DRUMMOND 63323 1/2 HP Submersible Sewage Pump Owner’s Manual
- June 6, 2024
- DRUMMOND
Table of Contents
Owner’s Manual & Safety Instructions
1/2 HP SUBMERSIBLE SEWAGE PUMP
63323
Save This Manual Keep this manual for the safety warnings and precautions,
assembly, operating, inspection, maintenance, and cleaning procedures. Write
the product’s serial number in the back of the manual near the assembly
diagram (or month and year of purchase if the product has no number).
Keep this manual and the receipt in a safe and dry place for future reference.
21e
Do not return the pump to the store.
Call 1-844-416-9141
Visit our website at : http://www.harborfreight.com
Email our technical support at:
productsupport@harborfreight.com
When unpacking, make sure that the product is intact and undamaged. If any
parts are missing or broken, please call
1-888-866-5797 as soon as possible.
©Copyright 2020 by Harbor Freight Tools®.
All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, the actual product may differ slightly from the product
described herein.
Tools required for assembly and service may not be included.
WARNING
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.
Before start-up, note the following:
The pump must be connected to a GFCI protected plug which has been installed
according to regulations. The plug must have a supply voltage of 120 VAC at 60
Hz.
CAUTION
This pump has been evaluated for use with water only.
WARNING
IMPORTANT! For your own safety –before starting to run the pump, please
have the following items checked by an expert:
- Risk of electric shock – This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
- Risk of electric shock – This pump has not been investigated for use in swimming pool areas.
- The electrical connections must be protected from moisture.
- If there is a danger of flooding, the electrical connections must be taken to higher ground.
- Circulation of caustic fluids, as well as the circulation of abrasive materials, must be avoided at all costs.
- The pump must be protected from frost.
- The pump must be protected from running dry.
- Access by children should also be prevented with appropriate measures.
- To prevent death from electric shock, the pump must be connected only to a GFCI protected outlet.
- Do not use an extension cord with this item.
- People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to the heart pacemakers could cause pacemaker interference or pacemaker failure.
- The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur.
It must be understood by the operator that common sense and caution are factors that cannot be built into this product but must be supplied by the operator.
Fluid Type
The Pump is designed for use with water with a maximum temperature of 131° F
(55°C).
Do not use the pump for other fluids, especially not fuels, cleaning fluids,
or other chemical products.
Specifications
Electrical Rating | 120VAC / 60Hz / 7.4A |
---|---|
Power Cord Length | 10’ |
Maximum Flow @ 0’ | 6000 GPH |
Maximum Head lift @ 0 Flow | 18′ |
Discharge Port1 | 2″ NPT Thread |
For technical questions, please call
1-888-866-5797.
Item 63323
Installation
The submersible motor pump must be installed in a stationary position with
either:
a. A fixed pipeline or
b. A flexible hose pipe.
Please note!
-
Do not install the pump by suspending it unsupported from its delivery pipe or power cord.
The pump must be suspended from the handle or be placed on the bottom of the basin.
To ensure that the pump works properly, keep the bottom of the basin free from sludge and dirt of all kinds. -
If the water level sinks too low, any sludge in the basin will dry out and stop the pump from starting.
To help ensure the pump will start as required, check the pump regularly with start-up tests.
Power Supply
- The pump is equipped with a shock-proof plug according to regulations. The pump is designed to be connected to a 120 VAC, 60 Hz GFCI protected socket.
- Make sure that the socket is sufficiently secured and is in excellent condition.
- When the plug is inserted into the socket, the pump will be on standby.
- WARNING: To prevent death from electric shock, the pump must be connected only to a GFCI protected outlet.
WARNING! TO PREVENT SERIOUS INJURY:
If the power cord or plug is damaged, do not use the pump. The power cord or
plug may only be repaired by a certified electrician.
Areas of use
-
This pump is designed to be used for:
Pumping domestic sewage, effluent, wastewater, groundwater, and other nonexplosive, noncorrosive liquids with up to 2″ diameter solids to a gravity- fed sewage line -
This pump should NOT be used for:
Installation Instructions
-
Construct a basin that is at least 30″ deep and at least 18″ in diameter.
-
Position Pump on a solid surface so that both hoses are free from kinks the Float Switch is away from the inlet pipe and at least 1″ away from all obstructions throughout its movement.
-
Fit a sewage cover with a vent pipe, a hole for the output pipe, and a hole for the power cords. Thread the Power Cords through their holes, but do not plug them in yet. Set the sewage cover aside for now. Place the unused end of the discharge hose on the other end
Note: The sewage cover must also be fitted with a vent pipe.
-
Attach a discharge pipe to the Pump Outlet.
Note: Wrap all threaded connections with PTFE thread seal tape. -
Check Valve is sold separately. Install according to manufacturer instructions.
-
To prevent excessive cycling from the backflow of water, install a check valve onto the discharge pipe. This prevents water from flowing back after the pump shuts off. Mount the check valve according to the check valve label to avoid the valve flapper getting stuck.
IMPORTANT: Drill a 1 /8″ diameter air bleed hole through the Discharge Pipe just above the lower Base to prevent Pump ″airlock″. A small spray of water out of this ole is normal while the Pump is running. -
Connect additional Discharge Pipe as needed to direct the discharge to the main waste line for the sewer or septic tank. The discharge should be kept as short as possible with a minimum number of turns.
IMPORTANT: Do not exceed the Maximum Head Lift @ 0 Flow of the Pump.
Operation
After reading these instructions, consider the following points before starting the pump:
- Verify that the pump rests on the floor of the basin.
- Verify that the discharge pipe is properly connected.
- Verify that the electrical connection is 120 VAC, 60 Hz.
- Verify that the electrical socket is GFCI protected and in good condition. Test GFCI protected outlet before use.
- Verify that water and moisture cannot get near the power supply socket.
- Verify that the pump is installed so as to prevent running dry.
Maintenance
WARNING
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Unplug the Pump from its electrical outlet before performing any
inspection, maintenance, or cleaning procedures.
If the pump is moved during operation, flush it out with clean water after
every use.
Quarterly Maintenance
The below maintenance must be performed at least once every 3 months under
optimal conditions.
For frequent use, or dirty areas, more frequent maintenance is required.
- Clean sludge and debris from the bottom of the basin.
- Clean sludge/debris from the inlet screen.
- Make sure the discharge pipe is free from leaks.
- Make sure the check valve is functioning properly.
- Manually operate flow switch to determine that pump turns on/off as intended.
Troubleshooting
Problem| Possible Causes|
Possible Solutions
---|---|---
The pump runs, but will not deliver any water.| Disconnect power cords
immediately to prevent damage from running dry.
- Pump “airlock”. The impeller is trapped in an air bubble.
- Shut off valve closed (if installed).
- Impeller clogged.
- Discharge Pipe froze or blocked.
- Low line voltage.
- Check valve (sold separately) stuck or installed backward.
| Disconnect power cords immediately to prevent damage from running
dry.
- Drill a 1/8″ diameter air bleed hole through the Discharge Pipe just above the lower Base. Make sure the air bleed hole is clear.
- Open valve.
- Clean out dirt and debris from the impeller.
- Thaw pipe and/or remove debris.
- Consult an electrician.
- Remove and examine check valve.
The pump won’t start or run.|
- Check power connections and circuits/fuses.
- Float Switch failed.
- Impeller clogged.
- Defective motor.
|
- Consult an electrician.
- Replace Float Switch.
- Clean out dirt and debris from the impeller.
- Have a qualified service technician repair or replace.
Excessive noise or vibration.|
- Worn bearings.
- Debris in the impeller.
- Discharge pipe restricted.
|
- Have a qualified service technician repair or replace.
- Clean impeller.
- Clean Pump and discharge pipe. Straighten flexible hose.
The pump starts and stops too frequently.|
- Water temperature too high.
- Check valve (sold separately) stuck or installed backward.
- Backflow of water from the discharge hose.
|
- Do not exceed the 131° F (55°C) water temperature.
- Remove and examine check valve.
- Install or inspect check valve (sold separately).
The pump does not shut off automatically| DISCONNECT POWER CORDS FIRST TO PREVENT ACCIDENTAL STARTING.
- Float Switch stuck.
- Check valve not installed properly or functioning.
- Defective electrical switch.
| DISCONNECT POWER CORDS FIRST TO PREVENT ACCIDENTAL STARTING.
- Check for free movement of Float Switch. Clear debris away from beneath Float Switch.
- Make sure the check valve is properly installed and in working order.
- Unplug the Pump from its electrical outlet. Do not use until qualified technician checks Pump for damage.
Follow all safety precautions whenever diagnosing or servicing the tool. Disconnect power supply before service.
Parts List and Diagram
PLEASE READ THE FOLLOWING CAREFULLY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY
DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER NOR
DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER
THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR
SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE
MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS
REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND
NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY
ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS
THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS
THERETO.
Parts List
Part | Description | Qty. |
---|---|---|
1 | Pump Cord | 1 |
2 | Handle | 1 |
3 | Float Switch Cord | 1 |
4 | Motor | 1 |
5 | Screw | 4 |
6 | Float Switch | 1 |
7 | Shaft | 1 |
8 | Impeller | 1 |
9 | Gasket | 1 |
10 | Volute | 1 |
Record Product’s Serial Number Here:
Note: If the product has no serial number, record the month and year of
purchase instead.
Note: Some parts are listed and shown for illustration purposes only, and
are not available individually as replacement parts. Specify UPC 792363633239
when ordering parts.
Assembly Diagram
Limited 90 Day Warranty
Harbor Freight Tools Co. makes every effort to assure that its products meet
high quality and durability standards, and warrants to the original purchaser
that this product is free from defects in materials and workmanship for the
period of 90 days from the date of purchase. This warranty does not apply to
damage due directly or indirectly, to misuse, abuse, negligence or accidents,
repairs or alterations outside our facilities, criminal activity, improper
installation, normal wear, and tear, or to lack of maintenance. We shall in no
event be liable for death, injuries to persons or property, or for incidental,
contingent, special or consequential damages arising from the use of our
product. Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to
you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.
To take advantage of this warranty, the product or part must be returned to us
with transportation charges prepaid. Proof of purchase date and an explanation
of the complaint must accompany the merchandise.
If our inspection verifies the defect, we will either repair or replace the
product at our election or we may elect to refund the purchase price if we
cannot readily and quickly provide you with a replacement. We will return
repaired products at our expense, but if we determine there is no defect, or
that the defect resulted from causes not within the scope of our warranty,
then you must bear the cost of returning the product.
This warranty gives you specific legal rights and you may also have other
rights which vary from state to state.
26541 Agoura Road
Calabasas, CA 91302
1-888-866-5797
Read User Manual Online (PDF format)