Introduction
Omega’s OS425-LS is a fully functional infrared non-contact temperature measuring device. The unit comes in two versions: Standard, OS425-LS: -60 to 1000°C (-76 to 1832°F), and High Temperature, OS425HT-LS: -60 to 1500°C (-76 to 2732°F). Along with a magnetic mount, the OS425-LS offers laser sighting, several mathematical modes, and adjustable emissivity. Long battery life (typically 180 hours without laser or backlight), is obtained from 2 “AAA” batteries along with automatic shut-off. The 50:1 field of view measures small and distant targets. Display backlight and built-in flashlight enable night and low light viewing. There is also a thermocouple connector on the side of the unit for contact thermocouple measurements.
How it works
This handheld infrared thermometer measures the surface temperature of an
object. The unit’s optics sense emitted, reflected, and transmitted energy
which is collected and focused onto a detector. The unit’s electronics convert
the energy value into a temperature in °C or °F which is displayed on the
digital display. A clean line of sight free of dust or mist is needed between
the sensor and the object. For increased ease of use and accuracy, the laser
pointer makes aiming even more precise.
Measurement
When taking the measurement, point the thermometer toward the object to be
measured and hold the trigger. The temperature will be displayed and the word
“SCAN” will flash on the right-hand side of the LCD screen to indicate that
the temperature is continually being updated on the display. When the trigger
is released, the last reading seen will be held on the display and the word
“HOLD” will be visible on the left-hand side of the LCD screen. The object
under test should be larger than the spot size calculated by the field of view
diagram below.
Field of View
Field of view, or distance to spot ratio, is the size of an area that can be
measured from a specified distance. As the distance from the object increases,
the spot size of the measuring area becomes larger. Make sure the target is
larger than the unit’s spot size. When accuracy is critical, make sure the
target is at least twice as large as the spot size. Please see field of view
diagram for the OS836-Series below.
Units in mm
Emissivity
Most organic materials and painted or oxidized surfaces have an emissivity of
0.95 (pre-set in the unit). Inaccurate readings will result from measuring
shiny or polished metal surfaces. To compensate, cover the measured surface
with masking tape of flat black paint. Measure the tape or painted surface
when the tape or painted surface reaches the material temperature.
Emissivity Table
Material | Emissivity | Material | Emissivity |
---|---|---|---|
Aluminum | 0.30 | Iron | 0.70 |
Asbestos | 0.95 | Lead | 0.50 |
Asphalt | 0.95 | Limestone | 0.98 |
Basalt | 0.70 | Oil | 0.94 |
Brass | 0.50 | Paint | 0.93 |
Brick | 0.90 | Paper | 0.95 |
Carbon | 0.85 | Plastic | 0.95 |
Ceramic | 0.95 | Rubber | 0.95 |
Concrete | 0.95 | Sand | 0.90 |
Copper | 0.95 | Skin | 0.98 |
Dirt | 0.94 | Snow | 0.90 |
Frozen Food | 0.90 | Steel | 0.80 |
Hot food | 0.93 | Textiles | 0.94 |
Glass (plate) | 0.85 | Water | 0.93 |
Ice | 0.98 | Wood | 0.94 |
Caution
Infrared thermometer should be protected for the following:
- EMF (electro-magnetic fields) from arc welders and induction heaters.
- Thermal shock (caused by large or abrupt ambient temperature changes allow 30 minutes for unit to stabilize before use).
- Do not leave the unit on or near objects of high temperature.
Warning: Do not point laser directly at eye or indirectly off reflective surfaces!
Specifications
Temperature Range| OS425-LS : -60 to 1000°C (-76 to 1832°F),
OS425HT-LS : -60 to 1500°C (-76 to 2372°F)
---|---
Thermocouple Range| -64 to 1400°C (-83 to 2552°F)
Accuracy| ±2% rdg or 2°C (3.5°F), whichever is greater
Thermocouple Accuracy| ±1% of rdg or 1°C, whichever is greater
Field of View| 50:1
Response Time| 1 sec
Spectral Response| 8 – 14 µm
Emissivity| Adjustable emissivity 0.10 – 1.00
Operating Temperature Range| 0 – 50°C (32 – 122°F)
Relative Humidity| 10 -90% RH, Storage <80% RH
Weight| 13.62 oz (386.1 grams) including batteries
Dimensions| 8.0 x 7.7 x 1.8 in (203.3 x 197.0 x 47.0 mm)
Power| AAA Batteries (2)
Automatic Power Shutoff| Automatic shutoff after 60 seconds
Estimated Battery Life| Typ. 180 hours, 140 hours with continuous use
(without laser and backlight)
Operating Instructions
Battery Installation
Open the battery compartment (1) on the front of the device by pulling in the
direction of the arrow (2).
Insert two “AA” batteries (3) into the battery compartment, and then close
battery compartment.
Product Layout
- Emissivity Key
- “Down” (C/F) Key
- LCD
- “UP” (Lock) Key
- Mode Key
- Measurement Key
- Battery Cover
- Infrared Lens
- Circle Dot Laser
- Flashlight LED
- Thermocouple Socket
Button Layout
LCD Display
- Current Temperature Values
- HOLD/SCAN Indicator
- Icon for MAX, MIN, DIF, AVG, PROBE, ALARM, and Emissivity
- Low Battery Indicator
- Backlit Display Indicator
Operating Steps
- Hold the thermometer by the handle grip and point it towards the surface to be measured.
- Pull and hold the trigger to turn the thermometer on, the “SCAN” icon will appear and blink when measurement starts.
- The surface temperature being measured will be displayed on the LCD screen.
- Release the trigger, the “HOLD” icon will appear and the reading will stay on the display screen.
- The thermometer will automatically shut off 60 seconds after the trigger is released.
Note: If the thermometer is to be used in ambient temperature after a
large temperature change wait 30 minutes for the thermometer to adjust to
ambient temperature.
The laser is designed for aiming only, it can be shut off while operating in
shorter distances to save battery (Section 3.5.3).
Button function
Setting Mode
- Press the “MODE” key to cycle through the different modes.
Changing temperature units
- While unit is any mode (without pressing the Measurement Key, press the “DOWN (C/F)” button to change temperature units.
Adjusting Laser
- While holding the trigger and activating “SCAN” mode, press the “DOWN (C/F)” button to toggle the circle-dot laser pointer on and off. The outer perimeter of the dots indicates the actual target size.
Activating “SCAN LOCK” Mode
- To lock unit on “SCAN” to see continual changes in temperature without the unit shutting off, press and release the “Measurement” key (trigger). The display will show “HOLD” in the left-hand corner. Press the “LOCK” key once to lock in “SCAN” mode. To get out of the locked mode, press the “LOCK” key for 2 seconds.
- To get out of LOCK mode, press the “LOCK” key for 2 seconds. The word “HOLD” will appear again.
Adjusting Emissivity
- After turning on the unit, press the “Emissivity” key a few times to access the “Є” emissivity mode. Use the “UP/DOWN” buttons to adjust emissivity to desired value.
- To exit “Emissivity Adjust” mode, press the “Mode” key one time.
Adjusting High/Low Alarm
- Press the “MODE” key until “LAL (low alarm) or “HAL” (high alarm) is shown on the lower part of the display along with the current value. Use the “Up/Down” arrows to adjust to the desired value.
- Press and hold “MODE” key to exit Alarm setting mode.
Contact Temperature Measurement
- With unit turned on, press the “MODE” key until the lower display shows “PRB” (probe).
- Insert a thermocouple into the thermocouple socket (11) to obtain a temperature reading on the bottom portion of the display. Note, if there is no thermocouple connected, lower part of display will show “noP” to indicate “no probe attached.”
