FORTRESS 56339 4 Gallon 200 PSI High Performance Hand Carry Jobsite Air Compressor Owner’s Manual

June 6, 2024
FORTRESS

FORTRESS 56339 4 Gallon 200 PSI High Performance Hand Carry Jobsite Air
Compressor - logo HIGH-PERFORMANCE SERIES
AIR COMPRESSOR
Owner’s Manual & Safety Instructions

FORTRESS 56339 4 Gallon 200 PSI High Performance Hand Carry Jobsite Air
Compressor 4 GALLON
OIL FREE – PORTABLE
Visit our website at: http://www.harborfreight.com
Email our technical support at: productsupport@harborfreight.com

Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product’s serial number in the back of the manual near the assembly diagram (or month and year of purchase if the product has no number). Keep this manual and the receipt in a safe and dry place for future reference. 20k

When unpacking, make sure that the product is intact and undamaged. If any parts are missing or broken, please call 1-888-866-5797 as soon as possible.

Copyright© 2020 by Harbor Freight Tools®. All rights reserved.
No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, the actual product may differ slightly from the product described herein. Tools required for assembly and service may not be included.

Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.

WARNING SYMBOLS AND DEFINITION

| This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
---|---
| Indicates a hazardous situation that, if not avoided, will result in death or serious injury.
| Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
| Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.
| Addresses practices not related to personal injury.

IMPORTANT SAFETY INFORMATION

General Safety Warnings

The warninG read all safety warnings and instructions.
Failure to follow the warnings and instructions may result in electric shock, fire, and/or serious injury.
Save all warnings and instructions for future reference.

The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors that cannot be built into this product but must be supplied by the operator.

  1. Work area safety
    a. Keep the work area clean and well-lit.
    Cluttered or dark areas invite accidents.
    b. Do not operate the compressor in explosive atmospheres, such as in the presence of flammable liquids, gases or dust.
    Compressor motors produce sparks that may ignite dust or fumes.
    c. Keep children and bystanders away from an operating compressor.

  2. Electrical safety
    a. compressor plugs must match the outlet.
    never modify the plug in any way.
    Do not use any adapter plugs with grounded compressors. Standard plugs and matching outlets will reduce risk of electric shock.
    b. Do not expose compressor to rain or wet conditions. Water entering a compressor will increase the risk of electric shock.
    c. Do not abuse the cord. never use the cord for unplugging the compressor.
    Keep cord away from heat, oil, sharp edges, or moving parts. Damaged or entangled cords increase the risk of electric shock.

  3. personal safety
    a. Stay alert, watch what you are doing, and use common sense when operating this compressor. Do not use this compressor while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention while operating a compressor may result in serious personal injury.
    b. Use personal protective equipment. always wear ANSI-approved eye protection during setup and use.
    c. prevent unintentional starting. Ensure the switch is in the off- position before connecting to a power source or moving the compressor.

  4. compressor use and care
    a. Do not use the compressor if the switch does not turn it on and off. Any compressor that cannot be controlled with the switch is dangerous and must be repaired.
    b. Disconnect the plug from the power source before making any adjustments, changing accessories, or storing the compressor. Such preventive safety measures reduce the risk of starting the compressor accidentally.
    c. Store an idle compressor out of the reach of children and do not allow persons unfamiliar with the compressor or these instructions to operate it. A compressor is dangerous in the hands of untrained users.
    d. Maintain the compressor. Keep the compressor clean for better and safer performance. Follow instructions for lubricating and changing accessories.
    Keep dry, clean, and free from oil and grease.
    check for misalignment or binding of moving parts, breakage of parts, and any other condition that may affect the compressor’s operation. if damaged, have the compressor repaired before use.  Many accidents are caused by a poorly maintained compressor.
    e. Use the compressor in accordance with these instructions, taking into account the working conditions and the work to be performed. Use of the compressor for operations different from those intended could result in a hazardous situation.

  5. Service
    a. Have your compressor serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the compressor is maintained.

Air compressor Safety Warnings

  1. risk of fire or explosion – do not spray flammable liquid in a confined area or towards a hot surface.
    Spray area must be well-ventilated. Do not smoke while spraying or spray where spark or flame is present. arcing parts – keep compressor at least 20 feet away from explosive vapors, such as when spraying with a spray gun.

  2. risk of bursting – do not adjust regulator higher than the marked maximum pressure of attachment.

  3. risk of injury – do not direct air stream at people or animals.

  4. Do not use to supply breathing air.

  5. Do not leave the compressor unattended for an extended period while plugged in.
    Unplug the compressor after working.

  6. Keep compressor well-ventilated.
    Do not cover the compressor during use.

  7. Drain Tank daily and after use. Internal rust causes tank failure and explosion.

  8. Do not remove the valve cover or adjust internal components.

  9. The compressor head gets hot during operation.
    Do not touch it or allow children nearby during or immediately following the operation.

  10. Do not use the air hose to move the compressor.

  11. Release the pressure in the storage tank before moving.

  12. The use of accessories or attachments not recommended by the manufacturer may result in a risk of injury to persons.

  13. All airline components, including hoses, pipes, connectors, filters, etc., must be rated for a minimum working pressure of 150 PSI, or 150% of the maximum system pressure, whichever is greater.

  14. USE OF AN EXTENSION CORD IS NOT RECOMMENDED. If you choose to use an extension cord, use the following guidelines:
    TABLE A: RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS (120 VOLT)

    NAMEPLATE AMPERES (at full  load)| EXTENSION CORD LENG TH
    25′| 50′| 100′| 150′
    0 — 6| 18| 16| 16| 14
    6/1/10| 18| 16| Do not use.
    10.1 — 12| 16| 16| Do not use.
    12.1 — 16| 14| 12| Do not use.

a. Make sure your extension cord is in good condition.
b. Be sure to use an extension cord that is heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. Table A shows the correct size to use depending on cord length and nameplate ampere rating. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

  1. Industrial applications must follow OSHA guidelines.

  2. Maintain labels and nameplates on the compressor. These carry important safety information. If unreadable or missing, contact Harbor Freight Tools for a replacement.

  3. This product is not a toy.
    Keep it out of reach of children.

  4. People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to the heart pacemakers could cause pacemaker interference or pacemaker failure.

SAVE THIS INSTRUCTION

Grounding

TO PREVENT ELECTRIC SHOCK AND DEATH FROM INCORRECT GROUNDING WIRE CONNECTION:
Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the compressor. Never remove the grounding prong from the plug. Do not use the compressor if the power cord or plug is damaged. If damaged, have it repaired by a service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician.

110-120 Vac Grounded compressors: compressors with three-prong plugs

  1. In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This  compressor is equipped with an electric cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into a  matching outlet that is properly installed and grounded in accordance with all local codes and ordinances.

  2. Do not modify the plug provided –if it will not fit the outlet, have the proper outlet installed by a qualified electrician.

  3. Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipment grounding conductor to a live terminal.

  4. Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded.

  5. Use only 3-wire extension cords that have 3-prong grounding plugs and 3-pole receptacles that accept the compressor’s plug.

  6. Repair or replace damaged or worn cord immediately.
    FORTRESS 56339 4 Gallon 200 PSI High Performance Hand Carry Jobsite Air
Compressor - figure 1 125 Vac 3-prong plug and Outlet (for up to 125 Vac and up to 15 a)

  7. This compressor is intended for use on a circuit that has an outlet that looks like the one illustrated above in the 125 Vac 3-prong plug and Outlet. The compressor has a grounding plug that looks like the plug illustrated above in the 125 Vac 3-prong plug and Outlet.

  8. The outlet must be properly installed and grounded in accordance with all codes and ordinances.

  9. Do not use an adapter to connect this compressor to a different outlet.

Symbology

PSI Pounds per square inch of pressure
CFM Cubic Feet per Minute flow
SCFM Cubic Feet per Minute flow

at standard conditions
NPT| National pipe thread, tapered
NPS| National pipe thread, straight
| Double Insulated
V| Volts
| Alternating Current
A| Amperes

Specifications

Electrical Rating 120VAC / 60Hz / 14A
Air Outlet Size 1/4″ – 18 NPT
Air Pressure Shut-off
Restart 160 PSI
Air Tank Capacity 4 Gallons
Air Flow Capacity 4.0 SCFM @ 90 PSI
Sound Level 80 dBA

Installation

Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION: Turn the Power Switch “OFF” and unplug the Air Compressor from its electrical outlet before assembling or making any adjustments to the Air Compressor.
Note: For additional information regarding the parts listed in the following pages, refer to the Assembly Diagram near the end of this manual.

