Important Safety Instructions

 | WARNING: If the instructions contained in this manual are not followed precisely, fire or explosion may result causing property damage, personal injury or loss of life.

  • Do not store or use gasoline or other flammable vapors or liquids near this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.
  • Do not touch any electrical switches.
  • Do not use any telephones in your building.
  • Immediately call your gas supplier from a neighbor’s phone. Follow the gas        supplier’s instructions.
  • If you cannot reach your gas supplier, call the fire department.
  • Installation and service must be performed by a qualified installer, service company or gas supplier.

READ AND SAVE THESE INSTRUCTIONS – Your safety and the safety of others are very important.

We have provided many important safety message throughout this manual and on the appliance.

Read all the instructions before using the appliance and always obey all safety messages.


RECOGNIZE SAFETY INFORMATION

This is a safety alert symbol. This symbol alerts you to potential hazards that can result in severe personal injury or loss of life.

UNDERSTAND SIGNAL WORDS

A signal word – DANGER, WARNING or CAUTION – is used with the safety alert symbol. DANGER denotes the most serious hazards. It means you could lose your life or be seriously injured if you do not immediately follow the instructions. WARNING means you could lose your life or be seriously injured if the instructions are not followed. CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor to moderate injury.


The safety messages will inform you of potential hazards, on how to avoid the risk of injury and what can occur if the instructions are not followed.

IMPORTANT: Observe all codes and ordinances in force.

WARNING: For your safety, the instructions contained in this manual must be followed to minimize the risk of fire or explosion and to prevent property damage, personal injury or loss of life.


  • This conversion kit must be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction.
  • If the information in these instructions is not followed exactly, a fire, an explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
  • The qualified service agency is responsible for the proper installation of this kit. The Installation is not correct and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.
  • For an installation at altitudes above 2000 ft (610 mt) contact the Service Centre.

I nstallation shall not be considered correct and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with this kit.


IRE HAZARD F

Securely tighten all gas connections. lf connected to LP, have a qualified technician ensure that the gas pressure does not exceed a 14” W.C.P. Examples of qualified technicians include licensed heating personnel, authorized gas company personnel and authorized service personnel.

FAILURE TO DO SO CAN RESULT IN LOSS OF LIFE, EXPLOSION, OR FIRE.


Caution: Before proceeding with the conversion, the gas supply must be shut off prior to disconnecting the electrical power.

Conversion Kit


 **1 List of components**

This conversion kit consists of the following components:

  • One label for LPG injectors

KIT INJECTORS FOR L.P.G. GAS
N°: 691131356 FOR MODE
Injecteurs kit pour le gaz P.L.
N°: 691131356 pour le modele

 **CPFU3OGMX!**

  • One injector Ø 0.60 mm for the Auxiliary burners.
  • One injector Ø 0.80 mm for the Semi-rapid burner.
  • One injector Ø 0.54 mm for the Ultra-rapid burner (internal crown).
  • One injector Ø 1.10 mm for the Ultrarapid burner (external crown)
  • One injector Ø 0.54 mm for the Ultrarapid Dual burner (internal crown).
  • One injector Ø 1.10 mm for the Ultrarapid Dual burner (external crown
  • One warning label change injectors

THIS APPLIANCE WAS CONVERTED ON:
Cet appareil a ete converti le:
(DAY. MONTH. YEARIAjout. mots, an nee)

TO GAS/au gaz___ WITH KR Pravec le kit n°:

BYip at
(name and address of organization making this conversion)
(nom et adresse de I’organisme effectuant cette conversion)
WHICH ACCEPTS THE RESPONSIBILITY THAT THIS
CONVERSION HAS BEEN PROPERLY MADE
Qui accepte la responsabilite que cette conversion
a ete effectuee de maniere adequate

THIS PRESSURE REGULATOR HAS BEEN
CONVERTED FOR USE WITH GAS:
Ce regulateur de pression a ete converti pour
[‘utilisation avec le gaz:Cod g2B49A078

  • One seal gasket 12.5×18.5×2 (mm).

    2 Gas connection

Check that the main gas supply line to the range is shut off and that the power supply cord is disconnected.

 **3 Adaptation to different types of gas**

To adapt the regulator to the type of gas used, the following must be done:

  1. Unscrew the cover of the pressure regulator.
  2. Unscrew the spring retainer from the cover.
  3. Screw the spring retainer back on according to the type of gas used (see the following illustrations).
  •  **Natural Gas:** Set pressure to 5” W.C.P. Incoming line pressure of 6” - 10 1/2” W.C.P maximum.
  • LP Gas: Set pressure to 10” W.C.P. Incoming line pressure 11”- 13” W.C.P. maximum.

  • Incoming line pressure upstream from the regulator must be 1” (2.5 cm) W.C.P. higher than the manifold pressure in order to check the regulator.

The range must be isolated from the gas supply piping system by turning off the respective manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or greater than 1/2 PSIG (3.5 kPa).

 **4 Replacing the rangetop's burners nozzles:**
  1. Remove all the grates and all the burner caps (1) and heads   (2) ;

  2. Unscrew the burner nozzles with a 7 mm socket wrench;

3. Replace the nozzles according to the type of gas to be used and the description in section 3.2 “Burner and nozzle characteristics table”.

Ultra-rapid Dual burner

(A) Internal crown – (B) External crown

  1. Put the burners back in their correct position. Make sure that the holes of the flame-spreader crowns are aligned with the thermocouples (3) and igniters (4).

    5 Test the appliance

Follow these instructions to leak test the appliance: Use a brush and liquid detergent to test all gas connections for leaks. Bubbles around connections indicate a leak. If a leak appears, shut off the gas valve controls and adjust the connections. Then check the connections again. Remove all the detergent product from the range. Replace the parts on the burner and turn the knobs on the gas tap valves.

NEVER TEST FOR GAS LEAKS WITH A MATCH OR OTHER FLAMES.

Check that the flame at the maximum flame position has a blue color. It should be clean and soft in character. No blowing or lifting of flame should occur. Occasional orange flashes are normal and reflect different elements in the air or gas.

Wipe away all the detergent product from the range.
Replace the parts on the burner and turn the knobs on the gas tap valves.

6 Minimum adjustment For natural Gas:

Light the burner and turn the knob to the minimum position . Remove the gas tap
knob and turn the adjustment screw at the side of the tap rod until the desired minimum flame is achieved.

Refit the knob and verify that the burner flame is stable (when turning the knob rapidly from the maximum to the minimum position the flame must not go out).

Repeat this operation on the remaining gas taps on the cooktop.

 **For LP Gas:**
Turn off the burners and unplug the appliance from the electrical power supply.
For regulating the minimum with LP, the screws at the side of the tap rod must be turned clockwise all the way. Once the regulation has been completed, replace the
seal on the by-passes using paint or similar materials. Follow the instructions given in
point 9 to locate the adjustment screws.





 **7 Burner and nozzle characteristics tables**

To adjust the range for LP gas or to return to Natural Gas use, refer to the charts below.

Natural Gas|

AUX

| SR| UR| DUAL int|

DUAL est

---|---|---|---|---|---
QT (BTU)|

4500

| 8000| 20000| 4500|

15500

injector Ø (mm)|

0.90

| 1.20| 0.90 + 1.80| 0.90|

1.75

QR (BTU)

| 1200| 1600| 5200| 800|

4200

LP|

AUX

| SR| UR| DUAL int|

DUAL est

QT (BTU)|

4200

| 7500| 18000| 4000|

14000

Injector Ø (mm)|

0.60

| 0.80| 0.54 + 1.10| 0.54|

1.10

QR (BTU)|

1200

| 1600| 5200| 800| 4200
By-pass (mm)|

0.33

| 0.39| 0.70| 0.30|

0.63

NOTE: Save the nozzles that were removed from the appliance along with these instructions for possible future use.

FIRE HAZARD Use a soapy solution to check that it is leak-tight.

Never test for gas leaks with a match or other flames.

Failure to follow this instruction can result in loss of life or fire.

FIRE HAZARD Use a soapy solution to check that it is leak-tight.

Never test for gas leaks with a match or other flames.

Failure to follow this instruction can result in loss of life or fire.


8 Combustion products

The combustion products may be extracted by means of hoods connected to a natural
draught chimney whose efficiency is certain or via forced extraction. An efficient raction system requires precision planning by a specialist qualified in this area and must comply with the positions and distances indicated by the applicable standards.
When the job is complete, the installer must issue a certificate of conformity.

1 Extraction using a hood
2 Extraction without a hood

A Single natural draught chimney
B Single chimney with extractor fan
C Directly outdoors with wall- or window mounted extractor fan
D Directly outdoors through wall

Air

Combustion products

Extractor fan

 **9 Final operations**
  • Completely fill out the conversion label (part no. 92849A078) and attach it to the rear of the appliance. Do not cover any other labels with the conversion label.
  • Over time the gas taps may become difficult to turn and get blocked. Clean them internally and replace the lubrication grease.

Lubrication of the gas taps should be performed by a specialized technician.

  • Save the nozzles removed from the unit along with these instructions for possible future use.

  • For installation of the appliance at high altitude, please consult your local gas company for their recommendation on the correct orifice sizes and any other necessary adjustments that will provide proper gas combustion at specified altitudes.

    10 Natural Gas

To convert back to Natural Gas, follow steps 1 through 7 and replace the nozzles in the order in which they were removed.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals