Product overview

Thank you for choosing Rtelligent R series digital stepper driver.
R series stepper driver, which surpasses the performance of common analog stepper driver comprehensively based on the new 32-bit DSP platform developed by TI, and adopting the micro-stepping technology and PID current control algorithm design. The R series stepper drivers have the features of low noise, low vibration, low heating and high-speed high torque output, it is suitable for most stepper motors by integrated with the micro-stepping technology.

The R42 driver can select the running current and subdivision through the DIP switch. There are 16 subdivisions and 8 current selections. It has overvoltage, undervoltage and overcurrent protection. Its input and output control signals are optically isolated.

Power supply 24 — 48VDC
Output Current Up to 2.2 amps ( peak value)
Current control PID current control algorithm
Micro-stepping settings DIP switch settings, 16 options
Speed range Use the suitable motor, up to 3000rpm
Resonance suppression Automatically calculate the resonance point and inhibit

the IF vibration
Parameter adaption| Automatically detect the motor parameter when driver
initialize, optimize the controlling performance
Pulse mode| Support direction & pulse, CW/CCW double pulse,
Pulse filtering| 2MHz digital signal filter
Idle current| The current is automatically halved after the motor stops running

We hope that our products with excellent performance can help you to complete the sports control program successfully.
Please read this technical manual before using the products.

Application environment and installation

Environmental requirement
Item Rtelligent R42
Installation environment Avoid dust, oil and corrosive environment
Vibration 0.5G (4.9m/s2) Max
Operating temperature/humidity Or – 45r / 90% RH or less (no condensation)
Storage and transportation temperature: -10r – 70r
Cooling Natural cooling / away from the heat source
Waterproof grade IP54
Driver installation dimensions
Driver installation requirements

Please install the driver vertically or horizontally, with its front facing forward, top facing upward to facilitate cooling.
During assembly, avoid drillings and other foreign matters falling inside the driver.
During assembly, please use M3 screw to fix.
When there is vibration source (such as a driller) close to the installation position, please use a vibrating absorber or a vibration resistant rubber gasket.
When multiple drivers are installed in the control cabinet, please pay attention to reserve enough space for sufficient heat dissipation. If necessary, you can configure cooling fans to ensure good heat dissipation conditions in the control cabinet.

Driver port and connection

Port function description
Function Grade Definition Remarks
Power supply input port V+ Input DC power positive DC 24-48V
V- Input DC power negative
Motor connection port A+ connect two terminals of motor’ s phase-A winding

A-
B+| connect two terminals of motor’ s phase-B winding
B-
Pulse connection| PUL+| Pulse input interface| 3.3 – 24V level compatible
PUL-
DIR+| Direction input interface
DIR-
Enable connection| ENA+| Enable control interface
ENA-

Power supply input

The driver’s working power is DC power, and the input voltage range is between 24V ~ 48V.
Input power polarity should not be reversed!!!
The driver’s work mode is constant current control. The driver output the voltage to motor by changing the input power into PWM chopping wave when it is working. In this case, the input power will affect the performance of driver.

Power selection reference:
Voltage:
Stepper motor has the characteristics of torque decrease with the increase of motor speed, and the input voltage will affect the amplitude of high-speed torque reduction. Properly increasing the voltage of the input power supply can increase the output torque of the motor at high speed.
Therefore, if you want to get better high-speed performance, pls increase the power supply voltage of the driver; and for low-speed applications, choosing a slightly smaller voltage can appropriately reduce the heat of the motor.

Current:
The working process of the driver is to convert the input high-voltage and low-current power supply into the low-voltage and high-current at both ends of the motor winding. In actual use, the appropriate power supply should be selected according to the motor model, load torque and other factors.

The effects of regeneration voltage:
When the stepper motor is working, it also retains the characteristics of the generator. When decelerating, the kinetic energy accumulated by the load will be converted into electrical energy and superimposed on the driver circuit and input power supply.
Pay attention to the setting of acceleration and deceleration time to protect the driver or power supply.
When the driver is powered off, you will see the driver’s LED indicator on when the load is pulled to make the motor move, which is also affected by this.

Motor connection

The matching motor of the R42 driver is the low resistance and low inductance hybrid stepper motor.
The common 2-phase stepper motor’s lead number are 4, 8 and 6.
There is only one connection mode for 4 leads motor.
Series and parallel connection mode are used by 8 leads motor:
When series used, the winding inductance increased. The set of driver current should be about 0.7times than before. This is suitable for low speed required.
When parallel used, the winding inductance decreased. The set of driver current should be about 1.4times than before. This is suitable for high speed required.
Parallel and central tapping connection mode are used by 6 leads motor:
When parallel used, all the winding connected, and the inductance was higher. This is suitable for low speed required.
When central tapping used, half of the winding connected, and the inductance was lower. This is suitable for high speed required.

Control signal connection
  1. PUL, DIR port: connection for pulse command
    The standard R series driver signal interface is in the form of pulse, and R42 can receivetwo pulse command signals.
    The upper controller can be the pulse signal generating device, such as PLC, MCU, control card and controller.
    The pulse level that R42 driver can be used: 3.3V-24V (no need to connect resistor)Pulse and direction (PUL + DIR)|
    ---|---
    Double pulse (CW +CCW)|

  2. ENA port: used to enable or disable
    When the internal optocoupler is off, the driver outputs current to the motor;
    When the internal optocoupler is on, the driver will cut off the current of each phase of the motor to make the motor free, and the step pulse will not be responded.
    When the motor is in error state, ENA input can be used to restart the driver. Firstly, the fault is eliminated, and then a falling edge signal is input to the ENA terminal. The driver can restart the power part and the motor is excited.
    The level logic of the ENA signal can be set to the opposite, with the logic being opposite to the above.

  3. Examples for control signal connection
    Common Anode
    Common Cathode
    Difference

The setting of DIP switches and operating parameters

The setting of current

Peak Current| Average Current| SW1| SW2| SW3| Remarks
---|---|---|---|---|---
0.3A| 0.2A| on| on| on| Other Current be
can customize ed
0.5A| 0.3A| off| on| on
0.7A| 0.5A| on| off| on
1.0A| 0.7A| off| off| on
1.3A| 1.0A| on| on| off
1.6A| 1.2A| off| on| off
1.9A| 1.4A| on| off| off
2.2A| 1.6A| off| off| off

DIP SW1, SW2, SW3 are used to set current which is output from driver to motor.
Generally, the current is set to the rated current of the motor. If your system has high request to the heating, please decrease the current properly to lower the motor’s heating, but at the same time, the output torque will be lower. If you don’t need the motor running continuous, you can increase the current to higher the torque. But be minded that the current can not be 1.5times over than the rated current.

The setting of pulse per revolution
Steps/revolution SW5 SW6 SW7 SW8 Remarks
200 on on on on Customizable other pulse per revolution
400 off on on on
800 on off on on
1600 off off on on
3200 on on off on
6400 off on off on
12800 on off off on
25600 off off off on
1000 on on on off
2000 off on on off
4000 on off on off
5000 off off on off
8000 on on off off
10000 off on off off
20000 on off off Off
25000 off off off off

DIP SW5, SW6, SW7, and SW8 are used to set the pulse per revolution required by the motor.
Motor speed = command pulse frequency / per revolution pulse
Motor stroke = number of command pulses / pulse per revolution

Half / full flow selection

DIP SW4 is used to set the static current value when the motor is stopped
Off means that when the driver’s power-on pulse stops, the driver switches the current output to the motor to half (half current) when it is rotating;
On means that when the driver’s power-on pulse stops, the driver maintains the same current output to the motor as the rotation (full current) ). In general use, SW4 should be set to off, so that the heat of the motor and driver is reduced, and the reliability is improved.

Driver working status LED indication

LED status Driver status
Green indicator is on for long time Driver not enabled
Green indicator is flickering Driver working normally
One green indicator and one red indicator Driver overcurrent
One green indicator and two red indicators Driver input power overvoltage
One green indicator and three red indicators The internal voltage of the

driver is wrong

Common faults and troubleshooting

Phenomenon Possible situations Solutions
Motor does not work Power indicator is off Check the power supply

circuit for normal power supply
The motor rotor is locked but the motor does not work| Pulse signal is weak; increase the signal current to 7-16mA
The speed is too slow| Select the right micro-stepping
Driver is protected| Solve the alarm and re-power
Enable signal problem| Pull up or disconnect the enable signal
Command pulse is incorrect| Check whether the upper computer has pulse output
The steering of motor is
wrong| The rotary direction of motor is reverse| Adjust the DIP SW5
The motor cable is disconnected| Check the connection
The motor has only one direction| Pulse mode error or DIR port damaged
Alarm| The motor connection is wrong| Check the motor connection
indicator is on| The motor connection and encoder connection are wrong| Check the sequence of encoder connection
---|---|---
The voltage is too high or too low| Check the power supply
The position or speed is
wrong| The signal is disturbed| Eliminate interference for reliable grounding
The command input is incorrect| Check the upper computer
instructions to ensure the output is correct
The setting of Pulse per revolution is wrong| Check the DIP switch status and correctly connect the switches
Encoder signal is abnormal| Replace the motor and contact the manufacturer
The driver terminal
burned up| Short circuit between terminals| Check power polarity or external short circuit
Internal resistance between terminals is too large| Check whether there is any solder ball due to excessive addition of solder on the wire connections
The motor is out of
tolerance| Acceleration and deceleration time is too short| Reduce command acceleration or increase driver filtering parameters
Motor torque is too low| Select the motor with high torque
The load is too heavy| Check the load weight and quality and adjust the mechanical structure
The current of power supply is too low| Replace the appropriate power supply

Guarantee clause

Warranty period: 12 months

We provide quality assurance for one year from the date of delivery and free maintenance service for our products during the warranty period.

Exclude the following:
  • Improper connection, such as the polarity of the power supply is reversed and insert/pull the motor connection when the power supply is connected.
  • Beyond electrical and environmental requirements.
  • Change the internal device without permission.
Maintenance process

For maintenance of products, please follow the procedures shown below:
(1) Contact our customer service staff to get the rework permission.
(2) The written document of the driver failure phenomenon is attached to the goods, as well as the contact information and mailing methods of the sender. Mailing address: Post code: Tel.: