Precautions for Safe Use

Please observe the following precautions for the safe use of the products.

  1. Tighten the screws within the following tightening torque range. If the tightening torque is too large, the parts may be damaged. If it is too small, the parts may come off due to vibration or impact.
    M3: 0.4 to 0.5 N·m
    M5: 3.0 to 3.5 N·m

Precautions for Correct Use

  1. Do not use the product under the following conditions.
    •In the place exposed to direct sunlight.
    •In the place where corrosive gas exists.
    •In the place where vibration or shock is directly transmitted to the product.
    •In an ambient atmosphere or environment that exceeds the ratings.

  2. Use the supplied screws for installation.

Ratings and Specifications

Mounting angle 360° horizontal, 360° vertical
Ambient temperature (Operating) -25 to 55°C
Ambient temperature (Storage) -40 to 70°C
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in

X, Y, and Z directions
Shock resistance| 500 m/s2 3 times each in X, Y, and Z directions
Material| Clamp: ZDC2 Ni plating, Bracket: SUS 304
Post’s 1| 12 dia.
Applicable sensor| E3AS-F, E3AS-L, E3AS-HL, E3Z, E3ZR, E3ZM

*1. Applicable posts (E39-L262 and E39-L263) are sold separately.

Accessories

Contents

| Material|

Qty

---|---|---
Hexagon socket head cap screw M5 x 15| SUS| 1
Hexagon nut M5| SUS| 1
Fixing screw M3 x 10 (with spring and plain washers)| SUS| 2

Contents

E39-L261 (this product)

|

E39-L262/E39-L263 (sold separately)

---|---
OMRON E39-L261 Flexible Mounting Bracket for Photoelectric Sensor -
Contents| OMRON E39-L261 Flexible Mounting Bracket for Photoelectric Sensor -
Contents1

Installation

Installation procedure

  1. Mount the sensor to the bracket with the M3 screws.
  2. Attach the clamp to the post (sold separately).
  3. Fit the sensor bracket into the groove on the clamp tip.
  4. Secure the clamp with bolt M5 with hexagonal hole and M5 hexagon nut.
  5. Use M12 nuts and M12 plain washers (sold separately) to attach the post to the equipment.

OMRON E39-L261 Flexible Mounting Bracket for Photoelectric Sensor -
fig Final drawing

Suitability for Use

OMRON Corporation shall not be responsible for conformity with any standards, codes, or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use that apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use.
Buyer shall be solely responsible for determining the appropriateness of the particular Product with respect to Buyer’s application, product, or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

OMRON logo OMRON Corporation
Industrial Automation Company
Contact: www.ia.omron.com
Kyoto, JAPAN
Regional Headquarters

OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787

|

OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
Pudong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200

---|---

© OMRON Corporation 2020 All Rights Reserved.OMRON E39-L261 Flexible
Mounting Bracket for Photoelectric Sensor - barcode

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals