LEDLENSER 502189 P6R Signature LED Torch Rechargeable User Manual
- June 6, 2024
- LEDLenser
Table of Contents
- General product information
- Scope of delivery
- WARNING
- Magnetic Charging System
- Battery Replacement
- Default Operation
- Boost Function
- Advanced Focus System
- Backup Mode
- Customizing Light Modes
- Additional Functions
- Reset to factory settings
- Further Information
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
USER MANUAL
P6R SIGNATURE
P7R SIGNATURE
Many Thanks
We are pleased that you have chosen a product from our company. To familiarize
yourself with your new product, you will find information for safety and
operation in these operating instructions. These instructions for use must be
read carefully before using the product. It must be kept and handed over to
third parties when the product is passed on. This also serves to ensure that
you get the maximum benefit from your product, get answers to your questions
and avoid operating errors. Therefore, pay particular attention to the warning
and safety instructions and properly dispose of the lamp, batteries, and
packaging material.
P7R Signature | P6R Signature |
---|
General product information
The Ledlenser P7R Signature and P6R Signature are flashlights and may only be
used as such for lighting purposes. Use the products only at ambient
temperatures of -20°C to + 40°C. The flashlights do not be used in areas with
a potentially explosive atmosphere. The flashlights are no toys and are not
suitable for small children.
Please register your product with the enclosed registration card to obtain an
extended warranty, check the authenticity of the product and receive updates
about products or product improvements.
Scope of delivery
1. The flashlight is delivered with the scope of delivery shown. The product
may only be used with the following rechargeable batteries:
P6R Signature: 18650 Li-ion, 3.7V (Item No. 501001)
P7R Signature: 21700 Li-ion, 3.7V (Item No. 502262)
Rechargeable batteries may only be charged at temperatures from 10°C to 40°C.
WARNING
2. CAUTION: The lamp generates heat when in use. Do not cover the lamp
during operation, this can lead to heat build-up. Maintain a distance of at
least 10 cm between the lamp and illuminated surfaces.
Make sure that the lamp is locked during transport and cannot be switched on
accidentally.
Magnetic Charging System
3. The included USB magnetic charging cable is used for charging. If the contacts on the lamp or cable are dirty or dusty, first clean them with a dry cloth. Then connect the cable to the lamp, paying attention to the correct orientation of the contacts. Finally, connect the charging cable to a standard USB power supply or computer. While the lamp is charging, the charge level indicator lights up red. When the charging process is complete, the display changes to green. If an error occurs, the charge indicator flashes (e.g. defective or incorrectly inserted battery). A wall bracket is included with the lamp, in which the USB magnetic charging cable can also be inserted. The lamp is placed in the charging station/wall bracket for charging. When the lamp is inserted correctly, the charging indicator lights up during the charging process as described above. Rechargeable batteries may only be charged at temperatures of 10°C to 40°C. Optionally, the batteries can be removed from the lamp and charged externally with a suitable charger.
Battery Replacement
4. To remove the rechargeable battery, the end cap of the lamp is screwed off. The battery can then be removed. When inserting a new battery, pay attention to the correct polarity (+/-). This is marked on the battery and inside the lamp shaft. Only approved batteries may be used. Then close the lamp again by screwing the end cap on. To ensure ”
water tightness, make sure that the seals are undamaged.
Default Operation
5. This lamp has several light functions or brightness levels. This lamp also
offers a MODE SWITCH with four positions. Depending on the position of the
mode switch, various light functions can be reached quickly.
The desired function can be selected within the first three seconds after
switching the lamp on. To do this, first switch the lamp on and then tap the
switch once within three seconds to switch to the next function. If the switch
has not been pressed for more than three seconds or if the last available
light function has been selected, the lamp switches off the next time the
switch is pressed. When the lamp is switched on, the remaining battery
capacity is displayed (GREEN fully charged; ORANGE half full; RED almost
empty) If the „Memory Mode“ is active, the lamp always turns on with the
previously selected light function.
If the „Memory Mode“ is deactivated, the lamp always starts with the same
light function. The „Memory Mode“ can be activated and deactivated in the
advanced settings (10).
MODE SWITCH | Position 1
Light modes: Power, Mid Power, Low Power
MODE SWITCH | Position 2
Red Light
MODE SWITCH | Position 3
Light modes: Strobe and Power
MODE SWITCH | Position 4
Light modes: SOS and Blink
Boost Function
6. In boost mode, the lamp lights up with the maximum available brightness for a period of ten seconds. The boost mode can be activated at any time by double-tapping the switch, except when the transportation lock is activated. After ten seconds the lamp switches back to the previously selected light function.
Advanced Focus System
7. Different activities require different light. By turning the lamp head whilst moving it forwards or backward, the light can be focused for maximum beam distance or defocused for even illumination of the close-up area.
Backup Mode
8. If the remaining battery capacity is low – after the regular runtime has
expired – the lamp switches to „Backup Mode“. In this mode, the lamp can only
be used at the lowest brightness level. It prevents the lamp from suddenly
switching off and ensures that `the user still has light available when the
battery is weak.
The „Backup Mode“ can be activated or deactivated in the advanced settings. If
the backup mode is deactivated, the lamp is operated at full brightness until
the end of the battery capacity and then switches off immediately.
When the „Low Battery Warning“ is active, which can be activated or
deactivated in the advanced settings, the lamp gives a flashing signal every
15 minutes when the battery capacity is low.
Customizing Light Modes
9. The flashlight is preset with selected light functions and brightness
levels. If desired, the default settings can be changed via the switch on the
lamp. Proceed as follows:
– Hold down the switch for five seconds while the light is on. Do not cover the
switch completely, in order to still be able to see the indicator light inside
the switch.
– After five seconds the switch will flash briefly. Release the switch
immediately.
– By briefly pressing the switch, you can switch through all available light
functions and brightness levels.
– If you want to save the selected light function, hold the switch down for
two seconds. The switch will flash twice to confirm. You can repeat this
process up to a total of ten times in order to save further light functions.
Alternatively, press and hold the switch for four seconds to save the selected
light function(s) and to end the process (after the switch has flashed three
times).
The lamp was now been programmed with the selected light functions. These can
now be activated in the selected order by tapping the switch several times
within three seconds after switching the lamp on.
Additional Functions
10. You can use the advanced settings to switch additional functions on or
off. To do this, switch on the lamp. Hold down the switch for about eight
seconds. The switch flashes once, then twice. Release the switch when it has
blinked twice.
Now tap the switch briefly several times to activate or deactivate functions.
If you want to activate or deactivate another function, start the process
again from the beginning (10.).
With a single tap, the Memory Mode is switched on or off (see also No. 5).
If you tap it twice, the Low Battery Warning is switched on or off (see also
No. 8). If you tap it three times, the Emergency Mode is switched on or off.
When the emergency mode is active, the lamp is switched on automatically if it
is disconnected from the power supply while charging. This means that the lamp
comes on automatically in the event of a power failure or is immediately
active when it is removed from the holder.
If you tap the switch four times, the Backup Mode is switched on or off (see
also No. 8).
Reset to factory settings
11. The lamp can be reset to factory settings. To do this, switch on the
lamp. Hold down the switch for about eight seconds. The switch flashes once,
then twice. Release the switch when it has blinked twice. Then press the
switch again for five seconds until it
flashes four times. Now release the switch. The lamp has been reset to the
factory settings and can be used again as usual.
Further Information
12. Further information, tutorials, and accessories can be found on our website. Simply scan the QR code or www.ledlenser.com.
|
---|---
P6R Signature
https://ledlenser.com/product-information/502189| P7R Signature
https://ledlenser.com/product-information/502190
ledlenser.com
Ledlenser GmbH & Co. KG
Kronenstr. 5-7, 42699 Solingen
Phone +49 212/5948-0 Fax +49 212/5948-200
info@ledlenser.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>