P6R CORE Rechargeable LED Flashlight
USER MANUAL P6R CORE P7R CORE
Many Thanks
We are pleased that you have chosen a product from our company. To familiarize
yourself with your new product, you will find information for safety and
operation in these operating instructions.
These instructions for use must be read carefully before using the product. It
must be kept and handed over to third parties when the product is passed on.
This also serves to ensure that you get the maximum benefit from your product,
get answers to your questions and avoid operating errors. Therefore, pay
particular attention to the warning and safety instructions and properly
dispose of the lamp, batteries and packaging material.
P6R Core
P7R Core
User Manual P6R Core | P7R Core V.01 06.2021
2
Table of contents
1. Scope of delivery 2. Warning 3. Magnetic Charging System 4. Battery
Replacement 5. Default Operation 6. Boost Function 7. Advanced Focus System 8.
Backup Mode 9. Customizing Light Modes 10. Additional Functions 11. Reset to
Factory Settings 12. Further Information
General product information
The Ledlenser P6R Core and P7R Core are flashlights and may only be used as
such for lighting purposes. Use the products only at ambient temperatures of
-20°C to + 40°C. The flashlights do not be used in areas with a potentially
explosive atmosphere. The flashlights are no toys and are not suitable for
small children.
Please register your product with the enclosed registration card to obtain an
extended warranty, check the authenticity of the product and receive updates
about products or product improvements.
User Manual P6R Core | P7R Core V.01 06.2021
3
1 Scope of delivery
P7R Core
21700
P6R Core
18650
1. The flashlight is delivered with the scope of delivery shown. The product
may only be used with the following rechargeable batteries:
P6R Core: 18650 Li-ion, 3.7V (Item No. 501001) P7R Core: 21700 Li-ion, 3.7V
(Item No. 502262)
Rechargeable batteries may only be charged at temperatures from 10°C to 40°C.
Lanyard 1. 2.
User Manual P6R Core | P7R Core V.01 06.2021
4
2 WARNING
2. CAUTION: The lamp generates heat when in use. Do not cover the lamp during operation, this can lead to heat build-up. Maintain a distance of at least 10 cm between the lamp and illuminated surfaces.
Transportation Lock
4x blink
hold =5s
Make sure that the lamp is locked during transport and cannot be switched on accidentally.
3 Magnetic Charging System
?
–
5V
red green red + green blink
3. The included USB magnetic charging cable is used for charging. If the
contacts on the lamp or cable are dirty or dusty, first clean them with a dry
cloth. Then connect the cable to the lamp, paying attention to the correct
orientation of the contacts. Finally, connect the charging cable to a standard
USB power supply or computer.
While the lamp is charging, the charge level indicator lights up red. When the
charging process is complete, the display changes to green. If an error
occurs, the charge indicator flashes (e.g. defective or incorrectly inserted
battery).
Rechargeable batteries may only be charged at temperatures of 10°C to 40°C.
Optionally, the batteries can be removed from the lamp and charged externally
with a suitable charger.
User Manual P6R Core | P7R Core V.01 06.2021
5
4 Battery Replacement
4. To remove the rechargeable battery, the end cap of the lamp is screwed off. The battery can then be removed. When inserting a new battery, pay attention to the correct polarity (+/-). This is marked on the battery and inside the lamp shaft. Only approved batteries may be used. Then close the lamp again by screwing the end cap on. To ensure watertightness, make sure that the seals are undamaged.
5 Default Operation
Off Power Mid Power Low Power
Off
1x
+1x
<3s
+1x
<3s
+1x
5. This lamp has several light functions or brightness levels.
The desired function can be selected within the first three seconds after
switching the lamp on. To do this, first switch the lamp on and then tap the
switch once within three seconds to switch to the next function.
If the switch has not been pressed for more than three seconds or if the last
available light function has been selected, the lamp switches off the next
time the switch is pressed.
When the lamp is switched on, the remaining battery capacity is displayed
(GREEN fully charged; ORANGE half full; RED almost empty)
If the ,,Memory Mode” is active, the lamp always turns on with the previously
selected light function. If the ,,Memory Mode” is deactivated, the lamp always
starts with the same light function. The ,,Memory Mode” can be activated and
deactivated in the advanced settings (10).
User Manual P6R Core | P7R Core V.01 06.2021
6
6 Boost Function
2x
Boost =10s
6. In boost mode, the lamp lights up with the maximum available brightness for a period of ten seconds. The boost mode can be activated at any time by double tapping the switch, except when the transportation lock is activated. After ten seconds the lamp switches back to the previously selected light function.
