Without the written permission of the company, no unit or individual shall extract or copy part or all of the contents of this manual without authorization, and shall not disseminate it in any form. Due to product version upgrades or other reasons, the contents of this manual will be updated from time to time. This manual is only used as a guide,  and all statements, information, and suggestions in this manual do not constitute any express or implied warranty. The company shall not be liable for any special, incidental, accidental, or indirect damage caused by the use of this manual or the use of the company’s products, including but not limited to the loss of business profits, loss of data or documents, abnormal operation of products and information disclosure caused by network attack, hacker attack, virus infection, etc.

Safety instructions

  •  This is a class a product, which may cause radio interference in the living environment. In this case, users may be required to take practical measures against their interference.
  • Please disconnect the power supply before moving the equipment. Be careful to prevent electric shock when moving. Once the power cord is inserted into the power supply, the equipment will be powered on.
  • Please ensure that the equipment is installed stably and reliably, the surrounding ventilation is good, and the ventilation outlet must be unblocked when the equipment is working.
  • Please ensure that the equipment works within the allowable temperature, humidity, and power supply requirements, and is well-grounded to meet the lightning protection requirements, and avoids being placed in dusty, strong electromagnetic radiation, vibration, and other places.
  • Please protect the power cord from trampling or squeezing, especially at the plug, power socket, and contact from the device.
  • After installation, please check the correctness to avoid human injury and equipment component damage due to wrong connection during power on.
  • Abnormal power failure may cause equipment damage or abnormal function. If the equipment is used in an environment of frequent power failure, please provide ups.
  • Make the equipment work within the allowable temperature and humidity range, and avoid being placed in places such as extrusion, vibration, extreme heat, extreme cold, and strong electromagnetic radiation. To avoid fire and electric shock hazards, do not allow water or other liquids to flow into the equipment during use.
  • If the equipment cannot be maintained due to unauthorized operation, the company will not bear all the consequences arising therefrom.

packing list

If you find any items damaged or missing, please contact your local dealer in time.

No item number unit
1 DR21-8UW 1 pcs
2 Tail line – grid port 1 pcs
3 Tail line – full function 1 pcs
4 The power adapter 1 pcs
5 Accompanying instructions 1 pcs
6 certificate 1 pcs
7 warranty card 1 pcs
8 Wall mount bracket set 1 pcs
9 Wall mount bracket sticker 1 pcs
10 Screw package 1 pcs

product introduction

2.1 product description
U82/T82 is a high-performance and reliable product. This product supports a variety of recognition modes such as white list recognition, IC card verification. It adopts the idea of industrial appearance design, with a light and thin body, smooth lines, high recognition rate, large storage capacity, fast recognition, and so on. Through the access management platform, multiple applications such as access control management, attendance management, and visitor management can be realized, which is suitable for various scenarios such as parks, universities, enterprises, communities, and hospitals. Bresee
DR21 8UW U82 8 inch Facial Recognition Door Gate
Terminal

2.2 product dimensions
U82 Equipment dimension drawing, as shown in Figure 2-1. Bresee DR21 8UW U82
8 inch Facial Recognition Door Gate Terminal - product
dimensionsT82 Equipment dimension drawing, as shown in Figure 2-2.

2.3 structure description
The appearance of the U82 equipment structure is shown in Figure 2-3. Please refer to the real object for details. Bresee DR21 8UW U82 8 inch Facial
Recognition Door Gate Terminal - structure description

Serial number name explain
1 Led fill light Fill RGB camera
2 Infrared fill light Fill in light for infrared camera
3 Infrared camera Take infrared images
4 RGB camera Take visible images
5 speaker Play voice prompt
6 Tail line output hole Panel tail line hole

The appearance of the T82 equipment structure is shown in Figure 2-4. Please refer to the real object for details. Bresee DR21 8UW U82 8 inch Facial
Recognition Door Gate Terminal - structure description 1

Serial  number name explain
1 Led fill light Fill RGB camera
2 Infrared fill light Fill in light for infrared came
3 Infrared camera Take infrared images
4 RGB camera Take visible images
5 Mic outlet For voice intercom
6 speaker Play voice prompt
7 Tail line output hole Panel tail line hole

installation instructions

Please check before installing the product to ensure that the product can work normally.
This document provides wall-mounted installation methods for reference, and other installation instructions can be obtained by contacting our  personnel;
3.1 gate-type installationBresee DR21 8UW U82 8 inch Facial Recognition
Door Gate Terminal - gate type installation

chart 3-1

Step 1: as shown in Figure 3-1, if there is no hole on the gate panel, it is necessary to use a punch to make a circle with a diameter of 35mm on the gate panel;
Step 2: as shown in Figure 3-2, thread the external wiring of the identification terminal and the vertical pole support through the hole on the gate panel;
Step 3: as shown in Figure 3-3, thread and tighten the upright nut from below to fix the identification terminal; Bresee DR21 8UW U82 8 inch Facial
Recognition Door Gate Terminal - gate type installation
1

Step 4: as shown in Fig. 3-4, loosen the screw on the upright support, adjust it to an appropriate angle and tighten it again; Bresee DR21 8UW U82
8 inch Facial Recognition Door Gate Terminal - gate type installation
23.2 wall mounted installationBresee DR21 8UW
U82 8 inch Facial Recognition Door Gate Terminal - wall mounted
installation

Step 1: as shown in Figure 3-5, fix the sheet metal on the back of the machine body with screws ①;
Step 2 : Mark four positioning points on the wall to confirm the installation position of the wall hanging support;
Step 3: as shown in Figure 3-5, align the four holes on the wall hanging bracket with the wall positioning point, lock four self-tapping screws ②, and fix the wall hanging bracket;
Step 4: as shown in Figure 3-5, fasten the access control terminal sheet metal to the wall hanging support through position ③;
Step 5: as shown in Figure 3-5, use screws ④ to fix the access control terminal and the wall hanging bracket;
Step 6: After installation, as shown in Figure 3-6; Bresee DR21 8UW U82
8 inch Facial Recognition Door Gate Terminal - wall mounted installation
1

wiring instructions

4.1 U82 schematic diagram of tail lineBresee DR21 8UW U82 8 inch Facial
Recognition Door Gate Terminal - wiring instructions

U82 interface description

Serial number| Interface name| Interface description| Pin color| Pin description
---|---|---|---|---
P1| RJ45
network port| Wired network port communication| /| RJ45 network port
P2| 12V power supply| 12V power input| /| DC_12V
P3| USB2.0| USB2.0 Interface| /| USB interface
P4| Relay output 1| Output 10 signal| WHITE| NO1
ORANGE| COM1
RED| NC1
P5| Relay output 2| Output 10 signal| GRAY| NO2
WHITE/ORANGE| COM2
WHITE/RED| NC2
P6| RS485| RS485 communication| BLACK| GND
RED| 5V
WHITE/PURPL E| RS485+
BROWN| RS485-
P7| WGOUT| Wigan signal output| BLACK| GND
YELLOW/GRAY| WG OUT D
OUTD0
WHITE/YELLOW| WG OUT D
OUT _D1
P8| ALN1_IN.
SEN_IN| Alarm signal input, door magnetic  signal input| BLACK| GND
PINK| ALM_IN1
YELLOW/BLACK| ALM_IN2
WHITE/GREEN| SEN_IN1

4.2 T82 schematic diagram of tail lineBresee DR21 8UW U82 8 inch Facial
Recognition Door Gate Terminal - wiring instructions 1 T82 interface description

Serial number| Interface name| Interface description| Pin color| Pin description
---|---|---|---|---
P1| RJ45
network port| Wired network port communication| /| RJ45 network port
P2| 12V power supply| 12V power input| /| DC 12V
P3| USB2.0| USB2.0 Interface| /| USB interface
P4| Relay output 1| Output 10 signal| WHITE| NO1
ORANGE| COM1
RED| NC1
P5| Relay output 2| Output 10 signal| GRAY| NO2
WHITE/ORANGE| COM2
WHITE/RED| NC2
P6| RS485| RS485| BLACK| GND
| | communication| RED| 5V
---|---|---|---|---
WHITE/PURPL E| RS485+
BROWN| RS485-
P7| WG OUT| Wigan signal output| BLACK| GND
YELLOW/GRAY| WG_OUT_D 0
WHITE/YELLOW| WG_OUT_D 1
P8| ALM _IN, SEN IN| Alarm signal input, door  magnetic signal input| BLACK| GND
PINK| ALM_IN1
YELLOW/BLACK| ALM_IN2
WHITE/GREEN| SEN_IN1

Equipment Use

5.1 starting equipment
After correct installation, connect the power adapter to the mains and the other end to the equipment power interface to start the equipment. When the display is powered on, it indicates that the device is started successfully.
5.2 entry
5.2.1 browser configuration
The following takes the windows 10 system and Google browser as examples.

  1. Please check the network connection between the client computer and the terminal before logging in to the web interface.
  2. It is recommended to use a 360-speed browser, chrome, Firefox, and other non-IE core browsers.
  3. For better display, please use the recommended resolution: 1600 × 900。

5.2.2 login web interface

  1. DHCP login (factory default DHCP);
    Enter the IP address in the upper left corner of the device display in the browser to enter the web login interface, as shown in Figure 5-1 and figure

Bresee DR21 8UW U82 8 inch Facial Recognition Door Gate Terminal - login web
interface

chart 5-2 IP access of input device

2. Static IP login:
Step 1: click the < setting > button on the device display screen interface; Enter the initial password < admin > to enter the network configuration interface.
Step 2: close DHCP and modify the static IP address, subnet mask and default gateway Save after, power off and restart the equipment.
Step 3: enter the modified IP in the browser to enter the web login interface.

  • Default static IP:192.168.0.13;
  • Subnet mask:255.255.255.0;

3.Log into the web interface:
After accessing the IP address of the device through the browser, enter the user name and password of the device, and click OK Click < login >, and you can enter the web management interface.
Default user name: admin; Default password: admin.
5.2.3 new personnel

  1. Select [personnel management – personnel information] interface and select the personnel library to add personnel;
  2. In the personnel list operation bar, click < add >;
  3. In the pop-up new personnel interface, refer to the following table to configure personnel information;
  4. Click < save > to finish adding personnel.
    5.3 recognition
    The tester can realize the recognition function by placing it directly in front of the recognition equipment.
    Note: detailed instructions for the use of the recognition terminal can be obtained by contacting our personnel.

6 EU DECLARATION OF CONFORMITY

Hereby, Bresee Technology Co., Ltd. declares that the radio equipment type DR21-8UW, DE21-8TW is in compliance with Directive 2014/53/EU. The full text of the EU  declaration of conformity Please see attachment DOC Letter

FCC Caution.

§ 15.19 Labeling requirements.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
§ 15.21 Information to the user.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
§ 15.105 Information to the user.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. This equipment complies with RF radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body.