Software s Power Supply PC Monitor Software Instructions
- June 4, 2024
- Software s
Table of Contents
Software s Power Supply PC Monitor Software
Software Instruction
Install Driver
- Decompress software package “Power Supply PC Monitor V X.X.X” to the following files.
- Select the serial chip driver, as shown below:
- Double-click or right-click to decompress the serial port Chip Driver package and install the CH340 driver:
- Click Install, wait for the installation to complete, click OK, as shown below:
- Go back to the computer and click device Manager to check the COM number and driver, as shown below :
Software Operation
Double-click the right mouse button to open the “exe” file, save the other filesThe initialization screen is displayed, as shown in the following figure.
How to connect
- Click “comm Setting” from left-top Menu bar, the serial port parameter setting screen is displayed.
- Set serial port parameters to set a port number, click the drop-down list, and select a COM number corresponding to the COM number of “USB-SERIAL CH340”. Other parameters are the default values.
- Click “Open” to complete the control connection of the upper computer.
Interface Guide
Channel Status Area
Parameter setting: Enter the required parameters in the parameter editing box and press Enter to complete the parameter setting.
Voltage/Current waveform Area
When the channel is open, the Voltage/Current curve of the channel can be observed in the waveform area.
Coordinate
Click the “ Coordinate ” setting in the voltage/Current waveform display
area to jump out of the setting interface and select the adaptive mode or
manually enter the numerical mode.
Adaption mode
Click “ ” next to electric pressure shaft adaptive and current adaptive, and
the state is “ “. Click “OK” to realize the adaptive mode.
Manually enter a numerical mode
Enter the desired coordinates and click” OK” to confirm the input.
List waveform editing Area
- Click in the upper left corner or directly click “edit” in the List waveform editing area. Input the required voltage, current, time, and Y/N after the serial number in the table (unchangeable) (when set to Y, the data is normally output; when set to N, the data is not output). The number of data groups can be set to 1-100;
- Parameter setting: Enter the required parameters in the parameter editing box and press “Enter” to complete the parameter setting.
- Set the start group number, end group number, and period for data output in sequence. Click “Start” to output data in sequence.
- Click “Stop” to stop data output.
Quick Set Area
We can set 8 groups of common values (M1-M8) by ourselves, which is convenient for subsequent direct calls.
Set the parameter
Let’s take setting the M1 parameter as an example:
Click after M1 to make it the selected state . In U/I/OVP/OCP, input the
required voltage/current/output overvoltage/output overcurrent values, and so
on, up to 8 groups of values can be input.
Call the numerical
Let’s take setting the M1 parameter as an example:
Click after M1 to make it the selected state , Click the “Call” in the upper right corner of the quick setting area to quickly deliver the four parameters U/I/OVP/OCP to the power supply.