PLANET IGS-6329 Industrial L3 Multi-Port Gigabit Managed Switch Installation Guide
- June 6, 2024
- PLANET
Table of Contents
Quick Installation Guide
Industrial L3 Multi-Port
Gigabit Managed Ethernet Switch
IGS-6329 DIN-rail Series
Package Contents
Thank you for purchasing PLANET 0 Industrial Managed Switch, IGS-6329 DIN-rail
series. The descriptions of these models are as follows: The descriptions of
these models are shown below:
IGS-6329-8UP2S2X Industrial 0 8-Port 10/100/1000T 802.3bt PoE + 2-Port
1G/2.5G SFP + 2-Port 10G SFP+ Managed Ethernet Switch
IGS-6329-8UP2S4X Industrial 0 8-Port 10/100/1000T 802.3bt PoE + 2-Port
1G/2.5G SFP + 4-Port 10G SFP+ Managed Ethernet Switch
`Industrial Managed Switch” mentioned in this Quick Installation Guide
refers to the above models.
Open the box of the Industrial Managed Switch and carefully unpack it. The
box should contain the following items:
Item | IGS-6325-8UP2S4X | IGS-6325-8UP2S2X |
---|---|---|
The Industrial Managed Switch | ■ | ■ |
DB9 to RJ45 Interface RS232 Console Cable | ■ | ■ |
Quick Installation Guide | ■ | ■ |
Wall Mounting Kit | ■ | ■ |
RJ45 Dust Cap | 9 | 9 |
SFP Dust Cap | 6 | 4 |
If any of these are missing or damaged, please contact your dealer immediately. If possible, retain the carton including the original packing materials to enable you to repack the product in case there is a need to return it to us for repair.
Requirements
The Industrial Managed Switch provides a local and remote login interface for management purposes. The following equipment is necessary for further management: Workstations running Windows 7/8/10/11, Windows 2012/2008, Mac OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP Protocols.
- Workstations are installed with Ethernet NIC (Network Interface Card).
- Serial Port Connection (Terminal) .
- The above Workstations come with COM Port (DB9) or USB-to-RS232 converter.
- Terminal emulator – The above Workstations have been installed with a terminal emulator , such as Tera Term, PuTTY, or Hyper Terminal included in Windows XP/2003.
- Serial cable — one end is attached to the RS232 serial port, while the other end is to the console port of the Industrial Managed Switch.
Ethernet Port Connection
Network cables — Use standard network (UTP) cables with RJ45 connectors.
The above PC is installed with a Web browser.
Note It is recommended to use Internet Explorer 11.0 or above to access
the Industrial Managed Switch.
If the Web interface of the Industrial Managed PoE+ Switch is not accessible,
please turn off the anti-virus software or firewall and then try it again.
3. Wiring the Power Inputs
The Upper Panel of the Industrial Managed Switch indicates a power socket and
consists of one green terminal block connector within 6 contacts. Please
follow the steps below to insert the power wire.
1. Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1,
or Contacts 5 and 6 for Power 2.
IGS-6329-Series: DC 48-54V
Figure 3-1: IGS-6329-Series Upper Panel
Note Dual power input is required for maximum PoE loading
Single power input: Maximum 240-watt PoE budget
Dual power input: Maximum 360-watt PoE budget
Caution: PWR1 and PWR2 must provide exactly the same DC voltage for power
load balance while operating with dual power input.
Tighten the wire-clamp screws for preventing the wires from loosening
Figure 3.2: The pin of 6-contact terminal block connector
Note 1. The wire gauge for the terminal block should be in the range of
12 to 24 AWG. 2. Please check the wire AWG Ampere specification before
connecting the PLANET Industrial Managed Switch.
3.1 Grounding the Device
Users MUST complete grounding wired with the device; otherwise, sudden
lightning could cause fatal damage to the device.
Terminal Setup
To configure the system, connect a serial cable to a COM port on a PC or
notebook computer and to R345 type serial (console) port of the Industrial
Managed Switch.
A terminal program is required to make the software connected to the
Industrial Managed Switch.
1. Run the terminal program on the OS.
2. When the following screen appears, make sure that the COM port should be
configured as:
- Baud: 115200
- Parity: None
- Data bits: 8
- Stop bits: 1
- Flow control: None
4.1 Logging on to the Console Once the terminal has been connected to the device, power on the Industrial Managed Switch and the terminal will display “running testing procedures”.
Note
The following console screen is based on the IGS-6329-8UP2S4X. The display of
the IGS-6329 series is the same as that of the IGS-6329-8UP2S4X.
Then, the following message asks to log in with the user name and password.
The factory default user name and password are shown as follows as the login
screen in Figure 4-1 appears
Username: admin
Password: admin ****
Figure 4-1: Console Login Screen
The user can now enter commands to manage the Industrial Managed Switch. For a
detailed description of the commands, please refer to the following chapters.
Note
1. For security reasons, please change and memorize the new password after
this first setup. 2. Only accept command in the lowercase letter under-console
interface.
4.2 Configuring IP Address via Console
The Industrial Managed Switch is shipped with the default IP address shown
below:
IP Address: 192.168.0.100 Subnet Mask: 255.255.255.0
To check the current IP address or modify a new IP address for the Switch,
please use the procedure as follows:
Display of the Current IP Address
1. At the “#” prompt, enter “show ip interface brief”.
2. The screen displays the current IP address shown in Figure 4-2.
Figure 4-2: IP Information Screen
Configuration of the IP Address
3. At the “#” prompt, enter the following command and press
IIGS-6329-Series# configure terminal
IGS-6329-Series (config)# Interface VLAN 1
IGS-6329-Series (config-if-VLAN)# 1p address 192.168.1.100 255.255.255.0
The previous command would apply the following settings for the Industrial
Managed Switch.
IP Address: 192.168.1.100
Subnet Mask: 255.255.255.0
Figure 4-3: Configuring IP Address Screen
4. Repeat step 1 to check if the IP address has changed.
4.3 Storing Current Switch Configuration
1. At the “St” prompt, enter the following command and press
# copy running-config startup-config
Figure 4-4: Saving Current Configuration Command Screen
If the IP is successfully configured, the Industrial Managed Switch will apply
the new IP address setting immediately. You can access the Web interface of
the Industrial Managed Switch through the new IP address.
If you are not familiar with the console command or the related parameter,
enter “help” anytime in the console to get the help description.
Starting Web Management
The following shows how to start up the Web Management of the Industrial
Managed Switch. Note the Industrial Managed Switch is configured through an
Ethernet connection. Please make sure the manager PC must be set to the same
IP subnet address.
For example, the default IP address of the Industrial Managed Switch is
192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a
number between 1 and 254, except 100), and the default subnet mask is
255.255.255.0. Figure 5-1: IP Management Diagram
Logging in to the Industrial Managed Switch
1. Use Internet Explorer 8.0 or above for Web browser and enter IP address
finny/y192./6Ft o.100 (the factory-default IP address) to access the Web
interface.
2. When the following dialog box appears, please enter the default user name
“admin” and password “admin” (or the password you have changed before) as
shown in Figure 5-2.
Default IP Address: 192.168.0.100
Default Username: admin
Default Password: admin Figure 5-2: Login Screen
3. After entering the password, the main screen appears as shown in Figure
5-3.
Figure 5-3: Web Main Screen of Industrial Managed Switch
The Switch menu on the top of the Web page lets you access all the commands
and statistics the Industrial Managed Switch provides. The Switch Menu always
contains one or more buttons, such as “System”, “Switching”, “Routing”,
“QoS”, “Security”, “PoE”, “Ring”, “ONVIF” and “Maintenance”.
Figure 5-4:Switch Menu
Figure 5-5: Example of Switch Sub-menu
Now, you can use the Web management interface to continue the Switch
management. Please refer to the user manual for more.
Note If you are not familiar with Switch functions or the related
parameter, press “Help Icon” anytime on the Web page to get the help
description.
5.2 Saving Configuration via Web
To save all applied changes and set the current configuration as a startup
configuration, the startup-configuration file will be loaded automatically
across a system reboot.
1. Click the Save icon on the top Switch Menu bar.
2. Press the “Save Configuration” button.
****3. Or the other way to save the setting is to Click Maintenance, Save
Startup Config.
6. Recovering Back to Default Configuration
The IP address has been changed or admin password has been forgotten —
To reset the IP address to the default IP address “192.168.0.100” and the user
password to factory default mode (default password is admin), press the
hardware-based reset button on the front panel for about 5″..10 seconds. After
the device is rebooted, you can log in the management Web interface within the
same subnet of 192.168.O.xx and default password. Be noted that all the
previous setups will be disappeared after the factory default reset is made.
Figure 6-1: IGS-6329-8UP2S2X/IGS-6329-8UP2S4X Reset Button
Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ
resource on the PLANET website first to check if it could solve your issue. If
you need more support information, please contact the PLANET switch support
team.
PLANET online FAQs: httn://www.planet and rwhanislinnort/fari Switch support
team mail address: support.aolanet.com.tw
IGS-6329-DIN-tail Series User’s Manual:
https://www.planet.com.tw/en/support/downloads?&method=keyword&keyword=IGS-6329&view=3#list
(Please select your switch model name from the Product Model drop-down menu)
Copyright C PLANET Technology Corp. 2021. Contents are subject to revision
without prior notice. PLANET is a registered trademark of PLANET Technology
Corp. All other trademarks belong to their respective owners.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>