Functions

FORTRESS 56339 4 Gallon 200 PSI High Performance Hand Carry Jobsite Air
Compressor - figure 2

Breaking in the air compressor
  1. Turn Power Switch OFF (O) and unplug Power Cord.
    FORTRESS 56339 4 Gallon 200 PSI High Performance Hand Carry Jobsite Air
Compressor - figure 3

  2. Fully open Regulator.FORTRESS 56339 4 Gallon 200 PSI High Performance Hand Carry Jobsite Air Compressor - figure 4

  3. Fully open Drain Valve.
    FORTRESS 56339 4 Gallon 200 PSI High Performance Hand Carry Jobsite Air
Compressor - figure 5

  4. Plug-in Power Cord.

  5. Turn Power Switch ON (I).

  6. Let the unit run for 10 minutes. Air will expel freely through the Drain Valve.

  7. Turn Power Switch OFF.

  8. Unplug Power Cord and close the Drain Valve.

Compressor area Set Up
  1. Designate a work area that is clean and well-lit.
    The work area must not allow access by children or pets to prevent injury.

  2. Locate the Air Compressor on a flat level surface to ensure proper pump lubrication and to prevent damage to the unit. Keep at least 12″ of space around the unit to allow air circulation.

  3. Route the power cord from the Air Compressor to the grounded wall outlet, along a safe path without creating a tripping hazard or exposing the power cord to possible damage.

Air connection Setup
  1. Connect a regulator valve, an inline shut-off valve, and a 1/4″ NPT air hose to the Quick Coupler (all sold separately). The air hose must be long enough to reach the work area with enough extra length to allow free movement while working.
  2. Depending on the tool that will be used with this compressor, incorporate additional components, such as an in-line oiler, a filter, or a dryer (all sold separately), as shown on Figure A on page 8. Consult the air tool’s manual for needed accessories.

Note: an in-line shutoff ball valve is an important safety device because it controls the air supply even if the air hose is ruptured. the shutoff valve should be a ball valve because it can be closed quickly.

INSTALLATION

FORTRESS 56339 4 Gallon 200 PSI High Performance Hand Carry Jobsite Air
Compressor - figure 6

| Description| Function
---|---|---
A| Air Hose| Connects air to the tool
B| Filter| Prevents dirt and condensation from damaging tool or workpiece
C| Regulator| Adjusts air pressure to the tool
D| Lubricator (optional)| For air tool lubrication
E| Coupler and Plug| Provides quick connection and release
F| Leader Hose (optional)| Increases coupler life
G| Air Cleaner/ Dryer (optional)| Prevents water vapor from damaging the workpiece
H| Air Adjusting Valve (optional)| For fine-tuning airflow at the tool

Operating instructions

Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

General Operation

  1. Close Drain Valve.
    FORTRESS 56339 4 Gallon 200 PSI High Performance Hand Carry Jobsite Air
Compressor - figure 7

  2. Close Regulator.
    FORTRESS 56339 4 Gallon 200 PSI High Performance Hand Carry Jobsite Air
Compressor - figure 8

  3. Plug Power Cord into a grounded 120VAC electrical outlet.

  4. Turn Power Switch ON (I).
    FORTRESS 56339 4 Gallon 200 PSI High Performance Hand Carry Jobsite Air
Compressor - figure 3

  5. Allow Air Compressor to build up pressure until it cycles off.
    Note: At the beginning of the day’s first use of the Air Compressor, check for air leaks by applying soapy water to connections while the Air Compressor is pumping and after pressure cut-out. Look for air bubbles. If air bubbles are present at connections, tighten connections. Do not use the Air Compressor unless all connections are airtight, the extra air leaking out will cause the Air Compressor to operate too often, increasing wear on the Air Compressor.
    Note: As long as the Power Switch is ON, the operation of the Air Compressor is automatic, controlled by an internal pressure switch. The Air Compressor will turn on automatically when the air pressure drops to 160 PSI and will turn off automatically when the air pressure reaches 200 PSI.
    WARNING! TO PREVENT SERIOUS INJURY AND DEATH FROM EXPLOSION: Do not adjust the internal pressure switch Any change to the automatic pressure levels may cause excess pressure to accumulate, causing a hazardous situation.

