DRUMMOND 63316 Non-Submersible Transfer Pump Owner’s Manual
- June 4, 2024
- DRUMMOND
Table of Contents
63316, 1/2
Non-Submersible Transfer Pump
**Owner’s Manual
**
Safety Instructions
Save This Manual Keep this manual for safety warnings and precautions,
assembly, operating, inspection, maintenance, and cleaning procedures. Write
the product’s serial number on the back of the manual (or month and year of
purchase if a product has no number). Keep this manual and the receipt in a
safe and dry place for future reference.
Do not return the pump to the store.
Call 1-844-416-9141
Visit our website at: http://www.harborfreight.com
Email our technical support at:
productsupport@harborfreight.com
When unpacking, make sure that the product is intact and undamaged. If any
parts are missing or broken, please call
1-888-866-5797 as soon as possible.
Copyright© 2022 by Harbor Freight Tools® All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, the actual product may differ slightly from the product
described herein. Tools required for assembly and service may not be included.
WARNING
Read this material before using this product. Failure to do so can result in
serious injury. SAVE THIS MANUAL.
Before start-up, note the following:
The pump must be connected to a GFCI-protected plug that has been installed
according to regulations. The plug must have a supply voltage of 120 VAC at 60
Hz.
CAUTION
This pump has been evaluated for use with water only.
WARNING
IMPORTANT! For your own safety –before starting to run the pump, please
have the following items checked by an expert:
- Risk of electric shock – This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.
- Risk of electric shock – This pump has not been investigated for use in swimming pool areas.
- The electrical connections must be protected from moisture.
- If there is a danger of flooding, the electrical connections must be taken to higher ground.
- Circulation of caustic fluids, as well as the circulation of abrasive materials, must be avoided at all costs.
- The pump must be protected from frost.
- The pump must be protected from running dry.
- Access by children should also be prevented with appropriate measures.
- To prevent death from electric shock, the pump must be connected only to a GFCI-protected outlet.
- Do not pump flammable materials. Motor brushes may spark and cause explosions.
- Do not use an extension cord with this item.
- People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to the heart pacemaker could cause pacemaker interference or pacemaker failure.
- The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors that cannot be built into this product but must be supplied by the operator.
Fluid Type
The Pump is designed for use with water with a maximum temperature of 95° F
(35°C). Do not use the pump for other fluids, especially not fuels, cleaning
fluids, or other chemical products.
Specifications
Horsepower | 1/2 HP |
---|---|
Electrical Rating | 120VAC / 60Hz / 9A |
Power Cord Length | 8’ |
Maximum Flow @ 0’ | 1525 GPH |
Maximum Head lift @ 0’ Flow | 56 PSIG |
Discharge Port | 3/4″ Garden Hose Thread |
Installation
The pump must be installed in a stationary position with either:
a. A fixed pipeline or
b. A flexible hose.
Please note!
- Do not allow the pump to hang suspended by the power cord, inlet pipe, or hose. The pump must be set on a stable surface or suspended from the handle. To ensure that the pump works properly, keep the bottom free from sludge and dirt of all kinds.
- If the water level sinks too low, any sludge in the basin will dry out and stop the pump from starting. To help ensure the pump will start as required, check the pump regularly with start-up tests.
Power Supply
- The pump is equipped with a shock-proof plug according to regulations. The pump is designed to be connected to a 120 VAC, 60 Hz GFCI-protected socket.
- Make sure that the socket is sufficiently secured and in excellent condition.
- Depending on the application, a separate flow switch (not included) may be needed between the plug and the outlet.
- When the plug is inserted directly into the socket, the pump will turn on.
- WARNING: To prevent death from electric shock, the pump must be connected only to a GFCI-protected outlet.
WARNING! TO PREVENT SERIOUS INJURY:
If the power cord or plug is damaged, do not use the pump. The power cord or
plug may only be repaired by a certified electrician.
Areas of use
-
This pump is designed to pump water only.
-
This pump is designed to be used for:
General purpose removal or transfer of clear water. -
This pump should NOT be used for:
Continuous run, fountain/pond water features.
Removing water from swimming pools or spas. Septic or sewage systems. -
This pump can also be used to transfer water (e.g. household, farming, plumbing).
Installation Instructions
-
Attach the hose to the Pump intake port. A tach second hose to the Pump discharge port.
-
Position the Pump on a solid surface so that both hoses are free from kinks. Plug the Power Cord into GFCI protected outlet.
-
Place the unused end of the intake hose in water to be transferred. Place the unused end of the discharge hose as needed to direct the water discharge at least 3 feet away from the source.
Operation
After reading these instructions, consider the following points before starting the pump:
- Verify that the discharge pipe is properly connected.
- Verify that the electrical connection is 120 VAC, 60 Hz.
- Verify that the electrical socket is GFCI protected and in good condition. Test GFCI-protected outlet before use.
- Verify that water and moisture cannot get near the power supply socket.
- Verify that the pump is installed so as to prevent running dry.
