BRESSER 7006300 Tuya Smart Thermo-Hygrometer Instruction Manual

June 6, 2024
BRESSER

Tuya Smart Thermo-/Hygrometer
Art. No. 7006300
INSTRUCTION MANUAL

*Smartphone not included/Smartphone nichtenthalten
Visit our website via the following QR Code or web link to find further information on this product or the available translations of these instructions.

http://www.bresser.de/P7006300

GARANTIE · WARRANTY

www.bresser.de/warranty_terms

BresserSmart App Download:

http://www.bresser.de/download/BresserSmart

Scan to Download
BresserSmart App for Android / iOS

http://www.bresser.de/download/BresserSmart

Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Google Play and the Google Play logo are trademarks of Google Inc.

ABOUT THIS INSTRUCTION MANUAL

These operating instructions are to be considered a component of the device. Please read the safety instructions and the operating instructions carefully before use . Keep these instructions for renewed use at a later date. When the device is sold or given to someone else, the instruction manual must be provided to the new owner/user of the product. This product is intended only for private use. It was developed as an electronic medium for the use of multimedia services.

GENERAL WARNINGS

RISK OF CHOKING!
Keep packaging material, like plastic bags and rubber bands, out of the reach of children, as these materials pose a choking hazard.
RISK OF ELECTRIC SHOCK!
This device contains electronic components that operate via a power source (power supply and/or batteries) . Children should only use the device under adult supervision. Only use the device as described in the manual; otherwise, you run the risk of an electric shock .
RISK OF CHEMICAL BURN!!
Leaking battery acid can lead to chemical burns avoid contact of battery acid with skin, eyes and mucous membranes. In the event of contact, rinse the affected region immediately with plenty of water and seek medical attention.
RISK OF FIRE/EXPLOSION!
Use only the recommended batteries. Do not short-circuit the device or batteries, or throw them into a fire. Excessive heat or improper handling could trigger a short-circuit, a fire or an explosion.

NOTE!
Do not disassemble the device. In the event of a defect, please contact your dealer. The dealer will contact the Service Centre and can send the device in to be repaired, if necessary.
Do not immerse the unit in water.
Do not subject the unit to excessive force, shock, dust, extreme temperature or high humidity, which may result in malfunction,  shorter electronic life span, damaged batteries and distorted parts.
Use only the recommended batteries. Always replace weak or empty batteries with a new, complete set of batteries at full capacity. Do not use batteries from different brands or with different capacities. Remove the batteries from the unit if it has not been used for a long time.
The manufacturer is not liable for damage related to improperly installed batteries!

INTRODUCTION

Thank you for selecting the Tuya Smart Thermo-/Hygrometer. The console has a WIFI module built-in and through its smart system, it is compatible with the Tuya IOT platform. Through the BresserSmart App, you can view the temperature and humidity of the main console and wireless sensor(s), check history records, set high/low alarms and trigger tasks anywhere.
This system comes with a wireless thermo- hygro sensor and can support up to 7 additional sensors (optional) . The user can monitor and set multi-trigger tasks to control other Tuya compatible device(s) according to the specific condition(s).

The colorful LCD display shows the readings clearly and tidy, this system is IoT system for you and your home.
NOTE:
This instruction manual contains useful information on the proper use and care of this product. Please read this manual through to fully understand and enjoy its features, and keep it handy for future use.

OVERVIEW

CONSOLE

1 . [ALARM/SNOOZE ] key
2 . LCD display
3 . [ CHANNEL / + ] key
4 . [ MODE / ALARM ] key
5 . [ MAX / MIN / – ] key
6 . [ HI / LO ] slide switch| 7 . [ / CAL ] key
8 . [ TIME SET ] key
9 . Table stand
10 . Battery door
11 . Wall mounting hole
12 . [ °C / °F ] key| 13 . [ Refresh ] key
14 . [ RESET ] key
15 . [ SENSOR / WI-FI ] key
16 . Power jack
---|---|---

LCD DISPLAY
  1. Time & Date
  2. Temperature & humidity
  3. Indoor temperature & humidity
WIRELESS THERMO-HYGRO SENSOR
  1. LED indicator
  2. Wall mounting holder
  3. Channel slide switch
  4. [ RESET ] key
  5. Battery compartment

INSTALLATION AND SETUP

INSTALL WIRELESS THERMO-HYGRO SENSOR
  1. Remove the battery door of the sensor.
  2. Use the channel slide switch to set the channel number for the sensor (e .g . Channel 1)
  3. Insert 2 x AA-size batteries into the battery compartment according to the polarity marked on the battery compartment, and close the battery door.
  4. The sensor is in synchronization mode and can be registered to the console within the next few minutes. The transmission status LED will begin to flash every 1 minute.

