- Alarm System Operation
- How to Set the System
- How to Unset the System
- How to Part Set the System
- How to Silence an Alarm and Reset the System
- How to Omit Zones
- How to Quick Set the System
- Single Key Setting
- How to Set Up Chime Mode
- Changing Codes Using User 1
- Changing Codes Using User 2
- How to Delete User Code 2
- To delete user code 2 using user code 2
- Duress Code
- How to View the Event Log
- How to Test Your Alarm system
- How to do a Walk Test
- How to Set up the Time and Date
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Accenta/Optima
User Guide
Servicing Organisation (Installer) name:…………………………
Telephone Number:……………………..
Date of Installation:…………………………
Account Number:………………………….
Introduction
This User Guide tells you how to operate your intruder alarm system. To
simplify this User Guide we have assumed that the alarm system has been
installed by a professional intruder alarm system installer (the installer),
and that the system is operated in a “typical” way.
Aspects of your system that are not “typical” will be described by your
installer.
NOTE: If you have any questions about your intruder alarm system, then consult
your installer, see contact details at the front of this User Guide.
Codes
To operate the alarm system you will need to use a code. A code is 4 digits
long, and can be any number from 0000 to 9999. By default user code 1 is
[0][1][2][3] but you should change this as soon as possible.
Alarm System Operation
This booklet describes three versions of the alarm system. The Optima version
has the keypad and indicators on the main control panel. The Accenta version
has the keypad and indicators on a small remote LCD or LED keypad. You operate
the alarm system by pressing buttons on the keypad and viewing the indicators.
Both alarm systems work the same way. Both Accenta and Optima systems can be
fitted with an optional remote keypad.
Personal Attack
If the installer has programmed a personal attack on the keypads and if you
are under threat, or are being attacked, you can activate the alarm by
pressing the 4 and 9 keys at the same time on any LED keypad. You can also
press the two keys marked PA on the remote LCD keypad. The alarm system will
produce a loud alarm sound, and the external siren will be turned on.
Fire Zones
Zones 7 and 8 on your alarm system may have a Fire or Smoke detector connected
to it. In the event of a fire the alarm system will produce a distinctive two-
tone fire alarm sound, and the outside siren will pulse 2 seconds on, 2
seconds off.
You should leave the premises immediately, and only re-enter when it is safe
to do so.
The alarm can be silenced by entering your code.
Power Indicator
The Power indicator on the control panel or keypad will light whenever the
mains power supply is present. If mains power fails then the Power indicator
will go out, but the system will run from its backup battery for several
hours. If the Power indicator goes out when mains power is present then a
fault may have developed on your system and you should contact your installer.
Signaling Device
Your alarm system may have been fitted with a signaling device. This device
uses the telephone line to send an alarm message to an Alarm Receiving Centre
in the event of an alarm. The operator at the ARC may request the police to
attend your premises.
How to Set the System
When you leave your premises you will need to set (or turn on) the intruder
alarm system. Before setting the system you should ensure that the premises
have been completely vacated and that all doors and windows are closed. Ensure
that pets do not have access to the protected areas as they can cause a false
alarm.
NOTE: The Accenta Remote LED keypad is not shown. It will have the same
indications as the Optima compact panel with the built-in keypad.
NOTE: There will be no exit beeps if Silent Timed exit mode was programmed.
LCD Keypad: the Day LED should be on. The screen shows the day mode:
LED Keypad: the Day LED should be on.
NOTE: You should wait until you hear that the exit beep has stopped before
assuming that the system has set.
LCD Keypad:
- Enter your 4-digit code (0123 default) and check that the system is clear.
- The exit tone begins to sound and the display shows program 1 in process of setting.
- Leave the premises by the agreed exit route.
- The exit tone becomes rapid during the last 10 seconds and then stops when the system sets. The Day LED goes off and SYSTEM SET appears on the screen
- After 30 seconds the set mode display appears.
LED Keypad:
- The system is unset. The Power and Day LED’s are on.
- Enter your 4-digit code (0123 default) and check that the system is clear (no zone LED’s on).
- The exit tone begins to sound to indicate that the system is in the process of setting.
- Leave the premises by the agreed exit route.
- 4The exit tone becomes rapid during the last 10 seconds and then stops when the system sets. The Day LED goes off.
How to Unset the System
When you enter your premises you will need to unset (turn off) the system.
LCD Keypad:
- Enter the premises by the agreed entry route. The system produces an entry tone. The Power LED is on and the Day LED is off indicating that the system is set.
- Enter your 4-digit code (0123 default).
- The system unsets with a double beep. The Day LED comes on indicating that the system is unset.
- After 30 seconds the Day mode display appears.
LED Keypad:
- Enter the premises by the agreed entry route. The system produces an entry tone. The Power LED is on and the Day LED is off indicating that the system is set.
- Enter your 4-digit code (0123 default).
- The system unsets with a double beep. The Day LED comes on indicating that the system is unset.
If any Zone, TA (Tamper), or PA (Attack) LED’s come on then an alarm has
occurred, and an intrusion may have taken place. Seek assistance before
investigating further as intruders may still be on the premises. Then reset
the system.
When you enter your premises you will have a short period of time, usually 30
seconds, to enter your code. If you fail to do this the system will go into
alarm. Enter your code to stop the alarm.
How to Part Set the System
If your installer has programmed your system for the part set operation you
will be able to set some zones of the system while others remain unset. The
part set operation is often used at night time, and it will permit you to
freely walk around the bedrooms while the living area and outside doors are
protected. Your system may have 2 part-set programs called Program 2 and
Program 3.
Before part-setting the system you should ensure that all doors and windows
are closed. Ensure that pets do not have access to the protected areas. Your
installer may have instructed you to use a different keypad to the one
normally used to set the system.
LCD Keypad:
- The Day LED should be on. The screen shows the Day mode:
- Enter your code [0][1][2][3]. The exit beep starts.
- Press the [PROG] key. The exit tone stops.
- Select part-set program [2] or [3]. The system will set after a short time. The Day LED goes out.
NOTE: There will be no exit beeps if Silent Timed exit mode was programmed.
LED Keypad :
The Day LED should be on.
-
Enter your code [0][1][2][3]. The exit beep starts.
-
Press the [PROG] key. The exit tone stops and the zone
LED’s 1 to 3 come on. -
Select part-set program [2] or [3]. The system will set after a short time. The Day LED goes out.
NOTE: There will be no exit beeps if Silent Timed exit mode was programmed.
How to Silence an Alarm and Reset the System
If your system goes into alarm then be aware that intruders may be in the
premises. Seek assistance before investigating the cause of the alarm.
LCD Keypad:
- Enter your code [0][1][2][3]. The alarm will stop.
- The screen alternates showing what caused the alarm and prompting for user reset
When two or more alarms have occurred, the first alarm will have an F below the zone number, Tamper or PA. Subsequent alarms will have a 1 indicating where the alarm has taken place.
- Press [RESET]. The system resets and goes into day mode if there are no open Tampers, PA or Fire zones to cause a fault lockout.
The system can be reset by the user only if the installer has programmed it to do so. If the message Engineer Restore Required appears on the screen then the user will have to contact the installer.
- After 30 seconds the set mode display appears.
LED Keypad:
- Enter your code [0][1][2][3].
The alarm will stop, and the Zone, Tamper (TA) or Attack (PA) LED’s will come on to show the cause of the alarm.
NOTE: When 2 or more LEDs are on, the flashing indicator shows the first alarm, and the steady indicators show the second and subsequent alarms.
- Press [RESET].
- If the Zone, Tamper (TA), or Attack (PA) LED’s go out and the Day LED comes on then the system has been reset.
If any of the LEDs continue to flash then the system has been programmed to be reset by the installer. In this case, you must call the installer to reset the system. If all LED lights are steady (not flashing), and the keypad stops working, then the system has entered a fault lockout. You must call the installer to rectify this fault.
How to Omit Zones
If you cannot set the alarm system because a detector is faulty and in
constant alarm you may need to omit its zone from the alarm system. A zone
that has been omitted cannot cause an alarm. Omitted zones will be restored
after the system is unset.
Before a zone can be omitted it has to be enabled by the installer as a Used
Zone and as an Omit Allow zone.
LCD Keypad:
- Enter your [4-digit code] to start the exit procedure (for more information see How to Set the System).
- Press [OMIT] and the exit beep tone will stop, and the first used zone that can be omitted will appear on the display.
- Press the zone [number] or [up arrow] to be omitted. The display will now show the zone as omitted. If a flat reject tone is heard, then the zone cannot be omitted.
- Press [SET] or allow the system to continue to set.
NOTE: Zn = Zone number
LED Keypad:
-
Enter your [4-digit code] to start the exit procedure (for more information see How to Set the System).
-
Press [OMIT] and the exit beep tone will stop, and all
LEDs for used zones that can be omitted will come on. -
Press the zone [number] to be omitted. The LED will now flash to show the zone as omitted. If a flat reject tone is heard, then the zone cannot be omitted.
-
Press [SET] or allow the system to set.
How to Quick Set the System
When you set the system you will usually have about 30 seconds to exit the premises. This also means that you need to wait 30 seconds for the system to set. You can reduce this time to just five seconds by carrying out a Quick Set.
- Enter your [4-digit code] to start the exit procedure. The exit beep tone will start. (For more information see How to Set the System).
- Press [SET] to Quick Set the system and the exit beep tone will change to a more rapid tone. The system will set in five seconds, and the exit tone will stop.
Single Key Setting
If enabled by the engineer, the setting process can be started by pressing Set, rather than entering a user code.
How to Set Up Chime Mode
Chime is a low-security facility for use when the system is unset. It is particularly useful in a shop to warn of customers’ presence, or in a house to warn when a back door has been opened. When a Chime zone detects movement the system will produce a brief two-tone sound, and the Zone LED will come on. To set any zone to Chime.
LCD Keypad:
- The system should be in Day mode (System Unset).
- Press [CHIME]. The screen will show the first zone that is already set up for Chime (possibly none).
- Press the zone [number] to toggle it in and out of chime.
- When you have finished using the Chime mode press [RESET] or wait a few seconds for the display screen to show Day mode.
NOTE : Zn = Zone number
LED Keypad:
- The system should be in Day mode (System Unset).
- Press [CHIME]. The zone LED’s will come on to show those zones that are already set up for Chime (possibly none).
- Press the zone [number] to toggle it in and out of chime.
- When you have finished using the Chime mode press [RESET] or wait a few seconds. The zone LED goes off.
Changing Codes Using User 1
You should change your code regularly to prevent potential intruders from
knowing your code. All codes are 4-digits. The factory set code is
[0][1][2][3]. User code 1 can only be changed by user 1.
To change user code:
LCD Keypad:
-
Press [PROG] and then enter your code [0][1][2][3]. The
Day LED goes off to indicate that you are in Programming
mode. The first menu Walk Test appears on the screen. -
Press the [8] button on the keypad to enter User Set-Up.
-
Press the [1] or [2] button on the keypad to edit the required user.
-
Enter the new [4-digit code]. If the code is accepted the system will produce a double beep. If it is rejected the code may already be in use and the system will produce a flat tone. You must choose a different 4-digit code.
-
Upon the last keypress, the code is saved.
-
Press [RESET] twice to exit Programming mode. The Day LED will come on with the screen in Day mode.
LED Keypad:
-
Press [PROG] and then enter your code [0][1][2][3]. The Tamper (TA) LED comes on and the Day LED goes off to indicate that you are in Programming mode.
-
Press the [8] button on the keypad. LED’s 1 and 2 are on to indicate that you have two options, user 1 and user 2.
-
Press the [1] or [2] button on the keypad to edit the required user. LED’s 1-4 are on.
-
Enter the new [4-digit code]. If the code is accepted the system will produce a double beep. If it is rejected the code may already be in use and the system will produce a flat tone.
You must choose a different 4-digit code. -
Upon the last keypress, the code is saved. LED’s 1-4 are off.
-
Press [RESET] twice to exit Programming mode. The Day LED comes on and the Tamper (TA) goes off.
Changing Codes Using User 2
Your alarm system can have a second user code. You may find it useful to set up user code 2 for use by a neighbor for use when you are on holiday. User code 2 operates like user code 1, but it cannot be used to change or delete user code 1.
To change user code 2:
LCD Keypad:
-
Press [PROG] and then enter user 2 [four-digit code]. The Day LED goes off to indicate that you are in Programming mode. The first menu Walk Test appears on the screen.
-
Press [8] to edit user 2.
Enter the new [4-digit code]. If the code is accepted the system will produce a double beep. If it is rejected the code may already be in use and the system will produce a flat tone. You must choose a different 4-digit code. -
Upon the last keypress, the code is saved.
-
Press [RESET] twice to exit Programming mode. The Day LED will come on with the screen in Day mode.
LED Keypad:
- Press [PROG] and then enter user 2 [four-digit code]. The Tamper (TA) LED comes on and the Day LED goes off to indicate that you are in Programming mode.
- Press the [8] to edit user 2. LED’s 1-4 are on.
- Enter the new [4-digit code]. If the code is accepted the system will produce a double beep. If it is rejected the code may already be in use and the system will produce a flat tone. You must choose a different 4-digit code.
- Upon the last keypress, the code is saved. LED’s 1-4 are off.
- Press [RESET] twice to exit Programming mode. The Day LED comes on and the Tamper (TA) goes off.
How to Delete User Code 2
You can delete the second code to prevent it from being used. User 1 or user 2 can delete user code 2.
To delete user code 2 using user code 1
LCD Keypad:
- Press [PROG] and then enter your code [0][1][2][3]. The Day LED goes off to indicate that you are in Programming mode. The first menu Walk Test appears on the screen.
- Press the [8] button on the keypad to enter User Set-Up.
- Press [2] to edit user code 2.
- Press [OMIT] to delete user code 2.
- The message Code Deleted is displayed on the screen.
- Press [RESET] twice to exit Programming mode. The Day LED will come on with the screen in Day mode.
LED Keypad:
- Press [PROG] and then enter your code [0][1][2][3]. The Day LED goes off to indicate that you are in Programming mode.
- Press the [8] button on the keypad to enter User SetUp. LED’s 1 and 2 are on.
- Press [2] to edit user code 2. LED’s 1-4 are on.
- Press [OMIT] to delete user code 2.
- User code 2 is deleted. LED’s 1-4 are off.
- Press [RESET] twice to exit Programming mode. The Day LED comes on and the Tamper (TA) goes off.
To delete user code 2 using user code 2
LCD Keypad:
-
Press [PROG] and then enter the user 2 [4-digit code] .
The Day LED goes off to indicate that you are in Programming mode. The first menu Walk Test appears on the screen. -
Press the [8] button on the keypad to edit user code 2.
-
Press [OMIT] to delete user code 2.
-
The message Code Deleted is displayed on the screen.
-
Press [RESET] twice to exit Programming mode. The Day LED will come on with the screen in Day mode.
LED Keypad:
-
Press [PROG] and then enter the user 2 [4-digit code].
The Day LED goes off to indicate that you are in Programming mode. -
Press the [8] button on the keypad to edit user code 2. LEDs 1-4 are on.
-
Press [OMIT] to delete user code 2.
-
User code 2 is deleted. LEDs 1-4 are off.
-
Press [RESET] twice to exit Programming mode. The Day LED comes on and the Tamper (TA) goes off.
Duress Code
Your alarm system can have a dress code. The Duress code is used in a hold-up
situation where there is pressure to set or unset the system. The Duress code
operates like your normal code but in addition, it will silently send a signal
to the Alarm Receiving Centre. The operator at the ARC may request the Police
to attend your premises.
The dress code can only be set up, edited, and deleted by the installer while
in Engineer program mode.
NOTE: The Duress code facility is not applicable to the Optima compact
system.
How to View the Event Log
1 = LCD Keypad:
The event log gives a display of all the events that have taken place. The
events are arranged by date and time.
Up to 250 events can be stored in the memory. When the log reaches 250 events
and another event takes place, the oldest event drops out.
To view the event log:
-
Press [PROG] and then enter your code [0][1][2][3]. The Day LED goes off to indicate that you are in Programming mode. The first menu Walk Test appears on the screen.
-
Press [CHIME].
-
Choose [1] for Event Log in LCD screen.
-
The last event (250) appears on LCD screen.
To go forward through the event log in sequence, press [OMIT].
To go back through the event log in sequence, press the [up arrow]. -
Press [RESET] twice to leave the menu. To go to a specific event:
-
Press the [PROG] button.
-
Key in Event Number you want to see (eg 150).
-
Press the [SET] button. The event appears on the LCD screen.
-
Press [SET] again to see further details of the event.
-
Press [RESET] twice to leave the menu option.
2 = LED Keypad:
The LED keypad is limited to show the last eight set periods with the eighth
being the oldest. Zone, Attack (PA), and Tamper (TA) LED’s will be on to show
zone in alarm. Flashing LED indicates the first zone in the alarm. The day
indicates the status of the panel at the time of the alarm.
- Press [PROG] and then enter your code [0][1][2][3]. The Day LED goes off and the Tamper (TA) LED comes on to indicate that you are in Programming mode.
- Press [CHIME] to enter into the Event Log menu. LED’s 1 and 2 are on.
- Press [2] for LED keypad. The first zone to activate is indicated by a flashing LED.
- Press [1 to 8] for the desired event or [CHIME] to go through events in sequence.
- Press [RESET] twice to leave the menu.
How to Test Your Alarm system
You should check that your alarm system still works correctly by periodically
carrying out the alarm system tests described here.
How to Test the Bell, Strobe and Internal Sounder
This function tests the alarm function of the Bell, Strobe or Internal
Sounder. Pressing the appropriate button [1-3] toggles the function ON or OFF.
Using the [up arrow] also selects the appropriate alarm function.
Pressing the [0] button turns all alarm outputs to OFF.
Pressing the [SET] button toggles the selected alarm output.
Pressing the [RESET] button turns off all outputs and leaves the function.
The outputs are:
1 = Bell, 2 = Strobe, 3 = Sounder
NOTE: To test the Low volume sounder enable option 3 only. To test for a high
volume sounder enable both options 2 and 3 together.
LCD Keypad:
-
Press [PROG] and then enter your code [0][1][2][3]. The
Day LED goes off to indicate that you are in Programming mode. The first menu Walk Test appears on the screen. -
Press [up arrow] for menu Alarm Test.
-
Press [1] or [SET] to enter into the first function ON or OFF.
-
Press the [up arrow] or number [2] or [3] for the other functions.
-
Press [RESET] to leave the menu.
LED keypad
- Press [PROG] and then enter your code [0][1][2][3]. The Day LED goes off and the Tamper (TA) LED comes on Press [1] for menu Alarm Test.
- Press [1] or [SET] to toggle the first function ON or OFF.
- Press numbers [2] and [3] for the other functions.
- Press [RESET] twice to exit Programming mode. The Day LED comes on and the Tamper (TA) LED goes off.
How to do a Walk Test
Walk around your property, and in turn cause each detector to go into alarm.
Also, open and close all door and windows that are protected by the system.
For each detector (including door or window sensor) that is activated the
system will produce a series of beeps, and the associated zone will be
indicated on the keypad.
NOTE: Do not test any Personal Attack, Fire or Tamper buttons during the Walk
Test since these are still active and will cause a full alarm.
If any of the tests fail, or you are unsure of the correct procedure, contact
your installer
LCD Keypad:
- Press [PROG] and then enter your code [0][1][2][3]. The Day LED goes off to indicate that you are in Programming mode. The first menu Walk Test appears on the screen.
- Press [SET] or [0]. Zones 1-8 have a zero (0) below each number.
- When a zone is successfully tested, number 1 replaces the 0. Zones are added to the list as each one is activated.
- Press [RESET] to leave the menu or [SET] to restart the Walk Test.
LED keypad
- Press [PROG] and then enter your code [0][1][2][3]. The Day LED goes off and the Tamper (TA) LED comes on to indicate that you are in Programming mode, Walk Test
- Press [SET] or [0]. Zones 1-8 are off.
- When a zone is successfully tested, the LED is on. Zones are added to list as each one is activated.
- Press [RESET] to leave the menu or [SET] to restart the Walk Test.
How to Set up the Time and Date
LCD Keypad:
-
Press [PROG] and then enter your code [0][1][2][3]. The Day LED goes off to indicate that you are in Programming mode. The first menu Walk Test appears on the screen.
-
Press [4] and the Time and Date Screen appears.
-
The Time can be modified in hours, minutes and seconds in the format HH:MM:SS. The number keys on the keypad 0-9 are used for this function. As each digit is modified the cursor moves to the next one. When the time is correct press the [SET] button to accept the change and move to the next screen or
-
To cancel the change press the [RESET] button twice.
-
The Date can be changed in day , month, year format DD-MM-YY.
The number keys on the keypad 0-9 are used for this function. As each digit is modified the cursor moves to the next one. When the date is correct press the [SET] button to accept the change or -
To cancel the change press the [RESET] button twice.
LED Keypad:
If required, the time and date can be entered as per the procedure for the LCD
keypad. However, no information will be indicated on the LED keypad. The only
indication on the LED keypad that you are in menu 4 Set up Time and Date is
that LEDs 1 to 6 on the LED Keypad will be ON.
External Siren Time:………………….
Siren delay:……………………………
Area Protected | Zone Name | Program 1 | Program 2 | Program 3 | |
---|---|---|---|---|---|
Zone 1 | |||||
Zone 2 | |||||
Zone 3 | |||||
Zone 4 | |||||
Zone 5 | |||||
Zone 6 | |||||
Zone 7 | |||||
Zone 8 |
T = Timed (Entry/Exit Zone)
TI = Timed Inhibited (Access zone to keypad)
I = Immediate
The panels conform to the requirements of the European EMC and Low Voltage directives and carry the CE mark
IU1-0040 Rev 1.0