MASTECH MS6100 Multi-Funciton Digital Counter User Guide

June 6, 2024
MASTECH

MASTECH MS6100 Multi-Funciton Digital Counter

MASTECH MS6100 Multi-Function Digital Counter

USA
MGL AMERICA, INC.
2810 Coliseum Centre Drive,
Ste. 100 Charlotte,
North Carolina 28217 USA
Tel: +1 833-533-5899
Email: cs.na@mgl-intl.com

UNITED KINGDOM
MGL GROUP U.K. LIMITED
14 Weller St, London, SE1 1QU, UK
Tel: +34 985-08-18-70
Email: cs.uk@mgl-intl.com
SKU Number: MS6100CBGLO

Quick Start Guide

MS6100

Multi-Function Digital Counter

MASTECH MS6100 Multi-Function Digital Counter 1

1 YEAR LIMITED WARRANTY

Special attention should be paid when using the test and measurement instrument because improper usage may cause electric shock and damage the equipment.

  • Use proper measurement category (CAT), voltage, and amperage-rated probes, test leads, and adapters for the measurement.
  • Do not use or store the device around explosive gas, vapor, or under high temperature and humidity.
  • When handling the test probes and crocodile clips, keep your fingers behind the physical guard.
  • Examine the measuring test leads (if present) before use. Any element of which the insulation deteriorates (even partially), replace them with proper functional test leads.
  • Connect the common test lead before the live test lead and remove the live test lead before the common test lead.
  • Before measuring current, make sure the instrument fuses available and disconnect the power supply to the circuit test
  • Remove the batteries if the device is not used for an extended period of time, or if stored in temperatures above 45 °C. If the batteries are not removed, battery leakage can damage the device.
Contents

Contents

Specifications

Range
Resolution
Accuracy

Frequency Measurements

Channel A 10MHz (10Hz~10MHz) 100MHz            1,10,100Hz selectable 10,100,1000Hz                ±1 count ±1×10-5x frequency (month) ±1 count ±5×10-6x frequency (minute)

Channel B                             1300MHz (100MHz~1300MHz) 1300MHz (100MHz~1300MHz)

Period Measurements

Channel A 0.1S~0.1μS                                                0.0μS 0.00μS                                  ±1 count ±1×10-5x frequency (month) ±1 count ±5×10-6x frequency (minute)
(10Hz~10MHz)                                          0.000μS selectable

Total Measurements

Channel A 10Hz~10MHz                                                1 count input

Period Measurements

Channel A MAX Input Voltage: 250V RMS / Impedance: 1MΩ less than 35pF

Channel B   MAX Input Voltage: 3V RMS / Impedance: 50Ω