NOTE:
– If you need to re-assign the sensor channel, slide the channel slide switch to the new channel position and press the [ RESET ] key on the sensor for the new channel number to be effective.
– Avoid placing the sensors in direct sunlight, rain or snow.
– To avoid the sensor/s and console pairing failure during new console setup, please power up the sensor(s) first, and then press the [ SENSOR/WiFi ] key on the main unit .

PLACING THE WIRELESS THERMO-HYGRO SENSOR
Place a screw on the wall that you wish to hang the sensor on.
Hang the sensor onto the screw by the wall mounting holder. You can also place the sensor on a table by itself.

SET UP THE CONSOLE

INSTALL THE BACKUP BATTERY
The backup battery provides power to the console to retain clock time and date, max/min records and calibration value.

NOTE:
– The backup battery can back up: Time & Date, Max/Min records and calibration value.
– The built-in memory can back up: Router setting server settings.
POWER UP THE CONSOLE

  1. Plugin the power adapter to power up the console.
  2. Once the console is power-up, all the segments of the LCD will be shown.
  3. The console will automatically enter AP mode and sensor synchronization mode automatically.
  4. The wireless sensor will automatically pair up with the console (about 1 minute). Upon successful synchronization, the display will change from “– .-°C –%” to actual reading.

NOTE:
If no display appears when power up the console. You can press the [ RESET ] key by using a pointed object. If this process still does not work, you can remove the backup battery and unplug the adaptor then re-power up the console again.
RESET AND FACTORY HARD RESET
To reset the console and start again, press the [ RESET ] key once or remove the backup battery and then unplug the adapter. To resume factory settings and remove all data, press and hold the [ RESET ] key for 6 seconds.

CHANGING BATTERIES AND MANUAL PAIRING OF SENSOR
Whenever you changed the batteries of the wireless sensor, re- synchronization must be done manually.

  1. Change all the batteries to new ones in the sensor.
  2. Press the [ SENSOR / WI-FI ] key on the console to enter sensor Synchronization mode.
  3.  The console will re-register the sensor after its batteries are changed (about 1 minute).
ADDITIONAL WIRELESS SENSOR(S) (OPTIONAL)

The console can support up to 7 wireless sensors.

  1. In the new wireless sensor, slide the Channel switch to a new CH number
  2. Press the [ RESET ] key on the new sensor.
  3. At the back of the console, press the [ SENSOR / WI-FI ] key enter sensor synchronization mode
  4. Wait for the new sensor(s) to pair up with the console. (about 1 minute)
  5. Once the new sensor(s) are connected to the console successfully, their temperature and humidity will be shown accordingly.

NOTE:
– Channel number of the sensor must not be duplicated among the sensors. Please refer to “INSTALL Wireless Thermo-hygro SENSOR” for details
– This console can support different type of additional wireless sensor(s), e.g. soil moisture. If you would like to pair up additional sensors, please check with your retailer for more detail.

SENSOR(S) RESYNCHRONIZATION
Press the [ SENSOR / WI-FI ] key once for the console to enter sensor Synchronization mode (channel number blinking), and the console will re- register all the sensors that have already been paired to it before.
REMOVE WIRELESS SENSOR
Users may manually delete any sensor from the console.

  1. Press the [ CHANNEL ] key until the console shows the display of the selected sensor.
  2. Press and hold [ REFRESH ] key for 10 seconds, until its readings are reset ” — , -°C — % ” is shown.

BRESSERSMART APP

ACCOUNT REGISTRATION

The console works with the BresserSmart App for Android and iOS smartphones.

