Vantron IQ Hubv1.1 User Manual
- June 6, 2024
- Vantron
Table of Contents
Vantron IQ Hub v1.1
Foreword
Copyright Notice
While all information contained herein have been carefully checked to assure
its accuracy in technical details and printing, Vantron assumes no
responsibility resulting from any error or features of this manual, or from
improper uses of this manual or the software. Please contact our technical
department for relevant operation solutions if there is any problem that
cannot be solved according to this manual.
Vantron reserves all rights of this manual, including the right to change the
content, form, product features, and specifications contained herein at any
time without prior notice. The latest version of this manual is at
www.vantrontech.com.cn. Please contact
Vantron for further information:
Vantron Technology (Vantron) Email:
sales@vantrontech.com
The trademarks and registered trademarks in this manual are properties of
their respective owners. No part of this manual may be copied, reproduced,
translated or sold. No changes or other purposes are permitted without the
prior written consent of Vantron.
Vantron reserves the right of all publicly-released copies of this manual.
Notes
Applicable notes are listed in the following table:
Notice Type | Description |
---|---|
Notice | Important information and regulations |
Caution | Caution for latent damage to system or harm to personnel |
Statement
It is recommended to read and comply with this manual before operating IQ Hub which provides important guidance and helps decreasing the danger of injury, electric shock, fire, or any damage to the device.
Disclaimer
Vantron assumes no legal liability of accidents resulting from failure of conforming to the safety instructions.
Limitation of Liability / Non-Warranty
For direct or indirect damage to this device or other devices of Vantron caused by failure of conforming to this manual or the safety instructions on device label, Vantron assumes neither warranty nor legal liability even if the device is still under warranty.
Safety Instructions
Keep and comply with all operation instructions, warnings, and information. Pay attention to warnings on this device. Please read the following precautions so as to decrease the danger of injury, electric shock, fire, or any damage to the device.
Precautions
Pay attention to the product labels/safety instructions printed on silk
screens. Do not try repairing this product unless declared in this manual.
Keep away from heat source, such as heater, heat dissipater, or engine casing.
Do not insert other items into the slot (if any) of this device. Keep the
ventilation slot ventilated for cooling. System fault may arise if other items
are inserted into this device. Installation: ensure correct installation
according to instructions from the manufacturer with recommended installation
tools.
Ensure ventilation and smoothness according to relevant ventilation standard.
Safety Instructions for Power Cables and Accessories
Proper power source only.
Start only with power source that satisfies voltage label and the voltage
necessary according to this manual. Please contact technical support personnel
of Vantron for any uncertainty about the requirements of necessary power
source.
Power adapter Spec.
- Model:SW-120100
- INPUT:100-240V~50/60Hz 0.68A Max
- OUTPUT:DC 12.0V,1000mA
- MADE IN CHINA BY SURE-POWER
CAUTION
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED
BATTERIES ACCORDING TO THE INSTRUCTIONS MAKE SURE THE MECHINE IS POWER-OFF
BEFORE TAKE OUT BATTERIES
Place cables properly:
Do not place cables at any place with extrusion danger.
Cleaning Instructions
- Please power off before cleaning the device.
- Do not use spray detergent.
- Clean with a damp cloth.
- Do not try cleaning exposed electronic components unless with a dust collector.
Support for special fault: Power off and contact technical support personnel of Vantron in case of the following faults:
- The device is damaged.
- The temperature is excessively high.
- Fault is still not solved after the operation according to the manual.
Warnings, Cautions and Notes
- Warning! Warnings indicate conditions, which if not observed, can cause personal injury!
- Caution! Cautions are included to help you avoid damaging hardware or losing data. e.g. There is a danger of a new battery exploding if it is incorrectly installed. Do not attempt to recharge, force open, or heat the battery. Replace the battery only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer’s instructions.
- Note! Notes provide optional additional information.
Overview
Introduction
It is our commitment to provide our valued customers with the embedded devices
equipped with the state-of-the-art technology and the best product services.
Tablet enables the interaction between operators/users and applications,
connecting industrial control products such as wireless, transducer, battery
inside, storage, etc. Tablet adopts a display for displaying and input units
such as touch screen, keyboard, audio, kind of sensors etc. for writing
working parameters or inputting operation commands. As a digital device for
realizing information interaction between human and machine, Tablet is
composed of hardware and software. Based on its ample function interfaces and
powerful user operational interface, it is very suitable for control units
such as medical device, intelligent transportation, industrial field, etc.
Vantron’s VT-Tablet products are based on the most advanced ARM, Rockchip
processors and have low-power consumption and high integration. The products
are designed for applications such as industrials, medicals, and
transportations etc.
Ordering Information
CPA-G1A-UNA4
|
- TFT LCD
- 1024*600
- RK-3368H, Octa-core 1.5GHz
- Speaker and MIC
- 3.7V/2600mAh battery
- WIFI/BT
- Z-wave
- LTE-1
- SRF
---|---
Note: LTE modules cannot transmit with other wireless Function at the same time.
IQ Hub Hardware Instructions
Product Appearance
Front View
Back View
Specifications
CPU|
Processor
|
RK-3368H, ARM Octa-core
Cortex-A53, Quad Core CPU,1.5GHz
---|---|---
Memory|
RAM
|
2GB LPDDR3
Flash
|
16GB EMMC Flash
Display|
LCD
|
7″ TFT LCD
Resolution
|
1024*600 24bit Color
Display Colors
|
16.7M
Brightness
|
300cd/m2
View Angle
|
85U/85D, 85L/85R
Touch Screen
|
Cap-touch, multi-point
Supported Format|
Audio
|
MP3, 3GPP, WAV
Video
|
MP4, 3GPP
Picture
|
BMP, GIF, JPEG, PNG
Interface|
Wireless
|
- 1x W-iFi 802.11a/b/g/n/ac, 1x Bluetooth4.2
- 1x Z-wave
- 1x LTE
- 1x SRF
Internal Audio
| Internal Speaker, Buzzer
Internal MIC
RTC
|
Supported
10-85% RH (Non-Condensation), operating and storage
|
Supported
LED
|
Bi-color LED (Green and Red)
Software|
OS
|
Android 7.1+
Power|
Battery
|
3.7V, 2600mAh
DC Power Supply
|
12V,1.0A
Mechanical
|
Dimensions
|
196.4x155x25.6mm
Weight
|
0.65 Kg
Environment Condition|
Temperature
|
Operating Temperature:
0℃ ~ +40℃
Storage: -30℃ ~ +70℃
Humidity
|
10-85% RH (Non-Condensation), operating and storage
Interface Instructions
Front View
Back View
Dimension
- Whole Device Size: 196.4 x 155 x 25.6 mm
Power/Sleep/Wake Button
-
Power/Sleep/Wake Button
When you are not using the panel, you can turn off the display by press button -
Lock Tablet
Press the Power/Sleep/Wake button -
Unlock Tablet
Press the Power/Sleep/Wake button to wake from sleep, then drag the slider. -
Turn Tablet on From Power-off
Press and hold the Power/Sleep/Wake button until logo appears.
Never apply excessive pressure to a button, because this may cause unexpected
damage that is not covered under the warranty.
Tablet cannot be turned off by pressing the button
Interface Description
-
MIC
Internal MIC with outstanding sensitivity and high SNR makes it very suitable for recording while suppressing the environment noise. -
WIFI and BT
The tablet supports 802.11 a/b/g/n/ac Wi-Fi and BT 4.2. With a good performance internal antenna, both WIFI and BT can achieve better connectivity. -
Z-wave
The tablet has the function of Z-wave connectivity so we can use it in a lot of aspects such as access control, appliance control, AV control, building automation, energy management, lighting, security, and sensor networks for the “Internet of Things”. -
LTE
The tablet supports LTE Cat 1 function, delivering M2M-optmized speeds of 10Mbps downlink and 5Mbps uplink. And it features ultra-low power consumption which can extend the battery lifecycle without DC adapter plugging in. (Report reference FCC ID:XMR201909EG91NAX) -
Z-wave and SRF
RF Card, 908MHz – 916MHz,319.5MHz(Report reference FCC ID:2AAJXQS-SRF319) -
Speaker
The tablet has an internal 1 watt speaker -
Buzzer
There is a high SPL buzzer in tablet. It features high sound when turned on -
Gas Gauge
A gas gauge is used to monitor the capacity of the li-polymer battery so we can figure out the status of it precisely and immediately -
Front Camera
The tablet has the ability to take beautiful photo and record the high resolution video. -
RTC
The tablet has internal RTC so the system time can keep a long time if we didn’t turn it on.
Packing List
No | Part Description | Quantity | Remark |
---|---|---|---|
1 | CPA-G1A-UNA4 | 1 PCS |
- Power adapter
- Table stand
- Wall mount bracket
Software Instructions
Brief Introduction
IQ Hub has been pre-loaded with Android image, so that the system can run Android tool to flash the system image.
Safety Instruction
This section provides warnings that precede potentially dangerous procedures
throughout this manual. Instructions contained in the warnings must be
followed during all phases of operation, service, and repair of this
equipment. You should also employ all other safety precautions necessary for
the operation of the equipment in your operating environment. If you are not
sure about the precautions applicable to your operating environment, please
contact your company’s safety administrator. For basic information you may
also refer to the safety precautions per IEC704-1 listed below although
Vantron disclaims all responsibility for the accuracy of any statements
contained therein and its applicability for your specific environment. Failure
to comply with these precautions or with specific warnings elsewhere in this
manual could result in personal injury or damage to the equipment.
Vantron intends to provide all necessary information to install and handle the
IQ Hub in this manual. Because of the complexity of this product and its
various uses, we do not guarantee that the given information is complete. If
you need additional information, contact your Vantron representative.
The product has been designed to meet the standard industrial safety
requirements. It must not be used except in its specific area as specified in
product specification.
Only personnel trained by Vantron or persons qualified in electronics or
electrical engineering is authorized to install service or maintain the
product. The information given in this manual is meant to complete the
knowledge of a specialist and must not be used as replacement for qualified
personnel. Operating personnel must not remove equipment covers. Only factory
authorized service personnel or other qualified service personnel may remove
equipment covers for internal subassembly or component replacement or any
internal adjustment.
Do not install substitute parts or perform any unauthorized modification of
the equipment or the warranty may be voided. Contact your local Vantron
representative for service and repair to make sure that all safety features
are maintained.
Safety Precautions per IEC704-1
- Read these safety instructions carefully.
- Keep this User Manual for later reference.
- Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning.
- For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible.
- Keep this equipment away from humidity.
- Put this equipment on a reliable surface during installation. Dropping it or letting it fall may cause damage.
- The openings on the enclosure are for air convection. Protect the equipment from overheating. DO NOT COVER THE OPENINGS.
- Make sure the voltage of the power source is correct before connecting the equipment to the power outlet.
- Position the power cord so that people cannot step on it. Do not place anything over the power cord.
- All cautions and warnings on the equipment should be noted.
- If the equipment is not used for a long time, disconnect it from the power source to avoid damage by transient overvoltage.
- Never pour any liquid into an opening. This may cause fire or electrical shock.
- Never open the equipment. For safety reasons, the equipment should be opened only by qualified service personnel.
- If one of the following situations arises, get the equipment checked by service personnel:
- The power cord or plug is damaged.
- Liquid has penetrated into the equipment.
- The equipment has been exposed to moisture.
- The equipment does not work well, or you cannot get it to work according to the user’s manual.
- The equipment has been dropped and damaged.
- The equipment has obvious signs of breakage.
- DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW -20° C (-4° F) OR ABOVE 60° C (140° F). THIS COULD DAMAGE THE EQUIPMENT. THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT.
- CAUTION: DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER, DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER’S INSTRUCTIONS.
The sound pressure level at the operator’s position according to IEC 704-1:1982 is no more than 70 dB (A).
DISCLAIMER: This set of instructions is given according to IEC 704-1. Advantech disclaims all responsibility for the accuracy of any statements contained herein.
Safety Precautions – Static Electricity
Follow instructions below to protect yourself from harm and the products from damage:
- Being sure you are at an ESD workstation, or grounded with an ESD strap before opening the top cover or installing/removing any unit accessible from the outside. Doing so will discharge any static electricity that might have built up in your body.
- Don’t touch any components inside the system while the system is on.
- Disconnect power before making any configuration changes. The sudden rush of power as you connect a jumper or install a card may damage sensitive electronic components.
- When unpacking a static-sensitive component from its shipping carton, do not remove the component’s antistatic packing material until you are ready to install the component in the unit. 5. When transporting any electrical component, first place it in an antistatic container or packaging.
Waste Disposal
It is recommended to disassemble the device before abandoning it in conformity
with local regulations. Please ensure that the abandoned batteries are
disposed according to local regulations on waste disposal. Do not throw
batteries into fire (explosive) or put in common waste canister. Products or
product packages with the sign of “explosive” should not be disposed like
household waste but delivered to specialized electrical & electronic waste
recycling/disposal center. Proper disposal of this sort of waste helps
avoiding harm and adverse effect upon surroundings and people’s health. Please
contact local organizations or recycling/disposal center for more
recycling/disposal methods of related products.
Comply with the Following Safety Tips
Do not use in combustible and explosive environment.
Keep away from combustible and explosive environment for fear of danger.
Keep away from all energized circuits.
Operators should not remove enclosure from the device. Only the group or
person with factory certification is permitted to open the enclosure to adjust
and replace the structure and components of the device. Do not change
components unless the power cord is removed. In some cases, the device may
still have residual voltage even if the power cord is removed. Therefore, it
is a must to remove and fully discharge the device before contact so as to
avoid injury.
Unauthorized changes to this product or its components are prohibited.
In the aim of avoiding accidents as far as possible, it is not allowed to
replace the system or change components unless with permission and
certification. Please contact the technical department of Vantron or local
branches for help.
Pay attention to caution signs.
Caution signs in this manual remind of possible danger. Please comply with
relevant safety tips below each sign. Meanwhile, you should strictly conform
to all safety tips for operation environment.
Notice
Considering that reasonable efforts have been made to assure accuracy of this
manual, Vantron assumes no responsibility of possible missing contents and
information, errors in contents, citations, examples, and source programs.
Vantron reserves the right to make necessary changes to this manual without
prior notice. No part of this manual may be reprinted or publicly released in
forms of photocopy, tape, broadcast, e-document, etc.
US Office: Vantron Technology, Inc.
Address: 1292 Kifer Road #807, Sunnyvale, CA 94086
Tel: 510-304-7666
Email: sales@vantrontech.com
China Office: Chengdu Vantron Technology, Ltd.
Address: 6th floor, 1st building, No.9, 3rd WuKe East Street, WuHou
District, Chengdu, P.R. China 610045
Tel: 86-28-8512-3930/3931, 8515-7572/6320
Email: sales@vantrontech.com.cn
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
The device has been evaluated to meet general RF exposure requirement, the
device can be used in portable exposure condition without restriction.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy, and if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>