AIRMASTER 14 150L Belt Driven Air Compressor Instruction Manual

June 6, 2024
AirMaster

AIRMASTER logo

AIRMASTER 14 150L Belt Driven Air Compressor

AIRMASTER 14 150L Belt Driven Air Compressor

INTRODUCTION
Thank you for purchasing this 150L Belt Driven Air Compressor.
Read this manual fully before use and follow the instructions carefully. In doing so you will ensure the safety of yourself and those around you, and you can look forward to your purchase giving you long and satisfactory service.

GUARANTEE
This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt which will be required as proof of purchase.
This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended.
Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission.
This guarantee does not effect your statutory rights.

ENVIRONMENTAL RECYCLING POLICY
Through purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment, recycling & recovery and environmentally sound disposal of the WEEE.
In effect, this means that this product must not be disposed of with general household waste. It must be disposed of according to the laws governing
Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal facility.

SAFETY PRECAUTIONS

Before using your compressor it is in your own interest to read and pay attention to the following safety precautions.

  1. Compressed air is dangerous. DO NOT point a jet of air at persons or animals and do not discharge compressed air against the skin.
  2. DO NOT operate your compressor with the guard removed.
  3. Repairs must only be carried out by a qualified engineer. If problems occur, contact your Machine Mart dealer.
  4. Before carrying out any maintenance make sure that the pressure is released from the air reservoir and that the compressor is disconnected from the electrical supply.
  5. DO NOT leave pressure in the receiver overnight or when transporting.
  6. DO NOT adjust or tamper with the safety valves. The maximum pressure is factory set, and clearly marked on the compressor.
  7. DO NOT operate in wet or damp conditions. Keep the compressor dry at all times. Similarly, clean air will allow the compressor to work efficiently. DO NOT use in dusty or otherwise dirty locations.
  8. Some of the metal parts can become quite hot during operation. DO NOT touch/remove these until the compressor has cooled down.
  9. ALWAYS set the pressure regulator to the recommended setting for the tool.
  10. When spraying flammable materials e.g. cellulose paint, ensure that there is sufficient airflow and keep clear of any source of ignition.
  11. Before spraying any material always consult paint manufacturers instructions for safety and usage.
  12. Protect yourself. Goggles will protect your eyes from flying particles. Face masks will protect you against paint spray and fumes.
  13. DO NOT apply strain to electrical cables and make sure that air hoses are not kinked or wrapped around the compressor.
  14. When disconnecting air hoses or other equipment from your compressor, make sure that the air supply is turned off at the outlet and vent all pressurised air from within the reservoir and other equipment attached to it.
  15. Make sure that children and animals are kept well away from the compressor and any equipment attached to it.
  16. Make sure that all individuals using the compressor have had the necessary training and have read and fully understand these operating instructions.
  17. Make sure that any equipment or tool used in conjunction with your compressor, has a safe working pressure exceeding that of the compressor.
  18. Be careful when transporting the compressor to prevent tipping over
  19. Permanently installed systems must be installed by a competent engineer.
  20. This compressor produces noise levels in excess of 70dB(A). Persons working near the compressor must be supplied with ear protection.

SAFETY SYMBOLS

ELECTRICAL CONNECTIONS

WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS SUPPLY.

Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch.
If the plug has to be changed because it is not suitable for your socket, or because of damage, it must be removed and a replacement fitted, following the wiring instructions shown below. The old plug must be discarded safely, as insertion into a power socket could cause an electrical hazard.

WARNING: THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE: BLUE = NEUTRAL BROWN = LIVE YELLOW AND GREEN = EARTH

If the colours of the wires in the power cable do not agree with the markings on the plug.

  • The BLUE wire must be connected to the terminal which is marked N or coloured black.
  • The BROWN wire must be connected to the terminal which is marked L or coloured red.
  • The YELLOW AND GREEN wire must be connected to the terminal which is marked E or coloured green.

ELECTRICAL CONNECTIONS

We strongly recommend that this machine is connected to the mains supply through a Residual Current Device (RCD)
If you are not sure, consult a qualified electrician. DO NOT try to do any repairs.

BEFORE USE

CAUTION: TO PREVENT INJURY, GET ASSISTANCE WHEN LIFTING OR MOVING THIS COMPRESSOR.
Before connecting your compressor to the power supply, check the following:-

  • Set the ON/OFF switch to the OFF position (pushed down).
  • Make sure that the compressor is on level ground.
  • Make sure that the supply voltage matches the voltage shown on the data label.

BEFORE USE 1

CHECK THE OIL LEVEL

  1. Remove the dipstick from the oil reservoir.
  2. Ensure the oil level is between the min and max marks on the dipstick.
    • Only use ISO100 (SAE30) compressor oil, available from your Machine Mart dealer Part No. 3050796.
    • Take care not to exceed the maximum mark.BEFORE USE 2

OPERATION

If the compressor has not been used for more then 24 hours, open the drain valve (on the bottom of the reservoir) and drain any condensate which has collected. See page 10.

