MS2000G
Digital Clamp Meter
700019190 July 2021 Rev. 1.4
Specifications are subject to change without notification.
Special attention should be paid when using the test and measurement
instrument because improper usage may cause electric shock and damage the
equipment.
– Use proper measurement category (CAT), voltage, and amperage rated probes,
test leads, and adapters for the measurement.
– Do not use or store the device around explosive gas, vapor, or under high
temperature and humidity.
– When handling the test probes and crocodile clips, keep your fingers behind
the physical guard.
– Examine the measuring test leads (if present) before use. Any element of
which the insulation deteriorates (even partially), replace them with proper
functional test leads.
– Connect the common test lead before the live test lead and remove the live
test lead before the common test lead.
– Before measuring current, make sure the instrument fuses available and
disconnect the power supply to the circuit test
– Remove the batteries if the device is not used for an extended period of
time, or if stored in temperatures above 45 °C. If the batteries are not
removed, battery leakage can damage the device.
Contents
Specifications
Range | Resolution | Accuracy |
---|---|---|
V~ 200V/750V | 0.1V/1V | ±(1.0%+3) |
V 2V/20V/200V 1000V | 1mV/10mV/0.1V 1V | ±(0.5%+1) |
±(1.0%+2)
A~ 2000A(<600A)
2000A(600A~1000A)
2000A(>1000A) 1A| 0.1A
1A
1A
1A| ±(2.0%+5)
±(2.0%+5)
±(3.0%+5)
±(3.0%+15)
R 200Ω
20kΩ/2MΩ| 0.1Ω
10Ω/1kΩ| ±(1.0%+3)
±(1.5%+15)
Hz 2kHz
20kHz| 1Hz
10Hz| ±(2.0%+5)
±(1.5%+5)
0℃~400 ℃/32 ℉~752 ℉
°C/°F 401 ℃~750 ℃/753 ℉~1382 ℉| 1℃/1 ℉
1℃/1 ℉| ±(1.0%+3)
±(2.0%+1)
http://www.mastech-group.com/support.php?n=0 USA
MGL AMERICA, INC.
2810 Coliseum Centre Drive,
Ste. 100 Charlotte,
North Carolina 28217 USA
Tel: +1 833-533-5899
Email: cs.na@mgl-intl.com