LEDLENSER P6R CORE Rechargeable LED Flashlight User Manual

June 6, 2024
LEDLenser

P6R CORE Rechargeable LED Flashlight

USER MANUAL P6R CORE P7R CORE

Many Thanks
We are pleased that you have chosen a product from our company. To familiarize yourself with your new product, you will find information for safety and operation in these operating instructions.
These instructions for use must be read carefully before using the product. It must be kept and handed over to third parties when the product is passed on.
This also serves to ensure that you get the maximum benefit from your product, get answers to your questions and avoid operating errors. Therefore, pay particular attention to the warning and safety instructions and properly dispose of the lamp, batteries and packaging material.

P6R Core

P7R Core

User Manual P6R Core | P7R Core V.01 06.2021

2

Table of contents
1. Scope of delivery 2. Warning 3. Magnetic Charging System 4. Battery Replacement 5. Default Operation 6. Boost Function 7. Advanced Focus System 8. Backup Mode 9. Customizing Light Modes 10. Additional Functions 11. Reset to Factory Settings 12. Further Information

General product information
The Ledlenser P6R Core and P7R Core are flashlights and may only be used as such for lighting purposes. Use the products only at ambient temperatures of -20°C to + 40°C. The flashlights do not be used in areas with a potentially explosive atmosphere. The flashlights are no toys and are not suitable for small children.
Please register your product with the enclosed registration card to obtain an extended warranty, check the authenticity of the product and receive updates about products or product improvements.

User Manual P6R Core | P7R Core V.01 06.2021

3

1 Scope of delivery

P7R Core

21700

P6R Core

18650

1. The flashlight is delivered with the scope of delivery shown. The product may only be used with the following rechargeable batteries:
P6R Core: 18650 Li-ion, 3.7V (Item No. 501001) P7R Core: 21700 Li-ion, 3.7V (Item No. 502262)
Rechargeable batteries may only be charged at temperatures from 10°C to 40°C.

Lanyard 1. 2.

User Manual P6R Core | P7R Core V.01 06.2021

4

2 WARNING

2. CAUTION: The lamp generates heat when in use. Do not cover the lamp during operation, this can lead to heat build-up. Maintain a distance of at least 10 cm between the lamp and illuminated surfaces.

Transportation Lock
4x blink

hold =5s

Make sure that the lamp is locked during transport and cannot be switched on accidentally.

3 Magnetic Charging System

?

5V

red green red + green blink

3. The included USB magnetic charging cable is used for charging. If the contacts on the lamp or cable are dirty or dusty, first clean them with a dry cloth. Then connect the cable to the lamp, paying attention to the correct orientation of the contacts. Finally, connect the charging cable to a standard USB power supply or computer.
While the lamp is charging, the charge level indicator lights up red. When the charging process is complete, the display changes to green. If an error occurs, the charge indicator flashes (e.g. defective or incorrectly inserted battery).
Rechargeable batteries may only be charged at temperatures of 10°C to 40°C. Optionally, the batteries can be removed from the lamp and charged externally with a suitable charger.

User Manual P6R Core | P7R Core V.01 06.2021

5

4 Battery Replacement

4. To remove the rechargeable battery, the end cap of the lamp is screwed off. The battery can then be removed. When inserting a new battery, pay attention to the correct polarity (+/-). This is marked on the battery and inside the lamp shaft. Only approved batteries may be used. Then close the lamp again by screwing the end cap on. To ensure watertightness, make sure that the seals are undamaged.

5 Default Operation

Off Power Mid Power Low Power
Off

1x

+1x

<3s

+1x

<3s

+1x

5. This lamp has several light functions or brightness levels.
The desired function can be selected within the first three seconds after switching the lamp on. To do this, first switch the lamp on and then tap the switch once within three seconds to switch to the next function.
If the switch has not been pressed for more than three seconds or if the last available light function has been selected, the lamp switches off the next time the switch is pressed.
When the lamp is switched on, the remaining battery capacity is displayed (GREEN fully charged; ORANGE half full; RED almost empty)
If the ,,Memory Mode” is active, the lamp always turns on with the previously selected light function. If the ,,Memory Mode” is deactivated, the lamp always starts with the same light function. The ,,Memory Mode” can be activated and deactivated in the advanced settings (10).

User Manual P6R Core | P7R Core V.01 06.2021

6

6 Boost Function

2x

Boost =10s

6. In boost mode, the lamp lights up with the maximum available brightness for a period of ten seconds. The boost mode can be activated at any time by double tapping the switch, except when the transportation lock is activated. After ten seconds the lamp switches back to the previously selected light function.