  6. Make sure the air tool’s throttle or switch is in the OFF position. Connect the air tool to the air hose.

  7. Adjust the Regulator Knob so that the air output is enough to properly power the tool, but the output will not exceed the tool’s maximum air pressure at any time. Turn the knob clockwise to increase the pressure and counter-clockwise to decrease pressure. Adjust the pressure gradually, while checking the Outlet Pressure gauge to set the pressure.

  8. Use the air tool as needed.

  9. When finished, turn the Power Switch OFF.

  10. Unplug the Air Compressor.

  11. Bleed air from the tool then disconnects the tool.

  12. Open the tank’s Drain Valve slowly to gradually release tank pressure and any built-up moisture.
    Close the Drain after air and moisture have drained out. Do not remove the Drain Valve.

  13. Clean, then store the Air Compressor indoors.

Emergency Depressurization

If it is necessary to quickly depressurize the Air Compressor, turn the Power Switch OFF. Then, pull on the ring on the Safety Valve to quickly release stored air pressure.FORTRESS 56339 4 Gallon 200 PSI High Performance Hand
Carry Jobsite Air Compressor - figure 9

Automatic Shut off System

  1. If the Air Compressor automatically shuts off
    before reaching its normal cutoff pressure:
    a. Shut off all tools.
    b. Turn Power Switch to OFF position.
    c. Unplug Air Compressor.
    d. Wait until the Air Compressor
    cools down (about 10 minutes).
    e. Plug Air Compressor in.
    f. Turn Power Switch to ON.
    g. Resume operation.

  2. Possible causes of repeated automatic shut off of the Air Compressor are:
    a. Using an extension cord that is too long or narrow;
    b. An air leak or open hose causing the Air Compressor to cycle too often and build up heat;
    c. Turning Air Compressor off and on again too quickly.

  3. Correct any issues before further use to avoid damage to the Air Compressor.

Maintenance and Servicing

Procedures not specifically explained in this manual must be performed only by a qualified technician.

TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION: Turn the Power Switch “OFF” and unplug the Air Compressor from its electrical outlet before performing any inspection, maintenance, or cleaning procedures.
TO PREVENT SERIOUS INJURY FROM AIR COMPRESSOR FAILURE: Do not use damaged equipment. If abnormal noise or vibration occurs, have the problem corrected before further use.

Cleaning, Maintenance, and lubrication

  1. BEFOrE EacH USE, inspect the general condition of the air Air Compressor. Check for:
    • loose hardware,
    • misalignment or binding of moving parts,
    • cracked or broken parts,
    • damaged electrical wiring, and
    • any other condition that may affect its safe operation.

  2. AFTER USE, wipe external surfaces of the Air Compressor with a clean cloth.

  3. WARNING! TO PREVENT SERIOUS INJURY: If the supply cord of this Air Compressor is damaged, it must be replaced only by a qualified service technician.

Maintenance Schedule

Following are general guidelines for maintenance checks of the Air Compressor.
Note  The environment in which the Air Compressor is used, and the frequency of use will affect how often you will need to check the Air Compressor components and perform maintenance procedures.

Daily:
a. Make sure all nuts and bolts are tight.
b. Drain moisture from air tank.
c. Check for abnormal noise or vibration.
d. Check for air leaks.
e. Wipe off any oil or dirt from the Air Compressor.

Monthly:
a. Inspect Safety Valve.

  • To check for air leaks, apply soapy water to joints while the Air Compressor is pressurized. Look for air bubbles.

Draining Moisture from the air tank

The Moisture Drain is located under the Tank. It must be used daily to release all trapped air and moisture from the Tank. Doing this will eliminate condensation and prevent tank corrosion.

  1. Turn the Power Switch OFF.
    2. Turn the Drain Valve to open it.
    3. When all the pressure and moisture is released, close the Moisture Drain.

Air Filter Maintenance

  1. Remove Air Inlet Filter from the back of air compressor by turning it counterclockwise.

  2. Remove Cover from Air Inlet Filter.

  3. Check Filter for accumulated dirt.
    FORTRESS 56339 4 Gallon 200 PSI High Performance Hand Carry Jobsite Air
Compressor - figure 10

  4. cleaning:
    a. To prevent injury from dust and debris, wear ANSI-approved safety goggles, NIOSH-approved dust mask/respirator, and heavy-duty work gloves. In a well- ventilated area away from bystanders, use pressurized air (no more than 15 PSI) to blow dust out of the filter.
    b. Replace the clean filter. Replace the cover, making sure the Tube is facing down.

  5. Replacements:
    a. Air Inlet Filter only: Paper Filter Element 2-1/4″ Outer Diameter.
    b. Air Inlet Filter Assembly: Inlet Filter Silencer Male 1/4″ NPT.

PLEASE READ THE FOLLOWING CAREFULLY

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE  TOOL ONLY. NEITHER THE MANUFACTURER NOR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE  PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD  BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER  INSTALLATION OF REPLACEMENT PARTS THERETO.

Troubleshooting

Problem Possible Causes Likely Solutions

Compressor does
not start or restart| 1. Tank(s) already pressurized.
2. Power cord is not plugged in properly.
3. Incorrect power supply.
4. No power at outlet.
5. Thermal overload switch tripped.
6. Building power supply circuit tripped or blown fuse.
7. Cord wire size is too small or cord is too long to properly power compressor.
8. Compressor needs service.| 1.No problem. The compressor will start when needed.
2. Check that cord is plugged in securely.
3. Check that the circuit matches compressor requirements.
4. Reset circuit breaker, or have outlet serviced by a qualified technician.
5. Turn off Compressor and wait for it to cool down. Press the reset button. Resume operation.
6. Reset the circuit or replace the fuse. Check for low voltage conditions. It may be necessary to disconnect other electrical appliances from the circuit or move the compressor to its own circuit.
7. Use a larger diameter or shorter extension cord or eliminate the extension cord. See Recommended Wire Gauge for Extension Cords in Safety section.
8. Have the unit inspected by a qualified technician.
Compressor builds pressure too slowly| 1. Incorrect power supply.
2. Working environment too cold.
3. Safety valve leaking.
4. Loose fittings.| 1. Check that the circuit matches compressor requirements.
2. Move the compressor to a warmer location.
3. Listen for air leaking from the valve.
If leaking, replace with an identical valve with the same rating. DO NOT SEAL OR TAMPER WITH THE SAFETY VALVE.
4. Reduce air pressure, then check all fittings with a soap solution for air leaks and tighten them as needed. Do not overtighten.
Compressor not building enough air pressure| 1. Check Valve needs service.
2. Compressor not large enough for the job.
3. Loose fittings.
4. Hose or hose connections too narrow.
5. High altitude reducing air output.| 1. Have technician clean or replace, as needed.
2. Check if accessory CFM is met by Compressor. If the Compressor cannot supply enough airflow (CFM), use a larger Compressor.
3. Reduce air pressure, then check all fittings with a soap solution for air leaks and tighten them as needed. Do not overtighten.
4. Replace with wider hose and/or hose connections.
5. Higher altitudes require compressors with greater output.
Overheating| 1. Unusually dusty environment.
2. Extension cord used.| 1. Move unit to cleaner environment.
2. Eliminate extension cord.
Compressor
starts and stops excessively| 1. Loose fittings.
2. Compressor not large enough for the job.| 1. Reduce air pressure, then check all fittings with a soap solution for air leaks and tighten them as needed. Do not overtighten.
2. Check if accessory SCFM is met by Compressor. If the Compressor cannot supply enough airflow (SCFM), use a larger Compressor.
Excessive noise| Loose fittings.| Reduce air pressure, then check all fittings with a soap solution for air leaks and tighten as needed. Do not overtighten.
Moisture in the discharge air| Too much moisture in the air.| Install an inline air filter/dryer, and/or relocate to a less humid environment.
Safety Valve “pops”| Safety valve needs service.| Pull-on the ring on the Safety Valve. If it still pops, replace.
Air leaks from pump or fittings| Loose fittings.| Reduce air pressure, then check all fittings with a soap solution for air leaks and tighten as needed. Do not overtighten.
Air leaks from tank| Defective or rusted tank.| Has the tank been replaced by a qualified technician?
Drain moisture from the tank daily to prevent future corrosion.
Follow all safety precautions whenever diagnosing or servicing the compressor. Disconnect power supply before service.

Parts List and Diagram

Parts list

Part Description Qty
1 Air Filter 1
2 Bolt M6x90 4
3 Head 1
4 Elbow 1
5 Funnel 4
6 Pipe Nut 4
7 Gasket 1
8 Valve Plate 2
9 Reed Valve 2
10 Cylinder Sealing Ring 1
11 Cylinder 1
12 Bolt M6x16 1
13 Press Block 1
14 Upper Piston Ring 1
15 Lower Piston Ring 1
16 Connecting Rod 1
17 Screw 2
18 Press Plate 1
19 Micro Pressure Switch 1
20 Plug 1
21 Left Shroud 1
22 Bolt M5x16 4
23 Washer 4
24 Nut M5 4
25 Check Valve 1
26 Copper Tube 1
27 Safety Valve 1
28 Nut M6 3
29 Bolt M6x14 7
30 Panel 1
31 Tank Pressure Gauge 1
32 Outlet Pressure Gauge 1
33 Nut M6 5
34 Quick Connect 2
35 Regulator Assembly 1
36 Connector 1
37 Hose Clamp 2
38 Hose 1
39 Elbow 2
40 Bushing 2
41 Pipe 1
42 Tank 1
43 Drain Valve 1
44 Feet 4
45 Washer 4
46 Bolt M6x16 4
47 Spring Washer 3
48 Bolt M4x8 3
49 Bolt M6x16 1
50 Washer 1
51 Fan 1
52 Bearing 1
53 Belt 1
54 Pulley 1
55 Bearing 1
56 Bearing 1
57 Snap Ring 1
58 Bolt M6x25 4
59 Washer 4
60 Bushing 4
61 Cushion 4
62 Crank Case 1
63 Screw 7
64 Right Shroud 1
65 Power Switch 1
66 Brush Case 2
67 Coil Spring 2
68 Brush Holder 1
69 Bolt M5x100 2
70 Fan 1
71 Vent 1
72 Baffle Ring 1
73 Bearing 2
74 Rotor 1
75 Pulley 1
76 Stator 1
77 Bolt M6x30 1
78 Spring Washer 2
79 Washer 2
80 Nut M6 1
81 Power Cord 1
82 Grip 1

Record product’s Serial number Here:
Note:
If the product has no serial number, record the month and year of purchase instead.
Note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. Parts may not be interchangeable. Specify number when ordering Specify UPC 193175371263 when ordering parts.

Assembly Diagram

FORTRESS 56339 4 Gallon 200 PSI High Performance Hand Carry Jobsite Air
Compressor - figure 11

Limited 90 Day Warranty

Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase. This warranty does not apply to damage due directly or indirectly, to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity, improper installation, normal wear, and tear, or to lack of maintenance. We shall in no event be liable for death, injuries to persons or property, or for incidental, contingent, special or consequential damages arising from the use of our product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation of exclusion may not apply to you. THIS WARRANTY IS  EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS.

To take advantage of this warranty, the product or part must be returned to us with transportation charges prepaid. Proof of purchase date and an explanation of the complaint must accompany the merchandise. If our inspection verifies the defect, we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement. We will return repaired products at our expense, but if we determine there is no defect, or that the defect resulted from causes not within the scope of our warranty, then you must bear the cost of returning the product.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

FORTRESS 56339 4 Gallon 200 PSI High Performance Hand Carry Jobsite Air
Compressor - logo

Item 56339
For technical questions, please call 1-888-866-5797.
26541 agoura road • calabasas, ca 91302 • 1-888-866-5797

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

FORTRESS User Manuals