  1. Scan the QR code to go to the BresserSmart download page.
  2. OR Download the BresserSmart App from Google Play or Apple App store .
  3. Install the BresserSmart App .
  4. Follow the instructions to create your own account using the phone number or email.
  5. Once the account registration is completed, the Home Screen will be shown.

Scan to Download
BresserSmart App for Android / iOS

http://www.bresser.de/download/BresserSmart

NOTE:
– There is no Registration code needed if the email method is chosen.
– The App may be subject to change without notice.
– You may be prompted to allow the App to have access to your location. This will allow the app to give you general weather information in your area. The app will still work if you don’t allow access to that.

CONNECT WEATHER STATION TO WIFI NETWORK
  1. Press and hold the [ SENSOR / WI-FI ] key for 6 seconds to enter AP mode manually, indicated by blinking AP and . When the console is powered up for the first time, the console will automatically enter and stay at AP mode.
  2. Open BresserSmart App and follow the in-app instructions to connect the weather station to your Wi-Fi network. 3. The console will automatically exit AP mode and return to normal operation once it’s connected to a Wi-Fi router.

NOTE :
– Smart weather station can only connect to 2.4G WI-FI network
– Enable the location information in your mobile when you add your console to App.
– User may press and hold [ SENSOR / WI-FI ] for 6 seconds to exit AP mode at any time.

DEVICE SCREEN OVERVIEW

The device screen can show the IN and (CH) Channel’s readings, max/min records, and access to graphs, alert setting, alert history and unit conversion.

  1. Temperature and humidity reading with max/min records for INDOOR
  2. Temperature and humidity reading with max/min records for wireless sensor (CH1 – CH7)
  3. Back to home page icon
  4. Device management for advanced feature and firmware update
  5. View the alert history
  6. Setting for alert notification
  7. Change temperature unit

TO VIEW THE HISTORY GRAPH
You can view the history graph by tapping the INDOOR or CH region in the “device page”. TO SET ALERT NOTIFICATION
You can set the temperature and humidity high / low alarm.

AUTOMATION WITH OTHER DEVICES USING BRESSERSMART
IOT APPLICATIONS

Through the BresserSmart App, you can create the temperature and humidity trigger conditions to control another BresserSmart compatible device (s) automatically.

NOTE :
– Any tasks required or performed by third-party devices are at the user’s own choice and risk.
– Please note no guarantee can be assumed regarding the correctness, accuracy, uptodateness, reliability and completeness of IoT applications.

FIRMWARE UPDATE

The console can be updated through your WI-FI network. If new firmware is available, a notification or pop-up message will be shown on your mobile when you open the App. Follow the instruction in the App to do the update.

During the update process, the console will show the progress status percentage at the bottom of the screen. Once the update is complete, the console screen will reset and back to normal mode. Please ignore the App update fail message if the console can restart and show the normal screen after the update process is completed.

IMPORTANT NOTE:
– Please keep connecting the power during the firmware update process.
– Please make sure your console WI-FI connection is stable.
– When the update process start, do not operate the console until the update is finished.
– Settings and data may be lost during updates.
– During firmware update the console will stop uploading data to the cloud server. It will reconnect to your WI-FI router and upload the data again once the firmware update succeeds. If the console cannot connect to your router, please enter the SETUP page to setup again.
– The firmware update process have potential risk, which cannot guarantee 100% success. If the update fail, please redo the above step to update again.
– If firmware update fail, press and hold the [C/F] and [REFRESH] key at the same time with 10 seconds to back to the original version, then redo the update procedure again.

OTHER SETTINGS & FUNCTIONS OF THE CONSOLE

MANUAL CLOCK SETTING
This console is designed to obtain the local time by synchronizing with your local time. If you want to use it offline, you can set the time and date manually. During the first time startup, press and hold the [ SENSOR / WI-FI ] key for 6 seconds and let the console back to normal mode.

  1. In normal mode, press and hold the [ TIME SET ] key for 2 seconds to enter the setting.
  2. The setting sequence: 12/24 hour format→ Hour →Minute →Year→M-D/D-M→ format→ Month →Day→ Time sync →ON/OFF →weekday Language.
  3. Press [ + ] or [ – ] key to change the value . Press and hold the key for quick-adjust.
  4. Press the [ TIME SET ] key to save and exit the setting mode, or it will automatically exit the
    setting mode 60 seconds later without pressing any key.

NOTE:
– In normal mode, press [ TIME SET ] key to switch between year and date display.
– During the setting, you can back to normal model by press and hold [ TIME SET ] key for 2 seconds.

SETTING ALARM TIME
  1. In normal time mode, press and hold the [ MODE / ALARM ] key for 2 seconds until the alarm hour digit flashes to enter alarm time setting mode.
  2.  Press [ + ] or [ – ] key to change the value . Press and hold the key for quick-adjust.
  3. Press the [ MODE / ALARM ] key again to step the setting value to Minute with the Minute digit flashing.
  4. Press [ + ] or [ – ] key to adjust the value of the flashing digit.
  5. Press the [ MODE / ALARM ] key to save and exit the setting.

NOTE:
– In alarm mode, the “ ” icon will display on the LCD.
– The alarm function will turn on automatically once you set the alarm time.

ACTIVATING ALARM FUNCTION
  1. In normal mode, press the [ MODE / ALARM ] key to show the alarm time for 5 seconds.
  2. When the alarm time displays, press the [ MODE / ALARM ] key again to activate the alarm function.

When clock reaches the alarm time, alarm sound will start .
Where it can be stopped by the following operation:
– Auto-stop after 2 minutes alarming if without any operation and the alarm will activate again in the next day.
– By pressing the [ALARM / SNOOZE] key to enter snooze that the alarm will sound again after 5 minutes.
– By pressing and hold the [ALARM / SNOOZE] key for 2 seconds to stop the alarm and will activate again in the next day
– By pressing the [ MODE / ALARM ] key to stop the alarm and the alarm will activate again in the next day.

NOTE:
– The snooze could be used continuously in 24 hours.
– During the snooze, the alarm icon “ ” will keep flashing.

WIRELESS SENSOR SIGNAL RECEIVING
  1. The console display signal strength for the wireless sensor(s), as per table below:
    Signal strength of wireless sensor channel

  2. If the signal has discontinued and does not recover within 15 minutes, the signal icon will disappear. The temperature and humidity will display “Er” for the corresponding channel.

  3.  If the signal does not recover within 48 hours, the “Er” display will become permanent. You need to replace the batteries and then press [ SENSOR / WI-FI] key to pair up the sensor again .

VIEW THE OTHER CHANNELS (OPTIONAL FEATURE WITH ADD ON EXTRA SENSORS)
This console is capable to pair with 7 wireless sensors . If you have 2 or more wireless sensors, you can press the [ CHANNEL ] key to switch between different wireless channels in normal mode, or press and hold the [ CHANNEL ] key for 2 seconds to toggle auto-cycle mode to display the connected channels at 4 seconds interval.
During auto-cycle mode, the icon will show on the wireless sensor channels section of the console’s display . Press the [ CHANNEL ] key to stop auto cycle and display the current channel.

TEMPERATURE / HUMIDITY FUNCTION

– The temperature and humidity readings are displayed on the Channel and indoor section.
– Use the [ °C / °F ] key to select the temperature display unit.
– If temperature/humidity is below the measurement range, the reading will show “LO” . If temperature/humidity is above the measurement range, the reading will show “HI”.

COMFORT INDICATION
The comfort indication is a pictorial indication based on indoor air temperature and humidity in an attempt to determine comfort level.

NOTE:
– Comfort indication can vary under the same temperature, depending on the humidity.
– There is no comfort indication when the temperature is below 0°C (32°F) or over 60°C (140°F).

TREND INDICATOR
The trend indicator shows the temperature or humidity trends of changes based on the later 15 minutes. MAX / MIN DATA RECORD
The console can record MAX / MIN readings both daily and since last reset.

TO VIEW MAX / MIN
  1. In normal mode, press the [ MAX / MIN ] key on the front side, to check the daily MAX records of the current channel and indoor.
  2. Press the [ MAX / MIN ] key again to check the daily MIN records of the current channel and indoor.
  3. Press [ MAX / MIN ] key again to check the accumulative MAX records.
  4. Press [ MAX / MIN ] key again to check the accumulative MIN records.
  5. Press the [ MAX / MIN ] key again and back to normal mode.
  6. Users can also check records of the different sensors by pressing the [ CHANNEL ] key.
TO RESET THE MAX/MIN RECORDS

Press and hold the [ MAX / MIN ] key for 2 seconds to reset the current on display MAX or MIN records.

NOTE:
The LCD will also display the icon, when showing the record(s).

CALIBRATION

To calibrate the temperature and humidity:

  1. In normal mode, press and hold [ / CAL ] key for 2 seconds to enter the calibration mode as below.
  2. Press [ + ] or [ – ] key to select IN or any Channels .
  3.  Press [ MODE / ALARM ] key to select between Temperature Humidity.
  4. While temperature or humidity is blinking, press [ + ] or [ – ] key to adjust the offset value.
  5. When finished, press [ MODE / ALARM ] to proceed with next calibration by repeating processes 2 – 4 above.
  6.  Press [ / CAL ] key to return to normal mode .
BACKLIGHT

The main unit backlight can be adjusted, using the [ HI / LO ] sliding switch to select the appropriate brightness:
– Slide to the [ HI ] position for the brighter backlight.
– Slide to the [ LO ] position for the dimmer backlight.

SET LCD DISPLAY CONTRAST

In normal mode, press [ / CAL ] key to adjust LCD contrast for best viewing on a table stand or wall-mounted.

MAINTENANCE

BATTERY REPLACEMENT

When the low battery indicator “ ” is displayed in CH section of the LCD display, it indicates that the current channel sensor battery power give wireless sensor shown is low respectively. Please replace with new batteries.

TROUBLESHOOT
Problems Solution
An indoor wireless sensor is intermittent or has no connection 1 . Make sure

the sensor is within the transmission range
2 . Make sure the channel displayed matches to the channel selection on the sensor
3 . If it still not work, reset the sensor and resynchronize with the console.
No WI-FI connection| 1 . Check for WI-FI symbol on the display, it should be always on.
2 . Make sure you connect to 2 .4G band but not 5G band of your WIFI
router.
Temperature or humidity not accurate| 1 . Do not place your console or sensor close to the heat source
2 . If the sensor still not accurate adjust the value in calibration mode

SPECIFICATIONS

CONSOLE

General Specification

Dimensions (W x H x D) 130 x 112 x 27.5mm (5.1 x 4.4 x 1.1 in)
Weight 220g (with batteries)
Main power DC 5V, 1A adaptor
Backup battery CR2032
Operating temperature range -5˚C ~ 50˚C
Operating Humidity range 10~90% RH
Support sensors  – 1 Wireless Thermo-hygro sensors (included)

– Support Up to 7 Wireless Thermo-hygro sensors (optional)
RF frequency| 868Mhz (EU or UK version)
Time Related Function Specification
Time display| HH: MM
Hour format| 12hr AM / PM or 24 hr
Date display| DD / MM or MM / DD
Time synchronize method| Through the server to get the local time of the console location
Weekday languages| EN / DE / FR / ES / IT / NL / RU
In Temperature
Temperature unit| °C and °F
Accuracy| <0°C or >40°C ± 2°C (<32°F or >104°F ± 3 .6°F)
0~40°C ±1°C (32~104°F ± 1 .8°F)
Resolution| °C / °F (1 decimal place)

