WAVETREND Sigfox Water Temperature Monitor Installation Guide

June 6, 2024
WAVETREND

Water Temperature Monitor
Installation Guide
Document Version 1.0

Preface

About this Guide

This User Guide contains instructions for Wavetrend’s Water Temperature Monitor.
This Preface contains important information which should be read before getting started.

Important Information

Copyright
Copyright © 2021 Wavetrend Europe Ltd. All rights reserved.
No part of this publication may be reproduced, transmitted, stored in a retrieval system, nor translated into any human or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior written permission of the copyright owner, Wavetrend  Europe Ltd., Unit 1, Barlavington Stud, Barlavington, Petworth, GU28 0LG, United Kingdom.
Copyright infringement is a serious matter under English and foreign Copyright Laws.

Trademarks
Microsoft ®, is a registered trademark, Windows™, Windows XP™, Windows Vista ™, Windows 7™, Windows 8™, Windows 10™ and the Windows Logo are registered trademarks of the Microsoft Corporation of the United States and/or other countries.
UNIX® is a registered trademark of AT&T in the USA and other countries.
IBM® is a registered trademark of International Business Machines Corporation.
Names of products, brands, etc. appearing in this manual are trademarks or registered trademarks of their respective own companies.
Disclaimer
Information in this document is subject to change without notice and does not represent a commitment on the part of Wavetrend Europe Limited. The Water Temperature Monitor described is subject to change without notice. Wavetrend Europe Limited assumes no liability for damage incurred directly or indirectly from errors, omissions, or discrepancies between the device and the guide.

Product Description

Overview

Wavetrend’s Water Temperature Monitor enables businesses to cost-effectively meet their statutory obligations to provide healthy water and safe supply systems.
The risk of legionella bacterium, together with scalding and freezing conditions, is mitigated by actively monitoring hot, cold, and blended outflows.
Alerts and daily reports are provided via the LoRaWAN network to ensure that timely action can be taken.
With a battery life of over 10 years, the device provides an attractive alternative to traditional inspection visits.
Wavetrend’s Water Temperature Monitor has the following features and benefits:

Daily reports Enables statutory record keeping requirements to be met

Real time
temperature alerts| Allows proactive and timely response, for example to scald events
Easy installation| Clip-on pipe sensors and flanged screw mount enclosure mean fast , straightforward installation
Configurable temperature thresholds| Flexibility to configure individual devices based on local health and safety regulations
Over-the-air configuration| Allows device configuration to be updated whilst in-service and ensures real-time clock synchronization
LoRaWAN radio
performance| Robust communication ensures reliable delivery of report messages
Long battery life| Long service life with minimal maintenance visits

What’s in the Box

One Water Temperature Monitor consisting of rectangular white ABS enclosure. Temperature sensors are supplied separately and are not packaged with the Water Temperature Monitor.

Product Installation

Installation Overview

The installation process consists of the following:

  1. Installing the device
  2. Attaching sensors to pipework
  3. Connecting sensors to the device

N.B. Sensors should not be connected to the device before steps 1 & 2 otherwise installation may fail.

Installing the Device

The device is typically installed in a cupboard under a sink:
– The device should be mounted in portrait orientation with the temperature sensor connectors facing downwards.
– The device must not be mounted on metal and should be clear of any objects around it.
– At each end of the enclosure are flanges with holes provided for screw mounting.
Alternatively good quality double-sided sticky pads or Velcro can be used to hold in place.
A typical installation is as follows:

Attaching sensors to pipework

Temperature sensors should be fixed in place before connecting to the device.
A suitable pipe location for each of the sensors should be identified, as near to the outflow as possible. If the pipe is painted this should be removed if possible before installing each sensor.
Sensors are simply clipped over a pipe. They should be pushed firmly in place.
A typical installation is as follows:

Connecting sensors to the device

Sensors should be connected to the device in the following sequence: 3,2,1. Refer to your chosen device configuration for mapping of pipes to sensor numbers.
Connecting sensor 1 activates the device at which time it will send an installation message and attempt a downlink message to get its configuration.
Sensors must be connected in the correct positions, which are as follows:

Following sensor connection, any spare sensor lead should be coiled, cable tied, and secured neatly out of the way such that it won’t be inadvertently disturbed.
Copyright © 2021, Wavetrend Europe Ltd.
Document Version 1.0
Produced by Wavetrend (Europe)
Ltd Wavetrend Europe Ltd
Barlavington Stud
Barlavington
Petworth
West Sussex
GU28 0LG
Phone: +44 (0) 330 223 2085
Copyright © 2021 Wavetrend Europe Ltd. All rights reserved.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals