BRESSER 7000025000000 Thermo Hygro Quadro Neo Hygrometer Instruction Manual

June 6, 2024
BRESSER

Thermo-Hygrometer
Thermo Hygro Quadro Neo

Instruction manual

Visit our website via the following QR Code or web link to find further information on this product or the available translations of these instructions.

http://www.bresser.de/P7000025000000

WARRANTYwww.bresser.de/warranty_terms

**Imprint

**

Bresser GmbH
Gutenbergstr. 2
46414 Rhede
Germany
www.bresser.de

For any warranty claims or service inquiries, please refer to the information on “Warranty” and “Service” in this documentation. We ask for your understanding that unsolicited returns cannot be processed.
Errors and technical changes excepted.
© 2021 Bresser GmbH
All rights reserved.

The production of this documentation – even in extracts in any form (e.g. photocopy, print, etc.) as well as the use and distribution by means of electronic systems (e.g. image file, website, etc.) without the prior written permission of the manufacturer is prohibited.

The designations and brand names of the respective companies used in this documentation are generally protected by trade, trademark, and/or patent law in Germany, the  European Union, and/or their countries.

**Validity note

**

This documentation is valid for the products with the following article numbers:
7000025000000
Manual version:
1021

Manual designation:
Manual_7000025000000_Thermo-Hygro-Quadro-Neo_ende_BRESSER_v102021a
Always provide information when requesting service.

**About this Instruction Manual

**

NOTICE
These operating instructions are to be considered a component of the device.
Read the safety instructions and the operating manual carefully before using this device.
Keep this instruction manual in a safe place for future reference. When the device is sold or given to someone else, the instruction manual must be provided to the new owner/ user of the product.

Parts overview and scope of delivery


Illustration 1: All parts of the base station (top) and wireless sensor (bottom)

  1. Display* (base station)
  2. [SNOOZE / LIGHT] button
  3. [UP ] button
  4. [DOWN] buttons
  5. [ROOM] buttons (1-3)
  6. Wall mount (base station)
  7. [RESET] knob
  8. [SET] button
  9. [ALARM] button
  10. [ALARM] button
  11. Stand (foldable)
  12. Temperature display
  13. Channel display
  14. Humidity display
  15. Function indicator
  16. Wall mount (wireless sensor)
  17. [°C/°F] button
  18. Channel slider
  19. Battery compartment (wireless sensor)

Delivery content
The base station (A), wireless sensor (3 pcs.)(B)

Also required (not included):
9 pcs. Mignon batteries (1.5V, type AAA/LR03), small Phillips screwdriver
*For more information, refer to the chapter “Screen display”

Screen display

BRESSER 7000025000000 Thermo Hygro Quadro Neo Hygrometer - Screen
display

Illustration 2: Indications on the display of the base station

  1. Battery status (base station)
  2. The symbol for the indoor display
  3. Trend arrow
  4. Indoor temperature
  5. Indoor humidity (in %)
  6. Battery status (wireless sensor)
  7. Outdoor humidity (wire-less sensor)
  8.  Outdoor temperature (wireless sensor)
  9. Room description (for sensor location)
  10. The symbol for active snooze function
  11. current time or alarm time
  12. AM/PM display in 12hour mode
  13. The symbol for enabled alarm
  14. The symbol for active time zone setting
  15. Radio clock signal reception icon
  16. The symbol for active daylight saving time
  17. Current date
  18. Current day of the week
  19. The symbol for connection to the wireless sensor
  20. Channel of the radio sensor

Before commissioning

NOTICE
Avoid connection faults!

In order to avoid connection problems between the devices, the following points must be observed during commissioning.

  1. Place the base unit (receiver) and sensor (transmitter) as close together as possible.
  2. Connect the power supply to the base unit and wait until the indoor temperature is displayed.
  3. Establish a power supply for the sensor.
  4. Set up/operate the base unit and sensor within the effective transmission range.
  5. Make sure that the base unit and the radio sensor are set to the same channel.

When changing the batteries, always remove the batteries in both the base unit and the sensor and reinsert them in the correct order so that the radio connection can be re-established. If one of the two devices is operated via a mains power connection, the power connection for this vice must also be disconnected briefly when changing the battery. If, for example, only the batteries in the sensor are replaced, the signal cannot be received or can no longer be received correctly.

