The Intellicode® Three Door External Receiver has been designed to provide versatility with remote control applications for residential and commercial doors and gates. There are two primary modes of operation:
Three Door Mode: Supports up to 255 315/390MHz Intellicode® remote controls and an unlimited number of 390MHz fixed code remotes on up to three doors.
Single Door Open/Close/Stop Mode: Supports up to 255 Intellicode® Open/Close/Stop remotes on a single door using dual 315/390MHz frequencies.

WARNING
Moving Door/Gate can cause serious injury or death.

  • Wall Console must be mounted in sight of door/gate, at least 5 feet above floor and clear of moving parts.

  • Keep people clear of opening while door/gate is moving.

  • DO NOT allow children to play with the remote or door/gate opener.
    If SAFETY REVERSE does not work properly:

  • Close door/gate then disconnect opener using the manual release handle.

  • DO NOT use remote controls to operate door/gate.

  • Refer to Door/Gate Owners Manuals before attempting any repairs.

SPECIFICATIONS

GENIE 41488R External Three Door Receiver
fig1

  • Intellicode® Remote Capacity: 255

  • Fixed Code Remote Capacity: Unlimited

  • Voltage/Current/Hz:

    • Power Pack: 100-240VAC, 0.5A, 50-60Hz
    • Power Pack Output: 12VDC, 1A
    • Receiver Input Voltage: 9-42VDC, 200mA, 50-60 Hz or 9-30VAC, 200mA, 50-60 Hz
    • Temperature Range: -300F to 1580F

IMPORTANT NOTICE: This kit may only be used on an operator manufactured 1993 and later with working safety sensors.

PRE-INSTALLATION: For use on momentary contact capable units only

  • If existing receiver will no longer be used, erase remotes. Refer to existing receiver owners manual, if needed.
  • Determine power source and wire to receiver using figures 1, 2 or 3. Refer to operator owners manual, if needed.

INSTALLATION

  1. Unplug or turn off breaker that supplies power to operator.
  2. Find a suitable mounting point for receiver within a few feet of the operator.
  3. Mount receiver to wall or ceiling. Due to variations in mounting methods, hardware is not included.
  4. Strip ends of included bell wire and install between receiver and operator connections (Fig. 1-A) or commercial operator connections. If using the recommended power supply, plug connector from power pack into receiver (FIG.
  5. To wire for an alternate power supply application, see FIG. 2-3. For commercial operator operation with open/close/stop remotes, see FIG. 4
  6. Install coax antenna on to receiver coax connector.
  7. If using 115VAC power pack, plug power pack into standard 115VAC outlet.
  8. Use included staples to tidy any hanging wires.
  9. Restore power to operator.

WIRING

FIG. 1. Garage door or gate operator powered with 115VAC power pack.GENIE
41488R External Three Door Receiver fig2
FIG. 2. Garage door or gate operator powered from operator.GENIE 41488R
External Three Door Receiver fig3
FIG. 3. – Three-Wire commercial door or gate operator powered from operator.GENIE 41488R External Three Door Receiver
fig4
FIG. 4. Garage door operator powered from operator for Open/Close/Stop operation.GENIE 41488R External Three Door Receiver
fig5

PROGRAMMING RECEIVER

WARNING
During programming, the door opener could begin to run. Stay away from moving door and its parts. To prevent door from moving, close door using the wall button and disconnect it from opener by pulling Emergency Release Cord (See owners manual).
NOTE: Programming must be completed within 30 seconds of pressing programming button or receiver will turn off remote programming mode. Press button again to enable programming mode and resume programming remote.
NOTE: If receiver does not perform properly, check connections between power source and receiver and connections between receiver and operator
Programming Intellicode® Remotes (Three Door Mode):
Note: Open/Close/Stop remotes cannot be used in this mode.

Three Door Mode is the default factory setting. If an open/close/stop remote has been previously programmed to the receiver use the CLEAR ALL REMOTES instructions section below to reset the receiver into Three Door Mode.

  1. Press and release the door button on the receiver for the door you desire to use the remote with. The door LED will begin flashing.
  2. Press and release the remote button. The door LED will change to solid.
  3. Press the remote button a second time. The door LED will turn off.
  4. The next remote button press will activate the receiver.

Programming Intellicode® Open/Close/Stop Remotes (Single Door Open/Close/Stop Mode)
Note: Single button and fixed code remotes cannot be used in this mode.
Note that the first open/close/stop remote programmed to the receiver will change the mode from Three Door to Single Door Open/Close/Stop mode. If remotes have previously been programmed to the receiver in Three Door Mode, clear the receiver memory using the CLEAR ALL REMOTES instructions section.

  1. Press and release any door button on the receiver. The door LED will begin flashing.
  2. Press and release any button on the open/close/stop remote. The door LED will change to solid.
  3. Press the same remote button a second time. The door LED will turn off.
  4. The next remote button press will activate the receiver. All three buttons on the remote are now programmed.

Setting Fixed Code (Three Door Mode Only)
Each of the three door outputs can have a unique fixed code. Intellicode remotes can also be used on the same door as fixed code remote. This feature can be beneficial for transitioning away from fixed code to Intellicode® while old fixed code remotes are exchanged for Intellicode®.
Setting Fixed Code on Door X (X = 1, 2, or 3)
NOTE: Fixed code switch settings using all 9 switches in the (-), (o), or (+) positions are invalid codes and cannot be programmed.

  1. Remove power from the receiver.
  2. Remove two screws on the back of the unit.
  3. Remove the front cover.
  4. Set dip switches to desired code.
  5. Apply power to receiver.
  6. Press and hold all three door buttons simultaneously. All three LEDs will turn on solid for five seconds.
  7. When the LEDs turn off, release the buttons and all three LEDs begin flashing. Press and hold the door button for the door you want to set the fixed code on. The LED will flash three times and turn off. Release the button. Remote is now programmed for selected door.GENIE 41488R External Three Door Receiver fig6
  8. If desired to set fixed codes on other doors, repeat steps 4-7.
  9. Remove power from the receiver.
  10. Put the front cover back onto the receiver.
  11. Screw the cover on from the back with the two screws.
  12. Mount the receiver
  13. Apply power to the receiver.

Clear Intellicode® and Fixed Remotes on a Single Door (Three Door Mode Only)

  1. Press and hold the door button for the door you wish to clear remotes from. The LED will turn on solid.
  2. After approximately 20 seconds the LED will flash three times and turn off. Release the door button. All Intellicode and fixed code remotes have been cleared from the door.

Clear All Remotes (Three Door Mode or Single Door Open/Close/Stop Mode)

Press and hold all three door buttons simultaneously. After 20 seconds all three LEDs will flash three times and turn off. Release the buttons. All Intellicode® and fixed code remotes have been cleared from memory for all doors. Note that during the 20 second button press all three LEDs will turn off briefly twice then back on.