7 Advanced Focus System
defocused focused

7. Different activities require different light. By turning the lamp head whilst moving it forwards or backwards, the light can be focused for maximum beam distance or defocused for even illumination of the close-up area.

8 Backup Mode
<25%

<25% Backup

8. If the remaining battery capacity is low – after the regular runtime has expired – the lamp switches to ,,Backup Mode”. In this mode the lamp can only be used in the lowest brightness level. It prevents the lamp from suddenly switching off and ensures that the user still has light available when the battery is weak.
The ,,Backup Mode” can be activated or deactivated in the advanced settings. If the backup mode is deactivated, the lamp is operated at full brightness until the end of the battery capacity and then switches off immediately.
When the ,,Low Battery Warning” is active, which can be activated or deactivated in the advanced settings, the lamp gives a flashing signal every 15 minutes when the battery capacity is low.

User Manual P6R Core | P7R Core V.01 06.2021

7

9 Customizing Light Modes
hold =8s
On
1x blink

9. The flashlight is preset with selected light functions and brightness levels. If desired, the default settings can be changed via the switch on the lamp. Proceed as follows:
– Hold down the switch for five seconds while the light is on. Do not cover the switch completely, in order to still be able to see the indicator light inside the switch.
– After five seconds the switch will flash briefly. Release the switch immediately.
– By briefly pressing the switch, you can switch through all available light functions and brightness levelsn.

Low Power Mid Power Power Dim

NEXT
2x blink hold =2s

– If you want to save the selected light function, hold the switch down for two seconds. The switch will flash twice to confirm. You can repeat this process up to a total of ten times in order to save further light functions.

Blink Flashing Position SOS Strobe

hold =4s
2x blink
3x blink

– Alternatively, press and hold the switch for four seconds to save the selected light function(s) and to end the process (after the switch has flashed three times).
– The lamp has now been programmed with the selected light functions. These can now be activated in the selected order by tapping the switch several times within three seconds after switching the lamp on.

SAVE & EXIT

User Manual P6R Core | P7R Core V.01 06.2021

8

10 Additional Functions
hold =8s
On
1x blink
2x blink

10. You can use the advanced settings to switch additional functions on or off. To do this, switch on the lamp. Hold down the switch for about eight seconds. The switch flashes once, then twice. Release the switch when it has blinked twice.

1x
2x green blink: Memory Mode ON 2x red blink: Memory Mode OFF 2x
2x green blink: Low Battery Warning ON 2x red blink: Low Battery Warning OFF 3x
2x green blink: Emergency Mode ON 2x red blink: Emergency Mode OFF
User Manual P6R Core | P7R Core V.01 06.2021

Now tap the switch briefly several times to activate or deactivate functions. If you want to activate or deactivate another function, start the process again from the beginning (10.).
With a single tap, the Memory Mode is switched on or off (see also No. 5).
If you tap it twice, the Low Battery Warning is switched on or off (see also No. 8).
If you tap it three times, the Emergency Mode is switched on or off. When the emergency mode is active, the lamp is switched on automatically if it is disconnected from the power supply while charging. This means that the lamp comes on automatically in the event of a power failure or is immediately active when it is removed from the holder.
9

4x
2x green blink: Backup Mode ON 2x red blink: Backup Mode OFF
11 Reset to factory settings
hold =8s
ON
1x blink

If you tap the switch four times, the Backup Mode is switched on or off (see also No. 8).
11. The lamp can be reset to factory settings. To do this, switch on the lamp. Hold down the switch for about eight seconds. The switch flashes once, then twice. Release the switch when it has blinked twice.

2x blink

hold =5s
4x green blink: Reset

Then press the switch again for five seconds until it flashes four times. Now release the switch. The lamp has been reset to the factory settings and can be used again as usual.

User Manual P6R Core | P7R Core V.01 06.2021

10

12 Further Information

?

12. Further information, tutorials and accessories can be found on our website. Simply scan the QR code or visit

www.ledlenser.com.

i

P6R Core

P7R Core

ledlenser.com

Ledlenser GmbH & Co. KG Kronenstr. 5-7, 42699 Solingen Phone +49 212/5948-0 Fax +49 212/5948-200 [email protected]

User Manual P6R Core | P7R Core V.01 06.2021

11

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LEDLenser User Manuals

Related Manuals