7 Advanced Focus System
defocused focused
7. Different activities require different light. By turning the lamp head whilst moving it forwards or backwards, the light can be focused for maximum beam distance or defocused for even illumination of the close-up area.
8 Backup Mode
<25%
<25% Backup
8. If the remaining battery capacity is low – after the regular runtime has
expired – the lamp switches to ,,Backup Mode”. In this mode the lamp can only
be used in the lowest brightness level. It prevents the lamp from suddenly
switching off and ensures that the user still has light available when the
battery is weak.
The ,,Backup Mode” can be activated or deactivated in the advanced settings.
If the backup mode is deactivated, the lamp is operated at full brightness
until the end of the battery capacity and then switches off immediately.
When the ,,Low Battery Warning” is active, which can be activated or
deactivated in the advanced settings, the lamp gives a flashing signal every
15 minutes when the battery capacity is low.
User Manual P6R Core | P7R Core V.01 06.2021
7
9 Customizing Light Modes
hold =8s
On
1x blink
9. The flashlight is preset with selected light functions and brightness
levels. If desired, the default settings can be changed via the switch on the
lamp. Proceed as follows:
– Hold down the switch for five seconds while the light is on. Do not cover
the switch completely, in order to still be able to see the indicator light
inside the switch.
– After five seconds the switch will flash briefly. Release the switch
immediately.
– By briefly pressing the switch, you can switch through all available light
functions and brightness levelsn.
Low Power Mid Power Power Dim
NEXT
2x blink hold =2s
– If you want to save the selected light function, hold the switch down for two seconds. The switch will flash twice to confirm. You can repeat this process up to a total of ten times in order to save further light functions.
Blink Flashing Position SOS Strobe
hold =4s
2x blink
3x blink
– Alternatively, press and hold the switch for four seconds to save the
selected light function(s) and to end the process (after the switch has
flashed three times).
– The lamp has now been programmed with the selected light functions. These
can now be activated in the selected order by tapping the switch several times
within three seconds after switching the lamp on.
SAVE & EXIT
User Manual P6R Core | P7R Core V.01 06.2021
8
10 Additional Functions
hold =8s
On
1x blink
2x blink
10. You can use the advanced settings to switch additional functions on or off. To do this, switch on the lamp. Hold down the switch for about eight seconds. The switch flashes once, then twice. Release the switch when it has blinked twice.
1x
2x green blink: Memory Mode ON 2x red blink: Memory Mode OFF 2x
2x green blink: Low Battery Warning ON 2x red blink: Low Battery Warning OFF
3x
2x green blink: Emergency Mode ON 2x red blink: Emergency Mode OFF
User Manual P6R Core | P7R Core V.01 06.2021
Now tap the switch briefly several times to activate or deactivate functions.
If you want to activate or deactivate another function, start the process
again from the beginning (10.).
With a single tap, the Memory Mode is switched on or off (see also No. 5).
If you tap it twice, the Low Battery Warning is switched on or off (see also
No. 8).
If you tap it three times, the Emergency Mode is switched on or off. When the
emergency mode is active, the lamp is switched on automatically if it is
disconnected from the power supply while charging. This means that the lamp
comes on automatically in the event of a power failure or is immediately
active when it is removed from the holder.
9
4x
2x green blink: Backup Mode ON 2x red blink: Backup Mode OFF
11 Reset to factory settings
hold =8s
ON
1x blink
If you tap the switch four times, the Backup Mode is switched on or off (see
also No. 8).
11. The lamp can be reset to factory settings. To do this, switch on the
lamp. Hold down the switch for about eight seconds. The switch flashes once,
then twice. Release the switch when it has blinked twice.
2x blink
hold =5s
4x green blink: Reset
Then press the switch again for five seconds until it flashes four times. Now release the switch. The lamp has been reset to the factory settings and can be used again as usual.
User Manual P6R Core | P7R Core V.01 06.2021
10
12 Further Information
?
12. Further information, tutorials and accessories can be found on our website. Simply scan the QR code or visit
www.ledlenser.com.
i
P6R Core
P7R Core
ledlenser.com
Ledlenser GmbH & Co. KG Kronenstr. 5-7, 42699 Solingen Phone +49 212/5948-0 Fax +49 212/5948-200 info@ledlenser.com
User Manual P6R Core | P7R Core V.01 06.2021
11
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>