MOVING THE AIR COMPRESSOR

  • Stop the compressor and disconnect it from the power supply before you move it.
  • Do not lift by (or put strain on) valves or hoses.

ATTACHING AIR TOOLS

WARNING: BEFORE CONNECTING AIR TOOLS, MAKE SURE THAT YOU READ THE INSTRUCTIONS SUPPLIED WITH THE TOOL, ALSO ENSURE THAT THE TOOL IS SUITABLE FOR USE WITH THE COMPRESSOR AND HOSE SPECIFICATIONS.

OPERATION 1

  1. Fit the supplied tap to the compressor and attach the air hose to the tap.
  2. Attach the air tool to the other end of the air hose.
  3. Turn the tap handle to the open position.
    NOTE: The tap is shown without the air hose fitted for clarity.

TURNING THE COMPRESSOR ON

  1. Plug the compressor into the power supply.
  2. Lift the On/Off button.
    • The compressor will operate until the reservoir is fully pressurised. It will then shut down.
    • The compressor will start up again when the pressure in the reservoir decreases.

CHECKING THE SAFETY VALVE
To make sure that the safety valve works correctly;

  1. Unscrew and pull the knurled part of the safety valve.
    • Air will be released when you twist and stop when released.
  2. If the valve does not operate in this way, do not use the compressor. The compressor must be repaired by a qualified service agent.

OPERATION 3

WARNING: DO NOT REMOVE OR TRY TO ADJUST THE SAFETY VALVE.

REMOVING TOOLS FROM THE AIR HOSE
WARNING: ALWAYS SET THE PRESSURE REGULATOR TO ZERO BEFORE YOU REMOVE OR REPLACE A TOOL.

REMOVING TOOLS FROM THE AIR HOSE 1

  1. Push down on the On/Off button to stop the compressor.
  2. Turn the tap handle to the closed position.
  3. Operate the tool to depressurise the air hose.
  4. Disconnect the tool from the hose.

TURNING THE COMPRESSOR OFF

REMOVING TOOLS FROM THE AIR HOSE 2

  1. Follow steps 1-3 in “Removing Tools From The Air Hose” above.
  2. Disconnect the compressor from the power supply.
  3. Slowly open the tap to depressurise the reservoir.
    • You will hear a hissing sound as the reservoir depressurises.
  4. Do not leave the compressor unattended if the reservoir is pressurised.

DRAINING THE RESERVOIR
CAUTION: YOU MUST DRAIN THE RESERVOIR AFTER EACH DAYS USE AND BEFORE YOU PUT YOUR COMPRESSOR INTO STORAGE.

  1. Turn the compressor off and disconnect from the power supply.
  2. Put a container below the drain valve to collect the condensate.
    • The drain valve is located on the bottom of the reservoir
  3. Open the drain valve slowly.
    • Condensation will drain from the reservoir.
  4. Close the drain valve when the reservoir has fully drained.

USING THE RESET BUTTON

This compressor has a thermal overload device.
If the motor gets too hot, the thermal overload device cuts the power which prevents damage to the motor.
If the thermal overload device operates, let the motor cool down for 5 minutes and push the reset button.
If you start the compressor and the overload cutout operates again, stop the compressor and disconnect from the power supply and have your compressor examined by a qualified service agent.

USING THE RESET BUTTON

MAINTENANCE

WARNING: MAKE SURE THAT THE COMPRESSOR IS DISCONNECTED FROM THE ELECTRICAL SUPPLY BEFORE CARRYING OUT ANY MAINTENANCE

DRAIN THE RESERVOIR
After use, always open the drain valve to make sure that any condensate is drained off.

CHECK THE OIL
Ensure the oil level is between the min and max marks on the dipstick. See “Check the Oil level” on page 6 and top-up if necessary – (use ISO100 (SAE30) compressor oil, available from your Machine Mart dealer).

CLEAN THE AIR FILTER
The air filter must be examined monthly and more often in dusty conditions,

  1. Remove the securing bolt and pull the filter from the compressor.
  2. Unclip the front and rear of the filter and pull out the filter element.
  3. Clean the filter using a soft brush.
    • If necessary, the filter can be carefully cleaned in warm soapy water.
    • Rinse and let the filter dry completely before refitting.
    • If the filter or filter element is damaged, you must replace it.
  4. Reassemble the filter and refit it to the compressor using the securing bolt.

MAINTENANCE

REPLACING THE OIL
After the first 100 hours use, replace the oil using ISO100 (SAE30) compressor oil. Then replace the oil after every 500 hours of operation or every 6 months.
To empty the oil from the machine, remove the oil drain plug from the crankcase.

REPLACING THE OIL

CHECKING THE NON-RETURN VALVE
If the reservoir pressure decreases for no apparent reason it is possible that the non-return valve is leaking. To check this:

  1. Make sure that the reservoir is not under pressure and the compressor is switched OFF.
  2. Examine the non-return valve, and replace the gasket and valve if necessary.

