How to Download
Safety Instructions
The special attention should be paid when using the test and measurement instrument because the improper usage may cause electric shock and damage the equipment.
- Use proper measurement category (CAT), voltage, and amperage rated probes, test leads, and adapters for the measurement.
- Do not use or store the device around explosive gas, vapor, or under high temperature and humidity.
- When handling the test probes and crocodile clips, keep your fingers behind the physical guard.
- Examine the measuring test leads (if present) before use. Any element of which the insulation is deteriorated (even partially), replace them with proper functional test leads.
- Connect the common test lead before the live test lead and remove the live test lead before the common test lead.
- Before measuring current, make sure the instrument fuses available and disconnect the power supply to the circuit test
- Remove the batteries if the device is not used for an extended period of time, or if stored in temperatures above 45 °C. If the batteries are not removed, battery leakage can damage the device.
Contents
Specifications
|
R ange
| Resolution|
Accuracy
---|---|---|---
V~| 400 mV
4V/40V/400V
600V
| 0.1mV
1mV/10mV/0.1V
0.1V/1V
| ±(3.0%+3) ±(0.8%+3) ±(1.2%+3)
V| 400mV/4V/40V/400V
600V
| 0.1mV/1mV/10mV/0.1V
0.1V/1V
| ±(0.7%+2) ±(0.8%+2)
A~| 400μA/4000μA/40mA/400mA 10A| 0.1μA/1μA/10μA/0.1mA 1mA/10mA| ±(1.5%+5)
±(3.0%+7)
A| 400μA/4000μA/40mA/400mA 10A| 0.1μA/1μA/10μA/0.1mA 1mA/10mA| ±(1.2%+3)
±(2.0%+10)
R| 400Ω/4kΩ/40kΩ/400kΩ/4ΜΩ 40ΜΩ| 0.1Ω/1Ω/10Ω/0.1kΩ/1kΩ 0.01MΩ| ±(1.2%+2)
±(2.0%+5)
C| 4nF 40nF/400nF/4μF/40μF/200μF| 1pF 0.01nF/0.1nF/1nF/10nF/0.1μF| ±(4.0%+25)
±(4.0%+15)
Hz| 10Hz/100Hz/1kHz 10kHz/100kHz/200kHz >200kHz| 0.01Hz/0.01Hz/0.1Hz
1Hz/10Hz/0.1kHz 0.1kHz| ±(2.0%+5) ±(2.0%+5) Reference
Hz%| 5% ~ 95%| 0.1%| ±(2.0%+2)
A~
For Clamp Meter| 40A
400A
| 1A/1mV 1A/1mV| ±(1.0%+3) ±(1.0%+3)
A
For Clamp Meter| 40A
400A
| 1A/1mV 1A/1mV| ±(0.8%+3) ±(0.8%+3)
Battery Installation
How to Connect
Current Checkup
hFE
Mounting ON/OFF
ADP
Hz