Note that the actual range depends on the building materials used in the building and the position of the base unit and outdoor sensor. External influences (various radio transmitters and other sources of interference) can greatly reduce the possible range. In such cases, we recommend finding other locations for both the base unit and the outdoor sensor. Sometimes a shift of just a few centimeters is enough!

Setting up power supply

Base unit

  1. Remove the battery compartment cover.

  2. Insert the batteries into the battery compartment. Make sure that the battery terminals are correctly aligned (+/-).

  3. Replace the battery compartment cover.

  4. Wait until the indoor temperature is displayed on the base unit. Wireless sensor

  5. Remove the screws on the battery compartment cover with a suitable Phillips screwdriver and remove the battery compartment cover.

  6. Move the channel slider to the desired channel.
    NOTICE! This Thermo-Hygrometer can be operated with up to 3 wireless sensors.
    Each connected wireless sensor must be operated on a different channel.
    If only one wireless sensor is connected, it should be operated on channel 1.

  7. Insert the batteries into the battery compartment. Make sure that the battery terminals are correctly aligned (+/-).

  8. Replace and screw on the battery compartment cover.

Battery level indicator

  1. When the level of the batteries in the base station or in the wireless sensor reaches a critical level, the battery level symbol appears in the appropriate area n the display.
  2. When replacing one set of batteries, always remove the batteries from the other part of the unit and reinsert them in the correct order (see chapter  Setting up power supply”). Replace the batteries to be changed in the corresponding part of the device with a completely new set with full capacity. This ensures that the connection between the devices will be reestablished again correctly.

Automatic time setting

After the power is restored, the unit automatically searches for the radio signal. It takes about 3-8 minutes to complete this process. If the radio signal is received correctly, the date and time are set automatically and the reception symbol is displayed.

If no radio signal is received, proceed as follows:

  1. Press the DOWN button for approx. 2 seconds to initiate the reception of the radio signal again.
  2. If no radio signal is still received, the time setting must be made manually.

Manual time setting

NOTICE! A manual time setting cannot be made when the time signal search is active (the corresponding symbol flashes). Wait until the time signal search s completed to make the manual time setting.

  1. Press the SET button for approx. 3 seconds to enter the time setting mode.
  2. Digits to be set are flashing.
  3. Press UP or DOWN button to change the value.
  4. Press the SET button to confirm and switch to the next setting.
  5. Settings sequence: Hours > Minutes > 12/24 hour mode > Year > Month > Day > Time zone > Language
  6. Finally, press the SET button to save the settings and exit settings mode.

*The language setting refers to the days of the week as well as to the room names. Available languages: English, German, French, Spanish, Italian, Danish,
Swedish

Time zone setting

The time zone is set as part of the manual time setting. You can also find more detailed information in the chapter “Manual time setting”.

  1. Press the SET button for approx. 3 seconds to enter the time setting mode.
  2. Press the SET button several times until the display shows the setting for the time offset (the factory setting is ’00’).
  3. Press the UP or DOWN button to select the desired time deviation in hours (-23 up to +23 hours).
  4. Press the SET button for approx. 3 seconds to confirm the selected time deviation.

Alarm setting

NOTICE! The alarm setting cannot be made when the time signal search is active (the corresponding symbol flashes). Wait until the time signal search is completed to be able to set the manual alarm.

  1. Press the Alarm button to display the alarm time.

  2. Press the Alarm button for approx. 2 seconds to enter the alarm time settings mode.

  3. Digits to be set are flashing.

  4. Press the UP or DOWN button to change the value.

  5. Press the ALARM button to confirm the entry and move to the next setting.

  6. Settings sequence: Hours > minutes

  7. Finally, press the ALARM button to save the settings and exit the settings mode.
    Enable/disable the alarm

  8.  In normal display mode, press the ALARM button to display the currently set alarm time. The alarm time and the alarm status (ON/OFF) are displayed.

  9. Press the UP button to activate the wake-up call (ON). The symbol will be displayed on the LCD.

  10. Press the SET button again to deactivate the wake-up call.  The symbol is no longer displayed.

**Snooze function

**

  1. When the alarm tone sounds, press the SNOOZE/ LIGHT button on the top of the base station to activate the snooze function. The alarm sounds again after 5 minutes.
  2. When the alarm sounds, press any other button to stop the alarm until the set alarm time is reached again. 3. If no button is pressed, the alarm is automatically switched off after 2 minutes.

NOTICE! The snooze function can be reactivated up to seven times before the alarm is automatically stopped.

Change room name

NOTICE! The room name cannot be changed when the time signal search is active (the corresponding icon flashes). Wait until the time signal search is completed to be able to change the room name.

  1. Press the ROOM button of the desired wireless sensor. The room name flashes.
  2. Press the ROOM button repeatedly to select one of the  5 preset room names. Alternatively, continue with 3. or wait approx. 5 seconds until the change has been saved automatically. The display stops flashing.
  3. Press the UP button to switch to the entry of a free room designation. “_” flashes.
  4. Press the UP button until the desired input value flashes. Possible input values: A-Z, 0-9, _ > < / * –
  5. Press the ROOM button again to switch to the next input value and enter it as described under 4.
  6. Finally, press the ROOM button to save the entry. If no entry is made within 5 seconds, the settings made up to this point are automatically saved. In both cases, the display stops flashing and the free input is stored.

Receiving measurements automatically

Once batteries are installed, the base station will display the measurement readings. Readings from the remote sensor will be displayed within 3 minutes after powering it on.

Display change °C/°F

• Base unit
In normal display mode, press the DOWN button to toggle between °C and °F.

Wireless sensor
Open the battery compartment.
Press the °C/°F button to toggle between °C and °F.
Close the battery compartment again.

Trend arrow indicators

1 Rising
2 Steady
3 Falling

The temperature and humidity trend indicator shows the trends of changes in the forthcoming few minutes. Arrows indicate a rising, steady or falling trend.

MAX/MIN weather data

The maximum and minimum readings for indoor and outdoor temperature as well as for the humidity are stored by the base station over a period of 24  hours:

  1. Press the UP button several times to display the stored values one after the other.
  2. Display sequence: Maximum readings (MAX) > Minimum readings (MIN) > Current readings
  3. Press the UP button for approx. 2 seconds to permanently delete all stored readings.

NOTICE! If reading is below the recordable range, the display shows “LL.L”. If reading is above the recordable range, the display shows “HH.H”.

Backlight

Press the SNOOZE/LIGHT button to activate the backlight for 5 seconds.

EC declaration of conformity

A “Declaration of conformity” in accordance with the applicable directives and corresponding standards has been prepared by Bresser GmbH. The full-text f the EC declaration of conformity is available at the following Internet address: www.bresser.de/download/7000025000000/ CE/7000025000000_CE.pdf

UKCA Declaration of Conformity

Bresser GmbH has issued a “Declaration of Conformity” in accordance with applicable guidelines and corresponding standards. The full text of the UKCA declaration of conformity is available at the following internet address: www.bresser.de/download/7000025000000/ UKCA/7000025000000_UKCA.pdf Bresser UK Ltd. • Suite 3G, Eden House, Enterprise Way, Edenbridge, Kent TN8 6HF, Great Britain

Warranty

The regular warranty period is 5 years and starts on the day of purchase. For full warranty terms and services, please visit www.bresser.de/warranty_terms.

Disposal

Dispose of the packaging materials properly, according to their types, such as paper or cardboard. Contact our local waste disposal service or environmental authority for information on the proper disposal.

Do not dispose of electronic devices in the household garbage!
According to the European Directive 2012/19/EU on Waste Electrical and Electronic Equipment and its transposition into national law, used electrical equipment must be collected separately and recycled in n environmentally sound manner.

Batteries and rechargeable batteries must not be disposed of with household waste. You are legally obliged to return used batteries and accumulators and return the batteries after use either in our sales outlet or in the immediate vicinity (e.g. in the trade or in municipal collection points) free of charge.
Batteries and accumulators are marked with a crossed-out dustbin and the chemical symbol of the pollutant, “Cd” stands for cadmium, “Hg” stands for mercury and “Pb” stands for lead.BRESSER 7000025000000 Thermo Hygro Quadro
Neo Hygrometer - icon11

Bresser GmbH
Gutenbergstraße 2
46414 Rhede · Germany
www.bresser.de
@BresserEurope

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

BRESSER User Manuals

Related Manuals