Miele Vented Dryer PDR 908 EL Instruction Manual
- June 6, 2024
- Miele
Table of Contents
Miele Vented Dryer PDR 908 EL Instruction Manual
Legend:
Connection required
- AL: Exhaust air
- ASK: Condensate drain hose
- B: Machine anchoring
- EL: Electrical connection
- F: Machine feet, adjustable
- KG: Payment system
- KGA: Payment system connection
- KLA: Cooling air vent
Connection optional or required, depending on model
- KLZ: Cooling air intake
- PA: Potential equalization
- SLA: Peak-load connection
- UG: Closed base
- UO: Open base
- APCL: Washer-dryer stacking kit
- XKM: Communication module
- ZL: Air intake
Machine dimensions
Installation
Washer-dryer stack
Technical data
Drying system | – | Vented |
---|---|---|
Drum volume | l | 130 (4.59 ft3) |
Capacity | kg | 8.0 (17.6 lb) |
Door opening diameter | mm | 370 (17 9/16 in) |
Electrical connection ( EL)
Standard voltage for CDN & USA| –| 2 AC 208-240 V
Frequency| Hz| 60
Total rated load| kW| 3.2/4.3
Fuse rating| A| 2 x 30
Supply cable min. cross-section| | 3 x AWG10
Supply cable with plug type NEMA L6-30P| | ●
Length of supply cable| mm| 1,830 (6.0 ft)
Non-standard voltage MAR 208-240 (Marine)| –| 2 AC 208-240 V
Frequency| Hz| 60
Total rated load| kW| 3.2/4.3
Fuse rating| A| 2 x 30
Supply cable min. cross-section| | 3 x AWG10
Supply cable with plug type NEMA L6-30P| | ●
Length of supply cable| mm| 1,830 (6.0 ft)
Vented ( EL)
Connection (ext. diameter)| mm| 100 (3 15/16 in)
Max. exhaust air temperature| °C| 80 (176°F)
| |
Electrical connection with 50 Hz/60 Hz| |
Max. permissible pressure loss| Pa| 340 (0.049 psi)
Max. flow rate w/o counterpressure (0 Pa) in vented mode| m³/h| 285 (10.064
ft3/h)
Potential equalization ( PA)
Appliance connection (with installation kit)| |
| |
XCI box interface| | ●
Peak load/ energy management ( SLA)
Machine connection (with XCI box)| |
Communication module ( XKM) ●
Communication module XKM 3200 WL PLT| |
Installation on machine feet ( F)
No. of machine feet| No.| 4
Machine foot, height-adjustable with thread| mm| ± 5 (3/16 in)
Machine foot diameter| mm| 31.7 (1 1/4 in)
Anchoring ( B)
Anchoring of Miele bases
Miele base installation (fasteners included)| | Ο
Required anchor points| No.| 4
Wood screws according to DIN 571| mm| 8 x 65
(5/16 x 2 9/16 in)
Rawl plugs (diameter x length)| mm| 12 x 60 (1/2 x 2 3/8 in)
Base floor anchoring (to be provided on site)
Machine installation on on-site base(concrete or masonry)| | Ο
Min. base installation footprint (W/D)| mm| 600/650 (23 5/8 x 25 9/16 in)
Wood screws according to DIN 571| mm| 6 x 50 (1/4 x 2 in)
Rawl plugs (diameter x length)| mm| 8 x 40 (5/16 x 1 9/16 in)
Machine data
Overall machine dimensions (H/W/D)| mm| 850/605/717 (33 7/16 / 23 13/16 / 28
1/4 in)
Casing dimensions (H/W/D)| mm| 850/596/677
(33 7/16 / 23 7/16 / 26 5/8 in)
Site-access dimensions (H/W)
Min. site-access opening (excl. packaging)| mm| 900/605 (35 7/16 / 23 13/16
in)
Installation dimensions
Min. side gap| mm| 20 (13/16 in)
Recommended side gap – washer-dryer stack| mm| 300 (11 13/16 in)
Min. distance to opposite wall from front of machine| mm| 950 (37 3/8 in)
Recommended distance to opposite wall from front of machine| mm| 1,100 (43
5/16 in)
Weights and floor loads
Machine weight (net weight)| kg| 51.5 (113.6 lb)
Max. floor load in operation| N| 670
Emissions
Sound pressure level (in accordance with EN ISO 11204/11203)| dB(A)| < 70
Heat dissipation rate to installation site| W| 200
Installation and planning notes
Installation requirements
The tumble dryer should only be connected to a power supply provided in accordance with all appropriate local and national legislation and regulations.
In addition, all regulations issued by the appropriate utilities as well as standards relating to occupational safety and all applicable valid regulations and technical standards must be observed.
General operating conditions
Ambient temperature in installation room: +2°C to +35°C (36°F to 95°F).
Electrical connection
This tumble dryer is supplied with a power cord and plug ready for connection.
The machine may only be connected to an electrical system that conforms to the national and local codes and regulations. The installation must be performed by a qualified electrician.
The data plate indicates the nominal power consumption and the appropriate fuse rating. Compare the specifications on the data plate with those of the electrical power supply
The tumble dryer can either be hard-wired or connected using a plugand-socket connection in accordance with IEC 60309-1. It is always recommended to connect the machine via a plug and socket so that electrical safety checks, e.g. during repair or service work, can be carried out easily.
If the machine is hard-wired, a dual circuit breaker must be provided on site. When switched off, there must be an all-pole contact gap of at least 3 mm in the isolator switch (including circuit breakers, breakers, and relays according to IEC/EN 60947).
The plug connector or isolator switch should be easily accessible at all times. If the tumble dryer is disconnected from the electricity supply, the isolator must be lockable or the point of disconnection must be monitored at all times.
New connections, modifications to the system, or servicing of the ground conductor, including determining the correct fuse amperage, must be carried out by a qualified electrician, as they are familiar with the pertinent regulations and the specific requirements of the electric utility company.
If converting the tumble dryer to an alternative voltage, observe the instructions in the wiring diagram. Conversion must be performed by Miele Service or by an authorized Miele dealer. The heater rating must also be adapted.
The tumble dryer must not be connected to devices such as timers which would switch it off automatically.
References to cable cross-sections in the technical data refer only to the required power cord. Please consult relevant local and national regulations when calculating any other wire gauges.
Vent connection
Hot moist exhaust air should be vented to atmosphere along the shortest possible route or connected to a suitable vent system.
Depending on the duct path, the moist exhaust air can condense on the duct
walls to a greater or lesser extent. For this reason it is recommended to lay
ducting with a downwards slope to the air exit.
If ducting slopes upwards, a condensate trap either with a drip tray or a
connection to a suitable on-site floor drain must be fitted in the system at
the lowest point.
Condensate must not flow back into the machine.
It is permissible to vent exhaust air via an external wall. In this case, measures must be taken to minimize the risk and annoyance to neigh bouring buildings.
The end of exhaust air ducting leading into the open should be protected against the elements, e.g. using a suitable hood or grille or with a 90° bend.
The cross-sectional area of the ducting must not be reduced or obstructed by built-in parts. Filters and louvers must not be fitted in the ducting.
Congestion in the line may lead to a drop in machine performance or to machines being switched off to guarantee safety.
Proper functioning of the tumble dryer cannot be guaranteed if the max. permissible pressure loss is exceeded in the on-site vent ducting system.
When connecting several tumble dryers to a common duct, the crosssectional area of the duct must be increased accordingly.
Additionally, in such a case every tumble dryer must have its own non-return valve to prevent dryers affecting others in the system. This requires the provision of on-site additional parts.
In the event that exhaust air ducts from several tumble dryers are merged into a common duct, a non-return device should be installed in each separate line to prevent backflow.
With complex ducting with many bends and additional components, or with the connection of several different machines to a common duct, it is recommended that a detailed calculation is carried out by a suitable specialist.
Air intake
The air supply for the tumble dryer is taken directly from the installation site.
During operation, adequate ventilation of the installation site should be guaranteed. Depending on the machine version, it is necessary to ensure an intake of fresh air to compensate for the volume of exhaust air extracted in order to avoid the creation of a vacuum
It should not be possible to close or otherwise obstruct air intake grilles or alternative measures should be implemented to ensure that an adequate supply of fresh air is available at all times during tumble dryer operation.
Potential equalization
If necessary, potential equalization with good galvanic contact must be guaranteed in compliance with all applicable local and national installation specifications
Connection material for potential equalization must be provided on site or using a kit available from Miele Service.
Peak load/Energy management
The machine can be connected to a peak load or energy management system using an optional kit.
When the peak-load function is activated, the heating is deactivated.
A message appears in the display to inform you of this.
Interface
The tumble dryer can be retrofitted with an XKM 3200 WL PLT communication module.
This module can be used as a WiFi or LAN interface.
The LAN interface provided via the module complies with SELV (Safety Extra Low Voltage) in accordance with EN 60950. Connected appliances must also comply with SELV. The LAN connection uses a RJ45 connector in accordance with EIA/TIA 568-B.
Installation and anchoring
The machine must be installed on a perfectly smooth, level and firm surface which is able to withstand the quoted loads.
The floor load created by themachine is concentrated and transferred to the installation footprint via the machine feet.
The tumble dryer should be levelled in both directions with the aid of the adjustable feet.
Base installation
The tumble dryer can be installed on a machine base (open or box base, available as an optional Miele accessory) or on a concrete base to be provided on site.
The quality of the concrete and its strength must be assessed according to the machine load. Ensure that any raised concrete base is adequately bonded to the floor below.
Washer-dryer stack
The tumble dryer can be installed as a washer-dryer stack together with a Miele Washing Machine. A stacking kit (optional accessory) is required for this.
Installation of the stacking kit must be performed by Miele Service or an authorized Miele service technician.
Read User Manual Online (PDF format)