In Humidity

Humidity unit| %
Accuracy| 1 ~ 20% RH ± 6 .5% RH @ 25°C (77°F)
21 ~ 80% RH ± 3 .5% RH @ 25°C (77°F)
81 ~ 99% RH ± 6 .5% RH @ 25°C (77°F)
Resolution| 1%
WI-FI Communication Specification
Standard| 802 .11 b/g/n
Operating frequency :| 2 .4GHz
Supported router security type| WPA/WPA2, OPEN, WEP (WEP only support Hexadecimal password)
APP Specification
Support App| #NAME?
The supported platform of App| Android Smartphone
WIRELESS THERMO-HYGRO SENSOR
Dimensions (W x H x D)| 60 x 113 x 39.5mm (2.4 x 4.4 x 1.6in)
Weight| 126g (with batteries)
Main power| 2 x AA size 1.5V batteries
Weather data| Temperature and Humidity
RF transmission range| 150m
RF frequency| 868Mhz (EU, UK)
Transmission interval| 60 seconds for temperature and humidity
Operating range| -40 ~ 60°C (-40 ~ 140°F)  Lithium batteries required
-19 .9 ~ 5°C ± 1°C (-3 .8 ~ 41°F ± 1 .8°F)
-40 ~ -20°C ± 1 .5°C (-40 ~ -4°F ± 2 .7°F)
Operating humidity range| 1 ~ 99% RH
CH (wireless sensor) Temperature
Temperature unit| °C and °F
Accuracy| 5 .1 ~ 60°C ± 0 .4°C (41 .2 ~ 140°F ± 0 .7°F)
Resolution| °C / °F (1 decimal place)
CH (wireless sensor) Humidity
Humidity unit| %
Accuracy| 1 ~ 20% RH ± 6 .5% RH @ 25°C (77°F)
21 ~ 80% RH ± 3 .5% RH @ 25°C (77°F)
81 ~ 99% RH ± 6 .5% RH @ 25°C (77°F)
Resolution| 1%

CLEANING AND MAINTENANCE

Before cleaning the device, disconnect it from the power supply (remove power supply and/or batteries)!
Only use a dry cloth to clean the exterior of the device. To avoid damaging the electronics, do not use any cleaning fluid.

DISPOSAL

Dispose of the packaging materials properly, according to their type, such as paper or cardboard. Contact your local waste disposal service or environmental authority for information on the proper disposal.

****Do not dispose of electronic devices in the household garbage!
As per Directive 2002/96/EC of the European Parliament on waste electrical and electronic equipment and its adaptation into German law, used electronic devices must be collected separately and recycled in an environmentally friendly manner.

In accordance with the regulations concerning batteries and rechargeable batteries, disposing of them in normal household waste is explicitly forbidden. Please make sure to dispose of your used batteries as required by law — at a local collection point or in the retail market. Disposal in domestic waste violates the Battery Directive. Batteries that contain toxins are marked with a sign and a chemical symbol . “Cd” = cadmium, “Hg” = mercury, “Pb” = lead .

EC DECLARATION OF CONFORMITY

Hereby, Bresser GmbH declares that the equipment type with part number: 7006300 is in compliance with Directive: 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:
http://www.bresser.de/download/7006300/CE/7006300_CE.pdf

UKCA DECLARATION OF CONFORMITY

Bresser GmbH has issued a “Declaration of Conformity” in accordance with applicable guidelines and corresponding standards. The full text of the UKCA declaration of conformity is available at the following internet address:
www.bresser.de/download/7006300/UKCA/7006300_UKCA.pdf
Bresser UK Ltd. • Suite 3G, Eden House, Enterprise Way, Edenbridge, Kent TN8 6HF, UK

WARRANTY & SERVICE

The regular guarantee period is 5 years and begins on the day of purchase. You can consult the full guarantee terms and details of our services at www.bresser.de/warranty_terms.

Please contact the service center first for any questions regarding the product or claims, preferably by e-mail.
E-Mail: service@bresseruk.com
Telephone: +44 1342 837 098
BRESSER UK Ltd.
Suite 3G, Eden House
Enterprise Way
Edenbridge, Kent TN8 6HF
United Kingdom
Number charged at local rates in the UK (the amount you will be charged per phone call will depend on the tariff of your  hone
provider); calls from abroad will involve higher costs.
Contact

Bresser GmbH
Gutenbergstraße 2
46414 Rhede
Germany| Bresser UK Ltd.
Suite 3G, Eden House
Enterprise Way, Edenbridge,
Kent TN8 6HF, UK
---|---

www.bresser.de

@BresserEurop
Errors and technical changes reserved.
Manual_7006300_Tuya-Smart-Thermo-Hygrometer_en-de-fr-nl-es_BRESSER_v102021a

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

BRESSER User Manuals

Related Manuals