STEP 3: Saving and Sharing Recorded Data
T &D Data Server
“T&D Data Server” is a Windows software that receives and stores data recorded
by TR-7nw Series data loggers to the server’s database. It is possible to
monitor current readings and warnings via a web browser. When you wish to have
recorded data automatically uploaded to your server rather than T&D WebStorage
Service, please use “T&D Data Server”. tandd.com/software/td-data-
server.html
- Install T&D Data Server on the computer to be used as a server, and open the [T&D Data Server Manager] window.
- Enter the Server Address and Port Number.
-
The IP address(es) for the server PC will automatically appear. If there are multiple
networks, select the IP address for the network waiting for a connection. -
The default Port Number is 80.
-
The settings cannot be changed while the server function is running. Please click the
[OFF] button to stop the server function.- Place a check next to “Do not allow the computer to enter sleep mode.”
- Click the [ON] button.
-
If Windows goes in “Standby” or “Sleep” mode, reception of recorded data and monitoring can not be carried out.
-
The IP address and port number set here will be used in the Windows software
“TR7 for Windows” as the data destination in the Auto-upload Settings. For details about operations of “TR7 for Windows” , please refer to the software’ s Help.
Monitoring
To open the monitoring window, open your web browser, and in the address bar
enter the server address set in Data Server Settings.
Graph View
In the monitoring window, click the desired device name to view the data in
graph form.
For details about the operations of T&D Data Server, refer to
cdn.tandd.co.jp/glb/html_help/tddataserver-help-
eng/
Operations via USB
It is possible to make device settings and download recorded data by using the software “TR7 for Windows”. Data downloaded can then be viewed in a graph for analysis by using our software “T&D Graph”.
Primary features of “TR7 for Windows” include :
- Start/Stop Recording
- Auto-upload Setting
- Network Settings (static IP address, etc.)
- Name Settings (device/group/channel)
- Downloading and Saving Recorded Data
- Warning Settings
- Time Settings
- Sensor Type Setting (TR-75nw only)
- Report Creation and Output
- Settings and Log Output
STEP 1: Setting Up
-
Download and install the software “TR7 for Windows” and “T&D Graph“ from T&D Website.
tandd.com/software/tr7forwin.html
tandd.com/software/td-graph.html -
Connect the logger via USB to your computer. * “TR7 for Windows” will open automatically. (If not, please open it manually from
the Windows Start Menu or Start Screen.)
- For details about operations please see the “Help” menu in the software. 3. After the setup is complete, place the device to the desired measurement location.
STEP 2: Downloading Recorded Data
- Connect the logger via USB to your computer.
- Open “TR7 for Windows”, click the [Download Recorded Data] tab and proceed with the download.
[Detailed Settings] allow you to :
- View and change the “Graph Display” and “File Name” settings
- Select whether to create a report (PDF/CSV) with daily maximum and minimum values and
total time out of threshold, etc.
For details about the operations of TR7 for Windows, refer to
cdn.tandd.co.jp/glb/html_help/tr7win-help-
eng/
STEP 3: Viewing Recorded Data in Graph
- Open “T&D Graph” and then access the data you wish to view.
- Upon completion of the download, “T&D Graph” will open and display the graph.
For details about the operations of T&D Graph, refer to
cdn.tandd.co.jp/glb/html_help/tdgraph-help-eng/
Device Button Operations
1. “Press-and-hold” means to hold the button down for about two seconds. During recording, the power cannot be turned off.
2. Upon the start of recording, all previously recorded data in the unit will be deleted.
*3. Recording Interval setting cannot be changed while a recording session is in progress.
Before performing button operations, please read the attached document [Please Read First] and install the batteries and sensor(s) in the logger, and make sure the LCD is displaying measurements.
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>