Turning on “Backlight”
- To turn on Backlight, while holding “Measurement key,” press the “Lock” key to turn Backlight on.
While holding “Measurement key,” press “Lock” key again to turn backlight off.
Displaying Mathematical Values
- To display mathematical values such as Min, Max, etc, press and release the “Measurement” key.
- Press the “MODE” key to display (in this order): MAX (Maximum value seen during session); MIN (minimum value seen during session; DIF (difference (in °C or °F) seen during session; and AVG (average reading seen during session). All values will be shown in the lower part of the digital display.
Locating a Hotspot
To find a hot spot aim the thermometer outside the area of interest, then scan
across with up and down motions until you locate the hot spot. (Please turn on
the laser for accurate measuring)
Maintenance
- Lens cleaning : blow off loose particles using clean compressed air. Gently brush remaining debris away with a moist cotton cloth.
- Case cleaning: clean the case with a damp sponge/cloth and mild soap.
Note: Do not use solvent to clean lens and do not submerge the unit into water or any other liquid.
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various products.
However, OMEGA neither assumes responsibility for any omissions or errors nor
assumes liability for any damages that result from the use of its products in
accordance with information provided by OMEGA, either verbal or written. OMEGA
warrants only that the parts manufactured by the company will be as specified
and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY
KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED
WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF
LIABILITY: The remedies of purchaser set forth herein are exclusive, and the
total liability of OMEGA with respect to this order, whether based on
contract, warranty, negligence, indemnification, strict liability or
otherwise, shall not exceed the purchase price of the component upon which
liability is based. In no event shall OMEGA be liable for consequential,
incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer
Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST
OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE
DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number
should then be marked on the outside of the return package and on any
correspondence.
The purchaser is responsible for shipping charges, freight, insurance and
proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA:
- Purchase Order number under which the product was PURCHASED,
- Model and serial number of the product under warranty, and
- Repair instructions and/or specific problems relative to the product.
FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:
- Purchase Order number to cover the COST of the repair,
- Model and serial number of the product, and
- Repair instructions and/or specific problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an
improvement is possible. This affords our customers the latest in technology
and engineering.
OMEGA is a trademark of OMEGA ENGINEERING, INC.
© Copyright 2019 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.
Where Do I Find Everything I Need for Process Measurement and Control?
OMEGA…Of Course!
Shop online at omega.com
TEMPERATURE
✓ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies
✓ Wire: Thermocouple, RTD & Thermistor
✓ Calibrators & Ice Point References
✓ Recorders, Controllers & Process Monitors
✓ Infrared Pyrometers
PRESSURE, STRAIN AND FORCE
✓ Transducers & Strain Gages
✓ Load Cells & Pressure Gages
✓ Displacement Transducers
✓ Instrumentation & Accessories
FLOW/LEVEL
✓ Rotameters, Gas Mass Flowmeters & Flow Computers
✓ Air Velocity Indicators
✓ Turbine/Paddlewheel Systems
✓ Totalizers & Batch Controllers
pH/CONDUCTIVITY
✓ pH Electrodes, Testers & Accessories
✓ Benchtop/Laboratory Meters
✓ Controllers, Calibrators, Simulators & Pumps
✓ Industrial pH & Conductivity Equipment
DATA ACQUISITION
✓ Communications-Based Acquisition Systems
✓ Data Logging Systems
✓ Wireless Sensors, Transmitters, & Receivers
✓ Signal Conditioners
✓ Data Acquisition Software
HEATERS
✓ Heating Cable
✓ Cartridge & Strip Heaters
✓ Immersion & Band Heaters
✓ Flexible Heaters
✓ Laboratory Heaters
ENVIRONMENTAL MONITORING AND CONTROL
✓ Metering & Control Instrumentation
✓ Refractometers
✓ Pumps & Tubing
✓ Air, Soil & Water Monitors
✓ Industrial Water & Wastewater Treatment
✓ pH, Conductivity & Dissolved Oxygen Instruments
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>