CHECKING THE NON-RETURN VALVE

REPLACING THE DRIVE BELT
WARNING:
MAKE SURE THAT THE COMPRESSOR IS DISCONNECTED FROM THE ELECTRICAL SUPPLY BEFORE REPLACING THE DRIVE BELT.

  1. Rotate the clips on the front of the safety cage.
  2. Remove the front of the cage and take out the worn or broken drive belt.
  3. Place the new drive belt over the small wheel.REPLACING THE DRIVE BELT 1
  4. Position part of the drive belt over the large belt wheel as shown.
  5. Rotate the large belt wheel by hand in a clockwise direction whilst guiding the belt on to it.
    • Take care to avoid trapping your fingers between the wheel and belt.
  6. Replace the cage and secure before use.

REPLACING THE DRIVE BELT 2

WARNING: NEVER USE THE COMPRESSOR WITH THE GUARD REMOVED.

SPECIFICATIONS

MODEL AIRMASTER 14/150
Part Number 2245308
mOTOR pOWER 3 hp
Voltage 230 VAC (50Hz)
Air Displacement 394 L/min (14 cfm)
Max Pressure 10 Bar (145 psi)
Receiver Capacity 150 L
Ingress Protection IP20
Fuse Rating 13 A
Duty cycle S3/50%
Oil requirements ISO100 (SAE30) compressor oil
Oil capacity 0.4L
Dimensions (L x W x H) 1270 x 450 x 820 mm
Guaranteed Sound Power Level 97 dB(A)
Weight 83 kg

Please note that the details and specifications contained herein, are correct at the time of going to print. We reserve the right to change specifications at any time without prior notice.

TROUBLESHOOTING

CAUTION: DO NOT TRY TO REPAIR OR ADJUSTMENT IF YOU ARE UNCERTAIN. IF YOU HAVE ANY QUERIES, CONTACT YOUR CLARKE DEALER.

PROBLEM PROBABLE CAUSE REMEDY
The compressor has stopped and does not start. Bad electrical connections.
  1. Check electrical connections.
  2. Clean and tighten if necessary.

Overload cutout switch has tripped.|

  1. Switch off and wait approx 5 minutes.
  2. Press the reset button and switch on again.

Motor windings burnt out.| 1. Contact your Machine Mart dealer for a replacement motor.
The compressor does not reach the set pressure and overheats.| Compressor head gasket blown or valve broken.| 1. Return the machine to your nearest Machine Mart dealer
Compressor does not start.| The reservoir has already fully pressurised.| 1. Open drain valve to expel air. Compressor should start again when pressure reduces
Air leaking from the non-return valve when the compressor is not running.| Faulty non-return valve.|

  1. Drain receiver completely of air.
  2. Remove the valve end plug
  3. Carefully clean the valve seat and the gasket
  4. Reassemble.

Air pressure from the regulator will not adjust.| The diaphragm within the regulator body is broken.| 1. Replace regulator
The compressor is very noisy and makes a metallic knocking.| Compressor damaged and needs overhaul.| 1. Return the machine to your nearest Machine Mart dealer.

EXPLODED DIAGRAM

EXPLODED DIAGRAM 1

EXPLODED DIAGRAM 2

COMPONENT PARTS LIST

1 CRANKCASE
2 CYLINDER
3 CYLINDER HEAD
4 CRANKSHAFT
5 LOWER COVER
6 VALVE HOLDER ASSEMBLY
7 CONROD
8 INTAKE FILTER ASSEMBLY
9 AIR COOLER
10 CYLINDER HEAD BOLT
11 END COVER
12 O-RING
13 BEARING 6205 XL
14 OIL SEAL D3760
15 O-RING
16 BEARING RETAINER
17 FLYWHEEL
18 DIPSTICK ASSEMBLY
19 SCREW M8X25 8.8 LEFT
20 WASHER 9.2X36X4
21 COLD START VALVE
22 PLASTIC SHROUD
23 GASKET SET
24 PISTON RING SET
25 PISTON ASSEMBLY COMPLETE
26 PISTON
27 GUDGEON PIN
28 CIRCLIP
29 HEAD GASKET
30 LOWER GASKET
31 AIR FILTER
32 HEAD BOTTOM GASKET
--- ---
33 LOWER COVER GASKET
34 NON RETURN VALVE
35 TAP BALL VALVE
36 DRAIN.VALVE 3/8
37 GAUGE 50mm 10BAR
38 SAFETY VALVE 10BAR
39 UPRIGHT CONNECTOR
40 RILSAN PIPE 4/6 BLACK
41 PRESSURE SWITCH
42 POWER CABLE
43 MOTOR
44 BELT GUARD
45 DRIVE PULLEY
46 DRIVE BELT
47 AIR PIPE
48 PUMP ASSEMBLY COMPLETE
49 FEET KIT COMPLETE

Parts & Service: 0871 410 1270 / e-mail: parts@machinemart.co.uk or customerservice@machinemart.co.uk

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals