Digilock Versa Hybrid Keypad/Smart Lock User Guide

June 6, 2024
Digilock

Digilock logo

Digilock Versa Hybrid Keypad/Smart Lock

Digilock Versa Hybrid Keypad Smart Lock

SHARED & ASSIGNED USE FUNCTIONALITY

Versa .ocks I/’. with a keypad interface are operated by a 4-7 digit User Code or by Mobile-ID. The Dig1Link network application simplifies lock management, and admin and manager credentials allow for management access.

LOCK ORIENTATION

Digilock Versa Hybrid Keypad Smart Lock -1

CREDENTIALS & ACCESSORIES

Digilock Versa Hybrid Keypad Smart Lock -2

  1. An unlimited amount of user credentials may be assigned to each lock, 1n assigned use functionahty.
  2. An unlimited amount of admin and manager credentials may be programmed to operate locks.

OPERATING INSTRUCTIONS – IN SHARED USE FUNCTIONALITY

In shared use functionality, the user enters any 4-7 digit pin code or uses their Mobile ID to lock, and the same pin code or Mobile-ID to unlock. Once unlocked, the lock is available for a different user.

Operate with a User Code

Digilock Versa Hybrid Keypad Smart Lock -3

Operate with a User Mobile ID Credential

Digilock Versa Hybrid Keypad Smart Lock -4

NOTE: Mobile ID app will show the current status of the lock.

Operate with an Admin or Manager Mobile ID Credential

Digilock Versa Hybrid Keypad Smart Lock -5

NOTE: Mobile ID app will show the current status of the lock.

Remote Unlock Using the Digilink App

Digilock Versa Hybrid Keypad Smart Lock -6

Unlock: Admin must locate the specific lock to be unlocked on the hardware list within the Digilink app then toggle the switch next to the lock name to the unlocked position.
Once toggled, the User must press[the button to unlock, then turn the knob to the unlocked position.

  • After 3 consecutive incorrect User Code entries, the keypad will be disabled for 1 minute (Sleep Mode).
  • If an Admin or Manager Credential is used to relock, the previous user credential will continue to operate the lock. ***Digilink app cannot be used to relock. Refer to operation instructions above to relock.

OPERATING INSTRUCTIONS – IN ASSIGNED USE FUNCTIONALITY

In assigned use functionality, users operate the lock with their assigned user credential (either a User Code or a Mobile ID credential).

Operate with an Assigned User Code

Digilock Versa Hybrid Keypad Smart Lock -7

Operate with an Assigned Mobile ID Credential

Digilock Versa Hybrid Keypad Smart Lock -9

NOTE: Mobile ID app will show the current status of the lock.

Operate with an Admin or Manager Mobile ID Credential

Digilock Versa Hybrid Keypad Smart Lock -9

NOTE: Mobile ID app will show the current status of the lock.

Remote Unlock Using the Digilink App

Digilock Versa Hybrid Keypad Smart Lock -10

  • After 3 consecutive incorrect User Code entries, the keypad will be disabled for 1 minute (Sleep Mode). tThe lock will remain in the locked position if the knob 1minte is not turned within approximately 6 seconds.

SUPPORT

Sleep Mode
After three consecutive incorrect User code entries to unlock, the lock will enter Sleep Mode for one minute and for an additional minute for each subsequent incorrect entry. The keypad is disabled while in Sleep Mode The lock may be unlocked remotely using the Digilink app while the lock is in “Sleep Mode.”

Low Battery Indicator
After locking or unlocking, the lock emits two sets of three beeps indicating that the batteries are low. Replace the batteries.

Does Not Unlock with the User Code or Mobile-ID
The 1ock does not recognize the User Code or Mobile-ID. For immediate access, operate with a valid Admin or Manager credential or remotely unlock with the Digilink app. If in assigned use functionality, follow the Registering Users and Assign Users instructions located in the Djgjljnk Initialization and Registration Guide to assign a user credential and assign user access to the lock{s).

Does Not Operate with an Admin in or Manager Credential
The lock does not recognize the Admin or Manager credential. Follow instructions to Assign Managers located in the Digilink Initialization and Registration Guide. For immediate access, operate with another valid Ad min or Manager credential or remotely unlock with the Digilink app.

Does Not Operate with the Digilink App
The lock may have not been added to the network. Follow the Lock Initialization instructions located in the Digilink Initialization and Registration Guide to add the lock to the network. If the lock is still non- functional with the Digilmk app after following those instructions, contact Digilock support for additional assistance.

No Audible Feedback when C is Pressed
The lock may be n ‘Sleep Mode” or the batteries may need to be replaced. For immediate access, operate using the Digilink app or a Power Jumper Key.

USING POWER JUMPER KEY

Digilock Versa Hybrid Keypad Smart Lock -11

  1. Insert the Power Jumper Key into the key slot.
    The LED will flash several times, a three-tone beep will be heard and the LED w• I turn off.
    IMPORTANT: Leave the key inserted until the lock is properly opened.

  2. Wh e the key is inserted press@) [a valid 4-7 digit code]or press [Q), then present a valid User, Admin, or Manager Mobile ID credentials, and press the locked icon within the Mobile ID app to unlock.
    NOTE: Mobile ID app will show the current status of the lock.

  3. Then turn the knob to the unlocked position.
    After gaining access to the lock change the batteries as soon as possible. The batteries are located in the adjacent battery pack.

BATTERY REPLACEMENT

Its not necessary to remove the 1ocK from, the door n case of battery fa ure, operates with a Power Jumper Ke)
CAUTION: Risk of explosion or leakage if the battery is replaced by an incorrect type, mixed with a different battery type, or inserted backward. Replace all batteries of a set at the same time. Be sure to insert batteries with correct polarities. Remove exhausted batteries from the product promptly and dispose of used batteries according to the battery manufacturer’s instructions.

Digilock Versa Hybrid Keypad Smart Lock -12

a Remove the screw and the battery cover
b Replace the four premium AA batteries.
c Replace battery cover and screw.

FCC’ Statment

This equipment ha, been tested and found to the comp!) with the limits for a Class B digital device, pursuant to part 15 of the f-CC Rule,. This limit, arc de, signed to provide RC.i.,enable protection against harmful interference ma residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and u, cd in accordance with the instruction,, mar cause harmful intcrfcrenu, to r,1dio communication,. However, there,no guarantee that interference will not occur in a particular installation. If this> equipment docs cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  1. Reorient or local.’ the receiving antenna.
  2. Increase the separation between the equipment and receiver
  3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  4. Consult the dealer or an experienced radio(!TVtechnician for help.

Caution: Any changes or modifications, to this device not explicitly) apprO\ed b)’ manufacturer would void your authority) to operate the equipment.
and, device compliance, “,th part 15 of the !·CC Ruic,. Operation b , subject to the form,ni: two conditions:

  1. This dc,1ce may not cause harmful interference, and
  2. this device mu,t accept am interference received, including interference that may cause undesired operation.
    The equipment come, with FCC radiation expo,ure limits ,et forth for an uncontrolled em·ironment. the equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals