Key function

Key-value Specification
PAIR press and hold button ,the remote enters pairing mode, backlight LED

flashes, When the pair succeeds, the backlight stops flashing then normally on.
HEAD UP| Press and hold button, the head actuator moves out, stop when released
HEAD DOWN| Press and hold button, the head actuator moves in, stop when released
---|---
FOOT UP| Press and hold button, foot actuator moves out, stop when released
FOODTOWN| Press and hold button, foot actuator moves in, stop when released
TILT-UP| Press and hold button, tilt actuator moves out, stop when released
TILT DOWN| Press and hold Dutton, tilt actuator moves in, stop when released
FLAT| Click the button, the bed goes flat
Lock| Press and hold the button for 5s until the backlight flashes, then the lock/unlock is complete.
ZG| Click button, the bed moves to zeroG position, press and hold zeroG button for 5s, until backlight flashes, the control set the current position as zeroG position
TV/PC| Click the button, the bed moves to TV/PC position, press and hold TV/PC button for 5s, until backlight flashes, the control set the current position as TV/PC position
UNDER-BED LIGHT| Click the button, the under bed light switch its on/off state; After the under bed light opens, if do not manually close, it will automatically turn off after 5 minutes;
MI| Click the button, the bed moves to M (position, press and hold MI button for 5s, until backlight flashes, the control set the current position as MI position
M2| Click the button, the bed moves to M2 position, press and hold M2button for 5s, until backlight flashes, the control set the current position as M2 position
FLASHLIGHT| Press and hold button, open flashlight, close when released
---|---
MASSAGE HEAD+| Click the button, head massage motor switch its intensity among 1-2-3-0-1
MASSAGE FOOT+| Click button, foot massage motor switch its intensity among 1-2-3-0-1
TIMER| If the massage motors do not work, the button is invalid, if the massage motors work, click the button to switch the massage time, when massage time switch to 0, turn off the massage;
MASSAGE HEAD-| Click the button, head massage motor switch its intensityamong3-2-1-0-3
MASSAGE FOOT—| Click button, foot massage motor switch its intensityamong3-2-1-0-3
MASSAGE TYPE| Click the button, to switch the massage mode of massage motors, massage mode switches among type0→types1→ type2→type3→type0; this button can only switch the massage mode, it can not open massage motors:

FCC Statement

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

FCC Radiation Exposure Statement:

The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

ISED RSS Warning/ISED RF Exposure Statement

ISED RSS Warning:
This device complies with Innovation, Science, and Economic Development Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. this device may not cause interference, and
  2. this device must accept any interference, including interference that may cause undesired operation of the device.

ISED RF exposure statement:
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. The device has been evaluated to meet general RF exposure requirements.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals