FS Managed L2+ Gigabit PoE+ Switches User Guide
- June 6, 2024
- FS
Table of Contents
FS Managed L2+ Gigabit PoE+ Switches User Guide
Introduction
Thank you for choosing S3410 Series Managed PoE+ Switches. This guide is designed to familiarize you with the layout of the switch and describes how to deploy the switch in your network.
Accessories
NOTE : S3410 series PoE+ switches have dust plugs delivered with them. Keep the dust plugs properly and use them to protect idle optical ports.
Hardware Overview
Front Panel Ports
Front Panel Buttons
Back Panels
Front Panel LEDs
Installation Requirements
Before you begin the installation, make sure that you have the followings:
- Phillips screwdriver.
- Standard-sized, 19″ wide rack with a minimum of 1U height available.
- Category 5e or higher RJ-45 Ethernet cables, fiber optical cables and console cable for connecting network devices.
Site Environment:
- Do not operate it in an area that exceeds an ambient temperature of 50°C.
- The installation site must be free from leaking or dripping water, heavy dew, and humidity.
- Ensure rack and working platforms are well earthed.
- Standard-sized, 19″ wide rack with a minimum of 1U height available.
- Be sure that the switch is level and stable to avoid any hazardous conditions.
- Do not install the equipment in a dusty environment.
Mounting the Switch
Desk Mounting
- Attach four rubber pads to the bottom.
- Place the chassis on a desk.
Rack Mounting
1. Secure the mounting brackets to the two sides of the switch with the supplied M4 screws.
2. Attach the switch to the rack using four M6 screws and cage nuts.
Wall Mounting
1. Secure the mounting brackets to the two sides of the switch with the supplied M4 screws.
2. Use the expansion screws to securely attach the mounting brackets on the wall.
NOTE : Suitable for mounting on concrete or other non-combustible surface only.
Installing the Power Supply Module
S3410-24TS-P/S3410-48TS-P
1. Take a new power module out of the package and confirm the input mode and
the input parameters of the power module match the requirements.
2. Remove the old power module and take the plane printed with power
information as the top panel of the power module. Hold the handle of the power
module with one hand, and hold the end of the power module with the other
hand. Insert it into the chassis along the guide rail uprightly and slowly
until it clicks into place, and make sure that it is in good contact with the
power slot.
NOTE : 1. S3410-10TF-P switch has one built-in power supply. 2. Insert the power module steadily. Please pay attention to the direction of the power panel to avoid wrong insertion. If the position is not proper, press the plug of the power module and hold on to the module handle with one hand to pull it out slowly, then re-insert it.
Grounding the Switch
- Connect one end of the grounding cable to a proper earth ground, such as the rack in which the switch is mounted.
- Secure the grounding lug to the grounding point on the switch back panel with the washers and screws
CAUTION : The earth connection must not be removed unless all supply connections have been disconnected.
Connecting the Power
- Plug the AC power cord into the power port on the back of the switch.
- Connect the other end of the power cord to an AC power source.
WARNING : Do not install power cable while the power is on.
Connecting the RJ45 Ports
- Connect an Ethernet cable to the RJ45 port of IP cameras, IP telephone, Access Points (AP), or other network devices.
- Connect the other end of the Ethernet cable to the RJ45 port of the switch.
Connecting the SFP/SFP+ Ports
- Plug the compatible SFP/SFP+ transceiver into the SFP/SFP+ port.
- Connect a fiber optic cable to the fiber transceiver. Then connect the other end of the cable to another fiber device.
WARNING : Laser beams will cause eye damage. Do not look into bores of optical modules or optical fibers without eye protection.
Connecting the Console Port
- Insert the RJ45 connector into the RJ45 console port on the front of the switch.
- Connect the DB9 female connector of the console cable to the serial port on the computer.
Stacking the Switches
S3410-24TS-P/S3410-48TS-P
The S3410-24TS-P/S3410-48TS-P switches support stacking up to 4 switches between the same series together. The switches can be physically stacked using optical fiber cables connected to SFP+ transceivers or 10G Direct Attach Cables (DAC). S3410-24TS-P switch supports ports 25 & 26 for physical stacking. S3410-48TS-P switch supports port 49 & 50 for physical stacking.
NOTE : S3410-10TF-P switch can’t be stackable.
Configuring the Switch
Configuring the Switch Using the Web-based Interface
Step 1: Connect the computer to any Ethernet port of the switch using the
network cable.
Step 2: Set the IP address of the computer to 192.168.1.x. (“x” is any
number from 2 to 254.). Set the subnet mask of the computer to
255.255.255.0.
Step 3: Open a browser, type http://192.168.1.1, and enter the default username and password, admin/admin.
Step 4: Click Login to display the web-based configuration page.
Configuring the Switch Using the Console Port
Step 1: Connect a computer to the switch’s console port using the console
cable.
Step 2: Start the terminal simulation software such as HyperTerminal on the
computer.
Step 3: Set the parameters of the HyperTerminal: 9600 bits per second, 8 data
bits, no parity, 1 stop bit and no flow control.
Step 4: After setting the parameters, click Connect to enter.
Troubleshooting
Serial port console has no output or outputs illegible characters
1. Change the serial port opened by the configuration software to be the one
connected to the switch.
2. Check that the parameter configuration of the serial port matches that
specified in the instructions.
1/10G Port is not Working
In the case of compatible cables and transceivers, the port cannot be up, please try to modify the port mode to adapt or force the port speed to 1/10G.
Connecting the Switch Remotely Unsuccessfully
- Test network connectivity through ping.
- If the network is reachable, try restarting the switch.
- Check if the corresponding service is enabled.
The Port is not Working, the LED Indicator is Off
- Ensure the switch ports are in the no shutdown state.
- Check if the switch can read the DDM information.
- Check if the port speed setting is correct.
- Try looping the switch cable.
RJ45 port is not in connectivity or it is erroneous in receiving/transmitting frames
- Replace the twisted pair cable.
- Check that the port configuration has the common working mode with the connected switch.
Support and Other Resources
- Download https://www.fs.com/download.html
- Help Center https://www.fs.com/service/help_center.html
- Contact Us https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that any damage or faulty items due to our workmanship, we will offer a free return within 30 Days from the day you receive your goods. This excludes any custom made items or tailored solutions.
Warranty: S3410 Series Switches enjoy 5 years limited warranty against defect in materials or workmanship. For more details about warranty, please check at https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be found at https://www.fs.com/policies/day_return_policy.html
Q.C. PASSED
Copyright © 2020 FS.COM All Rights Reserved.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>