Digilock D6PN-00-0 Cabinet Lock Installation Guide
- June 25, 2024
- Digilock
Table of Contents
Model: D6PN-00-0P, D6PN-00-0B, D6PN-10-0P, D6PN-10-0B
Product Name: Cabinet lock
1 Willowbrook Court Petaluma, CA 94954 United States +1 707-766-6000
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference
that may cause undesired operation.
2. Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a
class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates uses and can radiate radio frequence energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. if this equipmemt
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an autlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement, This equipment should be installed and operated with a minumum distance of 20 cm between the radiator and your body.
ISED Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
This device may not cause interference.
This device must accept any interference, including interference that may
cause undesired operation of the device.
This equipment should be installed and operated with a minimum distance of 20
cm between the radiator and your body
PRODUCT GUIDE
RFID and Mobile ID | Smart
LOCK OVERVIEW – PIVOT PRO
Pivot Pro locks with a touch-free RFID interface are operated by RFID credential or by Mobile ID. The DigiLink® network application simplifies lock management, and admin and manager credentials allow for management access.
Front Side View
-
Hook Catch Receiver
-
LED Indication
Occupied
Available -
Reader Area
-
Interior LED
Back Side View
- Hook Latch Strike
- Indicator Light Diffuser
- RJ-45 Cable Pass-Through Connectors
Lock State
UNLOCKED
LOCKED
Note: The door must be pushed in to fully engage the latch.
Credentials
RFID Card RFID Sticker RFID Keyfob
RFID Wristband Mobile ID
Management App
DigiLink App
Roles & Permissions
Note: System Admins have access to ALL sites. Site Admins and Remote Managers have access to only the sites to which they have been given permissions.
ROLES|
System Admin
| Site Admin| Remote Manager | Local Manager |
User
---|---|---|---|---|---
PERMISSIONS|
Create Site
|
| | | |
Add Users, Managers, & Locks
| | | | |
Disable Users & Locks
| | | | |
Assign Locks to Users
| | | | |
Edit Users & Locks
| | | | |
Access Dashboard & Reports
| | | | |
Remote Unlock
| | | | |
Override Locks in Person
| | | | |
Operate Locks
| | | | |
† Managers must be assigned to the locks to override.
SHARED USE – PIVOT PRO OPERATING INSTRUCTIONS
In shared use functionality, the locks are available when they have a green LED, and any user can use the available lock. A lock is operated by presenting any compatible RFID or Mobile ID credential. Once occupied, the lock will have a red LED. A credential from that same user must be used to unlock the lock. Once vacated and the door is secured, the lock is available for a different user and will display a green LED.
Operate with a User RFID or Mobile ID Credential
TO OCCUPY
Present any user RFID or Mobile ID credential at the lock.
The door will disengage, and the LED will turn red.
To secure, firmly push the door shut until it clicks into place.
TO VACATE
Present the same user RFID or Mobile ID credential.
The door will disengage, and the LED will turn green.
To secure, firmly push the door shut until it clicks into place.
The lock is now available for another user.
ASSIGNED USE – PIVOT PRO OPERATING INSTRUCTIONS
In assigned use functionality, the locks will always have a red LED. In this functionality, the user(s) must be assigned to the lock(s). The user presents an assigned user credential to operate the lock.
Operate with an Assigned RFID or Mobile ID Credential
TO OCCUPY
Present an assigned user RFID or Mobile ID credential.
The door will disengage and the LED will remain red.
To secure, firmly push the door shut until it clicks into place.
TO VACATE
Present an assigned user RFID or Mobile ID credential.
The door will disengage, and the LED will remain red.
To secure, firmly push the door shut until it clicks into place.