DRUMMOND 63319 Submersible Shallow Well Utility Pump Owner’s Manual
- June 6, 2024
- DRUMMOND
Table of Contents
Owner’s Manual & Safety Instructions
1/3 / 1/G HP
SUBMERSIBLE SHALLOW WELL UTILITY PUMP
Save This Manual Keep this manual for the safety warnings and
precautions, assembly, operating, inspection, maintenance, and cleaning
procedures. Write the product’s serial number in the back of the manual near
the assembly diagram (or month and year of purchase if the product has no
number).
Keep this manual and the receipt in a safe and dry place for future reference.
21e
Do not return the pump to the store.
Call 1-844-416-9141
6331863319
Visit our website at :
http://www.harborfreight.com
Email our technical support at:
productsupport@harborfreight.com
When unpacking, make sure that the product is intact and undamaged. If any
parts are missing or broken, please call
1-888-866-5797 as soon as possible.
©Copyright 2020 by Harbor Freight Tools®.
All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, the actual product may differ slightly from the product
described herein.
Tools required for assembly and service may not be included.
WARNING
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.
Before start-up, note the following:
The pump must be connected to a GFCI protected plug which has been installed
according to regulations. The plug must have a supply voltage of 120 VAC at 60
Hz.
CAUTION
This pump has been evaluated for use with water only.
WARNING
IMPORTANT! For your own safety –before starting to run the pump,
please have the following items checked by an expert:
- Risk of electric shock – This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
- Risk of electric shock – This pump has not been investigated for use in swimming pool areas.
- The electrical connections must be protected from moisture.
- If there is a danger of flooding, the electrical connections must be taken to higher ground.
- Circulation of caustic fluids, as well as the circulation of abrasive materials, must be avoided at all costs.
- The pump must be protected from frost.
- The pump must be protected from running dry.
- Access by children should also be prevented with appropriate measures.
- To prevent death from electric shock, the pump must be connected only to a GFCI protected outlet.
- Do not use an extension cord with this item.
- People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to the heart pacemakers could cause pacemaker interference or pacemaker failure.
- The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur.
It must be understood by the operator that common sense and caution are factors that cannot be built into this product but must be supplied by the operator.
Fluid Type
The Pump is designed for use with water with a maximum temperature of 77° F (25°C). Do not use the pump for other fluids, especially not fuels, cleaning fluids, or other chemical products.
Specifications
| 63318| 63319
---|---|---
Horse Power| 1/3 HP| 1/6 HP
Electrical Rating| 120VAC / 60Hz / 3.5A| 120VAC / 60Hz / 3A
Power Cord Length| 25’| 10’
Maximum Flow @ 0’| 2000 GPH| 1600 GPH
Maximum Head lift @ 0’ Flow| 31′| 25′
Discharge Port| 1″ NPT| 1″ NPT
Installation
The submersible motor pump must be installed in a stationary position with
either:
a. A fixed pipeline or
b. A flexible hose pipe.
Please note!
-
Do not install the pump by suspending it unsupported from its delivery pipe or power cord.
The pump must be suspended from the handle or be placed on the bottom of the basin.
To ensure that the pump works properly, keep the bottom free from sludge and dirt of all kinds. -
If the water level sinks too low, any sludge in the basin will dry out and stop the pump from starting.
To help ensure the pump will start as required, check the pump regularly with start-up tests.
Power Supply
- The pump is equipped with a shock-proof plug according to regulations. The pump is designed to be connected to a 120 VAC, 60 Hz GFCI protected socket.
- Make sure that the socket is sufficiently secured and is in excellent condition.
- When the plug is inserted into the socket, the pump will be on standby.
- WARNING: To prevent death from electric shock, the pump must be connected only to a GFCI protected outlet.
CAUTION! If the power cord or plug is damaged, do not use the pump. The
power cord or plug may only be repaired by a certified electrician.
Areas of use
-
This pump is designed to pump water only.
-
This pump is designed to be used for: Removing water from flooded basements, window wells, garages, flat roofs.
Pumping drinking water from shallow wells and cisterns. Irrigation systems. -
This pump should NOT be used for:
Continuous run, fountain/pond water features. Septic or sewage systems. Water with dirt and debris. -
This pump can also be used to transfer water (e.g. household, farming, plumbing).
Installation Instructions
-
Place pump in water.
WARNING! TO PREVENT SERIOUS INJURY: Do not use an extension cord with this pump.
Keep plug dry and secured away from water. -
Attach one end of a discharge hose to the discharge port. Place the other end as needed to direct the water discharge at least 3 feet away from the source. Slope the discharge hose downward, away from the source.
Pump Position -
Plug Power Cord into GFCI protected outlet.
Operation
After reading these instructions, consider the following points before starting the pump:
- Verify that the pump rests on the floor of the basin if it is not suspended by the handle.
- Verify that the discharge pipe is properly connected.
- Verify that the electrical connection is 120 VAC, 60 Hz.
- Verify that the electrical socket is GFCI protected and in good condition. Test GFCI protected outlet before use.
- Verify that water and moisture cannot get near the power supply socket.
- Verify that the pump is installed so as to prevent running dry.
NOTE: The Pump will not start without 1″ of water.
NOTE: The Pump will remove water down to 1/4″.
Unplug the Pump once the 1/4″ water level is reached.
Maintenance
WARNING
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Unplug the Pump from its electrical outlet before performing any inspection,
maintenance, or cleaning procedures.
If the pump is moved during operation, flush it out with clean water after
every use.
Quarterly Maintenance
The below maintenance must be performed at least once every 3 months under
optimal conditions.
For frequent use, or dirty areas, more frequent maintenance is required.
-
Clean sludge and debris from the bottom of the basin.
-
Clean sludge/debris from the inlet screen.
-
If the pump housing cannot be cleaned from the outside, it must be thoroughly cleaned.
Unplug the power cord before maintenance.
Dismantle the bottom part of the pump as follows:
a. Remove Screws (9) and Volute (8).
b. Clean the impeller with clean water.
c. To prevent damage, do not rest the pump on the impeller or pry against the impeller.
d. Reassemble in reverse order. -
Make sure the discharge pipe is free from leaks.
-
Make sure the check valve is functioning properly.
-
Manually operate flow switch to determine that pump turns on/off as intended.
Parts List and Diagram
PLEASE READ THE FOLLOWING CAREFULLY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY
DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER NOR
DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT
HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE
IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER
AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS
SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE
BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER
REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF
HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
Parts List
Part | Description | Qty |
---|---|---|
1 | Pump Cord | 1 |
2 | Adaptor | 1 |
3 | Handle | 1 |
4 | Motor | 1 |
5 | Shaft | 1 |
6 | Impeller | 1 |
7 | Gasket | 1 |
8 | Volute | 1 |
9 | Screw | 8 |
10 | Base | 1 |
11 | Screw | 4 |
Record Product’s Serial Number Here:
Note: If the product has no serial number, record the month and year of
purchase instead.
Note: Some parts are listed and shown for illustration purposes only, and
are not available individually as replacement parts. Parts may not be
interchangeable.
Note: When ordering parts, specify which model the parts are being
ordered for. Specify UPC number when ordering:
1/6 HP: 193175312747
1/3 HP: 193175312754
Assembly Diagram
Limited 90 Day Warranty
Harbor Freight Tools Co. makes every effort to assure that its products meet
high quality and durability standards, and warrants to the original purchaser
that this product is free from defects in materials and workmanship for the
period of 90 days from the date of purchase. This warranty does not apply to
damage due directly or indirectly, to misuse, abuse, negligence or accidents,
repairs or alterations outside our facilities, criminal activity, improper
installation, normal wear, and tear, or to lack of maintenance. We shall in no
event be liable for death, injuries to persons or property, or for incidental,
contingent, special or consequential damages arising from the use of our
product. Some states do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to
you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.
To take advantage of this warranty, the product or part must be returned to us
with transportation charges prepaid. Proof of purchase date and an explanation
of the complaint must accompany the merchandise.
If our inspection verifies the defect, we will either repair or replace the
product at our election or we may elect to refund the purchase price if we
cannot readily and quickly provide you with a replacement. We will return
repaired products at our expense, but if we determine there is no defect, or
that the defect resulted from causes not within the scope of our warranty,
then you must bear the cost of returning the product.
This warranty gives you specific legal rights and you may also have other
rights which vary from state to state.
26541 Agoura Road
Calabasas, CA 91302
1-888-866-5797