Maintenance
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Unplug the Pump from its electrical outlet before performing any inspection,
maintenance, or cleaning procedures.
If the pump is moved during operation, flush it out with clean water after
every use.
Quarterly Maintenance
The below maintenance must be performed at least once every 3 months under
optimal conditions.
For frequent use, or dirty areas, more frequent maintenance is required.
- Clean sludge and debris from the bottom of the basin.
- Clean sludge/debris from the inlet screen.
- Make sure the discharge pipe is free from leaks.
- Make sure the check valve is functioning properly.
- Manually operate any separate flow switch (not included) to determine that the pump turns on/off as intended.
Carbon Brush Maintenance
The carbon brushes may require maintenance when the motor performance of
the pump decreases or stops working completely. To maintain the brushes:
- Remove the carbon brushes from the housing. Keep track of which orientation the old carbon brushes were in to prevent needless wear if they will be reinstalled.
- If either carbon brush is worn down by more than 1/2, replace both carbon brushes.
- To clean old carbon brushes before reusing them, rub the contact areas with a pencil eraser.
- Reinsert the old carbon brushes in the same orientation to reduce wear.
- When installing the carbon brushes, make sure the carbon portions of the carbon brushes contact the motor armature, and that the springs face away from the motor. Also, make sure the springs operate freely.
Note: New carbon brushes tend to spark when first used until they wear and conform to the motor’s armature.
Troubleshooting
Problem
| Possible Causes|
Possible Solutions
---|---|---
The pump runs, but will not deliver any water.| 1. Inlet Screen and/or
impeller clogged.
2. Low line voltage.
3. Check valve (sold separately) is stuck or installed backward.| 1. Remove
Inlet Screen. Clean out dirt and debris from Inlet Screen and impeller. Then
replace Inlet Screen.
2. Consult an electrician.
3. Remove and examine the check valve.
The pump won’t start or run.| 1. Check power connections and circuits/fuses.
2. Inlet Screen and/or impeller clogged.
3. Defective motor.| 1. Consult an electrician.
2. Remove the Inlet Screen. Clean out Inlet Screen and impeller. Reinstall
Inlet Screen.
3. Have a qualified service technician repair or replace.
Excessive noise or
vibration.| 1. Debris in the impeller.
2. Discharge hose restricted.| 1. Remove Inlet Screen. Clean impeller.
Reinstall Inlet Screen.
2. Clean the Pump and discharge hose.
The pump starts and stops too frequently.| 1. Water temperature too high.
2. Check valve (sold separately) is stuck or installed backward.
3. Backflow of water from the discharge hose.| 1. Do not exceed 95° F (35°C)
water temperature.
2. Remove and examine the check valve.
3. Install or inspect the check valve (sold separately).
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect the power supply before service.
Parts List and Diagram
PLEASE READ THE FOLLOWING CAREFULLY
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY
DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER NOR
DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT
HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE
IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER
AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS
SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE
BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER
REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF
HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.
Parts List
Part
| Description|
Qty.
---|---|---
1| Priming Plug| 1
2| O-ring| 1
3| Hose Fitting| 2
4| Pump Gasket| 1
5| Motor| 1
6| Spring Washer| 4
7| Screw| 4
8| Pump Facing| 1
9| Impeller| 1
10| Mechanical Seal| 1
11| Water Retaining Washer| 1
12| Rubber Foot| 3
13| Carbon Brush Combination| 2
Record the Product’s Serial Number Here:
Note: If the product has no serial number, record the month and year of
purchase instead.
Note: Some parts are listed and shown for illustration purposes only, and
are not available individually as replacement parts. Specify UPC 193175314857
when ordering parts.
Assembly Diagram
Limited 90-Day Warranty
Harbor Freight Tools Co. makes every effort to assure that its products
meet high quality and durability standards, and warrants to the original
purchaser that this product is free from defects in materials and workmanship
for the period of 90 days from the date of purchase. This warranty does not
apply to damage due directly or indirectly, to misuse, abuse, negligence or
accidents, repairs or alterations outside our facilities, criminal activity,
improper installation, normal wear, and tear, or to lack of maintenance. We
shall in no event be liable for death, injuries to persons or property, or for
incidental, contingent, special or consequential damages arising from the use
of our product. Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation or exclusion may
not apply to you. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.
To take advantage of this warranty, the product or part must be returned to us
with transportation charges prepaid. Proof of purchase date and an explanation
of the complaint must accompany the merchandise. If our inspection verifies
the defect, we will either repair or replace the product at our election or we
may elect to refund the purchase price if we cannot readily and quickly
provide you with a replacement. We will return repaired products at our
expense, but if we determine there is no defect, or that the defect resulted
from causes not within the scope of our warranty, then you must bear the cost
of returning the product. This warranty gives you specific legal rights and
you may also have other rights which vary from state to state.
For technical questions, please
26677 Agoura Road
• Calabasas, CA 91302
• 1-888-866-5797
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>