ATTEN ST-862D Hot Air Station User Manual

June 6, 2024
ATTEN

ATTEN ST-862D Hot Air Station

ATTEN ST-862D Hot Air Station

ATTEN ST-862D Hot Air Station fig 1

Schematic Diagram of the Whole Equipment

ATTEN ST-862D Hot Air Station fig 20

Connection Diagram for the Whole Equipment

ATTEN ST-862D Hot Air Station fig 21

Technical Data

Model: ST-862D
Voltage AC230V±10% 50Hz  (110V±10% 60Hz Optional)
Power 1000W
Fuse type T6.3A                   T10A
Temperature range:
Temperature accuracy ±35℃
10
Temperature unit °C/°F (default °C)
Air flow 120L/min(Max) 30L/min(Min)
Standby heater cooling function Support
Abnormal detection of heating element Heating element remove detection;

heating element open circuit detection; heating element overheating detection
Abnormal detection of temperature sensor| Temperature sensor open circuit detection
Beep alarm function| Available
Quick function| 3 sets shortcut temperatures
Temperature compensation| ±50°C/±90°F
Heating status display| 5 dynamic simulate bars
Temperature adjustment| 10 digits (Coarse)/1 digit (Fine-tuning)
Air flow adjustment| 2 digits (Coarse)/1 digit (Fine-tuning)
Shortcut temperature/ air flow| 3 sets shortcut temperatures/air flow for quick selection
Working conditions| Temperature 0-40°C, relative humidity <80%
Storage conditions| Temperature -20-80°C, relative humidity <80%
Dimension| 208(L)x175(W)x150(H)mm
Weight| About 3340g

LCD Description

  1.  REAL (Real Temperature): Real Temperature status
  2. SET (Set Temperature): Start up and set temperature status
  3. Actual temperature value
  4. Display bar for heating power status
  5. Symbol for lock
  6. Display settings value
  7. Air flow percentage
  8. Temperature unit

ATTEN ST-862D Hot Air Station fig 4

Boot-up Screen

After the station has been switched on, the display will turn on and show the system version number for one second before switching to the normal display.

ATTEN ST-862D Hot Air Station fig 5

Settings

Normal display

(FIG. 1-1) shows real temperature is 300°C, the temperature setting value is locked, the air volume is 50% and the heating power value is 3 bars.

ATTEN ST-862D Hot Air Station fig 6 Display Of Hot Air Gun Status
(FIG. 1-2)shows when the air gun is off (non-power)) The setting value can be adjusted when the hot air gun is off. When the hot air gun is on, it will work according to the setting value.(FIG. 1-3) When the handle of the air gun is placed on the holder, the hot air gun will automatically stop heating and delay air supply, (the air supply will stop after the heating wire cools). Pick up the handle again and press the switch key on the handle, it will resume to work. ATTEN ST-862D Hot Air Station fig 7

Temperature/Air Flow Setting

  1.  Adjust the air volume: Press air “▲” or “▼” key (see FIG 1-4). Long press for quickly adjusting. Stop pressing the key for 3 seconds, it will save the setting automatically.
  2. Adjust temperature value (when temperature value is locked, it can not be adjusted): Press temperature “▲” or “▼” key, switch to SET status (see figure 1-5). Long press for quickly adjusting, stop pressing the key for 3 seconds, it will automatically save temperature setting, and state switch to REAL. ATTEN ST-862D Hot Air Station fig 8

Saving and Retrieving Shortcut Temperature(User define)

  1. Retrieving shortcut temperature: It can rapidly retrieving preset temperature and blowing restored in Button “1”/“2”/“3” by pressing Button “1”/“2”/“3”.(FIG. 1-6) when working 
  2. Saving shortcut temperature: It can save the user-define temperature and blowing in Button “1”/ “2”/ “3” by pressing Button “1”/ “2”/ “3” more than 3 seconds.

ATTEN ST-862D Hot Air Station fig 9

Enter into menu mode by pressing both Button “1” and “3” more than 3 seconds under working status.

  1. Button Definition under Menu Setting Mode ATTEN ST-862D Hot Air Station fig 10 Button “1”: Menu page up
    Button “2”: Menu exit
    Button “3”: Menu page down
    Parameter plus
    Parameter minus

  2. Temperature Locking Function
    Under Menu Loc, it can turn on or turn off temperature locking function by pressing
    “▲”or“▼”key(FIG. 1-8, ON means turn on temperature lock function, OFF means turn off temperature locking function); it can turn up or down menu by pressing Button “1” or “3”, then press Button “2” to exit and save your setting.

  3. Defining Work Function
    Under menu HTO mode, it can adjust time of defining work by pressing “▲”or“▼” key (FIG. 1-9, the time of defining work is 20 seconds, “0” means turn off defining work function, the minimum setting time for defining work is 10 seconds, maximum setting time is 900 seconds. ); it can turn up or down menu by pressing Button “1” or “3”, then press Button “2” to exit and save your setting.ATTEN ST-862D Hot Air Station fig 11

  4. Switching Temperature UnitATTEN ST-862D Hot Air Station fig 12

  5. Temperature Calibration
    Under menu CAL mode, press “▲”or“▼”key to enable temperature calibration function, whose calibration range is -50℃~ 50℃(-90℉~90℉). Calibration value will be negative as actual-measured temperature is lower than setting temperature; Calibration value will be positive as actual-measured temperature is higher than setting temperature.
    ATTEN ST-862D Hot Air Station fig 14 Note: User need calibrate temperature by adjusting its value if the displayed temperature is much different with actual-measured temperature after changing a new heater or tips, its calibration method be refered as below:
    1. Set this handle required calibration as a suitable temperature like 350℃/ 662℉;
    2. After this setting temperature is stable, use temperature tester to measure the actual temperature of its tip, for example, its actual-measured temperature is 365℃/ 689℉;
    3. We can get conclusion that the actual-measured temperature compared to the setting temperature is 15℃/ 27℉ higher;
    4. Then press “▲” key to calibrate temperature.

  6. Button Beeping Function
    Under menu BL mode, user can turn on/ off the beeping function by pressing “▲”or “▼”key.Refer Pic.1-14, OFF disable beeping function;Refer Pic.1-15, ON enables beeping function.
    ATTEN ST-862D Hot Air Station fig 14

  7. Restore Factory Setting
    In FAC menu ,press “▲”and“▼”keys to adjust ON/OFF. Press the [2] key when the menu is ON, then return to the normal operation interface to restore factory settingATTEN ST-862D Hot Air Station fig 15

Default value :

  • Loc ( temperature locked function):
  • OFF CAL(calibration value): cleared
  • BL(Beeping function):ON
  • F-C(temperature unit):℃
  • HTO(Timing operation) : OFF
  • Memory temperature 1:200°C
  • Memory temperature 2:300°C
  • Memory temperature3:400°C

Care And Maintenance

ATTEN ST-862D Hot Air Station fig 16 WARRANTY

ATTEN ST-862D Hot Air Station fig 17 ATTEN ST-
862D Hot Air Station fig 18 ATTEN ST-862D Hot Air Station fig
19

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals