The 12CH DMX RELAY PACK can be controlled by DMX 512 console. Each output socket is controlled individually by one relay. It can be widely applied to entertainment halls, stages, social clubs, and indoor building decoration.

– LED digital display for DMX addressing and work mode setting
– universal DMX512 (1990) multiplexed digital control
– DMX and Stand-Alone operation modes
There are two modes of operation:
DMX: Either: 1, 2, 3, 6, or 12 channel.
Manual control mode.
Each mode can be selected by first pressing the MODE button followed by the UP / DOWN buttons and SET to confirm. Each of the modes is displayed below:

Control Panel Menu

DMX mode
You can control devices individually via the sliders on your DMX controller. Each of the values is listed below

CH01 :1 channel mode

CH No.

| DMX value|

Function

---|---|---
CH1| 000~010| CLOSE(No.1- 12 OUTPUT SOCKET)
011~255| OPEN(No.1-12 OUTPUT SOCKET)

CH02:2 channels mode

CH No.

| DMX value|

Function

---|---|---
CH1| 000~010| CLOSE(No.1-6 OUTPUT SOCKET)
011~255| OPEN(No.1-6 OUTPUT SOCKET)

CH2

| 000~010| CLOSE(No.7-12 OUTPUT SOCKET)
011~255| OPEN(No.7-12 OUTPUT SOCKET)

CH03:3 channels mode

CH No. DMX value Function
CH1 000~010 CLOSE(No.1-4 OUTPUT SOCKET)
011~255 OPEN(No.1-4 OUTPUT SOCKET)
CH2 000~010 CLOSE(No.5-8 OUTPUT SOCKET)
011~255 OPEN(No.5-8 OUTPUT SOCKET)
CH3 000~010 CLOSE(No.9-12 OUTPUT SOCKET)
011~255 OPEN(No.9-12 OUTPUT SOCKET)

CH06:6 channels mode

CH No.

| DMX value|

Function

---|---|---
CH1| 000~010| CLOSE(No.1-2 OUTPUT SOCKET)
011~255| OPEN(No.1-2 OUTPUT SOCKET)
CH2| 000~010| CLOSE(No.3-4 OUTPUT SOCKET)
011~255| OPEN(No.3-4 OUTPUT SOCKET)
CH3| 000~010| CLOSE(No.5-6 OUTPUT SOCKET)
011~255| OPEN(No.5-6 OUTPUT SOCKET)
CH4| 000~010| CLOSE(No.7-8 OUTPUT SOCKET)
011~255| OPEN(No.7-8 OUTPUT SOCKET)
CH5| 000~010| CLOSE(No.9-10 OUTPUT SOCKET)
011~255| OPEN(No.9-10 OUTPUT SOCKET)
CH6| 000~010| CLOSE(No.11-12 OUTPUT SOCKET)
011~255| OPEN(No.11-12 OUTPUT SOCKET)

CH12:12 channels mode

CH No. DMX value Function
CH1 000~010 CLOSE(No.1 OUTPUT SOCKET)
011~255 OPEN(No.1 OUTPUT SOCKET)
CH2 000~010 CLOSE(No.2 OUTPUT SOCKET)
011~255 OPEN(No.2 OUTPUT SOCKET)
CH3 000~010 CLOSE(No.3 OUTPUT SOCKET)
011~255 OPEN(No.3 OUTPUT SOCKET)
CH4 000~010 CLOSE(No.4 OUTPUT SOCKET)
011~255 OPEN(No.4 OUTPUT SOCKET)
CH5 000~010 CLOSE(No.5 OUTPUT SOCKET)
011~255 OPEN(No.5 OUTPUT SOCKET)
CH6 000~010 CLOSE(No.6 OUTPUT SOCKET)
011~255 OPEN(No.6 OUTPUT SOCKET)
CH7 000~010 CLOSE(No.7 OUTPUT SOCKET)
011~255 OPEN(No.7 OUTPUT SOCKET)
CH8 000~010 CLOSE(No.8 OUTPUT SOCKET)
011~255 OPEN(No.8 OUTPUT SOCKET)
CH9 000~010 CLOSE(No.9 OUTPUT SOCKET)
011~255 OPEN(No.9 OUTPUT SOCKET)
CH10 000~010 CLOSE(No.10 OUTPUT SOCKET)
011~255 OPEN(No.10 OUTPUT SOCKET)
CH11 000~010 CLOSE(No.11 OUTPUT SOCKET)
011~255 OPEN(No.11 OUTPUT SOCKET)
CH12 000~010 CLOSE(No.12 OUTPUT SOCKET)
011~255 OPEN(No.12 OUTPUT SOCKET)

Specifications

Power supply

|

230Vac, 50Hz

---|---
Maximum current input| 30A
Maximum current per channel| 10A
IEC outputs| 12
Dimensions| 440 x 205 x 88mm
Weight| 3.8kg

This product is classed as Electrical or Electronic equipment and should not be disposed of with other household or commercial waste at
the end of its useful life. The goods must be disposed of according to your local council guidelines.
Errors and omissions excepted.
Copyright© 2021 AVSL Group Ltd, Unit 2 Bridgewater Park,
Taylor Road, Trafford Park, Manchester. M41 7JQ.
www.avsl.com 
AVSL (Europe) Ltd, Unit 3D North Point House,
North Point Bus. Park, New Mallow Road, Cork, Ireland.
154.113UK User Manual

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals